Systematic Component-Level Characterization of Electricity Transmission Infrastructure for Space Weather Risk Assessment

Dennies K. Bor 1,2†, Edward J. Oughton 1∗†, Evan A. Peters 1†, Noah Rivera 1, C. Trevor Gaunt 3, Robert S. Weigel 1,2, Michael Wiltberger 4 1 Department of Geography, Geoinformation Sciences, George Mason University, Fairfax, VA, USA. 2 Space Weather Lab, George Mason University, Fairfax, VA, USA. 3 · 2024

Read Systematic Component-Level Characterization of Electricity Transmission Infrastructure for Space Weather Risk Assessment by Dennies K. Bor 1,2†, Edward J. Oughton 1∗†, Evan A. Peters 1†, Noah Rivera 1, C. Trevor Gaunt 3, Robert S. Weigel 1,2, Michael Wiltberger 4 1 Department of Geography, Geoinformation Sciences, George Mason University, Fairfax, VA, USA. 2 Space Weather Lab, George Mason University, Fairfax, VA, USA. 3 (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-17685.txt.

Introduction

Dennies Bor and co-authors set out a method in 2024 to map power grid parts in fine detail for space weather risk work. Storms from the Sun can drive stray flows in grid wires, but risk teams lack good maps of what sits in each yard. The team built its maps from open sources.

Using map points and photos from planes, satellites, and street views, they turned more than a thousand high-power yards into tens of thousands of parts. They found near eight thousand of the big boxes that step power up or down. A test grid for one river valley shows how the maps feed risk models. Grid planners gain a way to build such data on their own.

Catalog record

CREATORDennies K. Bor 1,2†, Edward J. Oughton 1∗†, Evan A. Peters 1†, Noah Rivera 1, C. Trevor Gaunt 3, Robert S. Weigel 1,2, Michael Wiltberger 4 1 Department of Geography, Geoinformation Sciences, George Mason University, Fairfax, VA, USA. 2 Space Weather Lab, George Mason University, Fairfax, VA, USA. 3
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE69 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-17685

