Cavity-enhanced continuous-wave microscopy using unstabilized cavities
Oliver Lueghamer, Stefan Nimmrichter, Clara Conrad-Billroth, Thomas Juffmann, Maximilian Prüfer · 2024
Read Cavity-enhanced continuous-wave microscopy using unstabilized cavities by Oliver Lueghamer, Stefan Nimmrichter, Clara Conrad-Billroth, Thomas Juffmann, Maximilian Prüfer (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-16909.txt.
Introduction
Oliver Lueghamer and four co-authors boost microscope signals in a paper from twenty twenty-four. Microscopes reveal spatial detail in systems from cells to cold atoms. The challenge is to gain more information per probe particle, since probing can damage the sample. A cavity, a set of mirrors that trap light, can amplify the signal.
Their method uses a self-imaging cavity in a continuous-wave setup. It raised contrast for test samples and for biological samples alike. For thick samples, the cavity yields a new kind of dark-field imaging. Scattered and unscattered light are split by optical path length there. Theory shows the gains hold even when the cavity is not stabilized. Readers get better signal at fixed damage, with simpler hardware.
Catalog record
| CREATOR | Oliver Lueghamer, Stefan Nimmrichter, Clara Conrad-Billroth, Thomas Juffmann, Maximilian Prüfer |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 55 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-16909
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Cavity-enhanced continuous-wave microscopy using unstabilized cavities Oliver Lueghamer, Stefan Nimmrichter, Clara Conrad-Billroth, Thomas Juffmann, Maximilian Prüfer Abstract Microscopy gives access to spatially resolved dynamics in different systems, from biological cells to cold atoms. A big challenge is maximizing the information per used probe particle to limit the damage to the probed system. We present a cavity-enhanced continuous-wave microscopy approach that provides enhanced signal-to-noise ratios at fixed damage. Employing a self-imaging 4f cavity, we show contrast enhancement for controlled test samples as well as biological samples. For thick samples, the imaging cavity leads to a new form of dark-field microscopy, where the separation of scattered and unscattered light is based on optical path length. We theoretically show that enhanced signal, signal-to-noise, and signal-to-noise per damage are also retrieved when the cavity cannot be stabilized. Our results provide an approach to cavity-enhanced microscopy with unstabilized cavities and might be used to enhance the performance of dispersive imaging of ultracold atoms. Advances in microscopy have led to new discoveries across scientific disciplines [ 1 ] , from cellular biology [ 2 ] to quantum physics [ 3 ] and beyond. Microscopy setups measure certain parameters of interest in a spatially resolved way. Not only the spatial resolution limits the measurement precision but often the limiting factor is the finite number of probe particles detected in a given image. In many applications, the number of probe particles cannot be increased arbitrarily, either due to sample, source, or detector restrictions. Maximizing the information obtained from each detected probe particle is crucial in such applications. For coherent imaging techniques, it has recently been shown that multi-passing each probe particle through the sample can increase the information per detected probe particle. This has been experimentally demonstrated in optical imaging and diffraction studies [ 4 ] , where self-imaging cavities [ 5 ] were used to multi-pass a pulsed probe through a sample. Follow-up experiments showed the build-up of orbital angular momentum in a multi-passing experiment [ 6 ] . Notably, multi-passing probe particles m times through a sample can enable a measurement precision per probe-sample interaction similar to a quantum-enhanced measurement with m suitably entangled probe particles [ 7 , 8 , 9 , 10 ] . In physics applications, like spectroscopy or the imaging of ultracold atoms, a narrow spectral linewidth is often required. Thus, cavity-enhanced microscopy has to be done with continuous-wave (CW) excitation, which actually has theoretically been shown to outperform the pulsed multi-pass scheme [ 11 ] . However, despite the widespread use of single-mode cavity-enhanced measurements in various scientific and technological fields, applications in imaging remain rare, due to challenges in operating a cavity that is fully degenerate in all transverse modes [ 12 ] . The first progress was recently demonstrated in a 4-pass geometry that showed contrast enhancement in