Characterization of more than three years of in-orbit radiation damage of SiPMs on GRBAlpha and VZLUSAT-2 CubeSats

Jakub Řípa, Marianna Dafčíková, Pavel Kosík, Filip Münz, Masanori Ohno, Gábor Galgóczi, Norbert Werner, András Pál, László Mészáros, Balázs Csák, Yasushi Fukazawa, Hiromitsu Takahashi, Tsunefumi Mizuno, Kazuhiro Nakazawa, Hirokazu Odaka, Yuto Ichinohe, Jakub Kapuš, Jan Hudec, Marcel Frajt, Maksim Re · 2024

Read Characterization of more than three years of in-orbit radiation damage of SiPMs on GRBAlpha and VZLUSAT-2 CubeSats by Jakub Řípa, Marianna Dafčíková, Pavel Kosík, Filip Münz, Masanori Ohno, Gábor Galgóczi, Norbert Werner, András Pál, László Mészáros, Balázs Csák, Yasushi Fukazawa, Hiromitsu Takahashi, Tsunefumi Mizuno, Kazuhiro Nakazawa, Hirokazu Odaka, Yuto Ichinohe, Jakub Kapuš, Jan Hudec, Marcel Frajt, Maksim Re (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2411-00607.txt.

Description

A 2024 arXiv research paper by Jakub Řípa, Marianna Dafčíková, Pavel Kosík, Filip Münz, Masanori Ohno, Gábor Galgóczi, Norbert Werner, András Pál, László Mészáros, Balázs Csák, Yasushi Fukazawa, Hiromitsu Takahashi, Tsunefumi Mizuno, Kazuhiro Nakazawa, Hirokazu Odaka, Yuto Ichinohe, Jakub Kapuš, Jan Hudec, Marcel Frajt, Maksim Re. Silicon photomultipliers (SiPMs) are prone to radiation damage which causes an increase of dark count rate. This leads to an increase in low-energy threshold in a gamma-ray detector combining SiPM and a scintillator.

Catalog record

CREATORJakub Řípa, Marianna Dafčíková, Pavel Kosík, Filip Münz, Masanori Ohno, Gábor Galgóczi, Norbert Werner, András Pál, László Mészáros, Balázs Csák, Yasushi Fukazawa, Hiromitsu Takahashi, Tsunefumi Mizuno, Kazuhiro Nakazawa, Hirokazu Odaka, Yuto Ichinohe, Jakub Kapuš, Jan Hudec, Marcel Frajt, Maksim Re
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE48 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2411-00607

