A U.S. DEPARTMENT OF ENERGY NATIONAL LAB • SAVANNAH RIVER SITE • AIKEN, SC • USA Tank 48H Phase 1 Initial Testing: As- Received Characterization of HTF-48-25- 17 E. J. Craig September 2025 SRNL-STI-2025-00506, Revision 0 This work was prepared under an agreement with and funded by the U.S. Government. Neither the U.S. Government or its employees, nor any of its contractors, subcontractors or their employees, makes any express or implied: 1. warranty or assumes any legal liability for the accuracy, completeness, or for the use or results of such use of any information, product, or process disclosed; or 2. representation that such use or results of such use would not infringe privately owned rights; or 3. endorsement or recommendation of any specifically identified commercial product, process, or service. Any views and opinions of authors expressed in this work do not necessarily state or reflect those of the United States Government, or its contractors, or subcontractors. Printed in the United States of America Prepared for U.S. Department of Energy ii Keywords: Tank 48H, Characterization, Phase 1 Testing Retention: Permanent Tank 48H Phase 1 Initial Testing Using Sodium Permanganate to Decompose Tetraphenylborate: As- Received Characterization of HTF-48-25-17 E. J. Craig September 2025 Savannah River National Laboratory is operated by Battelle Savannah River Alliance for the U.S. Department of Energy under Contract No. 89303321CEM000080. iii REVIEWS AND APPROVALS AUTHORS: ELIZABETH CRAIG (Affiliate) Digitally signed by ELIZABETH CRAIG (Affiliate) Date: 2025.09.17 13:43:45 -04'00' E. J. Craig, Chemical Flowsheet Development Date TECHNICAL REVIEW: Digitally signed by THOMAS PETERS (Affiliate) THOMAS PETERS (Affiliate) Date: 2025.09.17 15:40:26 -04'00' T. B. Peters, Separation Science and Engineering, Reviewed per E7 2.60 Date APPROVAL: Digitally signed by CHRISTOPHER BANNOCHIE (Affiliate) Date: 2025.09.17 16:45:17 -04'00' C. J. Bannochie, Nuclear and Chemical Processing, Technical Program Manager Date Digitally signed by BRANDI CLARK (Affiliate) BRANDI CLARK (Affiliate) Date: 2025.09.17 17:41:02 -04'00' B. N. Clark, Nuclear and Chemical Processing, Manager Date Digitally signed by FRANK PENNEBAKER (Affiliate) FRANK PENNEBAKER (Affiliate) Date: 2025.09.17 22:29:10 -04'00' F. M. Pennebaker, Environmental and Legacy Management, Director Date Digitally signed by Kirk Russell Kirk Russell Date: 2025.10.01 13:07:34 -04'00' K. J. Russell, Flowsheet Development & Facility Integration Date iv PREFACE OR ACKNOWLEDGEMENTS The author would like to express their appreciation to Charles Nash, Tom Peters, Matthew Siegfried, Terri Fellinger, Bill Holtzscheiter, and Kenneth Fernandez for their interest in this effort and sharing their knowledge on the topic of Tank 48H remediation. The author also acknowledges assistance in the completion of sample transfer and handling tasks by the Shielded Cells Operations group particularly Kawanna Williams, Jennifer Clark, Kevin Haupfear, and Vic Skeens, and the completion of sample analyses tasks by David DiPrete, the Nuclear Measurements group, and the Analytical and Tank Farm Characterization group. v EXECUTIVE SUMMARY This report provides results from a detailed characterization study of Tank 48H sample HTF-48-25-17 performed by the Savannah River National Laboraotry (SRNL). The slurry sample was retrieved from Savannah River Site (SRS) Tank 48H on February 25, 2025 and received at the SRNL shielded cells on 02/25/2026. This effort completes the first task of a multi-phase approach, requested by Savannah River Mission Completion (SRMC), to study tetraphenylborate (TPB) decomposition in Tank 48H using sodium permanganate with radioactive waste. A summary of key results from HTF-48-25-17 include: x The average densities of the HTF-48-25-17 for slurry was 1.28 g/mL and for filtrate was 1.27 g/mL. x The average weight percent total dried solids was 27.4 %, for dissolved solids was 26.1 %, and for insoluble solids was 1.77%. x Cs-137 was analyzed in both the supernate and slurry. The result for Cs-137 in supernate was 2.13E+07 dpm/mL and the result for Cs-137 in slurry was 5.34E+08 dpm/g. x High-Performance Liquid Chromatography (HPLC) was used to measure tetraphenylborate (TPB) and degradation products in the supernate and slurry. Phenol, TPB, and biphenyl were detected in the slurry. TPB was detected at 1.82E+04 mg/L in the slurry. Phenol was the only degradation product detected in the supernate. Volatile Organic Analysis (VOA) was used to measure volatile organic species. Benzene was detected and reported at 104 mg/L. A comparison of results from the physical, chemical, and radionuclide characterizations in this report with results from previous samples is also provided. vi TABLE OF CONTENTS LIST OF TABLES ..................................................................................................................................... viii LIST OF FIGURES ................................................................................................................................... viii LIST OF ABBREVIATIONS ...................................................................................................................... ix 1.0 Introduction ............................................................................................................................................. 1 2.0 Experimental Procedure .......................................................................................................................... 1 2.1 Sample Information ............................................................................................................................. 1 2.2 Sample Analysis .................................................................................................................................. 2 2.2.1 Densities and Weight Percent Solids ............................................................................................ 