System Advisor Model (SAM) Maddy Crouse National Laboratory of the Rockies August 2025 This presentation was produced when the laboratory operated as the National Renewable Energy Laboratory (NREL). The laboratory is now the National Laboratory of the Rockies (NLR). What Does SAM Do? • The System Advisor Model (SAM) is a free software that enables detailed performance and financial analysis for energy systems. • Conducts technoeconomic analysis of energy technologies to facilitate planning and decision- making. • Evaluates or compares the energy production or cost of installed systems, various system configurations, or incentive structures (NREL, 2024). Images: NREL, PR-5600-90876, 2024 National Laboratory of the Rockies | 2 Technologies and Financial Models Photovoltaic Financial Models Power purchase agreements Technologies Energy storage Single owner Electric battery Partnership flips Electric thermal storage Sale leaseback Concentrating solar power Residential Industrial process heat Commercial Marine energy Third party ownership Wind power Merchant plant Fuel cell Community solar Geothermal power Simple LCOE calculator Solar water heating Biomass combustion Generic system Photos: Werner Slocum, 74146, NREL and Joe DelNero, 90984, NREL PLUS: HYBRID SYSTEMS National Laboratory of the Rockies | 3 Who Uses SAM? • Lawmakers and utilities to study how a policy would affect the economics of a typical system or to analyze different types of utility rate structures for generation sources. • Developers and engineers to compare technologies, sites, or configurations, or to estimate the Levelized Cost of Energy for a system. • Researchers to examine how an innovative concept might be able to lower the Levelized Cost of Energy or to estimate the technical potential of a technology in a region. • Students to learn about energy or to explore financing structures for energy. SAM can be used within other tools at NREL; dGen, PVWatts, REopt, HOPP, reV, ReEDS, PLEXOS. Source: NREL 2024 National Laboratory of the Rockies | 4 What Kinds of Questions Can SAM Answer? • What system configuration will maximize earnings from electricity sales? • What incentive structure will be most effective during implementation of new energy systems? • How will installing a new technology change the cost of energy and system efficiency compared to the current system? • What kind of system can I design to maximize localized energy production for an industrial electricity client? • How can I add photovoltaics (PV) to my existing wind plant to maximize my interconnection agreement? • How can I take advantage of various complementary energy generation resource profiles at my location? • How can I use localized energy generation sources to complement my (fill in the blank) generation (using the generic system model)? Source: NREL 2024 National Laboratory of the Rockies | 5 Getting Started with SAM How to Access and Use SAM • SAM is available as a desktop application as well as programmatically through a variety of languages, including a popular Python wrapper. • SAM is an open-source project (programmers can contribute) implemented in C++. • NREL typically updates the tool about once a year. • Highly tailored analysis can benefit from an experienced analyst, although it can be learned by newer analysts as well. • Reach out to sam.support@nlr.gov for assistance or to be connected with the team. Source: NREL, PR-5600-90876 National Laboratory of the Rockies | 7 Data Parameters: Input • Weather data- Temperature range, common weather events, etc. Sources can be found here. ◦ Example: One-minute weather data obtained from NREL’s Measurement and Instrumentation Data Center. • System specifications- Generation capacity, efficiency, etc. ◦ Example: The community energy system includes a 1.5 megawatt solar array with an inverter efficiency of 96% and battery storage sized to support critical loads for up to four hours. (Source: NREL PR-6A20-64987, 2015) • System losses- System losses capture phenomena that are not explicitly handled by the model, including availability and O&M downtime and other technology-specific losses. ◦ Example: Inverter downtime is a major source of PV system production loss, often exceeding the utility–scale financial model assumption of 1% production loss. (Source: NREL/CP-5K00-76022, 2020) • Compensation- Offsetting electricity usage and selling excess generation back to the grid (subject to utility rate and billing structures) for behind-the-meter systems and power purchase agreements or market participation for front-of-meter systems. ◦ Example: Customers with rooftop solar receive bill credit for excess energy they send back to the grid (NREL/PR-5600-90876, 2024). National Laboratory of the Rockies | 8 Data Parameters: Inputs Continued • Financing Incentives o SAM can model three types of incentives: ▪ Tax credits ▪ Depreciation (tax deduction) ▪ Cash payments. o Incentives may be provided by different institutions, including: ▪ Federal government ▪ State and local government ▪ Utilities ▪ Others. o Rules for incentives depend on who provides them. SAM is general enough to model most types of incentives. It does not automatically choose options based on the provider of the incentive. (Gilman, 2024). ▪ Example: The state of Tennessee offers an incentive that rebates 100% of sales and use tax on photovoltaics in addition to other renewable technologies (Diorio et al., 2018). National Laboratory of the Rockies | 9 Data Parameters: Results • This is a selection of some results; more are available in the tool. ◦ System output estimate- process of estimating how much energy a system can produce ◦ Revenue- income