flow-cytommetry [ 13 ] . So far, genuine continuous-wave imaging cavities have been employed in the realization of multi-mode lasers [ 14 ] , multi-mode coherent absorbers [ 15 ] , and cavity-enhanced non-linear optics applications [ 16 ] . In this paper, we demonstrate cavity-enhanced continuous-wave microscopy using a self-imaging 4f cavity. We demonstrate the concept experimentally by applying it to the imaging of an artificially fabricated sample, consisting of holes in a 10\,\text{nm} thin silicon nitride ( \text{Si}_{3}\text{N}_{4} ) membrane. Imaging human cheek cells, we further demonstrate that cavity-based imaging leads to a novel form of dark-field microscopy, where the separation of scattered and unscattered light is based on optical path length and not on scattering angle. Our experiments are backed by theory which shows that an enhanced contrast can even be observed when scanning the cavity across a free spectral range of the cavity. These results open a path to cavity-enhanced measurements in applications where cavity stabilization is impossible. Our continuous-wave approach will facilitate the usage of cavities for microscopy with the need for small spectral width, for example, the imaging of ultracold atoms. Figure 1: Cavity setup and characterization. a) Ray tracing picture showing the self-imaging properties of the 4f cavity. The sample is illuminated with a collimated beam (red); the diffracted light (green) is imaged onto the sample after one full roundtrip. b) Cavity length scan monitored by the output voltage (normalized) of a photodiode placed at the output of the cavity. The separation between the two resonance peaks yields a free spectral range (FSR) of 488\,\text{MHz} . c) We test the degeneracy of transversal modes by projecting the image of a US Air Force (USAF) Target onto the cavity image plane. The recorded light intensity in a conjugate plane after the cavity, and a cross-section thereof, demonstrate its image transmission capabilities. Figure 2: Cavity-enhanced microscopy of holes in a \text{Si}_{3}\text{N}_{4} membrane . a) Scanning electron microscopy image of holes cut into a \text{Si}_{3}\text{N}_{4} membrane. The red and blue circles indicate holes with a diameter of 10\,\mu\text{m} , and the yellow circle marks a hole with a diameter of 6\,\mu\text{m} . The inset shows a close-up of the hole we use as our main target. b) Defocused single-pass image of the membrane; the inset shows the region of the image with the target in focus; the target hole is not visible (see main text). c) Cavity-enhanced image of the membrane; the two circles indicate the targeted hole (solid) and its reflection (dashed line). The inset shows a close-up of the target; compared to the single pass case we find a contrast enhancement; the two circles show the regions for averaging signal (red) and background (blue without red) intensities, used to estimate contrast and SNR. d) Signal-to-noise ratio in the cavity-enhanced case plotted against the number of effective round trips. The color-coded data points match those in the inset, where the transmitted intensity is shown as a function of the cavity length. Degenerate cavity setup.— For cavity-enhanced microscopy, it is crucial that spatial information is accurately transmitted through the cavity system. To achieve this, the transverse cavity modes have to be degenerate, i.e. they resonate simultaneously at the same cavity length. Degeneracy can be achieved by using lenses within the cavity to ensure that any arbitrary ray retraces its path after a full round trip [ 5 ] . We employ an effective 4f configuration using two highly reflective cavity mirrors and a pair of f=75\,\text{mm} biconvex lenses; a schematic of the setup is shown in fig. 1 (see Supplementary Material for details). The sample is positioned off-axis to prevent overlapping with the mirrored image; as a result, the image is projected onto the sample only after completing one full round trip. Control over the cavity length is achieved via a piezo ring mounted on the first mirror. For monitoring the cavity output, a photodiode is placed after a beamsplitter, and the remaining light is imaged on a charge-coupled device (CCD) camera. Various standard imaging modalities, such as bright-field, darkfield, or Zernicke phase imaging, can be implemented outside the cavity (see Supplementary Material for imaging details). In fig. 1 , we present a cavity scan where we show the output intensity measured using a photodiode as a function of the cavity length. The spacing between the two peaks represents the free spectral range (FSR), achieved by moving