3 2.2.2 Aqueous Supernate Dilutions ....................................................................................................... 3 2.2.3 Water Diluted Slurry..................................................................................................................... 4 2.2.4 Mercury Dilution .......................................................................................................................... 4 2.2.5 Digestions ..................................................................................................................................... 4 2.2.6 Am/Cm Preparation ...................................................................................................................... 5 2.3 Quality Assurance ............................................................................................................................... 5 3.0 Results and Discussion ........................................................................................................................... 5 3.1 Sample Transfer .................................................................................................................................. 5 3.2 Density and Weight Percent Solids ..................................................................................................... 6 3.3 Supernate Analytical Results............................................................................................................... 7 3.4 Slurry Analytical Results................................................................................................................... 10 3.5 Comparison Data ............................................................................................................................... 13 4.0 Conclusions and Recommendations ..................................................................................................... 15 5.0 Reference .............................................................................................................................................. 16 Appendix A . Mass Spectrometry results for supernate and slurry............................................................. 18 vii LIST OF TABLES Table 2-1. Sample Preparations Performed for Each Analysis .................................................................... 3 Table 3-1. Densities and Weight Percent Solids .......................................................................................... 6 Table 3-2. Mercury Results in Supernate..................................................................................................... 7 Table 3-3. Supernate Anions........................................................................................................................ 7 Table 3-4. Chemical Concentrations for Semi-Volatile Organic Compounds and Volatile Organic Compounds in Supernate ....................................................................................................................... 8 Table 3-5. HPLC Measurements of Tetraphenylborate and Degradation Products in Supernate ................ 8 Table 3-6. Elemental Composition of Supernate ......................................................................................... 9 Table 3-7. Radionuclides in Supernate ...................................................................................................... 10 Table 3-8. Slurry Anions............................................................................................................................ 10 Table 3-9. Chemical Concentrations in Slurry for Semi-Volatile Organic Compounds and Volatile Organic Compounds .......................................................................................................................................... 11 Table 3-10. HPLC Measurements of Tetraphenylborate and Degradation Products in Slurry.................. 11 Table 3-11. Elemental Composition of Slurry ........................................................................................... 12 Table 3-12. Radionuclides in Slurry .......................................................................................................... 13 Table 3-13 Comparison Data of Tank 48H Supernate Results ................................................................... 14 Table 3-14 Comparison Data of Tank 48H Slurry Results ......................................................................... 15 LIST OF FIGURES Figure 2-1 Photographs of (a) sample HTF-48-25-17 being retrieved from Tank 48H Riser B2, (b) the 3L sampler in the SRNL shielded cells, and (c) the 4L HDPE bottle with Tank 48H slurry. .................... 2 Figure 3-1 Photographs of HTF-48-25-17 (a) being ladled out of the metal sampler, (b) being scooped out of the metal sampler with a metal spoon and (c) a portion of the “soft crystal” solids in weigh boat being transferred into a HDPE bottle..................................................................................................... 