Read Effects of multiphoton states in the calibration of single-photon detectors based on a portable bi-photon source by S. Pani, D. Earl, F. E. Becerra 1 (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-02566.txt.

Introduction

Sujeet Pani, Duncan Earl, and Francisco Becerra probe a wrinkle in calibrating single-photon detectors with paired light, in a 2024 paper. The trick that makes the method clean is heralding: twins are born together, so one photon's click vouches for its partner. That partner becomes a standard candle for testing another detector's efficiency, with no reference lamp needed. The source here is a portable trade unit built on down-conversion.

The wrinkle is that the source sometimes sends more than a pair. Extra photons, mixed with the rig's losses, bend the count math and cap how true the calibration can run. The team models the squeezed light's counting pattern and shows the bend can be undone on paper, if the losses are known. Their read guides the design of field kits that grade detectors on site, to high accuracy, with no lab standard in tow.

Catalog record

CREATORS. Pani, D. Earl, F. E. Becerra 1
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE50 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-02566

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Effects of multiphoton states in the calibration of single-photon detectors based on a portable bi-photon source Preprint: AIP/123-QED S. Pani, D. Earl, F. E. Becerra 1 Abstract Single photon detectors (SPDs) are ubiquitous in many protocols for quantum imaging, sensing, and communications. Many of these protocols critically depend on the precise knowledge of their detection efficiency. A method for the calibration of SPDs based on sources of quantum-correlated photon pairs uses single photon detection to generate heralded single photons, which can be used as a standard of radiation at the single photon level. These heralded photons then allow for precise calibration of SPDs in absolute terms. In this work, we investigate the absolute calibration of avalanche photodiodes (APD) based on a portable, commercial bi-photon source, and investigate the effects of multi-photon events from the spontaneous parametric down conversion (SPDC) process in these sources. We show that the multi-photon character of the bi-photon source, together with system losses, have a significant impact on the achievable accuracy for the calibration of SPDs. However, modeling the expected photon counting statistics from the squeezed vacuum in the SPDC process allows for accurate estimation of the efficiency of SPDs, assuming that the system losses are known. This study provides essential information for the design and optimization of portable bi-photon sources for their application in on-site calibration of SPDs with high accuracy, without requiring any other reference standard. I Introduction Recent advances in optical quantum technologies have shown significant advantages over their classical counterparts Sidhu et al. 2021 ; Tse et al. 2019 ; Ono, Okamoto, and Takeuchi 2013 ; Arute et al. 2019 . Much of this progress has been enabled by breakthroughs in the efficient generation, manipulation, and detection of quantum states of light in the single photon regime Dello Russo et al. 2022 ; Chunnilall et al. 2014 . Among different technologies for the detection and characterization of quantum light, single photon detectors (SPD) are essential in diverse applications spanning quantum communications Liu et al. 2022 ; Bedington, Arrazola, and Ling 2017 , quantum metrology Taylor and Bowen 2016 ; Bhargav et al. 2021 ; Kück et al. 2022 , quantum imaging Madonini et al. 2021 , and photonic quantum computing Slussarenko and Pryde 2019 . The central role of SPDs in photonic quantum technologies also underscores the need for robust and accurate calibration techniques for reliable implementation of protocols relying on single photon detection Khomiakova, Kokhanenko, and Losev 2021 ; Madonini et al. 2021 ; Tsai et al. 2021 . Moreover, devising robust, repeatable, and accurate calibration techniques for SPDs can also facilitate efforts towards developing standards for photonic quantum technologies referenced to some defined primary standard, such as at National Metrology Institutes (NMIs) Tzalenchuk et al. 2022 . Among various performance metrics for SPDs Ware et al. 2007 ; Wayne, Bienfang, and Polyakov 2017 ; Ziarkash et al. 2018 ; Tao et al. 2020 , detection efficiency is critical in most photonic quantum technologies ETSI 2016 ; Mohageg et al. 2022 . This fact has driven many efforts to develop techniques for high accuracy calibration of the efficiency of SPDs at the single (or the few) photon level Chunnilall et al. 2014 . The most reliable calibration technique so far is the substitution method, in which the performance of an SPD, the detector under test (DUT), is compared to a reference detector whose calibration is traceable to some reference, such as a national primary standard Dhoska et al. 2016 ; Polyakov and Migdall 2007 ; Cheung et al. 2011 ; Jin, Gerrits, and Gamouras 2022 . Given its traceability, most of the other calibration techniques are usually evaluated relative to the substitution method Chunnilall et al. 2014 . An alternate approach, first proposed by Klyshko Klyshko 1980 , makes use of the photon correlations from photon pair sources and single-photon heralding detection to prepare heralded single photons. These heralded photons work as an accurate source of radiation to calibrate an SPD. The Klyshko method in principle can be used to determine the efficiency of an SPD in absolute terms. High accuracy calibration of SPDs based on this method has been realized within national laboratories of standards and metrological institutes Migdall et al. 2002 ; Ware et al. 2007 ; Polyakov and Migdall 2007 ; Gerrits et al. 2020 , where spontaneous parametric down conversion (SPDC) in nonlinear crystals was used as a source of correlated photon pairs. These demonstrations used specialized equipment and required involved system calibration and characterization, which is difficult to realize outside these metrological institutes. Moreover, while the Klyshko method assumes ideal heralded single photons in a single mode, the heralded quantum state from SPDC can significantly deviate from this assumption Hellebek, Mølmer, and Sørensen 2024 . All this puts in question the practicality and applicability of this method using SPDC for high accuracy efficiency calibration of SPDs in settings outside specialized metrology laboratories. Figure 1: Schematic of (a) the conventional calibration method (the substitution method) and (b) the Klyshko calibration method. The conventional calibration method is implemented by calibrating the input photon flux with a reference standard detector, which is then substituted by the detector under test (DUT) to determine its detection efficiency. The Klyshko method uses correlated photon pairs to simultaneously calibrate two detectors, D1 and D2. The two photons from each pair are directed to separate single photon detectors. The detection efficiency of the DUTs can be determined in absolute terms by comparing the coincidences C_{12} with the single photon counts from the other detector C_{1(2)} (heralding detector). In this work, we investigate the feasibility of the Klyshko method for the absolute calibration of SPDs without requiring traceability to reference standards for its application outside metrological institutes. We employ a commercial portable bi-photon source based on SPDC Qubitekk 2024 , and use coincidence counting to determine the detection efficiency of commercial avalanche photodiode (APD) SPDs in absolute terms. We theoretically analyze the effects of the underlying properties of the squeezed vacuum state from the SPDC process in the Klyshko method, which ultimately limits the calibration accuracy of SPDs. Finally, we compare the APD detection efficiencies obtained from the Klyshko method with those from the conventional substitution method. This comparison allows us to investigate the effects of non-ideal system conditions on the performance of the Klyshko method. We observe that multi-photon states from SPDC and the overall system losses have a significant impact on the accuracy of the Klyshko method. This investigation provides an understanding of the required system performances for deployable SPDC sources for reliable on-site absolute calibration of SPDs with high accuracy. II Background The conventional approach for high accuracy calibration of SPDs has mostly relied on comparisons with a transfer standard detector traceable to a primary standard in metrological institutes Migdall et al. 2002 ; Ware et al. 2007 ; Polyakov and Migdall 2007 ; Gerrits et al. 2020 . A primary standard of optical power, such as a cryogenic radiometer, is used to calibrate the responsivity of the reference detector Biller et al. 1999 ; Fox and Rice 2005 ; Müller et al. 2012 , which functions as a secondary standard for calibrating the SPD. Figure 1 (a) depicts the main concept

Read the complete text