Validating the Angular Sizes of Red Clump Stars with Intensity Interferometry Alex G. Kim, Robin Kaiser Abstract The surface-brightness-color (SBC) relationship for Red Clump stars provides a critical foundation for precision distance ladder measurements, including the 1% distance determination to the Large Magellanic Cloud. Current SBC calibrations rely on angular diameter measurements of nearby Red Clump stars obtained through long-baseline optical interferometry using the Very Large Telescope Interferometer. We explore the application of intensity interferometry to measure limb-darkened angular diameters of Red Clump stars, offering a complementary approach to traditional amplitude interferometry. We describe the framework for extracting angular diameters from squared visibility measurements in intensity interferometry, accounting for limb darkening through the stellar atmosphere models. For the Red Clump star HD 17652, we show that intensity interferometry in the H H band at baselines matching PIONIER ( ∼ \sim 100 m) could achieve < 1 <1 % angular size uncertainties in 2-hour exposures by measuring the primary peak of the visibility function, enabling direct comparison with existing measurements. Critically, observations at shorter wavelengths probe the secondary visibility maximum, providing independent checks of both measurement and systematic errors that are largely insensitive to limb-darkening assumptions. Exploiting the multiplex advantage of simultaneous multi-bandpass observations and the large number of baselines available with telescope arrays such as the Cherenkov Telescope Array Observatory can reduce observing times to practical levels, making intensity interferometry a viable tool for validating the angular sizes for a subset of the Red Clump star calibration sample. I Introduction Red Clump stars represent an evolutionary phase for intermediate-mass stars that have exhausted their core hydrogen and evolved beyond the red giant branch to burn helium stably in their cores as horizontal branch objects. These stars occupy a distinctive region in the Hertzsprung-Russell diagram, forming a prominent clump of stars at effective temperatures around 5,000 K and luminosities of approximately 75 L_{\odot} , located on the cool side of the horizontal branch. This concentration creates the characteristic ”Red Clump” feature that gives these stars their name. Spectroscopically, Red Clump stars are classified as late G-type to early K-type giants, distinguished by their intermediate surface gravity ( \log g\approx 2.5-3.0 ) and relatively high metallicity compared to globular cluster horizontal branch stars. They can be identified through their spectral characteristics, including the strength of pressure-sensitive lines such as Ca I \lambda 6162 Å and Sr II \lambda 4077 Å  which are diagnostic of their giant luminosity class and intermediate surface gravity. Red Clump stars exhibit remarkably uniform intrinsic properties, particularly their surface-brightness-color (SBC) relationship ( 40 ; 34 ) . 34 calibrated the SBC relationship using angular diameters of a set of 48 stars. These stars have parallax distances measured by the Gaia satellite ( 14 ) and are sufficiently nearby to resolve their angular diameters using long-baseline optical interferometry. The S_{V} surface brightness is calibrated through V-K color with a 0.018 mag/arcsec 2 r.m.s. scatter. Given this relationship, the angular size of a star can be deduced from its apparent magnitude and color. For eclipsing binary systems containing Red Clump stars, the physical parameters of the stellar components – including the semimajor axis, fractional radii, and absolute physical radius of each star – can be derived from simultaneous fits to radial velocity curves obtained from high-resolution spectroscopy and photometric light curves ( 18 ) . The physical parameters of 20 detached eclipsing binaries (DEBs) in the Large Magellanic Cloud have been measured using this procedure ( 19 ) . The ratio between the measured physical radius (from eclipse geometry) and the angular radius (derived from the SBC relationship) directly yields a 1% precision distance to the LMC ( 34 ) . The SBC calibration is based on the angular sizes of calibration stars as determined by 17 through measurements of squared visibility using the Very Large Telescope Interferometer (VLTI) ( 20 ) with the four-telescope beam combiner PIONIER ( 28 ) . The angular diameters of these stars span approximately 1–2 mas, with V -band magnitudes ranging from 4–6.5. The observations utilized projected baselines ranging from 45 to 140 m across several spectral channels in the H band (1.65 \mu m). Limb-darkened angular diameters were derived by fitting theoretical radial intensity profiles I(\theta) from SATLAS stellar atmosphere models ( 32 ) to the observed squared visibility data 1 1 1 The model was downloaded using the Jean-Marie Mariotti Center (JMMC) — MOIO AMHRA service at https://amhra.jmmc.fr/ . . As an example, the intensity profile and associated squared visibility |V|^{2} for the calculated grid point closest to the Red Clump calibrator HD 360, T=4800 