A Generalizable 3D Diffusion Framework for Low-Dose and Few-View Cardiac SPECT

Huidong Xie, Weijie Gan, Wei Ji, Xiongchao Chen, Alaa Alashi,Stephanie L. Thorn, Bo Zhou, Qiong Liu, Menghua Xia, Xueqi Guo, Yi-Hwa Liu, Hongyu An, Ulugbek S. Kamilov, Ge Wang, Albert J. Sinusas, Chi Liu · 2024

Read A Generalizable 3D Diffusion Framework for Low-Dose and Few-View Cardiac SPECT by Huidong Xie, Weijie Gan, Wei Ji, Xiongchao Chen, Alaa Alashi,Stephanie L. Thorn, Bo Zhou, Qiong Liu, Menghua Xia, Xueqi Guo, Yi-Hwa Liu, Hongyu An, Ulugbek S. Kamilov, Ge Wang, Albert J. Sinusas, Chi Liu (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-16573.txt.

Introduction

Huidong Xie and a large team build a diffusion reconstructor for perfusion scans that works across dose and view settings without retraining. SPECT imaging checks blood flow to the heart muscle, but cutting radiation dose or camera angles degrades the pictures. Earlier deep learning fixes were locked to the setting they trained on. Writing in twenty twenty-four, their framework generates three-dimensional images while a consistency strategy forces every sampling step to agree with the projections, the image data, and the scanner geometry. Detail from CT scans and a smoothness constraint guide the process, and a two-and-a-half-dimensional trick supplies whole-volume context within memory limits.

Validation covered over a thousand stress and rest studies from hundreds of patients, each rendered at several reduced-count levels. The authors report one model handling the range of settings, a flexibility clinics need when protocols vary by patient.

Catalog record

CREATORHuidong Xie, Weijie Gan, Wei Ji, Xiongchao Chen, Alaa Alashi,Stephanie L. Thorn, Bo Zhou, Qiong Liu, Menghua Xia, Xueqi Guo, Yi-Hwa Liu, Hongyu An, Ulugbek S. Kamilov, Ge Wang, Albert J. Sinusas, Chi Liu
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE61 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-16573

