Accurate and precise optical phase sensor based on a non-linear quantum Sagnac interferometer

Romain Dalidet, Laurent Labonté, Gregory Sauder, Sébastien Tanzilli, Anthony Martin · 2024

Read Accurate and precise optical phase sensor based on a non-linear quantum Sagnac interferometer by Romain Dalidet, Laurent Labonté, Gregory Sauder, Sébastien Tanzilli, Anthony Martin (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-13744.txt.

Introduction

Romain Dalidet, Laurent Labonté, Gregory Sauder, Sébastien Tanzilli, and Anthony Martin report a 2024 optical phase sensor built on a non-linear quantum Sagnac interferometer. Phase measures matter for tasks from tracking position and speed to judging traits of photonic waveguides, such as how light spreads in a fiber.

Their sensor is self-stabilized and built for both accuracy and precision, with results that repeat well. To show what it can do, they measured the chromatic dispersion of a commercial fiber made for telecom use. The spread of their readings was far tighter than the best tools they compare with.

Catalog record

CREATORRomain Dalidet, Laurent Labonté, Gregory Sauder, Sébastien Tanzilli, Anthony Martin
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-13744

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Accurate and precise optical phase sensor based on a non-linear quantum Sagnac interferometer Preprint: APS/123-QED Romain Dalidet, Laurent Labonté, Gregory Sauder, Sébastien Tanzilli, Anthony Martin Abstract Optical phase measurements play a key role in the detection of macroscopic parameters such as position, velocity, and displacement. They also permit to qualify the microscopic properties of photonic waveguides such as polarization mode dispersion, refractive index difference, and chromatic dispersion. In the quest for ever-better measurement performance and relevance, we report an original quantum non-linear interferometer based on a Sagnac configuration allowing precise, accurate, self-stabilized, and reproductible optical phase measurement. The potential of this system is demonstrated through the measurement of second-order dispersion, namely chromatic dispersion, of a commercial dispersion-shifted fiber at telecommunication wavelength. We assess precision by exhibiting a statistical error of 7.10 − 3 % 7.10^{-3}\,\% , showing more that one order of magnitude compares to state-of-the-art measurements. Additionally, the accuracy of the second-order dispersion value is determined through the measurement of the third-order dispersion, showing a quadratic error as low as 5 %. Our system promises the development of photonic-based sensors enabling the measurements of optical-material properties in a user-friendly manner. I Introduction Precise measurement is at the heart of science and technology Daryanoosh et al. 2018 . A fundamental concern lies in achieving the best precision in measuring optical phase, which impacts a large variety of domains encompassing gravitational wave detection,microscopy, and optical coherence tomography Jia et al. 2024 ; Ndagano et al. 2022 ; Abouraddy et al. 2002 . Quantum physics allows, in principle, ultimate precision achievable by exploiting correlated quantum resources, such as entangled states, offering significant advantages over even the most optimized iterations of classical counterparts Giovannetti et al. 2004 ; Moreau et al. 2017 . Quantum-enhanced optical phase estimation holds the promise of substantial improvements in all interferometry-based measurements Genovese 2021 . The central challenge, however, remains the stability of the interferometer itself. Environmental factors, such as temperature fluctuations and vibrations, introduce phase drifts that must be smaller than the variations being measured. Most of the interferometric phase measurements are based on Mach-Zehnder or Michelson interferometer architectures which require the use of sophisticated stabilization systems. The associated experimental complexity merely shifts the underlying challenge without fully resolving it Grassani et al. 2014 . In contrast, Sagnac interferometers are immune to phase drifts, as reciprocal phase shifts cancel out when the drift-rate is slower than the light propagation time, resulting in zero relative phase. This characteristic has greatly benefited the measurement of non-reciprocal phenomena, such as Faraday rotation and the gyroscopic effect, in both classical Culshaw 2005 and quantum Fink et al. 2019 regimes. Conversely, this configuration also finds limitations as Sagnac interferometers are inherently insensitive to chromatic dispersion (CD), a critical parameter for numerous photonics applications where both high precision and stability are essential Agrawal 1995 ; Fasel et al. 2004 . In this paper, we introduce an original interferometric architecture that integrates a novel type of non-reciprocity by embedding a non-linear element within the Sagnac loop. The latter grants access to previously unattainable parameters, such as the optical phase in the frequency domain, enabling precise CD measurements of the sample under test. We demonstrate