XY Factorization Bias in Luminosity Measurements

Anna Fehérkuti, Péter Major, Gabriella Pásztor · 2024

Read XY Factorization Bias in Luminosity Measurements by Anna Fehérkuti, Péter Major, Gabriella Pásztor (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-01310.txt.

Introduction

Anna Fehérkuti, Péter Major, and Gabriella Pásztor gauge a skew in beam-bright reads in a 2024 paper. Bright, the rate of grain clashes, must be known to a hair for fine work, and a famed scan sets the mark.

The scan parts the beams step by step, first side then up, and reads the clash rate at each step. From the two one-line reads hands build the full face, on faith that the face splits clean in two. The trio tests that faith on a year of clash data from a great ring. They weigh the fit forms, hunt skews, and pin the mend and its doubt. The mend feeds the mark's last word on bright for that run.

Catalog record

CREATORAnna Fehérkuti, Péter Major, Gabriella Pásztor
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-01310

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

XY Factorization Bias in Luminosity Measurements Anna Fehérkuti, Péter Major, Gabriella Pásztor Abstract For most high-precision experiments in particle physics, it is essential to know the luminosity at highest accuracy. The luminosity is determined by the convolution of particle densities of the colliding beams. In special van der Meer transverse beam separation scans, the convolution function is sampled along the horizontal and vertical axes with the purpose of determining the beam convolution and getting an absolute luminosity calibration. For this purpose, the van der Meer data of luminometer rates are separately fitted in the two directions with analytic functions giving the best description. With the assumption that the 2D convolution shape is factorizable, one can calculate it from the two 1D fits. The task of XY factorization analyses is to check this assumption and give a quantitative measure of the effect of non-factorizability on the calibration constant to improve the accuracy of luminosity measurements. We perform a dedicated analysis to study XY non-factorization on proton-proton data collected in 2022 at s = 13.6 \sqrt{s}=13.6 TeV by the CMS experiment [ 1 ] . A detailed examination of the shape of the bunch convolution function is presented, studying various biases, and choosing the best-fit analytic 2D functions to finally obtain the correction and its uncertainty. keywords luminosity; high-energy physics; accelerator physics; collider physics; CERN CMS; data analysis. PACS PACS numbers: † † catchline: Vol. , No. () – † † history: Received Day Month YearRevised Day Month Year 07.05.Kf, 29.20.-c, 29.20.D-, 29.27.-a, 29.27.Bd, 29.27.Fh, 29.90.+r 1 Introduction 1.1 What is luminosity? The instantaneous luminosity ( \mathcal{L}_{\mathrm{inst}} ) is an important quantity in experimental particle physics. It is proportional to the frequency of physical processes, therefore it can be measured as the fraction of the observed rate of some quantity ( R ) and a corresponding detector-dependent (calibration) parameter, the so-called visible cross-section ( \sigma_{\mathrm{vis}} ). On the other hand, luminosity can be expressed using the colliding beam parameters: \mathcal{L}_{\mathrm{inst}}=\frac{R}{\sigma_{\mathrm{vis}}}=\frac{fN_{1}N_{2}}{2\pi\Sigma_{\mathrm{x}}\Sigma_{\mathrm{y}}}, (1) with the machine revolution frequency f\approx 11245 Hz, the bunch populations ( N_{1,2} ), and the horizontal and vertical beam overlap sizes ( \Sigma_{\mathrm{x,y}} ). These widths are measured using the so-called van der Meer (vdM) scans [ 2 ] . 1.2 About vdM scans in a nutshell At the Large Hadron Collider (LHC) two bunches (from oppositely circulating beams) collide. In vdM scans these bunches are separated with well-defined distances within the transverse (x,y) plane, resulting in different rates measured by a detector, depending on the amount of overlap between the bunches (ie. how head-on the collisions are). Changing these transverse separation distances the vdM scans provide a rate distribution along the axes as R(0,y)\quad\mathrm{and}\quad R(x,0). (2) The nominal separation values for the on-axis vdM scans are shown in Fig. 1 , together with that of other, special off-axis scans (more details in the next section). Figure 1: Nominal transverse beam separations (defined by the