Properties of carbon-infused silicon LGAD devices after non-uniform irradiation with 24 GeV/c protons Journal: NIM A
C. Beirão da Cruz e Silva, G. Marozzo, G. Da Molin, J. Hollar, M. Gallinaro, M. Khakzad, S. Bashiri Kahjoq, K. Shchelina · 2024
Read Properties of carbon-infused silicon LGAD devices after non-uniform irradiation with 24 GeV/c protons Journal: NIM A by C. Beirão da Cruz e Silva, G. Marozzo, G. Da Molin, J. Hollar, M. Gallinaro, M. Khakzad, S. Bashiri Kahjoq, K. Shchelina (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-13780.txt.
Introduction
Beirão da Cruz e Silva and co-authors test silicon timing sensors after heavy proton exposure in a 2024 paper. The sensors, called LGADs, may time fast protons at colliders, but they must sit very close to the beam and take uneven doses of radiation. They report the first measures of current and voltage behavior after such uneven exposure, at very high total doses.
Catalog record
| CREATOR | C. Beirão da Cruz e Silva, G. Marozzo, G. Da Molin, J. Hollar, M. Gallinaro, M. Khakzad, S. Bashiri Kahjoq, K. Shchelina |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-13780
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Properties of carbon-infused silicon LGAD devices after non-uniform irradiation with 24 GeV/c protons Journal: NIM A C. Beirão da Cruz e Silva, G. Marozzo, G. Da Molin, J. Hollar, M. Gallinaro, M. Khakzad, S. Bashiri Kahjoq, K. Shchelina Abstract Forward proton spectrometers at high-energy proton colliders rely on precision timing to discriminate signal from background. Silicon low gain avalanche diodes (LGADs) are a candidate for future timing detectors in these systems. A major challenge for the use of LGADs is that these detectors must be placed within a few mm of the beams, resulting in a very large and highly non-uniform radiation environment. We present a first measurement of the current and capacitance vs. voltage behavior of LGAD sensors, after a highly non-uniform irradiation with beams of 24 GeV/c protons at fluences up to 1 × 10 16 p / c m 2 1\times 10^{16}p/cm^{2} . 1 Introduction At the CERN Large Hadron Collider (LHC), forward proton detectors rely on precision timing measurements to distinguish signal events from "pileup" (multiple collisions in the same bunch crossing) backgrounds. The CMS-TOTEM PPS and ATLAS-AFP projects pioneered precision proton timing in Run 2 of the LHC, using synthetic single-crystal diamond [ 1 , 2 , 3 , 4 , 5 , 6 , 7 ] and quartz Cherenkov [ 8 , 9 ] technologies, respectively. Initial studies were also performed with silicon low gain avalanche diode (LGAD) detectors [ 10 ] in 2017. Since the early LGAD studies, the technology has matured, and is now the choice for the endcap timing layer upgrades of the CMS and ATLAS experiments [ 11 , 12 , 13 ] . This also makes them an attractive candidate for use in forward proton detectors at the High-Luminosity LHC (HL-LHC) [ 14 ] . A major challenge for using LGADs in forward proton detectors is the radiation environment, which is both large and highly non-uniform, due to the proximity to the beam. While many previous studies have investigated the behavior of LGADs after irradiation with reactor neutrons or proton beams [ 15 , 16 , 17 , 18 , 19 , 20 , 21 ] , these have focused on the case of uniform irradiation, with a single device irradiated to a fixed amount. In this paper we aim to evaluate the behavior after highly non-uniform irradiation with high-energy protons, to understand whether a single device can be operated after very different internal radiation doses. 2 Radiation environment Forward proton detectors at the LHC are placed extremely close to the beam, at distances of a few mm. The sensor planes are oriented perpendicular to the beam, with one edge near the beam and the other edge farther away. This results in a highly non-uniform irradiation environment [ 22 , 14 ] , with more than an order of magnitude variation over distances of a few cm. At the High-Luminosity LHC, the sensors can be exposed to peak radiation doses of order 1\times 10^{16}p/cm^{2} in the region closest to the beam. In the worst case, with no other mitigations, this dose can be reached in 1 year of HL-LHC running, which is the timescale for exchanging damaged sensors. 3 LGAD sensors The LGAD sensors used for this study were produced by Fondazione Bruno Kessler (FBK), as part of the UFSD4 production. They have pixels of area 1.3\times 1.3\text{mm}^{2} , with a total area defined by an array of 5x5 pixels. An example of a 5x5 LGAD used for this study is shown in Fig. 1 . Figure 1: One 5x5 LGAD used for this study, photographed under a microscope. The 5x5 square array of pixels is visible, inside the guard ring. The rectangular areas are the IV probe contact points for the pixels and the guard rings. All of the sensors used in this study originate from wafer 18 of the FBK UFSD4 production, which was observed to be the most radiation hard of this production in uniform irradiation tests. These sensors are designed with a deep gain layer, enriched with carbon to help mitigate the acceptor removal effect produced by radiation [ 16 ] . The properties of UFSD4 and wafer 18 are discussed in more detail in Ref. [ 12 ] . In these sensors, a single bias voltage is provided to all pixels, as is typical of LGADs planned for the LHC experiments. This design imposes significant constraints on the HV operating point. The HV must be large enough that the most irradiated regions of the detector still perform well, but small enough that the least irradiated regions do not go into breakdown. 4 Irradiation conditions The irradiation was performed at the IRRAD facility [ 23 , 24 ] at the CERN Proton Synchrotron (PS). This provides high-intensity proton beams with a momentum of 24 GeV/c. In order to produce a non-uniform gradient, the sensors were offset from the beam center in both the horizontal and vertical directions (Fig. 2 ), creating a large variation in the dose along the diagonal going from the lower left to upper right of the sensor. Figure 2: Left: 5x5 LGAD sensor (seen before mounting at lower right) and frame used to mount the sensor for irradiation. The beam is centered at the center of the white square frame, with the sensor placed in the hole covered by kapton film. Right: Approximate positioning of sensors in the IRRAD beam. The squares indicate the positioning of the 5x5 LGAD device. The histogram indicates the beamspot shape during the period of irradiation, estimated from beam position monitoring data, with the colors indicating the relative intensity. Figure 3: Relative dose integrated in each pixel of the LGADs, compared to the most irradiated pixel. Each box in the plot represents a single 1.3\times 1.3\text{mm}^{2} pixel. The pixels for which IV curves are measured are shown by the dashed boxes at lower left, center, and upper right. The dimensions of the LGAD are approximate, and do not show the size of the guard ring or interpad spacing. A total of five sensors were tested. Two of the sensors were irradiated to reach a peak dose at the center of the beam corresponding to approximately 1\times 10^{16} p/cm 2 . Two other sensors were removed at the halfway point of the irradiation, resulting in a peak dose of approximately 5\times 10^{15} p/cm 2 . The remaining sensor was not irradiated, and served as a control sample. The actual dose was cross-checked using measurements of activated foils placed in the beamline. The dose measured at the center of the beam was found to be 3-11\% higher than the nominal target, with an uncertainty of 7%. The irradiation gradient was estimated from beam position monitoring (BPM) measurements at the IRRAD facility. These measurements were used to generate a two-dimensional representation of the beamspot, and the corresponding radiation profile within the sensors under test. As shown in Fig. 3 , there is approximately a factor of 2 in dose between the most irradiated pixel and the pixel at the center of the sensor, and a factor of 10 in dose between the most irradiated pixel and the least irradiated pixel. 5 Measurement conditions The measurements of the