generated by the sales of goods and services ◦ Simple payback period- the minimum time it takes to recover an investment. The simple payback period for an energy system is the total investment cost divided by the first year's revenues from energy saved, displaced, or produced (NREL, 2000) ◦ Capacity factor- the ratio of the annual average energy production (kWhAC) of an energy generation plant divided by the theoretical maximum annual energy production of a plant assuming it operates at its peak rated capacity every hour of the year ◦ Levelized cost of energy- a summary metric that combines the primary technology cost and performance parameters: capital expenditures, operating expenditures, and capacity factor (NREL, n.d.) ◦ Net present value- is the total economic value expected to be produced by a system when its lifecycle costs are subtracted from the energy bill savings it will generate (NREL, 2025) National Laboratory of the Rockies | 10 SAM Resources • Introduction and support videos: ◦ Introduction to SAM ◦ Video series ◦ Modeling Incentives • Active forum for questions and engagement • Monthly 30-minute online round tables for questions about using SAM or feedback on new features Virtual conferences periodically: ◦ Events • Access tool • Email: sam.support@nlr.gov National Laboratory of the Rockies | 11 Case Study Hawaii • Objective: Evaluate the most cost-effective system configuration out of following options: ◦ No PV ◦ PV only ◦ PV plus direct current- (DC-) coupled battery ◦ PV plus alternating current- (AC-) coupled battery (Diorio et al., 2018) ◦ Learn more about AC and DC power AES Lawai Solar Project- Kauai Photo: Dennis Schroeder, NREL National Laboratory of the Rockies | 13 Assumptions System Assumptions Cost, and Electric Rate Assumptions • Residence in Honolulu • PV system costs: $2.92/Wdc [1] • Peak annual load 3.4 kilowatts (kW) • Storage costs: $2000/kW [2] • Proposed • Financial assumptions taken as SAM o 4.7 kW PV array (two strings of seven defaults, except for Hawaii specific taxes modules) and incentives (Diorio et al., 2018) o DC/AC ratio 1.23 (3.8 kWac inverter) o 5 kW/24 kilowatt-hours (kWh) lithium- ion battery system • Self-consume all PV to qualify for Hawaii Electric Company Customer Self Supply, otherwise must qualify for Customer Grid Service • No charging of battery from the grid is allowed Photo: Dennis Schroeder, NREL National Laboratory of the Rockies | 14 Hawaii Electric Company Customer Programs Chart: Diorio et al., 2018) https://www.hawaiianelectric.com/clean-energy-hawaii/producing-clean-energy/customer-renewable-programs National Laboratory of the Rockies | 15 Example of Daily Operation • When the PV DC power output exceeds the inverter DC power input, excess power is clipped. • In an AC connected system, even if PV power is dumped to the battery, it doesn’t reduce clipping, since PV power must still pass through the inverter before going to the battery. • In a DC connected system, PV power can be dumped to the battery before passing through the inverter. PV + AC-Connected Battery PV + DC-Connected Battery Source: NREL/PR-6A20-71779 National Laboratory of the Rockies | 16 Results Comparison • Net present value is the total economic value expected to be produced by a system when its lifecycle costs are subtracted from the energy bill savings it will generate. o Installing no system is the worst option o Installing PV only is the best option, if the customer can qualify for the limited Customer Grid Supply option. o Installing a DC-connected battery mitigates all PV clipping, but it provides approximately the same return as an AC- connected battery in this case. Source: NREL/PR-6A20-71779 National Laboratory of the Rockies | 17 Sensitivity: Boost DC to AC Ratio • Added string of seven PV modules to the inverter, boosting DC/AC ratio to 1.85. • 13% boost in net present value over AC battery system, since PV system produces a lot of excess DC power that cannot be captured by AC connected battery. • Possible reasons for high DC/AC ratio include levelizing system AC output throughout day, keeping plant AC output consistent over module lifetime, etc. Source: NREL/PR-6A20-71779 National Laboratory of the Rockies | 18 References Corrigan, Annie, Matt Henry. 2024. ”Overview of Tools to Provide Support for State Energy Programs.” Golden, CO: National Renewable Energy Laboratory. https://docs.nrel.gov/docs/fy24osti/90876.pdf. Diorio, Nicholas, Janine Freeman, and Nate Blair. 2018. DC-connected Solar Plus Storage Modeling for Behind-the- Meter Systems in SAM. Presented at2018 WPEC-7 and 45th IEEE PVSC. Golden, CO: National Renewable Energy Laboratory. https://docs.nrel.gov/docs/fy20osti/71779.pdf. GTM Research. 2018. “U.S. Energy Storage Monitor: 2017 Year in Review and Q1 2018 Full Report.” GTM Research Report 2018. Keith, Janine. 2024. “Modeling Hybrid Power Systems in SAM.” National Renewable Energy Laboratory. https://sam.nrel.gov/images/webinar_files/sam-webinars-2024-hybrid-systems.pdf. M. Hand, W. Cole, M. Maness, A. Eberle, et. al “2017 Annual Technology Baseline, National Renewable Energy Laboratory 2017. https://atb-archive.nrel.gov/electricity/2017/index.html OpenEI. 2018. “International Utility Rate Database.” Accessed May 12, 2018. https://openei.org/apps/IURDB/rate/view/5927424d 682bea6484cfded4. U.S. Department of Energy. "War of the Currents: AC vs. DC Power." Last modified November 18, 2014. https://www.energy.gov/articles/war-currents-ac-vs-dc-power. National Laboratory of the Rockies | 19 This work was authored by the National Laboratory of the Rockies for the U.S. Department of Energy (DOE), operated under Contract No. DE-AC36-08GO28308. Funding