Enhancement in temperature sensing of a reservoir by Kerr-nonlinear resonator

Naeem Akhtar, Jia-Xin Peng, Xiaosen Yang, Yuanping Chen · 2024

Read Enhancement in temperature sensing of a reservoir by Kerr-nonlinear resonator by Naeem Akhtar, Jia-Xin Peng, Xiaosen Yang, Yuanping Chen (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-16650.txt.

Introduction

Naeem Akhtar and three co-authors wrote this 2024 arXiv paper on a quantum thermometer built from a nonlinear resonator. Measuring the heat of a tiny quantum bath with precision is a live challenge. Their probe is a resonator whose response bends with intensity, driven by an external tone, and left to settle into balance with the bath.

Using a standard measure of how much information the probe state carries about temperature, they show two knobs sharpen the reading: stronger nonlinearity and a stronger drive. Checking the probe's purity helps explain the gain. Among simple light measurements, one style, homodyne, beat its rival but still fell short of the best possible readout. The work guides designers of quantum sensors toward the settings where heat reads clearest.

Catalog record

CREATORNaeem Akhtar, Jia-Xin Peng, Xiaosen Yang, Yuanping Chen
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE30 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-16650

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Enhancement in temperature sensing of a reservoir by Kerr-nonlinear resonator Naeem Akhtar, Jia-Xin Peng, Xiaosen Yang, Yuanping Chen Abstract The challenge of developing high-precision temperature sensors is an important issue that has recently received a lot of attention. In this work, we introduce an estimation technique to precisely measure the temperature of a quantum reservoir using a Kerr-nonlinear resonator with drive. Thermalization in our suggested protocol is assessed using Uhlmann-Jozsa fidelity, and then we utilize quantum Fisher information to evaluate the metrological potential of our thermometry scheme. We observe that increasing the Kerr nonlinearity coefficient and driving amplitude significantly enhances precision in the temperature estimation. Furthermore, we also explore the underlying physical mechanisms by analyzing probe purity in the steady state and evaluating the performance of homodyne versus heterodyne detection methods. Our results demonstrate that neither of these Gaussian measurements is optimal; instead, optimal homodyne detection always surpasses heterodyne detection. Introduction.– Quantum metrology [ 1 , 2 , 3 , 4 , 5 ] has expanded the boundaries of thermodynamics [ 6 , 7 , 8 , 9 ] , allowing small objects to be cooled to extremely low temperatures [ 10 , 11 ] . Quantum thermodynamics combines the thermodynamic principles and laws of quantum physics to explain the effects of thermalization, refrigeration, transport phenomena, out-of-equilibrium dynamics, and assessing the thermal properties of small-scale objects and thermal reservoirs [ 6 , 7 , 8 , 9 ] . Measuring thermodynamic quantities at the quantum level necessitates tremendous precision [ 1 ] as well as superior cooling [ 12 ] . Temperature, defined through the zeroth law of thermodynamics, is one of the important thermodynamical parameters, and a precise measurement of temperature is crucial for both classical and quantum thermodynamics. Significant interest has been shown in the highly accurate temperature measurement of quantum reservoirs [ 13 , 14 , 15 ] . The precise measurement of temperature in a quantum system is challenging due to the limitations imposed by quantum principles [ 3 , 4 , 5 ] . Quantum thermometry [ 16 , 17 , 18 , 19 , 20 , 21 , 22 ] , a promising field in quantum metrology, employs quantum thermometers to measure low temperatures with accuracy well beyond the standard bound set by classical statistics [ 4 , 5 ] . Most thermometry schemes are based on a two-level system [ 23 , 24 ] or a harmonic oscillator [ 25 , 26 ] , working as the quantum sensor, is connected to the quantum reservoir of interest [ 27 ] . The interaction between the sensor and reservoir encodes information about the temperature associated with the reservoir into the state of the sensor, which is then obtained by measuring a specific observable associated with the sensor. A number of techniques have been proposed to achieve a precise measurement of temperature associated with quantum systems, which included quantum control [ 28 , 29 ] , strong coupling [ 30 , 31 ] , non-Markovian effects [ 27 , 32 , 33 ] , and adding auxiliary devices [ 34 , 35 , 36 ] , to name a few. In general, there are two distinct types of