Read Testbeam Characterization of a SiGe BiCMOS Monolithic Silicon Pixel Detector with Internal Gain Layer by and G. Iacobucci (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-07606.txt.
Introduction
Paolozzi and co-authors fire a pion beam at a new silicon pixel detector and read its report card. The prototype chip, built for the MONOLITH project, packs hexagonal pixels on a hundred-micron pitch with fast, quiet electronics in a silicon-germanium process. Its sensor grows a deep junction that multiplies the signal inside the silicon itself. Their 2024 testbeam campaign sweeps power and bias settings.
At the strongest bias and full power, the detector caught charged particles with near-perfect efficiency. Its timing precision reached about twenty-four picoseconds before corrections, and a standard correction improved it further. Numbers like these court the next generation of particle trackers, where position and time both matter. Detector physicists get a prototype that survived the beam with its promises intact.
Catalog record
| CREATOR | and G. Iacobucci |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-07606
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Testbeam Characterization of a SiGe BiCMOS Monolithic Silicon Pixel Detector with Internal Gain Layer and G. Iacobucci Abstract something 1 Introduction Monolithic Active Pixel Sensors (MAPS [ 1 ] ), which integrate the sensor and electronics within the same CMOS substrate, are becoming more and more common in particle physics. Despite their relatively complex design phase, MAPS provide all the benefits of standard CMOS processing while avoiding the production challenges and high costs associated with bump-bonded hybrid pixel sensors. A large surface of MAPS was recently installed in the ALICE experiment at the LHC [ 2 ] and is operated successfully. In the framework of the MONOLITH H2020 ERC Advanced project [ 3 ] , this group is developing very fast MAPS. Prototypes were produced using the commercial SG13G2 130 nm silicon-germanium (SiGe) BiCMOS process [ 4 ] by IHP Microelectronics, which includes a very fast and low-noise SiGe Heterojunction Bipolar Transistor (HBT) with a peak transition frequency f_{t} = 350 GHz. In a testbeam experiment with minimum-ionizing particles (MIPs), a prototype with a standard PN junction sensor without an internal gain layer produced with this technology provided full efficiency and time resolution of 20 ps [ 5 ] . Several of these prototypes were irradiated with 70 MeV protons up to a fluence 1\times 10^{16} n {}_{\text{eq}} /cm 2 and tested with radioactive sources [ 6 ] and in a testbeam experiment with MIPs [ 7 ] . The SiGe HBT front-end electronics not only survived such large proton fluence but was still able to recover full efficiency and provide a time resolution of 45 ps with only a modest increase in sensor bias voltage. This performance underscores SiGe HBT radiation tolerance, meeting the stringent requirements of the challenging High-Luminosity LHC environment. In parallel to the development of front-end electronics, the MONOLITH ERC project is also exploiting the picosecond avalanche detector (PicoAD) [ 8 ] , a novel detector that implements a continuous deep gain layer to boost the timing performance. A proof-of-concept monolithic PicoAD was produced in 2022 using the photolithography masks of a prototype able to provide 36 ps [ 9 ] with a sensor without internal gain layer. The proof-of-concept PicoAD was operated at a gain of approximately 20 [ 10 ] , obtaining full efficiency and an average time resolution of 17 ps [ 11 ] . The time resolution was found to depend strongly on the hit position on the pixel area, which varied between 13 ps at the center of the pixel and 25 ps in the inter-pixel region [ 11 ] . Recently, new PicoAD prototypes were produced using the photolithography masks of the ASIC that was characterized intensively in [ 5 , 12 , 6 ] . This paper presents the results of an experiment at the CERN SPS testbeam facility with the latest PicoAD prototype, in which both the time resolution and the efficiency were measured with 120 GeV/c pions. 2 Description of the ASIC The ASIC studied in this paper contains a matrix of 12 \times 12 hexagonal pixels of 65 \mu m side, corresponding to a pitch of approximately 100 \mu m, produced by IHP in the SG132G2 130 nm SiGe BiCMOS technology. It is an evolution of the previous prototype [ 9 ] , with improved front-end electronics. The ASIC contains four analog pixels (highlighted in red in Figure 1 ) in which the amplifier is connected to an analog driver to be read by an oscilloscope. The right panel of Figure 1 shows a schematic view of the front-end electronics and analog driver. Figure 1 : (Left) Layout view of the 2022 prototype ASIC. The four pixels in red are the analog pixels whose amplifier’s output is connected directly to an analog driver with differential output. (Right) Schematic view of the front-end electronics and driver configuration of the analog pixels. 3 PicoAD Production The PicoAD sensor has a multi-junction structure to engineer the electric field inside the silicon active area. The aim is to provide an electric field large enough to generate impact ionization and produce avalanche gain multiplication only of the electrons generated in a very thin zone ("absorption layer" in Figure 2 ), thus minimising the charge-collection (Landau) noise. The monolithic ASIC prototypes were manufactured by the Leibniz Institute for High Performance Microelectronics (IHP). Prior to CMOS processing, the PicoAD wafers were manufactured following the procedure explained in detail in [ 10 ] , that requires the following steps (from bottom to top in Figure 2 ): • first, an epitaxial layer of 3 or 5 \mu m was grown on a low resistivity silicon wafer; the primary electrons produced in this thin absorption layer will cross the gain layer and be multiplied, producing the fast component of the signal with minimal Landau noise; • then a gain layer was implanted, with several ion doses determined with a TCAD study; • finally, a second epitaxial layer of 15 or 25 \mu m (called "drift layer") was grown , which allows drifting of the primary electrons produced in the drift layer and the secondary electrons produced in the absorption layer toward the collection electrode (on the top of Figure 2 ). The wafers were then CMOS processed to produce the ultra-fast and low-noise electronics of [ 5 ] . Figure 2 : Layout view of the PicoAD prototype with hexagonal pixels with 65 \mu m side. Prototypes were produced in several flavours: four different gain-layer implant doses, thickness of the absorption layer of 3 and 5 \mu m, and thickness of the drift layer of 15 and 25 \mu m. All the results presented in this paper were obtained with the prototype with the largest implant dose, 5 \mu m absorption layer and 15 \mu m drift layer. A total of 15 different PicoAD flavors were produced with the two absorption and the two drift layer thicknesses and with different boron and arsenic implant doses of the gain layer. The testbeam data presented in this paper were taken with ASICs that have a PicoAD sensor with 5 \mu m-thick absorption layer, 15 \mu m-thick drift layer, and the highest dose implanted. It was found that, at temperature T = -5^{\circ} C, a bias voltage of 70 V was sufficient to fully deplete the sensors, while silicon breakdown occurred at 200 V. Prior to the testbeam, data were collected at the same temperature using 55 Fe and 90 Sr radioactive sources. These data were used to calculate the electron gain at various bias voltages and to convert the threshold values from mV to electrons. The results are summarized in Table 1 . 4 Testbeam Measurements 4.1 Experimental Setup Data were taken at the CERN SPS testbeam facility using pions with a momentum of 120 GeV/c. Figure 3 shows a schematic view of the experimental setup. It comprised: • the monolithic silicon ASIC device under test (DUT); • the UNIGE FE-I4 testbeam telescope [ 13 ] to reconstruct the tracks of the pions and give the trigger to the two oscilloscopes; • two Photonis PP2365AC micro-channel plate photomultiplier tubes (called MCP0 and MCP1) to provide a precise reference time, which were mounted outside the FE-I4 telescope downstream