6 viii LIST OF ABBREVIATIONS ATFC Analytical and Tank Farm Characterization AR Aqua Regia DMA Direct Mercury Analysis DOE Department of Energy DWPF Defense Waste Processing Facility HCl Hydrochloric Acid HDPE High Density Polyethylene HPLC High-Performance Liquid Chromatography IC Ion Chromatography ICP-ES Inductively-Coupled Plasma-Emission Spectroscopy ICP-MS Inductively-Coupled Plasma-Mass Spectroscopy ITP In Tank Precipitation MST Monosodium Titanate NaTPB Sodium Tetraphenylborate NM Nuclear Measurements PHA Pulse Height Analysis PF Peroxide Fusion SRMC Savannah River Mission Completion SRNL Savannah River National Laboratory SRS Savannah River Site SS Stainless Steel SVOA Semivolatile Organic Analysis TIC Total Inorganic Carbon TOC Total Organic Carbon TPB Tetraphenylborate TTQAP Task Technical Quality Assurance Plan TTR Task Technical Report VOA Volatile Organic Analysis wt% Weight Percent ix 1.0 Introduction Tank 48H at the Savannah River Site (SRS) currently holds approximately 270,000 gallons of legacy material comprised of decontaminated salt solution, approximately 20,000 kilograms of tetraphenylborate (TPB) solids, 3,400 kilograms of sludge solids, and 1,800 kilograms of monosodium titanate (MST). Tank 48H was the main reaction tank for the In-Tank Precipitation (ITP) process where sodium tetraphenylborate (NaTPB) was added to precipitate cesium and potassium as TPB salts. In addition to NaTPB, MST was added to bind strontium and actinides from the salt solution. The original plan called for processing the TPB slurry in the ITP Facility, the Late Waste Facility, and the Defense Waste Processing Facility (DWPF). That process included concentrating the TPB, washing the non-radioactive salts to reduce the nitrite concentration, decomposing the TPB to benzene, and separating the benzene from the aqueous waste.1 The unexpected decomposition of the TPB in Tank 48 caused excessive benzene to be released that exceeded flammability limits established for the tank. Any future processing by ITP was ceased by the Department of Energy (DOE) in 1998.2 Recently, the Savannah River National Laboratory (SRNL) performed scoping tests using sodium permanganate to oxidize and decompose the TPB at room temperature and 40 °C.3 In addition, tests at 40°C were performed at pH 6, 10, and 11 and showed a destruction of TPB of >90% is possible after a reaction time of two weeks.4 Characterization for physical and chemical composition and radionuclides in support of the disposition of Tank 48H material was last conducted in 2022.1 Savannah River Mission Completion (SRMC) has issued a Technical Task Request (TTR) which outlines the first of three phases for research and development activities to study TPB decomposition using sodium permanganate.5 SRNL issued a Task Technical and Quality Assurance Plan (TTQAP) in response.6 The initial phase is dedicated to a detailed characterization of Tank 48H slurry and the identification of key flowsheet parameters via testing using radioactive and simulated slurries. This report covers the detailed characterization of Tank 48H slurry. 2.0 Experimental Procedure 2.1 Sample Information On February 25, 2025, SRMC retrieved sample HTF-48-25-17 from Tank 48H Riser B2 after a 24 hour, four-pump mixing campaign. The sample was acquired from Tank 48H using a 3L stainless steel (SS) sampler as soon as possible after pump shutdown. At the time of retrieval, the tank liquid level was 74.4 inches and the supernate temperature was 23 °C. Photographs of HTF-48-25-17 being retrieved at Tank 48H and the as-received in the SRNL Shielded Cells are provided in Figure 2-1. 1 Figure 2-1 Photographs of (a) sample HTF-48-25-17 being retrieved from Tank 48H Riser B2, (b) the 3L sampler in the SRNL shielded cells, and (c) the 4L HDPE bottle with Tank 48H slurry. The slurry sample was transferred from the 3L SS sampler into a 4L High Density Polyethylene (HDPE) bottle in the SRNL shielded cells (Figure 2-1). After the bulk of the slurry was transferred, the 3L metal sampler was rinsed with the slurry’s supernate to ensure all solids were transferred into the HDPE bottle. Key observations from transferring the slurry from the metal sampler to the HDPE bottle are provided in Section 3.1. HTF-48-25-17 was mixed with an overhead mixer for 40 minutes prior to retrieving a 400 mL subsample (Figure 3-1). This 400 mL subsample was then used to complete the characterization analyses provided in this report. 2.2 Sample Analysis Table 2-1 shows the preparation methods utilized for each analysis performed by the Analytical and Tank Farm Characterization (ATFC) and the Nuclear Measurements (NM) groups at SRNL. Weight % solids (wt%), and density measurements were performed in the Shielded Cells. 2 Table 2-1. Sample Preparations Performed for Each Analysis Preparation Slurry/Filtrate Analysis ICP-ES, ICP-MS, TIC/TOC, IC ANIONS, VOA, SVOA, TBASE/OH/OTHER BASE, Aqueous Supernate Dilution Filtrate GAMMA SCAN, GAMMA SCAN NO CS, SR-90, U_233_234_235_236, TC-99, GROSS ALPHA Water Diluted Slurry Filtered Slurry IC ANIONS Water Diluted Slurry Not TBASE/OH/OTHER BASE, VOA, Slurry Filtered TIC/TOC ICP-ES, ICP-MS, Aqua Regia (AR) Slurry AA_DMA_TOTAL MERCURY, TC-99 ICP-ES, ICP-MS, PU_242_244, PU_238_241, GAMMA SCAN, Peroxide Fusion (PF) Slurry GAMMA SCAN NO CS, SR-90, U_233_234_235_236, GROSS ALPHA Methylene Chloride Extraction Slurry SVOA AA_DMA_TOTAL_MERCURY, INORGANIC_MERCURY, PURGEABLE_MERCURY, VOA Mercury Dilution Filtrate (Dimethyl Mercury), ETHYL_MERCURY, METHYL_MERCURY Americium and Curium Slurry AM_CM 2.2.1 Densities and Weight Percent Solids Slurry densities and supernate densities were obtained in duplicate using 10 mL volumetric flasks and an analytical balance. The supernate was obtained by filtering a portion of the slurry through a 0.45 µm nylon filter. Filtrate, instead of supernate, was used to ensure no insoluble solids would be accounted for in the supernate density measurements. Weight percent total and dissolved solids measurements were performed in quadruplicate. Aliquots of slurry and filtrate were dried to a constant weight at 115 °C.7 Filtrate was obtained by filtering a portion of the slurry through a 0.45 μm nylon filter. Filtrate, instead of supernate, was used in weight percent solids to ensure no insoluble solids would be accounted for in the dissolved solids measurements. Weight percent insoluble and soluble solids were calculated from the total and dissolved solids measurement. 