quantum thermometers that rely on different techniques. In the first instance, equilibrium thermometry [ 37 , 38 , 39 , 40 , 41 ] , which is a technique for measuring temperature that is relatively more common, involves the contact of a probe with a sample (a reservoir of temperature T ). The probe is then measured once it has reached equilibrium with the system and is thus defined by a thermal state at the same temperature as the system. Nonequilibrium thermometry is another thermometry scheme [ 42 , 34 , 43 , 44 , 24 , 45 , 46 , 47 , 28 , 48 ] , in which temperature is extracted as a parameter from the state of the probe before its thermalization. In equilibrium thermometry, which is the focus of this work, energy measurement is found to be the optimal choice for saturating the quantum Cramér-Rao (CR) constraint [ 38 ] independent of temperature. In contrast, in nonequilibrium thermometry, the optimal measurement, which minimizes the uncertainty of the estimation by saturating the CR inequality [ 49 ] , is typically dependent on the unknown temperature of the system, making its realization difficult in practice. In this work, we provide an estimation technique for precisely measuring the temperature of a thermal reservoir. Our estimation scheme is employed by using a nonlinear Kerr-resonator with drive to precisely estimate the temperature of a bosonic reservoir. Kerr-resonators have also been utilized in the past to improve the precision of quantum magnetometers and the accuracy of superconducting qubit readouts [ 50 ] . In this work, we anticipate that the Kerr-resonator thermometer enables high-precision temperature detection. Our study presents the physical mechanism by examining the probe’s purity in the steady state, and then we also examine the performance of actual Gaussian measurements. We investigate the effects of the Kerr nonlinearity coefficient and external single-photon driving on sensing performance. Specifically, we estimate the metrological potential of the resulting Kerr resonator thermometer using theoretical verification such as quantum Fisher information, and then we observe that increasing the controlling parameters such as Kerr nonlinearity coefficient and driving amplitude significantly improves the temperature estimation precision of our method. To enhance our analysis, we also investigate the underlying physical mechanism by examining probe purity in the steady state, and we specifically evaluate the performance of homodyne and heterodyne detections, demonstrating that neither of the two standard Gaussian measurements is optimal; however, optimal homodyne detection is always superior to heterodyne detection. Figure 1: A general sensing approach for measuring temperature or any other parameter connected with a reservoir at thermal equilibrium. This can be accomplished by temporarily connecting the sample with a probe; in the present case, the Kerr-nonlinear resonator is linearly coupled to a sequence of harmonic modes in a heat reservoir. These modes are in thermal equilibrium with a specific temperature ( T ). With this setting, the resonator serves as a probe for determining the temperature of the reservoir. Figure 2: \bar{n}_{\text{eff}} represents the effective temperature reached by a Gibbs state in the illustration, as described in Eq. ( 6 ). (a) n_{\text{th}}=0.05 , \chi=0.5\gamma , \delta=-3.5\gamma , \mathcal{E}=\gamma , (b) n_{\text{th}}=0.1 , \chi=0.5\gamma , \delta=-3.5\gamma , \mathcal{E}=\gamma , (c) n_{\text{th}}=0.05 , \chi=0.5\gamma , \delta=-3.5\gamma , \mathcal{E}=0.5\gamma , and (d) (c) n_{\text{th}}=0.1 , \chi=0.5\gamma , \delta=-3.5\gamma , \mathcal{E}=0.5\gamma . Scheme for Temperature Measurement.– First, let us introduce the model of the system that is employed in the current work to precisely measure the temperature of the reservoir. The generic model of a single-photon-driven dissipative Kerr-nonlinear resonator, which acts as our quantum probe for sensing environmental temperature. The Hamiltonian of a single-photon-driven Kerr-nonlinear resonator of frequency \omega_{a} in a rotating frame at the driving frequency \omega_{L} is given by (we set \hbar=1 hereafter) [ 51 ] \hat{H}_{\text{sys}}=\delta\hat{a}^{\dagger}\hat{a}+\chi\hat{a}^{\dagger}\hat{a}^{\dagger}\hat{a}\hat{a}+\mathcal{E}(\hat{a}+\hat{a}^{\dagger}), (1) where \delta=\omega_{a}-\omega_{L} is the cavity-pump detuning, \chi denotes the Kerr-nonlinearity strength, and \mathcal{E} is the amplitude of the single-photon drive. Here, \hat{a} and \hat{a}^{\dagger} are the annihilation and creation operators for photons inside the resonator,

Read the complete text