and \log{g}=2.5 , are shown in Figure 1 . Figure 1: Left: Normalized B and H -band intensity profiles I(\theta)/I(0) computed by SATLAS and PHOENIX for T=4800 K and \log{g}=2.5 , which is the closest match to the Red Clump star HD 360. Right top: Squared visibility |V|^{2} corresponding to the intensity profiles. Right bottom: Difference between the PHOENIX and SATLAS squared visibilities. The interferometric measurements of HD 360 by 17 lie within u<0.5 . To resolve a 1 mas source at optical to near-infrared wavelengths requires a long interferometric baseline (or an unfeasibly large telescope). The Rayleigh resolution criterion is defined as the angular separation corresponding to the first zero of the diffraction pattern for a uniform disk source \theta=1.22\frac{\lambda}{D}, (1) where \lambda is the wavelength and D is the baseline. PIONIER with H -band central wavelength 1.65 \mu m, and a baseline of D=140 m, can resolve \theta=2.97 mas, several times larger than the angular diameters of the SBC calibrator stars. Although marginally resolved according to the Rayleigh criterion, the stars’ angular sizes can be precisely determined by fitting the shape of the theoretical intensity profiles predicted by the stellar atmosphere. As seen in Figure 3 of 17 the interferometric measurements of |V|^{2} of HD 360 lie in the central peak of the visibility function (within a spacial frequency of u<0.5 in Figure 1 ). Nevertheless, the six baselines spanning 45-140 m obtained from the PIONIER telescope configurations are sensitive to the size-dependent shape of the square-visibility function. Angular diameter measurements depend on the assumed model of the stellar intensity profile. SATLAS modifies the plane-parallel stellar atmosphere code ATLAS to treat spherically extended geometry. ATLAS calculates line blanketing using opacity distribution functions, which average the contributions from different atomic and molecular species. 17 estimate the model error contribution to angular size measurements by comparing intensity profiles at adjacent grid points in temperature, surface gravity, and stellar mass. PHOENIX is an alternative stellar atmosphere code that is inherently spherically symmetric and calculates opacities directly from a comprehensive library of 500,000 spectral lines ( 24 ) . Previous comparisons between PHOENIX and non-spherical ATLAS models have shown small but wavelength-dependent differences. For the M4 giant star \psi Phoenicis, 41 found differences of \sim 1.5% in the resulting diameter values in the K -band using VLTI data. For the F5 star Procyon, 4 found no differences in the K -band, but by 1.1% at visible wavelengths (500nm) using data from the Mark III interferometer. For our analysis, the PHOENIX intensity profile and squared visibility for the best-matched grid points are plotted alongside those of SATLAS in Figure 1 ( 10 ) . By visual inspection, the only discernible difference appears in the intensity at the outer edge of the stellar disk. The difference between the squared visibilities is \lesssim 0.006 across both the plotted range and the spatial frequency range where the HD 360 data are fit. These differences are significantly smaller than the measurement uncertainties, demonstrating consistency between SATLAS and PHOENIX models for angular diameter determination of HD 360. The angular-size measurement depends on the model of the stellar intensity profile. SATLAS modifies the plane-parallel stellar atmosphere program ATLAS to treat spherically extended geometry. ATLAS calculates line blanketing using opacity distribution functions, which average the contributions of different atomic and molecular species. 17 estimate the model error contribution to the angular size by considering intensity profiles at neighboring temperature, effective gravity, and stellar mass grid points. PHOENIX is an alternative stellar atmosphere model that is inherently spherically symmetric and calculates opacities directly from a comprehensive library of 500,000 spectral lines ( 24 ) . 41 compared PHOENIX and tbe non-spherical ATLAS limb darkening models for the M4 giant star \psi Phoenicis in the K -band with the VLTI , finding to \sim 1.5% differences in their resulting diameter values. For the F5 star Procyon no differences are found in the K band but there is a significantly wide range of angular diameters at visible wavelengths (500 nm) in data from the Mark III interferometer ( 4 ) . The PHOENIX intensity profile and squared visibility for the best-matched grid points are plotted with those of SATLAS in Figure 1 ( 10 ) . By visual inspection, the only discernible difference is in the intensity at the outer edge of the stellar disk. The difference between the squared visibilities is \lesssim 0.006 over the range of the plot and \lesssim 0.006 over the spatial frequency range where the HD 360 data are fit. These differences are significantly smaller than the measurement error bars, demonstrating consistency between SATLAS and PHOENIX models for this application. Despite the apparent robustness of the angular size measurements from PIONIER, we suggest that there is value