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Generalizable 3D Diffusion Framework for Low-Dose and Few-View Cardiac SPECT Huidong Xie, Weijie Gan, Wei Ji, Xiongchao Chen, Alaa Alashi,Stephanie L. Thorn, Bo Zhou, Qiong Liu, Menghua Xia, Xueqi Guo, Yi-Hwa Liu, Hongyu An, Ulugbek S. Kamilov, Ge Wang, Albert J. Sinusas, Chi Liu Abstract Myocardial perfusion imaging using SPECT is widely utilized to diagnose coronary artery diseases, but image quality can be negatively affected in low-dose and few-view acquisition settings. Although various deep learning methods have been introduced to improve image quality from low-dose or few-view SPECT data, previous approaches often fail to generalize across different acquisition settings, limiting their applicability in reality. This work introduced DiffSPECT-3D, a diffusion framework for 3D cardiac SPECT imaging that effectively adapts to different acquisition settings without requiring further network re-training or fine-tuning. Using both image and projection data, a consistency strategy is proposed to ensure that diffusion sampling at each step aligns with the low-dose/few-view projection measurements, the image data, and the scanner geometry, thus enabling generalization to different low-dose/few-view settings. Incorporating anatomical spatial information from CT and total variation constraint, we proposed a 2.5D conditional strategy to allow the DiffSPECT-3D to observe 3D contextual information from the entire image volume, addressing the 3D memory/computational issues in diffusion model. We extensively evaluated the proposed method on 1,325 clinical 99m {}^{\text{99m}} Tc tetrofosmin stress/rest studies from 795 patients. Each study was reconstructed into 5 different low-count levels and 5 different projection few-view levels for model evaluations, ranging from 1% to 50% and from 1 view to 9 view, respectively. Validated against cardiac catheterization results and diagnostic comments from nuclear cardiologists, the presented results show the potential to achieve low-dose and few-view SPECT imaging without compromising clinical performance. Additionally, DiffSPECT-3D could be directly applied to full-dose SPECT images to further improve image quality, especially in a low-dose stress-first cardiac SPECT imaging protocol. I Introduction Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide [ 1 ] . Cardiac single-photon emission computed tomography (SPECT) plays a crucial role in diagnosing CVDs [ 2 ] , and myocardial perfusion imaging (MPI) using SPECT remains the most widely performed procedure in nuclear cardiology [ 3 ] . Given the growing concern of radiation exposure and potentially increased cancer risks associated with SPECT scans, reducing the SPECT injection dose is desirable [ 4 ] . In addition, reducing image motion artifacts and patient discomfort through shorter scans as well as enhancing image quality on cost-effective scanners would also be beneficial in clinical settings. However, reducing the injection dose and scan duration can negatively affect image quality and diagnostic performance. Therefore, reconstructing clinically acceptable images from under-sampled measurement data is an important topic. In the context of this paper, under-sampled data refers to both low-dose and few-view data. Conventional iterative reconstruction methods fail to produce satisfactory images with under-sampled measurement data. Deep learning techniques have been actively researched to improve the quality of medical images [ 5 ] . Many different deep learning methods were proposed for SPECT image reconstructions/restorations under different acquisition conditions, including low-dose/low-count SPECT imaging [ 6 , 7 , 8 , 9 ] , and few-view/limited-angle SPECT imaging [ 10 , 11 , 12 , 13 ] . In particular, with the advancement of cutting-edge generative models [ 14 , 15 ] , diffusion models have demonstrated strong potential for improved nuclear imaging. While diffusion model has not been widely explored in the literature for SPECT imaging applications, it has achieved promising results for PET imaging. For example, building upon the Denoising Diffusion Probabilistic Model (DDPM) [ 16 ] , Gong et al., proposed to perform 2D PET image denoising with MRI as prior information [ 17 ] . A 3D diffusion model is desirable to process the entire image volume, but it is impracticable due to hardware memory limit. To address the 3D imaging problem with the diffusion model, our previous work [ 18 ] introduces DDPET-3D, a dose-aware diffusion model for 3D PET image denoising at different noise levels. Diffusion models have also been investigated for other imaging modalities [ 19 , 20 , 21 ] . However, most deep learning models were designed for a specific acquisition setting ( e.g. , low-dose or few-view), and struggle to generalize to other settings. For example, a low-dose imaging model typically fails to produce optimal results for few-view imaging, limiting their applicability in real clinical settings. The goal of this work is to introduce a diffusion framework for generalizable 3D SPECT imaging under different acquisition conditions (i.e., low-dose and few-view settings) without further network fine-tuning or re-training. Several challenges need to be addressed to achieve this goal. First , a model to consider 3D spatial information is desirable, as SPECT is intrinsically a 3D imaging modality. However, as mentioned previously, directly training a 3D diffusion model is challenging due to memory limitation. One may train a 2D diffusion and stack all the 2D slices together to generate the 3D image volumes. However, as demonstrated in our previous work [ 18 ] and later in this paper, this approach results in severe inconsistencies between different 2D slices along the Z-axis. Several previous works have attempted to address 3D imaging challenges in diffusion models. Chung et al. [ 22 ] proposed to incorporate a total variation (TV) constrain term along the z-axis to mitigate inconsistencies within each reverse sampling step in the diffusion model. Lee et al. [ 23 ] proposed to employ 2 pre-trained perpendicular 2D diffusion models to remove inconsistencies between slices. However, these two methods cannot observe 3D spatial information during the training process, leading to sub-optimal results. In contrast, our previous work proposed a 2.5D conditional strategy [ 18 ] , which allows the network to observe neighboring slices, and achieves better performance compared to the previous two methods. However, the previously proposed 2.5D conditional strategy can only observe adjacent n slices for image reconstructions, leading to a restricted receptive field, particularly at the edges of the image volumes. Second , another challenge in achieving generalizable SPECT image reconstructions under different acquisition conditions is the high variation of image artifacts. The images reconstructed from noisy projection data exhibit different noise patterns compared to those reconstructed from truncated projections. The noise patterns also vary across different low-dose and few-view levels. While training separate networks for different acquisition conditions is feasible, this approach is resource intensive and may not be practical due to the high variability of clinical protocols. Moreover, a model optimized for a specific setting may struggle to generalize effectively to unseen acquisition conditions, such as a low-count level that is not included in the training data. Therefore, a method to adaptively reconstruct images under different acquisition conditions is desirable. However, most of the previously proposed deep learning methods have limited generalizability to different acquisition conditions. To improve network generalizability, we previously proposed to combine multiple U-net-based [ 24 ] sub-networks with varying denoising power to generate optimal denoised results for any input noise levels [ 25 ] . In our previous low-dose PET diffusion paper [ 18 ] , we proposed to embed the injected dose within the diffusion model to achieve dose-aware PET denoising. We also attempted to adapt

Read the complete text