Segmentation of Coronary Artery Stenosis in X-ray Angiography using Mamba Models
Ali Rostami, Fatemeh Fouladi, Hedieh Sajedi · 2024
Read Segmentation of Coronary Artery Stenosis in X-ray Angiography using Mamba Models by Ali Rostami, Fatemeh Fouladi, Hedieh Sajedi (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-02568.txt.
Introduction
Ali Rostami, Fatemeh Fouladi, and Hedieh Sajedi tested this 2024 use of a new sequence model to find narrowed heart arteries. Coronary artery disease is a top killer worldwide. Spotting the narrowed spots on X-ray angiograms is hard, since vessels are tangled, images are noisy, and tight spots look faint. The team tried models from the Mamba family, built for long sequences.
Five Mamba variants and one transformer variant, all shaped like the U-Net design, outlined the narrowed regions. The best model reached an F1 score of about sixty-nine percent. That beat a prior semi-supervised method by nearly twelve points. The study shows sequence models from language tech can help read heart images, though scores leave room to grow.
Catalog record
| CREATOR | Ali Rostami, Fatemeh Fouladi, Hedieh Sajedi |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-02568
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Segmentation of Coronary Artery Stenosis in X-ray Angiography using Mamba Models Ali Rostami, Fatemeh Fouladi, Hedieh Sajedi Abstract Coronary artery disease stands as one of the primary contributors to global mortality rates. The automated identification of coronary artery stenosis from X-ray images plays a critical role in the diagnostic process for coronary heart disease. This task is challenging due to the complex structure of coronary arteries, intrinsic noise in X-ray images, and the fact that stenotic coronary arteries appear narrow and blurred in X-ray angiographies. This study employs five different variants of the Mamba-based model and one variant of the Swin Transformer-based model, primarily based on the U-Net architecture, for the localization of stenosis in Coronary artery disease. Our best results showed an F1 score of 68.79% for the U-Mamba BOT model, representing an 11.8% improvement over the semi-supervised approach. I Introduction Coronary artery disease (CAD) is the foremost cause of mortality globally, responsible for claiming over 17 million lives annually [ 1 ] . CAD is essentially caused by the deposition of atherosclerotic plaque in epicardial arteries, which leads to a mismatch between the oxygen supply and demand in the myocardium, and usually increases the risk of ischemia [ 12 ] . This is usually when the coronary arteries, being some of the major blood vessels supplying blood and oxygen to the heart muscle, have become narrowed by the deposition and accumulation of fats, cholesterol, and other substances on the inner walls. This is also referred to as stenosis. This limits the amount of oxygen supplied to the heart to its oxygen demand, leading to ischemia. Heart failure and even death are the potential risks to the patient. CAD symptoms may include chest pain known as angina, shortness of breath and fatigue, which occur when the heart is deprived of an adequate supply of oxygen-rich blood. Early diagnosis of stenosis is crucial, and timely identification will improve cardiac function with a reduced risk of future cardiovascular complications. The diagnosis of coronary artery stenosis before depended on the combination of both noninvasive and invasive modalities. Noninvasive imaging modalities, such as computed tomography coronary angiography and magnetic resonance imaging, have been able to yield details on the anatomy of the coronary arteries, hence detecting stenosis without catheterization. Until now, the assessment methods for measuring the effect of stenosis on myocardial blood flow and cardiac function have primarily been stress tests and nuclear medicine myocardial perfusion imaging. In this paper, we use X-ray coronary angiography (XCA) images for detecting stenosis. To this day, coronary artery invasive angiography remains the gold standard for diagnosing stenosis in coronary arteries. This represents an invasive procedure in which a catheter is inserted into the coronary arteries and a dye is injected; the latter provides the ability to visualize the coronary arteries under X-ray imaging. This has allowed clinicians to identify and quantify with a high degree of accuracy the extent of arterial narrowing. Detailed visualization obtained by angiography makes the method very important in evaluating the extent of CAD and appropriately planning any intervention. On the other hand, coronary arteries having stenosis appear to be narrow and blurred in XCA so that they become hardly noticeable even for a doctor with several years of practice. Therefore, a computerized Artificial Intelligence (AI) method would allow a remarkable reduction in the expert cardiologist effort and time required, especially useful in the clinical setting for preliminary assessments or even more importantly as a supplementary review tool. Deep learning methods have recently shown very good results in the field of medical image analysis. Convolutional neural networks (CNNs) [ 18 ] are the first deep learning architecture designed specifically for images, they use a process of convolutional layers that automatically learn spatial hierarchies of features. These layers apply filters with small regions of the input data and capture patterns like edges and shapes at different levels of abstraction. CNNs have different layers, convolutional layers for applying filters to the input data, pooling layers for aggregating features and reducing the size of feature maps, and fully connected layers to use these extracted features for specific tasks. While CNN is based on convolutional operations, Transformer [ 22 ] updates the relative significance of some parts of the input through the attention mechanism. Thus, it gives more or less importance to the different words composing a sentence and improves its context and relationship understanding capability. Vision Transformers (ViTs) [ 5 ] are vision-specific and handle image patches as a sequence of tokens like words in a sentence. Such architectures demonstrate high performance in image classification, object detection, and segmentation tasks. Techniques utilizing CNNs for identifying stenosis from XCA images can be divided into approaches that analyze single frames and those that assess multiple frames. The first method analyze each frame separately [ 19 ] [ 23 ] [ 4 ] . A very recent prominent study presented a deep learning based methodology for the classification and localization of stenosis in XCA images of 194 patients [ 4 ] . Their approach used CNNs and Recurrent Neural Networks (RNNs) to achieve good performance on multiple tasks. In particular, the method achieved an Area Under the Curve (AUC) of 0.91 for the classification of both 3-category and 2-category stenosis in the right coronary artery (RCA), while in the left coronary artery (LCA), it attained 0.85 for the 3-category and 0.87 for the 2-category classification. Also, the sensitivity for stenosis detection was 0.72 for the RCA and 0.60 for the LCA, with mean square errors of 69.6 pixels for the RCA and 79.5 pixels for the LCA. It showed impressive performance for both classification and positioning of stenosis, which was the first indication of deep learning models’ capability for boosting the accuracy and reliability of CAD diagnosis. These traditional approaches overlook the temporal dynamics in XCA images, leading to potential difficulties in processing frames with suboptimal image quality Moreover, Transformers have shown excellent performance in medical imaging tasks because they can capture long-range dependencies and contextual information [ 9 ] . However, their associated computational complexity is a big challenge since it makes them hard to implement and places high requirements on computational resources, hence affecting their practicality, especially in a clinical setup where speed is necessary. In this study, we develop and evaluate multiple U-shaped segmentation models [ 21 ] to address the challenge of identifying stenosis in a dataset comprising 1500 X-ray angiograms. The majority of these models are based on Mamba [ 6 ] architecture, a novel sequence model that surpasses transformers in terms of linear computational complexity. These models were trained using a dataset [ 20 ] , in which experienced doctors identified the stenotic plaques using the SYNTAX Score definition. As per this definition, a stenosis with a thickness greater than 1.5 mm and 50% or more narrowing is labeled as a coronary lesion. II Related Work Stenosis detection from XCA images presents a real challenge given the complex and varied anatomy of coronary arteries, poor image quality, and small size of stenotic areas, which causes class imbalance in the segmentation task. Recent research has been directed toward developing the segmentation and localization of multivessel coronary artery stenosis from XCA images. Notably,