Dispersive Qubit Readout of Temperature

Dong Xie, Chunling Xu · 2024

Read Dispersive Qubit Readout of Temperature by Dong Xie, Chunling Xu (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-13730.txt.

Introduction

Dong Xie and Chunling Xu ask whether squeezed light can sharpen temperature readings from qubits, in this 2024 paper. Reading a qubit through a cavity is sharper when squeezed light is injected. The team test if that gain extends to measuring temperature itself.

For qubits left alone after warming, precision can grow very fast under set limits. Those limits involve low temperature, short times, or few photons. In the general case, though, thermal noise blocks the squeezing gain. With many qubits kept in contact with a heat bath, best scaling returns if cavity loss is large. The results map when quantum tricks help thermometry and when heat wins.

Catalog record

CREATORDong Xie, Chunling Xu
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-13730

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Dispersive Qubit Readout of Temperature Dong Xie, Chunling Xu Abstract Squeezed light can exponentially increase the signal-to-noise ratio (SNR) of dispersive qubit readout, especially using a combination of injected external squeezing (IES) and intracavity squeezing (ICS). We further investigate whether IES and ICS can also exponentially improve the measurement precision of temperature. In the case of fully thermalized qubits isolated from thermal bath, the measurement precision of temperature can be improved exponentially when the temperature or measurement time or the input photon number approaches 0. In general, thermal fluctuations prevent the action of squeezed light. When multiple qubits maintain interacting with the thermal bath, the Heisenberg scaling can be achieved if the loss rate of the cavity is large and the coupling between the qubit and the optical cavity is weak enough. In the meantime, IES can also further promote the improvement of the measurement precision of the temperature exponentially. I Introduction In the field of quantum communication lab1 ; lab2 and quantum error correction lab3 , a common and powerful approach is dispersive readout where a qubit is strongly detuned from a cavity mode. By measuring the output cavity field quadratures, i.e., homodyne detection, high-fidelity readout can be obtained. In quantum metrology, squeezed light has been proved to improve the measurement sensitivity lab4 , such as, optomechanical motion sensing lab5 ; lab6 , and gravitational-wave detection lab7 ; lab8 . In order to expand the application of squeezed light to dispersive qubit readout, Barzanjeh et al. lab9 showed that an amplified interferometer can enhance the quality of dispersive qubit measurement. However, as the dispersive interaction will lead to a frequency-dependent rotation of the squeezing axis, the corresponding amplified noise prevents them from getting the Heisenberg scaling. In order to obtain the true Heisenberg-limited scaling, Ref. lab10 has showed that injecting two-mode squeezed light into two coupled cavities can exponentially improve the SNR. In the experiment lab11 , squeezed light has been used to reduce noise inside the signal to achieve higher SNR compared to that of coherent light readout in the same system. Recently, Qin et al. lab12 and Kam et al. lab13 proposed more suitable schemes of the standard dispersive readout, which used IES and ICS together to improve the SNR. Especially, Ref. lab12 has taken full advantage of squeezing to obtain that the resulting SNR can scale as e^{2r} for short-time measurements, rather than e^{r} in Ref. lab10 , where r refers to the squeezing parameter. Precise measurement of temperature is an important and significant subject in the field of quantum metrology lab14 ; lab15 ; lab16 ; lab17 ; lab18 , quantum thermodynamics lab19 and quantum simulations lab20 ; lab21 ; lab22 . Since squeezed light can be used to facilitate dispersive qubit readout, it is necessary to investigate whether IES and ICS can also exponentially improve the measurement precision of temperature. In this article, we try to utilize the dispersive qubit to measure the temperature of a thermal bath. Firstly, we consider that the qubit is completely thermalized after passing through a thermal bath with the temperature T and then weakly coupled to an optical cavity, and the temperature can be measured nondestructively by homodyne measurement. We find that the measurement precision of the temperature can be improved exponentially only when the measurement time tends to 0 or the temperature or the number of input photons goes to 0. Otherwise, neither IES or ICS can exponentially improve the measurement precision of the temperature. Then, we consider that N qubits remain in contact with the thermal bath in the process of the dispersive measurement. We show that the Heisenberg