Comparison of Deep Learning and Particle Smoother EM Methods for Estimation of Rb-82 Myocardial Perfusion PET Kinetic Parameters

2024

Read Comparison of Deep Learning and Particle Smoother EM Methods for Estimation of Rb-82 Myocardial Perfusion PET Kinetic Parameters (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-04706.txt.

Introduction

Myungheon Chin, Sarah Zou, Garry Chinn, and Craig Levin compare ways to read heart blood flow from PET scans, in a 2024 paper. The catalog record names no authors; the byline in the text gives the four names used here.

The tracer used, rubidium-82, fades fast, and fitting its motion gives flow values. The standard fitting method is fragile when some values must be fixed from population averages. The authors test two rivals: a particle smoother method and a neural network. On simulated scans, the network had the lowest errors on every parameter across frame lengths. It slipped when the input curves came from outside its training range. The smoother method helped one parameter but not others.

Catalog record

YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE45 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-04706

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Comparison of Deep Learning and Particle Smoother EM Methods for Estimation of Rb-82 Myocardial Perfusion PET Kinetic Parameters Abstract Background: Positron emission tomography (PET) enables quantification of dynamic physiological processes through time-resolved imaging. In 82 Rb myocardial perfusion PET, kinetic compartment modeling is used to estimate physiological parameters and derive myocardial blood flow. However, conventional nonlinear least squares (NLLS) estimation is sensitive to model misspecification when not all parameters can be reliably estimated and must instead be fixed or initialized using population averages, which can degrade accuracy. Purpose: This work develops and evaluates two alternative kinetic analysis approaches for 82 Rb PET: a particle smoother-based Expectation–Maximization method (PSEM) and a convolutional neural network (CNN). Methods: Both methods were evaluated using simulated 82 Rb dynamic myocardial perfusion studies and compared against NLLS and a Kalman smoother-based Expectation–Maximization (KEM) algorithm across multiple frame durations and noise levels. Results: Across 2–10 s frames, the CNN achieved the lowest relative errors for all parameters ( F F : 8.78–4.98%, k 3 k_{3} : 26.05–25.50%, k 4 k_{4} : 34.34–22.76%), significantly outperforming NLLS, KEM, and PSEM (Holm-adjusted p < 10 − 15 p<10^{-15} at 1.0 × \times noise, 2 s frames), although performance degraded under out-of-distribution input-function conditions. Conclusions: Overall, the CNN provided the most accurate and robust in-distribution kinetic parameter estimates across frame durations. In contrast, PSEM exhibited parameter-dependent behavior, improving k 3 k_{3} estimation while underperforming for F F , suggesting that further methodological refinement is needed. Myungheon Chin 1,2,∗ , Sarah J. Zou 1,2,∗ , Garry Chinn 2 , and Craig S. Levin {}^{1\text{--}3} 1 Department of Electrical Engineering, Stanford University 2 Department of Radiology, Stanford University 3 Departments of Bioengineering and Physics and Molecular Imaging Program at Stanford (MIPS), Stanford University ∗ These authors contributed equally to this work. Version typeset August 24, 2026 Author to whom correspondence should be addressed. email: [email protected] I . Introduction Positron emission tomography (PET) is a nuclear medicine imaging technique that measures the three-dimensional distribution of radiolabeled molecules, known as tracers. Dynamic PET uses time-resolved imaging data to produce time activity curves (TAC) for image voxels or specified regions of interest (ROIs) to estimate kinetic parameters such as cardiac flow and receptor binding rate constants. [ 4 ] . This paper examines the kinetic analysis of dynamic myocardial perfusion PET studies conducted with the tracer 82 Rb. Cardiovascular disease remains one of the leading causes of death worldwide, making accurate risk assessment and early identification of vulnerable patients critically important [ 32 ] . Dynamic positron emission tomography (PET) enables noninvasive imaging of the temporal dynamics of molecular processes in vivo [ 4 ] and provides functional information for the assessment of coronary artery disease (CAD) through quantification of regional myocardial blood flow (MBF) [ 18 , 39 , 16 , 27 , 45 , 41 ] . Several radiotracers are commonly used for PET-based MBF quantification, including 15 O-water, 13 N-ammonia, 82 Rb, 11 C-acetate, and 18 F-flurpiridaz [ 39 , 41 ] . Among these, 82 Rb is widely adopted in clinical practice because it is produced using an 82 Sr / 82 Rb generator and has a short half-life of 76.4 s, enabling multiple perfusion measurements within a single imaging session [ 45 , 41 ] . However, the short half-life necessitates rapid acquisition and leads to reduced signal-to-noise ratio. 