in validating them with complementary interferometric measurements at multiple wavelengths that sample both the first zero and secondary maxima of the visibility function. For any given photometric band, the first zero and secondary maxima of the visibility curve provide a robust measure of the stellar angular diameter that are largely insensitive to model-dependent limb darkening effects, as demonstrated in the comparison between PHOENIX and ATLAS models shown in Figure 1 . The wavelength-dependence of the visibility amplitude, zero positions, and secondary maxima positions provides independent cross-checks of the angular size determination across the electromagnetic spectrum, as illustrated in Figure 2 , which plots the squared visibility in BVRIHK photometric bands for the intensity profiles calculated by SATLAS. Such model-independent validation is relevant because the fitting accuracy of both ATLAS and PHOENIX stellar atmosphere models degrades significantly for G and K-type stars, including Red Clump stars, due to increased molecular opacity and convective effects that are difficult to model accurately ( 6 ) . Reducing the model-dependence of the results through multi-wavelength visibility measurements would therefore substantially strengthen the reliability and precision of angular size measurements for these stellar types. Figure 2: Squared visibilities |\mathcal{V}|^{2} in B , V , R , I , H , and K for the intensity profiles calculated by SATLAS. Systematic errors in |V|^{2} measurements from amplitude interferometry, including PIONIER, present fundamental calibration challenges ( 26 ) . The primary systematic issue lies in determining the absolute normalization of visibility amplitudes, as PIONIER relies on calibrator stars to estimate instrumental transfer functions, but this process introduces systematic biases when calibrators have undetected binaries (potentially causing up to 2% systematic errors in squared visibility) or when the transfer function varies between calibrator and science observations. Additional systematic sources identified at VLTI include differential polarization effects (several percent), atmospheric biases that affect spectral channels coherently, and data processing artifacts in Fourier space bias removal during PIONIER reduction pipelines. These systematic effects are particularly problematic for precision stellar diameter measurements because they impact all observations in a given sequence similarly and propagate through the calibration chain in highly correlated ways ( 26 ) . Recent high-precision diameter measurements have revealed systematic differences of several sigma and up to 15% between well-resolved and marginally resolved interferometric observations, demonstrating that systematic errors can dominate the uncertainty budget for underresolved sources like Red Clump stars. Intensity interferometry accommodates multi-frequency observations with long baselines that can resolve the visibility function of small astronomical sources. The Hanbury Brown–Twiss effect produces coherence in the photon arrival times from a given source, a coherence that depends on the source intensity profile, the telescope baseline geometry, and the observing frequency ( 8 ; 7 ) . The measurement depends on the timing of photons arriving at multiple locations, not their mixing, making long baselines more feasible than with traditional amplitude interferometry. One of the most important science applications of intensity interferometry has been to measure the angular sizes of nearby stars, which helped establish the physical scale and fundamental properties of stellar objects ( 21 ; 22 ) . These pioneering measurements provided the first direct determinations of stellar diameters and established the effective temperature scale for early-type stars, fundamentally advancing stellar astrophysics ( 11 ) . In the current era, kilometer-scale intensity interferometers utilizing arrays of optical air Cherenkov telescopes can achieve microarcsecond angular resolution, which will reveal unprecedented details across stellar surfaces and in their immediate circumstellar environments ( 33 ; 13 ) . Measurements of stellar diameters are coming from the Cherenkov telescopes VERITAS, MAGIC, and H.E.S.S. 2 ; 43 ; 39 ; 3 ; 39 and deployments at 1m to 2m class telescopes 42 ; 30 . An advantage of intensity interferometry over amplitude interferometry is its intrinsic independence from electromagnetic phase information. Unlike amplitude interferometry, which measures the coherent superposition of light waves and therefore requires exquisite phase stability, intensity interferometry measures second-order correlations in photon arrival times. While atmospheric turbulence, mechanical vibrations, and optical path instabilities do affect arrival times, they are currently dwarfed by the dominant contribution of jitter in current detectors, and thus do not significantly contribute to the systematic error budget of intensity interferometry. The technique does not require combining light coherently, eliminating systematic errors associated with beam combination optics, polarization