2.2.2 Aqueous Supernate Dilutions Aqueous supernate dilutions were submitted to SRNL-ATFC for total inorganic carbon/total organic carbon (TIC/TOC), Total Base/OH/Other Base excluding CO32-, ion chromatography (IC) anions, inductively coupled plasma - emission spectroscopy (ICP-ES), inductively coupled plasma - mass spectrometry (ICP-MS), gamma scan, Cs-removed gamma scan, volatile organic analysis (VOA), semi- volatile organic analysis (SVOA) and alpha counting. Isotopes of uranium were determined from purified aliquots analyzed by ICP-MS through the U233/U234/U235/U236 method. Aliquots of the dissolution were purified with diamyl amylphosphonate based solid phase extraction.8 The supernate 3 was obtained by filtering a portion of the slurry through a 0.45 m nylon filter. Filtrate, instead of supernate, was used for the supernate analytical results to ensure no insoluble solids would be accounted for in the measurements. One set of filtrate aliquots were diluted in duplicate by ~10x with water. The purpose of dilution was to reduce personnel radiation exposure. 2.2.3 Water Diluted Slurry Filtered, water diluted slurry was prepared to obtain IC anions in slurry. This was performed by weighing out a set amount of slurry, diluting the sample with water by ~10x to dissolve water soluble solids, and filtering the sample with a 0.45 μm Nylon syringe filter to prevent solids from being sent to the IC instrument. Unfiltered, water diluted slurry was prepared to obtain free hydroxide, TIC/TOC and VOA. This was performed by weighing out a set amount of slurry and diluting the sample with water by ~10X to dissolve water soluble solids. 2.2.4 Mercury Dilution Mercury dilutions were performed to obtain the analyses for methyl- and ethyl- mercury, inorganic mercury, purgeable mercury (i.e. elemental mercury plus dimethylmercury), and elemental mercury. Inorganic mercury, purgeable mercury and elemental mercury were diluted ~100x with purified water using a thick-walled glass volumetric flask with a Teflon stopper. The sample was then transferred to a 15 mL glass vial with little to no head space. Methyl- and ethyl- mercury were diluted ~100x with purified water and high purity hydrochloric acid (HCl) (0.4% concentration) using a thick-walled glass volumetric flask with a Teflon stopper. The sample was then transferred to a 15 mL glass vial with little to no head space. These samples then exited the shielded cells and were refrigerated.9 2.2.5 Digestions Slurry samples were digested by two methods, AR and PF, for analysis of the slurry solids. For the AR digestions, aliquots of slurry were mixed with aqua regia and heated for two hours in sealed Teflon pressure vessel in an oven at 115 °C. The resulting liquids were diluted to 100 mL and submitted to SRNL-ATFC for ICP-ES, ICP-MS, and DMA analyses. For the PF digestions, aliquots of slurry were dried and fused at 675 °C with sodium peroxide and sodium hydroxide. The fused samples were then dissolved with nitric acid. The resulting liquids were diluted to 100 mL with water and analyzed for ICP-ES and alpha counting. Each digestion was performed in duplicate. See Procedure L16.1-ADS- 2226 for aqua regia and L16.1-ADS-2502 for peroxide fusion in the SRNL-ATFC procedure manual for detail of the digestion techniques.10,11 For the elements quantified by ICP-ES, results from two digestions were compared. In general, if the percent difference between the two results was 10% or less, the average is reported. If the percent difference between results was greater than 10%, one digestion was chosen. Those decisions are noted in the results section. For the elements Ag, Be, Cd, Ce, Co, Cu, Li, Mo, P, S, Sb, Si, Sn, Ti, V, and Zn; ICP-ES results from AR digested samples are reported since these elements were not detected in the PF digested sample (AR digested samples typically have lower detection limits due to less dilution required at the instrument). For the elements not detected in either the PF or AR digestions, the lowest detection limit was reported. For K and Na, results from the ICP-ES of the AR digestions were used because these elements were detected in significant quantities in the PF reagent blank. The PF digestion method utilizes sodium peroxide, which, in addition to Na, likely contains K. The PF digestion method is performed in Zr crucibles, which contributes additional Zr to the analysis. For total Hg, results from the DMA analysis of the AR digestion were used. For Th, ICP-MS (mass 232) from the AR digestion was reported due to the lower detection limit instead of ICP-ES. For Al, and Ca, ICP-ES from the PF digestions were used because AR does not fully dissolve these elements. 4 Fission product elements Ru, Rh, and Pd were quantified by ICP-MS from the AR digestion using a methodology described by Bibler.12 In summary, Ru is reported from the sum of masses 101, 102, and 104. Rh is taken from mass 103. Pd is determined from mass 105 and a factor derived from fission yields of other Pd isotopes. Nd is also determined from ICP-MS from the AR digestion. Stable isotopes of Nd include masses 142 to 146, 148, and 150.13 However, there is a stable isotope of Ce at mass 142. Therefore, mass 142 is not used in the Nd quantification, which may lead to small under-reporting of Nd. Isotopes of uranium in the slurry were determined from U233/U234/U235/U236 through ICP-MS on PF digested samples. Isotopes of plutonium were determined by PuTTA separation, alpha counting and ICP-MS of PF digested samples. Cs-removed gamma scan method was used to determine Co-60, Ru-106, Sb-125, Ce-144, Eu-154, and Am-241 with a high purity coaxial germanium detector. Cs-137 was removed from the duplicate PF samples by using an ammonium phosphomolybdate resin. This allowed the remaining gamma photons at lower concentrations to be detected with lower detection limits. Cs-137 was determined through gamma pulse height analysis (PHA) on duplicate PF samples. 