Cold source of atomic hydrogen for loading large magnetic traps

Aleksei Semakin, Janne Ahokas, Otto Hanski, Slava Dvornichenko, Tom Kiilerich, François Nez, Pauline Yzombard, Valery Nesvizhevsky, Eberhard Widmann, Paolo Crivelli, Sergey Vasiliev · 2024

Read Cold source of atomic hydrogen for loading large magnetic traps by Aleksei Semakin, Janne Ahokas, Otto Hanski, Slava Dvornichenko, Tom Kiilerich, François Nez, Pauline Yzombard, Valery Nesvizhevsky, Eberhard Widmann, Paolo Crivelli, Sergey Vasiliev (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-13981.txt.

Introduction

Aleksei Semakin and co-authors describe a cold source of hydrogen atoms in a 2024 physics paper. Experiments that trap huge numbers of hydrogen atoms need a strong, steady flow of very cold atoms. The team built a source that splits hydrogen molecules at near-freezing cold and then cools the atoms in stages.

Thin films of liquid helium coat the inner walls of each cooling stage. The source sends out a steady flow of atoms at temperatures near a tenth of a degree above absolute zero. The team used it to load a large magnetic trap and measured the load by the heat the atoms give off. Trapped atoms stayed stored for over 1,000 seconds, long enough for precise studies of cold hydrogen gas.

Catalog record

CREATORAleksei Semakin, Janne Ahokas, Otto Hanski, Slava Dvornichenko, Tom Kiilerich, François Nez, Pauline Yzombard, Valery Nesvizhevsky, Eberhard Widmann, Paolo Crivelli, Sergey Vasiliev
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE60 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-13981

