Updated version “Robust Voltage Regulation of DC-DC Buck Converter With ZIP Load via An Energy Shaping Control Approach”
Wei He, Yanqin Zhang, Yukai Shang, Mohammad Masoud Namazi, Wangping Zhou, Josep M. Guerrero · 2024
Read Updated version “Robust Voltage Regulation of DC-DC Buck Converter With ZIP Load via An Energy Shaping Control Approach” by Wei He, Yanqin Zhang, Yukai Shang, Mohammad Masoud Namazi, Wangping Zhou, Josep M. Guerrero (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-08898.txt.
Introduction
Wei He and co-authors design a controller to hold voltage steady in a buck converter that feeds a mixed load. Their 2024 paper, an updated version of earlier work, deals with ZIP loads, which blend constant impedance, current, and power parts. Such loads are common in power systems and can destabilize direct current networks.
The authors first build a controller that shapes the system's energy, assuming all disturbances are known. They estimate the range of states from which the system stays stable. A disturbance observer then rebuilds unknown shifts from parameter changes, and its estimates feed an adaptive version of the controller. Simulations and lab experiments test the design.
Catalog record
| CREATOR | Wei He, Yanqin Zhang, Yukai Shang, Mohammad Masoud Namazi, Wangping Zhou, Josep M. Guerrero |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 50 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-08898
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Updated version “Robust Voltage Regulation of DC-DC Buck Converter With ZIP Load via An Energy Shaping Control Approach” Wei He, Yanqin Zhang, Yukai Shang, Mohammad Masoud Namazi, Wangping Zhou, Josep M. Guerrero Abstract ZIP loads (the parallel combination of constant impedance loads, constant current loads and constant power loads) exist widely in power system. In order to stabilize buck converter based DC distributed system with ZIP load, an adaptive energy shaping controller (AESC) is devised in this paper. Firstly, based on the assumption that lumped disturbances are known, a full information controller is designed in the framework of the port Hamiltonian system via energy shaping technique. Besides, using mathematical deductive method, an estimation of the domain of attraction is given to ensure the strict stability. Furthermore, to eliminate the influence of parameter perturbations on the system, a disturbance observer is proposed to reconstruct the lumped disturbances and then the estimated terms are introduced to above controller to form an AESC scheme. In addition, the stability analysis of the closed-loop system is given. Lastly, the simulation and experiment results are presented for assessing the designed controller. I Introduction I-A Literature review DC-DC converters are often adopted as an interface between power supply and load to provide an appropriate working condition in practical applications, such as microgrid, ship power system, transportation vehicles, microprocessors [ 1 , 2 , 3 ] . A typical structure of microgrid system containing DC-DC converters is shown in Fig. 1 [ 4 ] . It is observed that new energy resources are regarded as generation unites, which provide power for domestic electrical installation and other applications. Wherein, DC-DC converters are installed to regulate the voltage of the ports between generation units and DC bus as well as DC bus and electrical equipments, which play an important role in power conversion. Hence, their control performance definitely affect the power quality of overall system [ 5 ] . It is noted that buck converter, which is one of an important part in the converters, is adopted to step down the voltage of output port [ 6 ] . It is necessary that an effective control strategy should be designed to regulate its output voltage with nice transient and steady state performance. Fig. 1 : A typical structure of DC microgrids. For the case of classical resistance load, its average model can be constructed as a second-order linear system. Obviously, there are a lot of remarkable results for dealing with the regulation problem of output voltage of buck converter under this kind of load in literature. For example, a switching control scheme based on energy conservation principle is reported in [ 7 ] to deal with the regulation problem of output voltage of the system. In [ 8 ] , the authors propose an adaptive terminal sliding-mode control for the system. Besides, a second-order sliding-mode control scheme is developed with the consideration of model uncertainties and external disturbances [ 9 ] . It is developed in [ 10 ] that an event-triggered model predictive controller is designed for it, which captures less computational burden and less switching actions. A simple current constrained control approach is proposed for the system to ensure that the inductor current does not go beyond the limit [ 11 ] . In this case, a higher reliability and safety can be obtained. In [ 12 ] , the authors propose a GPI observer-based robust control scheme to regulate output voltage around the equilibrium and reduce the affect of time-varying disturbances caused by load variation and input voltage fluctuation on the system, which obviously enhances the robustness. In [ 13 ] , an adaptive proportional-integral passivity-based controller (PI-PBC) without needing the information of the load is proposed for DC-DC converters on the basis of immersion and invariance technique. Additionally, a robust P leaky ID-PBC is developed for the system, which ensures that the system is exponentially stable and shows a high robustness against variable operating conditions [ 14 ] . To further improve the transient performance, an adaptive finite-time control method is developed for the system in the presence of unknown input voltage and load variations, which captures a faster regulation performance and stronger robustness [ 15 , 16 , 6 , 17 ] . The reviews about this topic can be found in [ 1 ] . With the increasing demand for flexible regulation, cascaded DC-DC converters exist in power system [ 18 ] . Internal interaction between the closely regulated converters will cause the appearance of constant power load (CPL). For the case of CPL, some advanced control methods are proposed to compensate negative impendence caused by it and ensure the stability of the system. In [ 3 , 19 ] , an adaptive energy shaping controller is devised for stabilizing buck converter with CPL, which obtains a satisfactory performance even if the load information is unavailable. In addition, to ensure the strict convergence, the estimation of attraction domain is presented. It is reported in [ 4 ] that an adaptive passivity based controller is designed for the system by integrating with a nonlinear disturbance observer. A nonlinear controller based on feedback linearization technique is proposed in [ 20 ] , in which a nonlinear reduced order observer is designed for estimating the power load. Besides, an improved interconnection and damping assignment passivity based control scheme is proposed by developing an adaptive interconnection matrix [ 21 ] . An offset-free model predictive controller is proposed for the system with a rigorous stability analysis by designing a higher order sliding mode observer, which shows a nice anti-disturbance performance under load variation and system uncertainties [ 22 ] . In [ 23 ] , the authors present a H ∞ based robust control scheme to deal with the control problem of the system. In [ 24 ] , the authors develop a composite robust discretized quasi-sliding mode control scheme for stabilization of buck converter fed dc microgrids with CPLs on the basis of large signal stability, which improves disturbance rejection and inherent chattering suppression. The authors in [ 25 ] proposes a power shaping control scheme for regulation problem of output voltage of the system. Designing a reduced-order generalized parameter estimation-based observer, an adaptive sensorless control scheme is developed for the system [ 26 ] . The implementation of the controller does not need the information of inductor current and power load. A deep learning based voltage controller is developed in [ 27 , 28 , 29 ] , which simples the control design. However, it results in high computational burden and requires high performance processors. The reviews about this topic can be found in [ 30 , 31 ] . Note that many loads in power systems, such as electronic devices and appliances, exhibit a nonlinear behavior. It is worth noting that ZIP load model allows for the representation of this non-linear behavior and accurately captures the load characteristics under different operating conditions, which is essential for ensuring accurate representation and analysis of the behavior and impact of various types of loads. In the case, it is developed in [ 32 ] that an adaptive nonlinear controller is proposed for buck converter with ZIP load by