2.2.6 Am/Cm Preparation This method was used to obtain Am-241, Am-242m, Am-243, Cm-242, Cm-243, Cm-244, Cm-245, Cm-247, Cf-249, and Cf-251. Peroxide fusion was performed on the slurry. The analytes were then extracted from the dissolution filtrate using a commercially available ion exchange resin (Eichrom® DGA). Samples were held in the Shielded Cells for 9 days to allow for the Y-90 to decay before submitting to NM. These samples were then purified further with a second RE resin extraction followed by an Eichrom® Ln resin extraction. These analytes were then analyzed by alpha and low-energy gamma counting techniques and by ICP-MS.8 2.3 Quality Assurance This work was requested via a TTR and directed by a TTQAP.5,6 Requirements for performing reviews of technical reports and the extent of review are established in manual E7 2.60. SRNL documents the extent and type of review using the SRNL Technical Report Design Checklist contained in WSRC-IM- 2002-00011, Rev. 2.14 The functional classification requested for this work is Safety Class. In accordance with Manual E7, Procedure 3.60, a technical review of the contents of this report has been performed to ensure consistency and accuracy. Per Manual E7, Procedure 2.60, a Design Verification, at a minimum, must be performed for work supporting a Safety Class functional classification. 3.0 Results and Discussion 3.1 Sample Transfer Multiple strategies were employed to transfer material from the SS sampler to the 4L HDPE bottle. Initial efforts to transfer slurry utilized a peristaltic pump, but a large amount (approximately 600 mL) of slurry remained in the SS sampler even after rinsing with supernate. The peristaltic pump was ultimately abandoned after several attempts with different pump heads, tubes and dip legs (max diameter 0.31 inches). A ladle and metal spatula were used to transfer the remaining material into the 4L HDPE bottle. Photographs of the transfer process are shown in Figure 3-1. A portion of the “soft crystal” solids can be seen in the right photo in a weigh boat being added to the HDPE bottle. 5 Figure 3-1 Photographs of HTF-48-25-17 (a) being ladled out of the metal sampler, (b) being scooped out of the metal sampler with a metal spoon and (c) a portion of the “soft crystal” solids in weigh boat being transferred into a HDPE bottle. 3.2 Density and Weight Percent Solids Presented in Table 3-1 are the results for density and weight percent solids of the Tank 48H Subsample. Table 3-1. Densities and Weight Percent Solids Method Average RSD, n* Slurry Density (g/mL) 1.28 0.43, 3 Filtrate Density (g/mL) 1.27 0.50, 3 Wt% Total Dried Solids 27.4 1.94, 3 (Slurry Basis) Wt% Dissolved Solids 26.1 0.32, 3 (Supernate Basis) Wt% Insoluble Solids 1.77 1.81 (Slurry Basis) Wt% Soluble Solids 25.6 NA (Slurry Basis) *RSD=relative standard deviation with number of measurements (n). NA=not applicable because result is calculated. Error propagation of the total solids (slurry basis) and soluble solids (filtrate basis) yielded a 95% confidence interval for the insoluble solids of approximately ±0.3 weight % for both sets performed. The confidence interval is derived using the inverse Student’s t-distribution which requires probability and degrees of freedom, partial derivative of the weight percent of insoluble solids with respect to total solids, partial derivative of the weight percent of insoluble solids with respect to soluble solids, standard error of the weight percent total solids, and standard error of the weight percent soluble solids. Uncertainty for the insoluble solids does not account for variability in the sampling. Contributing factors to larger 95% confidence interval values include standard deviation of results (incorporated in standard error), number of replicates (incorporated in degrees of freedom), and average weight percent of soluble solids (incorporated in partial derivative of weight percent insoluble solids with respect to total solids and soluble solids). A higher standard deviation of results, larger amount of weight percent soluble solids, and fewer number of replicates can lead to a larger 95% confidence interval value. 6 3.3 Supernate Analytical Results The result for mercury in supernate is provided in Table 3-2, the supernate anions is provided in Table 3-3, the results from SVOA and VOA in supernate are provided in Table 3-4, the results for the HPLC measurements of tetraphenylborate and degradation products are provided in Table 3-5, and the results for the elemental composition and radionuclides in supernate are provided in Table 3-6 and Table 3-7. Table 3-2. Mercury Results in Supernate Analyte Units Result %RSD Uncertainty (%) Elemental Mercury mg/L <1.12E+02 NA NA Inorganic Mercury mg/L <1.12E+01 NA NA Purgeable Mercury mg/L <1.12E+01 NA NA Ethyl Mercury mg/L <1.18E+02 NA NA Methyl Mercury mg/L <1.18E+01 NA NA Table 3-3. Supernate Anions Analytical Analyte Units Results %RSD Uncertainty Method (%) Bromide IC mg/L <6.65E+02 NA NA Chloride IC mg/L 7.36E+02 1.19 10 Fluoride IC mg/L <1.33E+02 NA NA Formate IC mg/L 2.71E+02 1.83 10 Nitrate IC mg/L 1.07E+04 0.72 10 Nitrite IC mg/L 2.95E+04 1.00 10 Oxalate IC mg/L 9.48E+02 2.77 10 Phosphate IC mg/L 3.96E+02 0.83 10 Sulfate IC mg/L 2.21E+02 0.68 10 Carbonate TIC mg/L 1.07E+05 0.59 7 Free OH Titration M 1.48E+00 7.65 10 Total Organic TOC mg Carbon/L 2.26E+03 2.72 7 Carbon < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable Table 3-4 indicated that only VOA analyte detected was toluene, 7.75E+00 mg/L. All other VOA analytes in the supernate were below the detection limit of <13 mg/L and all SVOA analytes in the supernate were below the detection limit of <2.6 mg/L. Table 3-5 indicates only phenol was detected in the supernate. Biphenyl, 2PB, 3PB, and TPB were lower than the detection limits in the HPLC method. 7 Table 3-4. Chemical Concentrations for Semi-Volatile Organic Compounds and Volatile Organic Compounds in Supernate Analytical Analyte Units Results %RSD Uncertainty Method (%) Toluene VOA mg/L 7.75E+00 5.45 10 Table 3-5. HPLC Measurements of Tetraphenylborate and Degradation Products in Supernate Results Analyte %RSD Uncertainty (mg/L) (%) Phenol 5.61E+02 0.31 10 2PB <101 NA NA 3PB <101 NA NA TPB <101 NA NA Biphenyl <101 NA NA NA = Not Applicable. 