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Characterization of more than three years of in-orbit radiation damage of SiPMs on GRBAlpha and VZLUSAT-2 CubeSats Jakub Řípa, Marianna Dafčíková, Pavel Kosík, Filip Münz, Masanori Ohno, Gábor Galgóczi, Norbert Werner, András Pál, László Mészáros, Balázs Csák, Yasushi Fukazawa, Hiromitsu Takahashi, Tsunefumi Mizuno, Kazuhiro Nakazawa, Hirokazu Odaka, Yuto Ichinohe, Jakub Kapuš, Jan Hudec, Marcel Frajt, Maksim Rezenov, Vladimír Dániel, Petr Svoboda, Juraj Dudáš, Martin Sabol, Róbert László, Martin Koleda, Michaela Ďuríšková, Lea Szakszonová, Martin Kolář, Nikola Husáriková, Jean-Paul Breuer, Filip Hroch, Tomáš Vítek, Ivo Veřtát, Tomáš Urbanec, Aleš Povalač, Miroslav Kasal, Peter Hanák, Miroslav Šmelko, Martin Topinka, Hsiang-Kuang Chang, Tsung-Che Liu, Chih-Hsun Lin, Chin-Ping Hu, Che-Chih Tsao Abstract Silicon photomultipliers (SiPMs) are prone to radiation damage which causes an increase of dark count rate. This leads to an increase in low-energy threshold in a gamma-ray detector combining SiPM and a scintillator. Despite this drawback, they are becoming preferred for scintillator-based gamma-ray detectors on CubeSats due to their low operation voltage, small size, linear response to low light intensity and fast response. This increasing popularity of SiPMs among new spaceborne missions makes it important to characterize their long-term performance in the space environment. In this work, we report the change of the dark count rate and low-energy threshold of S13360-3050 PE multi-pixel photon counters (MPPCs) by Hamamatsu, using measurements acquired by the GRBAlpha and VZLUSAT-2 CubeSats at low Earth orbit (LEO) spanning over three years. Such a long measurement of the performance of MPPCs in space has not been published before. GRBAlpha is a 1U CubeSat launched on March 22, 2021, to a 550 km altitude sun-synchronous polar orbit (SSO) carrying on board a gamma-ray detector based on CsI(Tl) scintillator readout by eight MPPCs and regularly detecting gamma-ray transients such as gamma-ray bursts and solar flares in the energy range of ∼ 30 − 900 \sim 30-900 keV. VZLUSAT-2 is a 3U CubeSat launched on January 13, 2022 also to a 535 km altitude SSO carrying on board, among other payloads, two gamma-ray detectors similar to the one on GRBAlpha. We have flight-proven the Hamamatsu MPPCs S13360-3050 PE and demonstrated that MPPCs, shielded by 2.5 mm of PbSb alloy, can be used in LEO environment on a scientific mission lasting beyond three years. This manifests the potential of MPPCs being employed in future satellites. 1 Introduction Silicon photomultipliers (SiPMs) are arrays of avalanche photodiodes (APDs) operating in Geiger mode which are capable of registering individual photons [ 2019NIMPA.926…16A , 2019NIMPA.926….2P , 2019NIMPA.926…36K , 2011NIMPA.656…69V ] . Their low operation voltage, small size, linear response to the input low light intensity and fast response comparable to classical photomultiplier tubes make them favourable for scintillator-based gamma-ray detectors, particularly on CubeSats and small spaceborne instruments with limited volume and power. However, it is well known that SiPMs are prone to radiation damage. For example work [ 2003NIMPA.512…30L ] describes the radiation damage effects in silicon detectors irradiated by hadron and gamma radiation and discusses the impact on detector properties and microscopic defects. For a review of the radiation tolerance of SiPMs see work [ 2019NIMPA.926…69G ] . Several experiments has shown that radiation-damaged SiPMs have deteriorated performance [ 2023ITNS…70..150S , 2023NIMPA104567488A , 2023NIMPA104767791A , 2023ExA….55..343M , 2021NIMPA.98864798M , 2019ITNS…66.1833B ] . With the increasing popularity of SiPMs among new spaceborne missions it is of paramount importance to characterize their performance in space, e.g. the evolution of their dark count rate or sensitivity energy range of a scintillator-based detector which employs SiPMs. A number of new X-ray/gamma-ray missions for high-energy astrophysics which utilize SiPMs in their detectors are being developed, have recently been launched or are planned. Therefore, in-orbit measurements of the radiation-induced ageing of SiPMs over several years is highly valuable. Current and future CubeSats, larger missions and instruments using SiPMs for detection of gamma-ray transients, such as gamma-ray bursts (GRBs) [ 2006RPPh…69.2259M ] are for example [ 2022hxga.book…19B , 2021Galax…9..120F ] : BurstCube [ 2017ICRC…35..760P ] , EIRSAT-1 [ 2021ExA….52…59M , 2022ExA….53..961M ] , GALI [ 10.1117/12.3019170 ] , GARI [ 2023SPIE12678E..15M ] , GECAM/GRD [ 2023NIMPA105668586Z ] , GlowBug [ 2022SPIE12181E..1OW ] , GRBAlpha [ 2023A&A…677A..40P ] , GRBBeta [ 10.1117/12.3025855 ] , GRID [ 2019ExA….48…77W ] , GTM [ 2022AdSpR..69.1249C ] , MAMBO [ 2022SPIE12181E..2LB ] , POLAR-2 [ 2025arXiv250107758K ] , SIRI [ 2019SPIE11118E..0IM ] , StarBurst [ 2024NIMPA106469329W ] or VZLUSAT-2 [ 2020SPIE11530E..0ZD ] . The SIRI-1 instrument on board the STPSat-5 on low Earth orbit (LEO) reported a significant and constant increase of leakage current over one year of J-series SensL 60035 SiPMs used in their detector [ 2021NIMPA.98864798M ] . GRID-02 CubeSat characterized the ageing of ON Semiconductor MicroFJ-60035-TSV SiPMs in orbit over three months and also reported a significant and gradual increase of the dark current [ 2022NIMPA104467510Z ] . In this work, we report the characterisation of the in-orbit ageing of S13360-3050 PE multi-pixel photon counters (MPPCs) produced by Hamamatsu Photonics K.K. 1 1 1 https://www.hamamatsu.com/jp/en.html using the measurements acquired by the GRBAlpha and VZLUSAT-2 CubeSat missions at LEO spanning over three years for the first time. It has to be mentioned that the radiation-damaged SiPMs can be greatly recovered by increasing their temperature, so-called annealing [ 2023NIMPA104867934D , 2023NIMPA105368381G , 2021NIMPA.98664673H ] . The long-term annealing of SiPMs also occurs at room temperature. If a gamma-ray detector on a CubeSat at LEO is not actively cooled the SiPMs can reach this temperature. Moreover, the altitude of CubeSats can decrease significantly over a few years at LEO due to orbital decay which leads to the change of radiation conditions 2020SPIE11444E..3PR . Therefore, it is interesting to study the behaviour of SiPMs over a long time in orbit. We add that a recent experiment has shown that it is possible to significantly recover the energy threshold of radiation-damaged SiPMs by using a current waveform amplifier, by a coincidence sum of the signal from two SiPMs attached to the same scintillator and operating at low temperature [ 2024NIMPA106169097M ] . This article is organized as follows: Sec. 2 introduces the GRBAlpha and VZLUSAT-2 CubeSats and their GRB detectors. Sec. 3 describes the used methods. Sec. 4 presents the obtained results, Sec. 5 discusses the results and Sec. 6 summarises the main conclusions of this work. 2 GRBAlpha and VZLUSAT-2 CubeSats Figure 1: Left: GRBAlpha with marked GRB detector and position of the lead shielding protecting MPPCs (adopted with modification from 2020SPIE11444E..4VP ). Right: VZLUSAT-2 during integration with marked one of the two GRB detectors and position of the lead shielding covering MPPCs. The second GRB detector on VZLUSAT-2 is placed at the bottom and is not visible in this photo (modified photo provided by the Czech Aerospace Research Centre). GRBAlpha 2 2 2 https://grbalpha.konkoly.hu is a 1U CubeSat launched on March 22, 2021, to a 550 km altitude sun-synchronous polar orbit (SSO) [ 2023A&A…677A..40P , 2020SPIE11444E..4VP ] detecting hard X-ray / gamma-ray transients such as GRBs, soft-gamma repeaters and solar flares. The detector consists of a 75\times 75\times 5\,{\rm mm} CsI(Tl) scintillator read out by eight MPPCs S13360-3050 PE by Hamamatsu, arranged into two independent readout channels with four MPPCs connected in parallel in each readout channel. The sensitivity range covered \sim 30-900 keV at the beginning

Read the complete text