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Systematic Component-Level Characterization of Electricity Transmission Infrastructure for Space Weather Risk Assessment Dennies K. Bor 1,2†, Edward J. Oughton 1∗†, Evan A. Peters 1†, Noah Rivera 1, C. Trevor Gaunt 3, Robert S. Weigel 1,2, Michael Wiltberger 4 1 Department of Geography, Geoinformation Sciences, George Mason University, Fairfax, VA, USA. 2 Space Weather Lab, George Mason University, Fairfax, VA, USA. 3 Dept. of Electrical Engineering, University of Cape Town, Cape Town, South Africa. 4 U.S. National Science Foundation National Center for Atmospheric Research, Boulder, CO, USA. ∗ Corresponding author (email: [email protected]). † Authors contributed equally. Abstract Space weather risk assessment is constrained by the lack of available asset information needed to model geomagnetically induced currents (GICs) in electricity transmission infrastructure. We propose a systematic method that enables risk analysts to collect their own open-source substation data. Using a web browser platform for annotation, we convert OpenStreetMap (OSM) substation locations into high-resolution, component-level mappings of electricity transmission assets. We convert an initial 1,313 high-voltage ( ≥ 230 ​ kV \geq 230\ \mathrm{kV} ) substations to 52,273 components using low-altitude, satellite, and Street View imagery accessed through Google Earth, identifying 7,949 transformers. Compared to the OSM baseline, this approach provides detailed insights on voltage levels and substation configurations. We then construct a geospatial GIC network for the Tennessee Valley Authority (TVA) region, comparing May 2024 results with the University of Illinois Urbana-Champaign 150-bus (UIUC150) synthetic network and with measured ground GICs at 13 monitoring devices. The transformer types at unannotated substations and the grounding resistances are unknown, so we sample both across a Monte Carlo ensemble. This gives a median TVA 95th-percentile peak ground GIC of 29.1 A, with a 90% confidence interval of 23.9–36.1 A. The UIUC150 network yields a 95th-percentile peak ground GIC of 35.8 A under the same forcing, falling within this interval, and the modeled time series broadly capture the temporal morphology of the geomagnetic storm at the monitoring sites. This method shows promise for spatially explicit, screening-level GIC assessment without requiring access to operator data. † † journal: Space Weather keypoints Power grid component data are essential for evaluating geomagnetically induced currents (GICs) 52,273 components are collected from 1,313 substations, including counts of transformer types The dataset supports regional GIC screening and first-order GIC estimation during geomagnetic storms, using open-source data Plain language summary Datasets on power grid assets are essential for space weather assessment. Unfortunately, this information is not readily available and rarely shared by network owners. Thankfully, we can collect these data from different types of imagery, such as from satellite and Google Street View imagery. We develop a method to quickly survey substations and collect component information on the assets present, including counts of transformer types, which can then be used to refine vulnerability assessments of geomagnetically induced currents (GICs). We show that the dataset can be used to construct a regional GIC network that broadly captures the temporal morphology of ground currents observed during an actual geomagnetic storm, without requiring access to protected operational parameters from network operators. 1 Introduction There is grave concern about the threat of severe space weather affecting the critical infrastructure upon which we all rely, particularly for the ongoing operation of the power grid Andreyev et al. (2023) ; Cordell et al. (2024) ; Dimmock et al. (2024) ; Smith et al. (2024) ; Vandegriff et al. (2024) . Historical evidence indicates the possible impacts of geomagnetically induced currents (GICs) on extra-high-voltage (EHV) electricity transmission infrastructure. These impacts include power system interruptions and collapse (blackouts), damage to transformers and neutral earthing resistors, and the misoperation of protective relays and reactive power compensation equipment such as capacitor banks and static var compensators. Such consequences motivate risk assessment to support mitigation decisions Akbari et al. (2023) ; Akbari and Rezaei-Zare (2023) ; Albert et al. (2022) ; Crack et al. (2024) ; Espinosa et al. (2023) ; Ingham et al. (2023) ; Lanabere et al. (2023) ; Liu et al. (2024) ; Marshalko et al. (2023) ; Nakamura et al. (2018) ; Ngwira et al. (2023) ; Pratscher et al. (2024) ; Subritzky et al. (2024) . Indeed, EHV transformers are expensive, hard to procure, and difficult to move. These assets are also challenging to repair or replace, highlighting possible supply chain difficulties. Currently there is already a global shortage in EHV transformers, with business-as-usual waiting times reported to be 2–3 years once ordered Moseman (2024) . A global spike in demand for these assets, arising from a major space weather event, could cause considerable long-term disruption to society and the economy. A wide variety of assessments have shown the potential economic impacts of an extreme event up to tens of billions of dollars of daily lost gross domestic product (GDP) Oughton (2018) ; Oughton et al. (2017) . The U.S. Government Accountability Office estimates a single GIC-induced blackout could cost up to $1 billion to the U.S. economy, underscoring the importance of protecting critical infrastructure from space weather impacts U.S. Government Accountability Office (GAO) (2018) . Vulnerability to geomagnetic disturbances (GMDs) is one of many hazards capable of degrading transmission assets through mechanical stresses and/or component failure, with the potential to cause large electricity outages Kondrateva et al. (2020) ; Oughton et al. (2019) ; Verschuur et al. (2024) . Consequently, there is an urgent need to map, model and pinpoint electricity transmission infrastructure vulnerabilities from natural hazards such as space weather, as identified by successive policy directives, such as via the U.S. National Space Weather Strategy SWORM (2023) ; SWORM (2019) ; SWORM (2015) . One approach over the past decade has been towards developing synthetic power networks which have broadly representative statistical characteristics to support modeling studies Birchfield et al. (2017a) ; Birchfield et al. (2017b) ; Li et al. (2020) ; Xu et al. (2018) . This research has been a step in the right direction, improving the types of data available to assess potential GIC impacts on electricity transmission infrastructure. However, this approach does not enable modelers to understand specific hotspots of risk to their assets and power systems and still leads to considerable uncertainty in identifying where to direct resources and research efforts nationally. Such strategic insight is absolutely required. Thus, our conjecture is that more data can still be collected from emerging geospatial data sources to improve our understanding of electrical transmission infrastructure, such as transformer counts, even if this only provides a partial understanding of the operational parameters in use, such as grounding resistances and transformer winding types. Indeed, authoritative overviews of the methods for calculating GIC emphasize the importance of including appropriate power system characteristics for a modeled circuit, along with magnetic source fields and the present ground conductivity structure Boteler and Pirjola (2017) . Once general areas of elevated exposure are identified, more specific and detailed modeling and engagement with the relevant utility can be undertaken using their detailed power system data and models. Operational plans can then be implemented to mitigate vulnerabilities, protecting society and the economy Mac Manus et al. (2023) . The developments in this paper offer new opportunities for electrical transmission network mapping and validation. By incorporating this approach, researchers can generate more refined datasets describing

Read the complete text