8 Table 3-6. Elemental Composition of Supernate Analytical One Sigma Uncertainty Element Results (mg/L) % RSD Method (%) Ag ES <9.31E-02 NA NA Al ES 2.91E+03 1.94 5.14 B ES 5.92E+02 1.27 5.00 Ba ES <7.98E-02 NA NA Be ES <3.99E-02 NA NA Ca ES <2.17E+00 NA NA Cd ES <6.65E-02 NA NA Ce ES <9.31E-01 NA NA Co ES <2.26E-01 NA NA Cr ES 4.91E+01 1.15 5.00 Cu ES <1.04E+00 NA NA Fe ES <1.65E+00 NA NA Gd MS <1.32E-02 NA NA Hg DMA <1.12E+02 NA NA K ES 5.34E+02 3.35 5.09 La ES <9.31E-02 NA NA Li ES <1.64E+00 NA NA Mg ES <1.06E-01 NA NA Mn ES <6.12E-01 NA NA Mo ES 6.82E+00 1.38 5.01 Na ES 1.38E+05 0.68 5.03 Nd MS <7.95E-02 NA NA Ni ES <3.06E-01 NA NA P ES 2.24E+02 1.26 5.00 Pd MS <1.10E-01 NA NA Rh MS 1.27E-01 0.00 10.0 Ru MS 2.89E-01 2.75 10.0 S ES 2.96E+02 1.59 5.02 Sb ES <9.31E-01 NA NA Si ES <1.23E+01 NA NA Sn ES <3.99E+00 NA NA Sr ES <3.99E-02 NA NA Th ES <1.26E+00 NA NA Ti ES <4.39E-01 NA NA V ES <9.31E-01 NA NA Zn ES 1.52E+01 1.24 5.01 Zr ES <9.31E-02 NA NA < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable 9 Table 3-7. Radionuclides in Supernate Analytical One Sigma Analyte Results (dpm/mL) %RSD Method Uncertainty (%) Cs-133 MS 4.30E-01 (mg/L)* 2.45 10.0 Cs-137 Gamma Scan 2.13E+07 0.29 5.00 Ba-137m Calculated from Cs-137 2.02E+07 NA NA Co-60 Gamma Scan Cs removed <3.44E+02 NA NA Ru-106 Gamma Scan Cs removed <2.08E+03 NA NA Sb-125 Gamma Scan Cs removed <1.15E+03 NA NA Sb-126 Gamma Scan Cs removed 4.77E+02 5.31 13.9 Sn-126 Gamma Scan Cs removed 4.77E+02 5.31 13.9 Ce-144 Gamma Scan Cs removed <2.37E+03 NA NA Eu-154 Gamma Scan Cs removed <7.33E+02 NA NA Am-241 Gamma Scan Cs removed <1.49E+03 NA NA Sr-90 Sr_90 <5.33E+04 NA MDA Y-90 Secular Equilibrium <5.33E+04 NA NA Tc-99 Tc_99 5.11E+04 7.84 7.97 U-233 U_233_234_235_236 4.32E+02 0.92 17.3 U-234 U_233_234_235_236 1.58E+03 1.18 17.3 U-235 U_233_234_235_236 1.14E+00 0.56 17.3 U-236 U_233_234_235_236 7.23E+00 0.96 17.3 U-238 U_233_234_235_236 1.23E+00 1.62 10.0 Total Alpha Liquid Scintillation <6.33E+04 NA NA *dpm/mL does not apply as Cs-133 is stable. < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable. MDA = Minimum Detectable Activity 3.4 Slurry Analytical Results The results for the slurry anions are provided in Table 3-8, chemical concentrations for SVOA and VOA compounds in slurry are provided in Table 3-9, HPLC measurements of tetraphenylborate and degradation products are provided in Table 3-10, and elemental composition and radionuclides in slurry are provided in Table 3-11 and Table 3-12. Table 3-8. Slurry Anions Analytical Analyte Units Results %RSD Uncertainty Method (%) Bromide IC mg/L <6.37E+02 NA NA Chloride IC mg/L 6.67E+02 1.37 10 Fluoride IC mg/L <1.27E+02 NA NA Formate IC mg/L 2.53E+02 0.00 10 Nitrate IC mg/L 9.78E+03 1.59 10 Nitrite IC mg/L 2.79E+04 0.76 10 Oxalate IC mg/L 1.59E+03 3.11 10 Phosphate IC mg/L 4.23E+02 14.4 10 Sulfate IC mg/L 1.85E+02 NA* 10 Carbonate TIC mg/L 8.56E+04 0.03 7 Free OH Titration M 1.65E+00 2.16 10 Total Organic Carbon TOC mg Carbon/L 1.09E+04 68.3 7 < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable *Reported as a single result as the duplicate sample was below detection limit. 10 Table 3-9 indicates that toluene and benzene were detected with VOA. Benzene was double the ~50 mg/L value reported in the 2012 characterization report.15 All other VOA analytes in the slurry were below detection limit of <1 mg/L. Table 3-10 indicates that phenol and TPB were detected with HPLC. 2PB and 3PB were lower than the detection limit in the HPLC method. Biphenyl was measured using both SVOA and HPLC, but concentrations were outside the desired working range of the SVOA method. The HPLC method is designed for the relatively high concentrations of biphenyl and is considered to provide a more precise measurement. Table 3-9. Chemical Concentrations in Slurry for Semi-Volatile Organic Compounds and Volatile Organic Compounds Analytical Analyte Results (mg/L) %RSD Uncertainty Method (%) Toluene VOA 1.27E+01 2.16 10 Benzene VOA 1.04E+02 15.7 10 Biphenyl SVOA 4.85E+02 20.4 10 All other VOA analytes in the were <1 mg/L. All SVOA analytes in the supernate were <0.2 mg/L. Table 3-10. HPLC Measurements of Tetraphenylborate and Degradation Products in Slurry Results Analyte %RSD Uncertainty (mg/L) (%) Phenol 7.62E+02 7.02 10 TPB 1.82E+04 1.97 10 2PB <102 NA NA 3PB <102 NA NA Biphenyl 1.04E+03 18.7 10 NA = Not Applicable. 11 Table 3-11. Elemental Composition of Slurry Analytical One Sigma Element Results (mg/L) % RSD Method Uncertainty (%) Ag AR, ES <3.75E-01 NA NA Al PF, ES 3.10E+03 1.94 5.00 B AR/PF, ES 1.21E+03 1.27 5.00 Ba AR, ES 5.95E+00 2.74 5.00 Be AR, ES <1.61E-01 NA NA Ca PF, ES 5.21E+02 14.0 5.01 Cd AR, ES <3.20E-01 NA NA Ce AR, ES <2.15E+00 NA NA Co AR, ES <4.86E-01 NA NA Cr AR, ES 6.25E+01 3.15 5.00 Cu AR, ES <1.43E+01 NA NA Fe AR, ES 1.08E+02 4.38 5.04 Gd AR, ES <5.31E-01 NA NA Hg DMA 2.61E+01 1.39 10.0 K AR, ES 2.76E+03 3.35 5.03 La AR, ES <2.09E-01 NA NA Li AR, ES <3.81E+00 NA NA Mg AR, ES 2.67E+01 6.09 5.03 Mn AR, ES 1.03E+01 2.82 5.02 Mo AR, ES 7.15E+00 3.08 5.06 Na AR, ES 1.38E+05 0.84 5.02 Nd AR, MS <3.68E-01 NA NA Ni AR, ES <4.85E+00 NA NA P AR, ES 2.23E+02 2.08 5.01 Pd AR, MS <5.09E-01 NA NA Rh AR, MS 1.66E-01 1.09 10.0 Ru AR, MS <5.67E-01* NA NA S AR, ES 3.03E+02 3.05 5.10 Sb AR, ES <2.16E+00 NA NA Si AR, ES 1.41E+02 4.09 5.04 Sn AR, ES <9.32E+00 NA NA Sr AR, ES <1.06E+00 NA NA Th AR, MS <3.10E-01 NA NA Ti AR/PF, ES 9.55E+02 2.75 NA V AR, ES <2.18E+00 NA NA Zn AR/PF, ES 1.70E+01 1.24 5.00 Zr AR, ES <1.08E+00 NA NA < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable * Mass 104 was below detection limit when Ru was calculated. Therefore, the Average result is <. 