High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles
Zechuan Yin, Justin J. Welter, Connor A. Hart, Paul V. Petruzzi, Ronald L. Walsworth · 2024
Read High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles by Zechuan Yin, Justin J. Welter, Connor A. Hart, Paul V. Petruzzi, Ronald L. Walsworth (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-02040.txt.
Introduction
Zechuan Yin and co-authors report a 2024 physics paper on sensing weak magnetic signals with spins in diamond. Tiny defects called nitrogen-vacancy centers can detect narrowband fields with fine detail, but standard methods work only below about 20 megahertz. The team wanted the same sharp detail across a much wider band.
Their method mixes the signal with a quantum effect in a dense set of centers, then reads the result in a synced way. It covered signals from 10 megahertz to 4 gigahertz, with detail finer than one hertz and a low noise floor. Phase was read with error under one degree. The wider range opens uses in radio signal imaging and in magnetic resonance work on small samples.
Catalog record
| CREATOR | Zechuan Yin, Justin J. Welter, Connor A. Hart, Paul V. Petruzzi, Ronald L. Walsworth |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 35 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-02040
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles Zechuan Yin, Justin J. Welter, Connor A. Hart, Paul V. Petruzzi, Ronald L. Walsworth Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 \lesssim{20}\, MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ <1^{\circ} . Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples. I Introduction Figure 1: (a) Wide frequency range RF sensing using an NV ensemble in diamond. The NV electronic spin state is controlled through application of a laser optical field, coupled to the diamond surface via total internal reflection (TIR), and microwave (MW) signals applied through an MW loop. The NV spin state population is read out by measuring the state-dependent photoluminescence (PL) collected through an objective. An AC bias field, applied through the same coil as the target RF signal, is used to generate an effective (detected) signal in the optimal frequency range ( \approx 1\, MHz) of a narrowband NV sensing protocol via quantum frequency mixing (QFM). (b) NV - energy-level diagram. The negatively charged NV center in diamond exhibits spin-dependent PL with triplet ground-state spin transitions. (c) QFM technique implemented within a coherently averaged synchronized readout (CASR) sensing protocol. A target RF signal at frequency \omega_{s} is mixed, via the nonlinear response of the NV electronic spin system, with a strong AC bias field at frequency \omega_{b} , with both fields transverse to the NV axis. The resulting effective signal at frequency \omega_{e}=\omega_{s}-\omega_{b} aligns with the NV quantization axis. The CASR protocol, comprising repeated, synchronized dynamical decoupling sequences, reads out the effective signal at a sampling rate of \omega_{SR} , aliasing the measured NV PL to a signal with a frequency \omega_{a} , and providing sub-Hz resolution in the frequency domain after performing an FFT. The precise measurement of weak narrowband (AC) magnetic fields is crucial for a wide range of applications, including communications [ 1 , 2 ] , fundamental physics [ 3 ] , cosmology [ 4 ] , and nuclear magnetic resonance (NMR) spectroscopy and imaging [ 5 , 6 ] . In recent years, quantum sensors based on solid-state spin-defects, such as nitrogen-vacancy (NV) centers in diamond [ 7 ] , have demonstrated an exceptional combination of sensitivity and spatial resolution for narrowband magnetometry, with diverse applications in the physical and life sciences [ 8 , 9 ] . Moreover, advances in quantum spectroscopy protocols, such as the coherently averaged synchronized readout (CASR) technique [ 10 ] bypass the measurement limitation of sensor spin relaxation and coherence times, enabling phase-sensitive narrowband measurements with high spectral resolution (sub-Hz), paving the way for applications such as NMR spectroscopy and imaging of samples at the micro- and nanoscales [ 11 , 12 , 13 , 14 ] . However, most narrowband NV-diamond sensing protocols, including CASR, are based on dynamical decoupling sequences [ 15 , 16 ] that limit the accessible signal to a low frequency range (typically <20\, MHz), constrained by requirements on the amplitude and speed of microwave (MW) control pulses used to manipulate NV electronic spins [ 17 , 18 , 19 ] . Alternatively, implementations of continuous dynamical decoupling techniques like spin-lock Rabi can extend the sensing frequency range to \sim{85}\, MHz [ 20 , 21 ] , but have reduced sensitivity relative to pulsed techniques and the frequency range is still limited by the MW control field amplitude. Other techniques such as Rabi magnetometry [ 22 , 23 ] enable low-spectral-resolution ( \sim{} kHz) narrowband sensing within a frequency range of about 300 MHz from the NV spin transition frequencies ( \sim{3} GHz at low applied DC bias magnetic field), but are not applicable to intermediate signal frequencies ( \sim{100}\, MHz to 2 GHz) or the high frequency range ( >4\, GHz) unless applying a strong DC bias field ( \sim{0.1} T) to tune the NV spin resonances. Recently, a quantum frequency mixing (QFM) effect was proposed to convert narrowband magnetic signals from previously inaccessible frequency regimes into the optimal detection range of NV sensing protocols, with a proof-of-principle experimental demonstration of a 150 MHz test signal with spectral resolution \sim{10} kHz [ 24 ] . Subsequently, QFM-based Rabi magnetometry was demonstrated in a wide-field NV ensemble imaging modality with \sim{10} kHz spectral resolution [ 25 ] . As summarized below, the QFM approach exploits the nonlinear response of the NV electronic spin system to both a target RF signal (at arbitrary frequency) and an applied strong AC bias field (detuned by \sim{1} MHz from the target signal) to yield an effective signal at the difference frequency of the signal and bias fields: the target signal is thereby ”mixed down” to a frequency that is well-matched to the NV sensor. In this work, we demonstrate a QFM spectroscopy protocol that operates over a wide signal frequency range (10 MHz to 4 GHz); and can be integrated with CASR to provide sub-Hz spectral resolution, nT noise floor, and precise phase measurements ( <1^{\circ} error). We begin with assessing the narrowband magnetic sensitivity of the QFM-CASR protocol for several target signal frequencies across the large detection range, showing good agreement between experimental measurements and theoretical estimation. We then highlight the protocol’s wide-frequency capability and high spectral resolution by measuring the spectra of multi-frequency signals at 0.6, 2.4, and 4 GHz with fine spectral features, separated by 1 Hz. Furthermore, we demonstrate that the protocol is sensitive to the signal phase by performing a phase measurement at 2.4 GHz with a standard deviation of 0.4 ∘ . II Results II.1 QFM-CASR spectroscopy protocol Figure 2: Sensitivity assessment of QFM-CASR narrowband magnetometry across a wide target signal frequency range of 10 MHz to 4 GHz. The AC bias field is detuned 1 MHz from the target signal frequency; and has constant amplitude \Omega_{b}=(2\pi)4.3\, MHz. The red and blue curves represent estimated QFM-CASR sensitivity for our experimental setup, based on the measured XY8-6 sensitivity for a 1 MHz signal frequency (purple diamond) and Eq. ( 3 ), for the applied MW pulses on resonance with NV spin transition frequencies \omega_{-1}=(2\pi)2.29\, GHz and \omega_{+1}=(2\pi)3.45\, GHz, respectively.