82 Rb exhibits a relatively low and flow-dependent myocardial extraction fraction, resulting in a nonlinear relationship between tracer uptake and true MBF, particularly at higher flow rates and short acquisition frames further limit sensitivity to slower kinetic components [ 5 ] . By comparison, 13 N-ammonia offers higher and more stable extraction and a shorter positron range, yielding improved signal-to-noise ratio and more linear flow sensitivity, albeit requiring cyclotron production, whereas 15 O-water is an ideal freely diffusible tracer but presents logistical and modeling challenges due to its extremely short half-life [ 30 ] . Quantification of MBF via dynamic PET imaging requires appropriate kinetic modeling [ 14 , 28 , 43 ] . The radioactive isotope 82 Rb is typically modeled using a two-tissue compartmental model [ 18 , 16 , 45 ] . Estimating kinetic parameters in multi-tissue compartment scenarios often involves optimization challenges [ 14 , 28 , 4 , 43 ] , as these objective functions are not well conditioned and can have multiple local minima, complicating parameter estimation. Standard approaches like nonlinear least squares (NLLS) and graphical methods, such as the Patlak or Logan plots [ 35 , 26 , 43 ] differ primarily in their underlying assumptions and intended use cases. NLLS methods, though computationally demanding, offer estimation of micro-parameters at the cost of increased sensitivity to model assumptions, particularly in dynamic, low-count settings. Graphical approaches provide robust and precise estimates when their assumptions (e.g., irreversible trapping or equilibrium conditions) are satisfied and provide macro-parameter estimation. Graphical approaches are widely used for whole-body/total-body kinetic modeling [ 21 , 44 ] . In our study, we investigated two novel methods for estimating PET kinetic parameters by simulating a two-tissue compartmental model of 82 Rb and assessing their performance against the trust region-based NLLS method and a Kalman-smoother EM (KEM) benchmark. The KEM, similar to what Gibson and Ninnes described [ 11 ] , leverages the expectation-maximization (EM) algorithm, which iteratively alternates between estimating hidden states using the Kalman smoother [ 20 , 36 , 37 ] (E-step) and maximizing the Q function (M-step). The EM algorithm decomposes the multi-dimensional parameter solution space into a more manageable lower-dimensional optimization problem. The first novel method, the particle-smoother EM (PSEM), extends the EM algorithm by replacing the Kalman smoother with a particle smoother [ 12 , 38 ] . This provides greater flexibility as Kalman smoother requires unimodal Gaussian posterior distributions and the particle smoother allows for multimodal parameter distributions and nonlinear constraints. We hypothesize these properties could be advantageous under low-count, early-frame conditions or for more complex kinetic models. The second novel approach involves a convolutional neural network (CNN), a deep learning strategy that exploits spatial and temporal coherencies in datasets [ 23 , 1 ] . CNNs have shown strong performance in time-series analysis [ 10 ] and PET applications [ 42 , 17 ] . To our knowledge, this study represents the first application of a CNN to dynamic 82 Rb PET. We enhanced a traditional CNN model by incorporating a Time2Vec layer [ 22 ] to better capture temporal information. The CNN approach makes no assumptions about the underlying compartment model, allowing further flexibility in finding a mapping between PET activity and kinetic parameters. These methods were compared to assess their accuracy and efficiency in estimating PET kinetic parameters. II . Methods II . A . 2TC Model for 82 Rb PET C_{a}(t) q_{1}(t) Fast Exchangeable q_{2}(t) Slow Exchangeable F k_{3} k_{4} F/V1 Figure 1 : 2TC Model for 82 Rb: The inflow and outflow rates between the plasma and the fast exchangeable compartment are assumed to be equal ( F ), but the flow rate from the first state to the plasma is divided by V1 since q_{1}(t) is not a concentration but the total amount of the activity. Regional myocardial perfusion PET with 82

Read the complete text