scaling can be obtained for small N in the case of large loss rate of the cavity and weak coupling between the qubits and the optical cavity. In the meantime, the measurement precision of the temperature can be improved exponentially by the squeezed light. When the number of qubits is large enough, increasing the number of qubits and the squeezing parameter will reduce the measurement precision of the temperature. No matter what the conditions are, increasing the number of input photons can always improve the measurement precision of the temperature. The rest of article is ranged as follows. In section II, the physical setup of the dispersive qubit readout is introduced and the measurement uncertainty of the temperature is obtained with IES. In section III, IES and ICS are used simultaneously for dispersive qubit readout of the temperature. The standard quantum limit is recovered in section IV. In section V, the dispersive measurement is performed in the case of N qubits continuously maintaining interaction with the thermal bath. We make a conclusion in section VI. II dispersive measurement with IES Figure 1: Diagram of dispersive qubit readout of temperature. The thermalized qubit with the temperature T is placed in a cavity, which is driven by IES denoted as a_{in} . By homodyne detection of the output mode a_{out} , the temperature T can be obtained. We utilize a setup where a qubit dispersively couples to a cavity to measure the temperature of a thermal bath, as shown in Fig. 1 . The dispersive setup is dominated by the Hamiltonian ( \hbar=1 ) lab23 \displaystyle{H}=\omega_{c}{a}^{\dagger}{a}+\frac{1}{2}\omega_{q}{\sigma}_{z}+\chi{\sigma}_{z}{a}^{\dagger}{a}, (1) where a (a^{\dagger}) denote annihilation (creation) operators of the cavity mode with the frequency \omega_{c} , \sigma_{z} is the Pauli matrix of the qubit with the transition frequency \omega_{q} , and \chi is the coupling strength between the qubit and the cavity mode. In a reference frame rotating at \omega_{c} , the quantum Langevin equation of the cavity mode {a} can be described by \displaystyle\dot{{a}}=-i(-i\kappa/2+\chi{\sigma}_{z}){a}-\sqrt{\kappa}{a}_{in}(t), (2) where \kappa denotes the cavity photon loss rate, and {a}_{in}(t) represents the input field of the cavity. Considering a squeezed vacuum reservoir, the correlations for the input-noise operator {A}_{in}(t)={a}_{in}(t)-\langle{a}_{in}(t)\rangle are given by \displaystyle\langle{A}_{in}(t){A}_{in}(t^{\prime})\rangle=\frac{1}{2}e^{i\phi}\sinh(2r)\delta(t-t^{\prime}), (3) \displaystyle\langle{A}^{\dagger}_{in}(t){A}^{\dagger}_{in}(t^{\prime})\rangle=\frac{1}{2}e^{-i\phi}\sinh(2r)\delta(t-t^{\prime}), (4) \displaystyle\langle{A}_{in}(t){A}^{\dagger}_{in}(t^{\prime})\rangle=\cosh^{2}(r)\delta(t-t^{\prime}), (5) \displaystyle\langle{A}^{\dagger}_{in}(t){A}_{in}(t^{\prime})\rangle=\sinh^{2}(r)\delta(t-t^{\prime}), (6) where r is the squeezing parameter and \phi denotes the reference phase. Firstly, we consider that the thermalized qubit is isolated from the thermal bath after time t=0 , so the system is always in thermal equilibrium \displaystyle\rho_{q}=\frac{\exp[-\frac{\omega_{q}}{2T}\sigma_{z}]}{\exp[-\frac{\omega_{q}}{2T}]+\exp[\frac{\omega_{q}}{2T}]}, (7) where we have already taken Boltzmann constant \beta=1 , and the temperature T of the thermal bath is what to be detected. In the rotating reference frame, the solution of Eq. ( 2 ) is analytically derived \displaystyle{a}(t)=\exp[\Lambda t]{a}(0)-\sqrt{\kappa}\int_{0}^{t}dt^{\prime}\exp[\Lambda(t-t^{\prime})]{a}_{in}(t^{\prime}), (8) where the parameter \Lambda=-i(-i\kappa/2+\chi{\sigma}_{z}) . The information of the temperature is encoded into output field of the cavity mode \displaystyle{a}_{out}(t)={a}_{in}(t)+\sqrt{\kappa}{a}(t). (9) For homodyne detection, the corresponding output quadrature Q is defined as \displaystyle{Q}(t)={a}_{out}(t)e^{-i\varphi}+{a}^{\dagger}_{out}(t)e^{i\varphi}, (10) where \varphi denotes the measurement angle. The essential parameter quantifying homodyne detection is the SNR, which is defined as lab24 \displaystyle\textmd{SNR}=\frac{|\langle M\rangle_{1}-\langle M\rangle_{0}|}{\sqrt{\langle M_{N}^{2}\rangle_{1}+\langle M_{N}^{2}\rangle_{0}}}. (11) where the time-integrated output quadrature M=\sqrt{\kappa}\int_{0}^{\tau}dt{Q}(t) with a measurement time t , the fluctuation noise operator M_{N}=M-\langle M\rangle , and the lower corner marks 1 and 0 labels the excited and ground states of the qubit. In the limits of \kappa\tau\rightarrow 0 and \kappa\tau\rightarrow\infty , Ref. lab12 obtained an exponential decrease in the measurement noise \displaystyle\langle M_{N}^{2}\rangle_{1}+\langle M_{N}^{2}\rangle_{0}\simeq 2\kappa\tau e^{-2r}. (12) It means that the SNR is improved exponentially. Next, we investigate whether the measurement precision of the temperature can also be improved exponentially. The error propagation