12 Table 3-12. Radionuclides in Slurry Analyte Analytical One Sigma Results (dpm/g) %RSD Method Uncertainty (%) Cs-133 MS 1.44E+01 (mg/L)* 1.89 10.0 Cs-135 Calculated from MS16 2.75E+04 NA NA Cs-137 Gamma Scan 5.34E+08 2.48 5.00 Ba-137m Calculated from Cs-137 5.05E+08 NA NA Co-60 Gamma Scan Cs Removed <1.67E+03 NA NA Ru-106 Gamma Scan Cs Removed <9.20E+03 NA NA Sb-125 Gamma Scan Cs Removed <5.37E+03 NA NA Ce-144 Gamma Scan Cs Removed <1.12E+04 NA NA Eu-154 Gamma Scan Cs Removed <3.47E+03 NA NA Am-241 Am/Cm <1.13E+02 NA NA Am-242m Am/Cm <3.54E+00 NA NA Am-243 Am/Cm <5.34E-01 NA NA Cm-242 Am/Cm <2.93E+00 NA NA Cm-243 Am/Cm <9.48E-01 NA NA Cm-244 Am/Cm <3.17E+02 NA NA Cm-245 Am/Cm <7.78E-01 NA NA Cm-247 Am/Cm <2.39E-01 NA NA Cf-249 Am/Cm <2.67E-01 NA NA Cf-251 Am/Cm <8.39E-01 NA NA Sr-90 Sr_90 <6.39E+05 NA NA Y-90 Secular Equilibrium <6.39E+05 NA NA Tc-99 Tc_99 4.02E+04 9.50 9.29 U-233 U_233_234_235_236 4.32E+02 0.92 17.3 U-234 U_233_234_235_236 1.58E+03 1.18 17.3 U-235 U_233_234_235_236 1.14E+00 0.56 17.3 U-236 U_233_234_235_236 7.23E+00 0.96 17.3 U-238 U_233_234_235_236 1.23E+00 1.62 10.0 Pu-239 PU_242_244, PU_238_241 <1.54E+03 NA NA Pu-240 PU_242_244, PU_238_241 <1.54E+03 NA NA Pu-242 PU_242_244, PU_238_241 <9.77E+01 NA NA Pu-244 PU_242_244, PU_238_241 <4.54E-01 NA NA Pu-241 PU_242_244, PU_238_241 <1.14E+04 NA NA Pu-238 PU_242_244, PU_238_241 1.90E+05 35.0 5.66 Total Alpha Liquid Scintillation <3.19E+05 NA NA *dpm/g does not apply as Cs-133 is stable. < Results are not the average. They are the lowest detection limit recorded. NA = Not Applicable 3.5 Comparison Data Samples from Tank 48H have been analyzed over many years. Therefore, it would be wise to compare the current results with previous results to ensure data quality. However, several considerations apply. First, due to changes in the tank volume, care must be taken to either volume normalize the results or compare samples that came from comparable tank volumes. In this case, the tank volumes from comparison samples vary <10%, so a high-level comparison is still valid. Second, as water evaporates from the tank, it is replaced with solutions containing NaOH, and NaNO2 for the purposes of corrosion control.17 Over time, the concentrations of nitrite and nitrate will increase. Free hydroxide also increases, but this is somewhat compromised by reaction of free hydroxide with atmospheric CO2 to create carbonate. Finally, due to the chemical changes, salt precipitation and dissolution can be occurring. The effects of this are difficult to predict. Table 3-13 and Table 3-14 show comparison data for Tank 48H supernate and slurry results from various characterization reports, ranging from 2005 to 2022. 13 For the supernate data, the closest data set to this document is from the corrosion control sample from 2025 (HTF-48-25-17). The results (ICP-ES, Free OH, Cs-137, IC-Anions) from this corrosion control sample agree quite well with the current sample. For example, the common filtrate analyses (ICP-ES, Free OH, Cs- 137, IC-Anions) differ by an average of 4%. When looking at the comprehensive 2015 sample, it is observed that the same analyte set also varies 4%, but there is more dispersion in the individual results.18 Notably, the 2014 sample has less sodium, because of fewer corrosion control additions, and more oxalate. Taken altogether, the current filtrate results are consistent with past results. Table 3-13 Comparison Data of Tank 48H Supernate Results Units 200519 201215 201518 20221 202520* 2025 Volume gal 242,000 245,000 255,000 262,000 270,000 270,000 Density g/mL NA 1.20 1.23 1.28 1.26 1.27 Al mg/L 2309 2050 2740 3370 2781 2910 B mg/L 460 463 563 704 NA 592 Cr mg/L NA 42.1 53.8 63.2 NA 49.1 K mg/L 267 286 448 <582 NA 534 Na mg/L 87899 85800 106000 137000 137080 138000 Chloride mg/L 172 187 703 827 703 736 Formate mg/L 502 296 283 NA 257 271 Phosphate mg/L 428 465 594 756 NA 396 Sulfate mg/L 323 209 218 540 161 221 Nitrite mg/L 23750 24500 28500 34029 29210 29500 Nitrate mg/L 14250 11000 11500 13000 10230 10700 Oxalate mg/L 1440 1590 1660 1540 1021 948 Free OH M 1.34 1.02 1.73 1.69 1.72 1.48 Cs-137 dpm/mL 3.00E+07 2.57E+07 2.38E+07 2.42E+07 2.06E+07 2.13E+07 Phenol mg/L 535 NA 275 43.8** NA 561 NA = Not Applicable *Corrosion Control Sample **SVOA instrumentation used instead of HPLC For the slurry data, the results (ICP-ES, Free OH, Cs-137, IC-Anions) are consistent but show more dispersion among individual results. The 2012 sample contains less free hydroxide compared to the 2022 and 2025 results, which can be attributed to the additions of the corrosion control solutions into the tank. Weight percent total solids have increased over the years due to the increase of soluble solids. Phenol results vary in the supernate and the slurry from the 2022 report. The discrepancy could be due to the type of instrumentation used for analyzing the data set and the conditions under which the Tank 48H sample was prepared. Biphenyl is a factor of three lower than the 2022 slurry, but trends with the 2005 and 2012 reported values. 14 Table 3-14 Comparison Data of Tank 48H Slurry Results Units 200519 201215 20221 2025 Volume gal 242,000 245,000 262,000 270,000 Density g/mL 1.17 1.22 1.26 1.28 Al mg/L 2014 3110 3270 3098 B mg/L 867 1070 676 1207 Cr mg/L 70 74 56.1 62.6 K mg/L 5155 3221 <582 2765 Na mg/L NA NA 1.03E+05 1.38E+05 Free OH M NA 0.652 1.56 1.65 Biphenyl mg/L 415 925 3043 1040 Phenol mg/L 771 609 40.8* 762 TPB mg/L 21000 19000 19700 18240 Total Dried Solids % 20.2 23.2 25.8 27.4 Total Insoluble Solids % 3.05 1.47 1.95 1.77 Cs-137 dpm/mL 7.53E+08 7.81E+08 7.04E+08 6.84E+08 Pu-238 dpm/mL NA 3.13E+05 1.54E+05 2.43E+05 NA = Not Applicable *SVOA instrumentation used instead of HPLC 4.0 Conclusions and Recommendations SRNL received approximately 3L of slurry (i.e., HTF-48-25-17) retrieved from Tank 48H on February 25, 2025. This report documents a detailed characterization of this sample and includes: supernate and slurry density, weight percent solids, chemical composition, and radionuclides. A comparison to results from analogous Tank 48H characterization studies performed in 2005, 2012, and 2022 is also provided. A summary of key results from HTF-48-25-17 includes:  The average densities of the HTF-48-25-17 for slurry was 1.28 g/mL and for filtrate was 1.27 g/mL.  