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Cold source of atomic hydrogen for loading large magnetic traps Aleksei Semakin, Janne Ahokas, Otto Hanski, Slava Dvornichenko, Tom Kiilerich, François Nez, Pauline Yzombard, Valery Nesvizhevsky, Eberhard Widmann, Paolo Crivelli, Sergey Vasiliev Abstract We present a design and performance tests of an intense source of cold hydrogen atoms for loading large magnetic traps. Our source is based on a cryogenic dissociator of molecular hydrogen at 0.6 K followed by a series of thermal accommodators at 0.5, 0.2 and 0.13 K with inner surfaces covered by a superfluid helium film. All components are thermally anchored to corresponding stages of a dilution refrigerator. The source provides a continuous flux of 7 × 10 13 7\times 10^{13} H atoms/s in a temperature range of 130-200 mK. We have successfully used the source for loading a large Ioffe-Pritchard magnetic trap recently built in our laboratory [Ahokas et.al., Rev. Sci. Instr. 93 (2), 023201 (2022)]. Calorimetric measurements of the atomic recombination heat allow reliable determination of the atomic flux and H gas density in the trap. We have tested the performance of the source and loading of H atoms into the trap at various configurations of the trapping field, reducing the magnetic barrier height to 75 % \% and 50 % \% of the nominal value of 0.8 T (0.54 K) as well as at the open configuration of the trap at its lower end, when the atoms are in contact with the trapping cell walls covered by a superfluid helium film. In the latter case, raising the trapping cell temperature to 200-250 mK, the low-field seeking atoms at densities exceeding 10 11 cm -3 can be stored for the time over 10 3 s, sufficiently long for experiments on precision spectroscopy of cold H gas. 1 Introduction Experiments with hydrogen atoms were at the core of many discoveries in quantum physics and precision spectroscopy in the history of physics. The dispersion of atomic velocities due to the thermal motion is always a limitation for reaching highest resolution and accuracy. Obtaining an intense beam of slow hydrogen atoms or cooling trapped hydrogen gas is important for further improvements in optical, hyperfine and gravitational spectroscopy comparat2024 and for potential discoveries of new phenomena. Laser cooling routinely used for many other atoms and molecules is very difficult for hydrogen due its low mass and VUV range of the required excitation from the ground electronic state. Magnetic trapping and evaporative cooling are the methods which were successfully used for reaching quantum degeneracy and BEC in H gas in the end of the last century Fried1998 . Revisiting this techniques, we have recently built a large magnetic trap which is planned to be used for a variety of experiments with ultra-cold hydrogen atoms by the GRASIAN collaboration IPT_RSI . Loading such a trap requires an intense source of low-field seeking ( lfs ) atoms at sub-Kelvin temperatures. Here, we describe the design and operation of such a source and demonstrate its efficiency for a loading the magnetic trap. The source is based on a cryogenic dissociator operating at 0.65 K and a hydrogen transfer line covered by superfluid helium film and thermally anchored to different stages of a dilution refrigerator. A gradient of magnetic field separates low-field and high-field seeking ( hfs ) atoms. The source can be used as a stand-alone beam of slow hydrogen atoms. Elastic scattering from a superfluid helium covered surfaces can be utilized for further manipulation of the beam velocity and intensity. In Section 2 of this paper, we present a brief review of the cold atomic hydrogen sources and techniques used for various experiments, in Section 3 we describe shortly our experimental setup with a magnetic trap and a dilution refrigerator, Section 4 contains a description of the low-temperature hydrogen dissociator and hydrogen transfer line with the thermal accommodators. We present results of the tests of the source operation and loading the magnetic trap as well as of decay of the trapped gas in the Section 5. Finally, we analyze further improvements of the source for getting colder atoms with higher flux and suggest some ideas on the manipulation of the cold H beam using quantum reflection from a superfluid helium covered surface. 2 Background In the pioneering work of I. Silvera and J. Walraven Walraven1982 an intense cryogenic beam of H was obtained by dissociating H 2 at room temperature in the RF discharge and further thermal accommodation in a nozzle cooled by liquid helium. The atoms were cooled to \approx 8 K in collisions with the nozzle walls and a fairly large flux of \phi_{H}~\simeq~2.4~\times 10^{16} atoms/s was demonstrated. Such a cold nozzle technique was then used for high precision optical spectroscopy with atomic hydrogen Parthey2011 ; Matveev2013 ; Brandt2022 , microwave spectroscopy Diermaier2017 and experiments on quantum reflection of slow hydrogen beam Killian2023 ; Killian2024 . In these experiments the typical thermal distribution of atomic velocities after the nozzle corresponded to the temperature of \sim 6 K with a velocity peak at \sim 350 m/s. A special time-of-flight technique allowed a selection of slowest atoms in this distribution down to 50-60 m/s Cooper2020 ; Killian2024 . Further reduction was not possible due to the low intensity of the atomic flux and insufficient sensitivity of the detection system. The performance of the cold nozzle technique is limited by the recombination of atoms adsorbed on its wall which is strongly enhanced at low temperatures. It turned out that the only way to go further down in temperature is to use a superfluid helium film for the wall coverage which has the lowest adsorption energy of H \sim 1 K Safonov2001 ; cline1981 ; morrow1981 ; matthey1981 . This has been realized in experiments by I. Silvera and J. Walraven Silvera1980 where the atoms were stabilized in a sample cell covered by superfluid helium and located in a strong magnetic field of 7 T. The atoms were accumulated in a high-filed seeking ( hfs ) spin state which strongly suppressed recombination. In the follow up experiments H densities above 10^{17}~ cm -3 were reached at temperatures of 0.2-0.5 K Cline1980magnetic ; Hess1984 . At this stage of experiments with spin-polarized hydrogen, dissociation of molecular H 2 was performed at room temperature after which the atoms were transported into the 4 K nozzle and then in the low temperature region covered by a superfluid helium film. The superfluid film flow towards warmer regions, evaporating at \sim 1 K and re-condensing back onto the cold surfaces, created severe heat load on the dilution refrigerator. Also, the part of the H transfer line between the 4 K nozzle and the 1 K region, not covered by a superfluid helium film, had large losses due to the recombination. A much simpler method for producing cold H was introduced by W. Hardy at UBC Jochemsen1982 ; Statt1985 . They built a cryogenic H 2 dissociator in which dissociation of H 2 was performed in a cryogenic discharge below 1 K. This technique was later used by nearly all groups working with spin-polarized H. A typical flux of hfs H into the sample cell located in a strong magnetic field was 1-5 \times 10^{13} atoms/s at temperatures down to

Read the complete text