several significant advantages: (i) the inherent system self-stabilization facilitated by a common path for all beams, (ii) a deterministic output for photons exiting the interferometer, unlike the typical 50% output Shi and Tomita 2004 , thereby reducing the overall loss budget of the system, and (iii) a straightforward alignment achieved through a fully fibered configuration operating at telecom wavelengths. Furthermore, the use of energy–time entangled photon pairs and coincidence counting to measure spectral correlation functions leads to non-local dispersion cancellation and the suppression of systematic errors Kaiser et al. 2018 . These advances collectively push the boundaries of precision and accuracy in CD measurements, positioning our approach at the forefront of both classical and quantum measurement techniques Fasel et al. 2004 ; Kaiser et al. 2018 ; Dalidet et al. 2023a . II Theory The schematic of the quantum non-linear Sagnac interferometer is shown in Fig. 1 . It comprises a common-path bulk configuration using a polarization beam splitter (PBS). The loop itself consists of a half-wave plate (HWP), a second-order non-linear medium, and a dispersive medium acting as sample under test (SUT). We assume that the path-difference between the non-linear medium and the PBS in both clockwise (CWi) and counterclockwise (CCWi) only comes from the dispersive medium. For the sake of clarity, we first consider the pump at frequency \omega_{p} to be vertically polarized. The latter propagates in the CWi path through the SUT and accumulates a phase denoted \phi_{p} . Subsequently, within the non-linear medium, it undergoes spontaneous parametric down conversion (SPDC) to generate photon pairs at the degenerate frequency \omega_{0}=\frac{\omega_{p}}{2} . A type-0 phase matching condition is achieved, ensuring polarization conservation between the pump and the generated paired photons. The latter then pass through the half-wave plate (HWP) to rotate their polarization to horizontal state. Finally, they exit through the pump arm, in opposite direction. As SPDC preserves the phase, the final state in the CWi path reads: |\psi_{cwi}\rangle_{si}=e^{i\phi_{p}}|HH\rangle_{si}\,, (1) where the subscripts s and i denote down-converted signal and idler photons. Conversely, if the pump is horizontally polarized, it propagates through the CCWi path. Figure 1: Principle of a non-linear Sagnac interferometer in free space configuration using a type-0 phase matched medium. The blue (red) path represents the propagation of the pump (pairs). HWP: half-wave plate; PBS: polarizing beam splitter; CWi: clockwise; CCWi: counter-clockwise; SUT: sample under test. The pump light first travels through the HWP to rotate its polarization and then undergoes down-conversion into the crystal. The paired photons pass through the SUT and exit the PBS through the pump arm. Thus, the final state in the CCWi path is given by: |\psi_{ccwi}\rangle_{si}=e^{i\phi_{s}+\phi_{i}}|VV\rangle_{si}\,. (2) Finally, we consider the pump to be diagonally polarized: |\psi_{in}\rangle_{p}=|D\rangle_{p}\equiv\frac{1}{\sqrt{2}}\bigl(|H\rangle_{p}+|V\rangle_{p}\bigr)\,, (3) where the subscript p denotes the pump. No relative phase between the horizontal and vertical polarization components is considered. Assuming that the SPDC efficiency is equal in both directions, the final state after propagation is the coherent superposition of equation 1 and 2 : \displaystyle|\psi_{out}\rangle_{si} \displaystyle=\frac{1}{\sqrt{2}}\Bigl[|HH\rangle_{si}+e^{i\Delta\phi}|VV\rangle_{si}\Bigr]\,, (4) \displaystyle\Delta\phi \displaystyle=\phi_{s}+\phi_{i}-\phi_{p}=(k_{s}+k_{i}-k_{p})L\,. (5) Here k and L denote the wavevector of the interacting photons and the length of the dispersive medium, respectively. Therefore, the photons are prepared in a maximally polarized entangled state, and the relative phase between the contributions to the state solely depends on the dispersive properties of the SUT. The phase imparted by the dispersive medium can be expressed as a Taylor expansion of the wavevector of the signal and idler photons around the degenerate frequency: \frac{\Delta\phi}{L}=-k_{p}+\sum_{k=i,s}\sum_{n=0}^{\infty}\frac{\Delta\omega^{n}_{k}}{n!}\beta^{(n)}\,, (6) where \beta^{(n)}=\left.\frac{\partial^{n}k}{\partial\omega^{n}}\right|_{\omega_{0}} and \Delta\omega stands for the detuning from \omega_{0} . The energy conservation of the non-linear process implies \Delta\omega_{s}=-\Delta\omega_{i} . Consequently, every odd-order term of the dispersion vanishes, a phenomenon called non-local dispersion cancellation Franson 1992 . By limiting the Taylor expansion to the second order, i.e. neglecting fourth-order dispersion, the relative phase carried by the entangled state reads: \begin{split}\Delta\phi&=(\beta^{(2)}\Delta\omega^{2}+2\beta^{(0)}-k_{p})L\\ &=\beta^{(2)}\Delta\omega^{2}L+\phi_{off}\,.\end{split} (7) Figure 2: Experimental setup for CD measurement using the non-linear Sagnac interferometer. An amplified and filtered telecom laser is injected into the Sagnac loop, which consists of the SUT

Read the complete text