The average weight percent solids for total dried solids was 27.4 %, for dissolved solids was 26.1 %, and for insoluble solids was 1.77%.  Cs-137 was analyzed in both the supernate and slurry. The result for Cs-137 in supernate was 2.13E+07 dpm/mL and the result for Cs-137 in slurry was 5.34E+08 dpm/g.  High-Performance Liquid Chromatography (HPLC) was used to measure tetraphenylborate (TPB) and degradation products in the supernate and slurry. Phenol (7.62E+02 mg/L), TPB (1.82E+04 mg/L), and biphenyl (1.04E+03 mg/L) were detected in the slurry. Phenol was the only degradation product detected in the supernate. Volatile Organic Analysis (VOA) was used to measure volatile organic species. Benzene was detected and reported at 104 mg/L. During transfer of the slurry, it was observed that the material could not be transferred out by peristaltic pumping due to a large amount of solids remaining at the bottom of the metal sampler. It is recommended that any future work that involves Tank 48 a peristaltic pump is not used to pump the material. 15 5.0 Reference 1. M.J. Sigfried, C.A. Nash, “Analysis in Support of Disposition of Tank 48 Legacy Material,” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2022-00016, Rev. 1, 2022. 2. R.A. Jacobs, J. R. Fowler, P. L. Rutland, “Summary of the In-Tank Precipitation Chemistry Program (U),” Westinghouse Savannah River Company, Aiken, SC, WSRC-RP-98-00300, Rev.0, 1998. 3. T.B. Peters, M.J. Siegfried, M.S. Williams, D.H. Jones, “Results of the Scoping Tests for Tank 48H Simulant Destruction,” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2019- 00711, Rev.0, 2019. 4. M.J. Siegfried, T.P. Peters, T.L. White, “Tank 48H Tetraphenylborate Mitigation: Simulant Studies using Sodium Permanganate,” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2021- 00304, Rev. 0, 2021. 5. T. Fellinger, “Tank 48 Permanganate Process - Phase 1 Testing Technical Task Request,” Savannah River Mission Completion, Aiken, SC, X-TTR-H-00147, Rev. 0, 2024. 6. K.M. Miles-Scott, J.M. Pareizs, “Task Technical and Quality Assurance Plan for Tank 48 Permanganate Process - Phase 1 Testing,” Savannah River National Laboratory, Aiken, SC, SRNL- RP-2024-01397, Rev. 0, 2024. 7. “Weight Percent Solids Determination Using a Furnace or Oven,” Savannah River National Laboratory, Aiken, SC, Manual L29 Procedure ITS-0078, Rev. 1, 2012. 8. S.C. Hunter, D.P. Diprete, “Determination of Reportable Radionuclides for Defense Waste Processing Facility (DWPF) Sludge Batch 10,” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2024-00240, Rev.0, 2024. 9. D.J. McCabe, C.L. Crawford, C.J. Bannochie, A.J. Boggess, S.G. Bishop, “Best Handling Practices for Elemental Mercury, Organo-Mercury Compounds, and Inorganic Mercury Compounds,” Savannah River National Laboratory, Aiken, SC, SRNL-TR-2019-00243, Rev.1, 2020. 10. “Aqua Regia Dissolution of Sludge for Elemental Analysis,” Savannah River National Laboratory, Aiken, SC, Manual L16.1 Procedure ADS-2226, Rev. 10, 2013. 11. “Alkali Fusion Dissolutions of Sludge and Glass for Elemental and Anion Analysis,” Savannah River National Laboratory, Aiken, SC, Manual L16.1 Procedure ADS-2502, Rev. 7, 2013. 12. N.E. Bibler, “Measuring and Predicting Fission Product Noble Metals in Savannah River Site High Level Waste Sludges,” Savannah River National Laboratory, Aiken, SC, WSRC-TR-2005-00098, Rev. 0, 2005. 13. “Nuclides and Isotopes: Chart of the Nuclides, Seventeeth Edition,” KAPL, Schenectady, NY, 2009. 14. “Savannah River National Laboratory Technical Report Design Check Guildlines,” Savannah River National Laboratory, Aiken, SC, WSRC-IM-2002-00011, 2004. 16 15. C.A. Nash, T. B. Peters, “Analyses of HTF-48-12-20/24 (February, 2012) and Archived HTF-E- 05-021 Tank 48H Slurry Samples,” Savannah River National Laboratory, Aiken, SC, SRNL-STI- 2012-00420, Rev.0, 2012. 16. C.J. Bannochie, D. P. Diprete, “Determination of Reportable Radionuclides for DWPF Sludge Batch 8 (Macrobatche 10),” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2014- 00179, Rev.0, 2014. 17. K. Martin, “CSTF Corrosion Control Program,” Savannah River Mission Completion, Aiken, SC, WSRC-TR-2002-00327, Rev. 11, 2025. 18. T.B. Peters, T. Hang, “Samples Results from Tank 48H Samples HTF-48-14-158, -159, -169, and -170,” Savannah River National Laboratory, Aiken, SC, SRNL-STI-2015-00141, Rev.0, 2015. 19. F.F. Fondeur, D. P. Lambert, S. D. Fink, “Analysis of Tank 48H Sample HTF-E-05-021,” Westinghouse Savannah River Company, Aiken, SC, WSRC-TR-2005-00358, Rev.0, 2005. 20. K.P. Crapse, “Sample Results External Report HTF-48-25-17,” Savannah River national Laboratory, Aiken, SC, 2025. 17 Appendix A. Mass Spectrometry results for supernate and slurry 18 19 20 21 Distribution List: Elizabeth.craig@srnl.doe.gov Matthew.siegfried@srnl.doe.gov Cj.bannochie@srnl.doe.gov Thomas.peters@srnl.doe.gov Charles.nash@srnl.doe.gov John.pareizs@srnl.doe.gov Jacob.southern@srnl.doe.gov Nathan.wilson@srnl.doe.gov Jared.Riffle@srnl.doe.gov Corey.martin@srnl.doe.gov John.dekarske@srnl.doe.gov Julian.cutler@srnl.doe.gov Hope.brown@srnl.doe.gov william.bates@srnl.doe.gov utopia.boynton@srnl.doe.gov tyler.chavous@srnl.doe.gov brandi.clark@srnl.doe.gov alex.cozzi@srnl.doe.gov c.diprete@srnl.doe.gov david.diprete@srnl.doe.gov connie.herman@srnl.doe.gov sarah.hodges@srnl.doe.gov william.jolin@srnl.doe.gov brady.lee@srnl.doe.gov joseph.manna@srnl.doe.gov gregg.morgan@srnl.doe.gov frank.pennebaker@srnl.doe.gov william.ramsey@srnl.doe.gov luther.reid@srnl.doe.gov boyd.wiedenman@srnl.doe.gov mary.whitehead@srnl.doe.gov terri.fellinger@srs.gov bill.holtzscheiter@srs.gov Kenneth.fernandez@srs.gov Quentin.Werdell@srs.gov Kirk.russell@srs.gov Keisha.martin@srs.gov 22