currents of the LHC dipole corrector magnets) in X and Y directions during scans to illustrate the different scan types performed in 2022. The separation points (the distances by which the beams are separated) for vdM scans in X and Y directions are shown in blue, while for the off-axis scan points are marked in red. The latter ones belong to (in order from left to right) offset, diagonal and mini-diagonal scans. Then the on-axis vdM data is separately fitted in the two directions with some variations of the Gaussian function, from which the best fitting one is chosen and used ultimately for each scan. From these fits a width parameter ( \Sigma_{\mathrm{x,y}} ) is obtained, from which the \sigma_{\mathrm{vis}} can be calculated as \sigma_{\mathrm{vis}}=\int\int R(x,y)\mathrm{d}x\mathrm{d}y\sim 2\pi\cdot\frac{\max_{\mathrm{x}}R(x,0)+\max_{\mathrm{y}}R(0,y)}{2}\cdot\Sigma_{\mathrm{x}}\Sigma_{\mathrm{y}}. (3) 1.3 The XY Factorisation Bias In Eq. 3 , however, the approximation is exact only if the convolution shape is factorizable, meaning that R(x,y)=f_{1}(x)\cdot f_{2}(y) (4) stands. This assumption was shown to be violated in previous CMS measurements, see e.g. Ref. [ 2 ] and necessitates the correction of the emerging XY factorization bias. One possibility to measure this bias quantitatively is to combine the on-axis with off-axis scan data to obtain a more complete grid (as it is shown in Fig. 1 ) mapping the two-dimensional (2D) surface of the measured rates (shown in Fig. 2 respectively to Fig. 1 ). Figure 2: Visualization of the HFET data at the scan points connected by 1D single Gaussian fits in on-axis vdM (blue) and off-axis (red) scan pairs. A simultaneous 2D fit is performed in each case to the luminometer rates to study the shape and the factorization property of the beam overlap area. These points then can be fitted in 2D and the value for the bias can be obtained from a simulation based on the fitted shapes. 2 Analysis The analysis workflow in details is presented through the example of the 2022 proton-proton dataset collected at 13.6 TeV collision energy [ 1 , 3 ] . 2.1 Input data Following the aforementioned method based on off-axis scans to sample the tails of the beam overlap are for obtaining a quantitative measure for the factorization bias, the analysis uses the following scan data (referring to labels shown in Fig. 3 ). All off-axis scans are exploited, including the offset [ 4 ] , the diagonal [ 5 ] , and both mini-diagonal scans. Each of them is paired with one or two close-by on-axis vdM scans from vdM2-vdM4 to minimize the effect due to the changing beam conditions with time. Figure 3: Nominal transverse beam positions (defined by the currents of the LHC dipole corrector magnets) as a function of time during LHC fill 8381. The labels of the various scan pairs are also given. Each scan pair contains two scans orthogonal to each other (e.g. horizontal vdM2X and vertical vdM2Y). Abbreviations: short on-axis vdM-like ”emittance” scan (ES), super-separation with no overlap between the beams (SS), on-axis van der Meer scan (vdM), beam imaging scan with a stationary and a scanning beam (BI), off-axis diagonal scan (diag), mini-diagonal scan (mini), offset scan (offs), constant length scale scan with the two beams moving in the same direction (cLS). When several scans of the same type are performed, a number also follows the abbreviations to create unique labels. During the time gap between 5:36 and 10:36 CMS was taking head-on data. The input data already contains various corrections obtained from the CMS BRIL [ 6 ] vdM framework (FW) dedicated to the analysis of beam scan data, in particular, the background contribution to the rates, e.g., from detector noise; the contribution from so-called ghost and satellite [ 2 ] charges to the bunch intensities; the beam orbit based on measurements by the LHC beam position monitors; and the transverse position length scales are taken into account. The effect of the electromagnetic interactions between the bunches [ 1 , 7 ] was estimated to be small compared to other sources of bias and is not considered further. 2.2 Analysis flow The analysis flow contains many steps and throughout cross-checks at each one. As the first step, 1D fits (regarding only one transverse scan direction at a time) are performed, similarly to the FW, but also evaluated for the off-axis

Read the complete text