mismatch, and the complex calibration chains needed to extract visibility amplitudes and closure phases. However, intensity interferometry introduces its own set of systematic challenges. The primary sources of systematic error include: clock synchronization uncertainties between the focal positions of widely separated telescopes, which directly affect the measured temporal correlations; baseline determination errors, as precise knowledge of telescope separations is essential for converting measured correlations to angular scales; the finite extent of the individual telescope mirrors, which is not accounted for in the visibility calculation; background noise and accidental coincidences, which can bias correlation measurements, particularly for faint sources. The impact of systematic errors on squared visibility measurements varies depending on the baseline regime. As evident from Figure 2, measurements obtained along the steeply declining slopes of the visibility function are highly sensitive to systematics that affect the amplitude, since a systematic change in the amplitude or slope of |\mathcal{V}^{2}| translates to a change in the baseline-dependent slope upon which the stellar diameter determination depends. Conversely, measurements obtained near the local maxima of |\mathcal{V}^{2}| —such as at zero baseline or at baselines that cover the secondary peaks arising from the limb-darkened stellar disk—exhibit substantially reduced sensitivity to distortions caused by systematics. At these critical points, the gradient \partial|\mathcal{V}^{2}|/\partial u approaches zero, making the measured baseline position of the extrema less sensitive to calibration errors. This behavior is analogous to measurements of the Baryon Acoustic Oscillation (BAO) peak in the cosmic matter power spectrum, where the characteristic scale of the acoustic feature can be robustly determined even in the presence of errors that can affect the overall shape. This suggests an observational strategy where multiple baselines sampling the local extrema of the visibility function could provide internally consistent diameter estimates that are less susceptible to systematic contamination than measurements relying solely on the steep visibility slope. With interferometry in optical bands as opposed to H , the baseline required to meet the resolution criterion decreases. For example, D=138 m is required to resolve 1 mas in the V -band. Several current and planned intensity interferometry facilities can achieve the baseline distances required for intensity interferometry of Red Clump stars. The Cherenkov Telescope Array Observatory (CTAO) represents a promising platform, with its planned arrays offering multiple telescopes separated by distances of 100-300 meters ideal for microarcsecond angular resolution ( 9 ) . The CTAO’s Southern Array will include 37 4.3 m Small-Sized Telescopes, improving measurement precision through simultaneous multi-baseline observations ( 1 ) . Discussions are underway to connect the Very Large Telescope’s Unit Telescopes and the VISTA telescope. Additional promising sites for intensity interferometry include using additional baselines at Calern Plateau ( 31 ) , linking existing telescopes at Mauna Kea ( 25 ) , Cerro Pachón, Cerro Tololo, and Las Campanas observatories in Chile, and the Gran Telescopio Canarias and William Herschel Telescope telescopes at La Palma. Additionally, existing amplitude interferometry facilities that could operate at optical wavelengths with such baselines include VLTI and the Center for High Angular Resolution Astronomy (CHARA) array at Mount Wilson Observatory ( 38 ; 36 ) [Robin]. In Section II we present the theoretical framework for extracting limb-darkened angular diameters from intensity interferometry measurements, developing the mathematical formulation that relates stellar intensity profiles to squared visibility functions and deriving the Fisher information bounds for angular diameter precision. In Section III we demonstrate the application of this framework to validate surface-brightness-color relationship determinations for Red Clump stars, showing that intensity interferometry can achieve angular-diameter uncertainties of 3% for representative targets like HD 17652 using realistic instrumental parameters, and that multi-wavelength observations sampling visibility nulls and secondary maxima provide model-independent cross-checks of the angular diameter measurements that underpin precision distance scale calibration. II Intensity Interferometry Measurement of Angular Diameters Interferometry involves measuring a source during an exposure time with a telescope at position \mathbf{x} separated from another telescope by a baseline \mathbf{B} . The source is conveniently described by its normalized first- and second-order coherence functions \displaystyle g^{(1)}(\mathbf{B},\Delta t) \displaystyle=\frac{\langle E^{*}(\mathbf{x},t)E(\mathbf{x}+\mathbf{B},t+\Delta t)\rangle}{\sqrt{\langle I(\mathbf{x},t)\rangle\langle I(\mathbf{x}+\mathbf{B},t+\Delta t)\rangle}} (2) \displaystyle g^{(2)}(\mathbf{B},\Delta t) \displaystyle=\frac{\langle E^{*}(\mathbf{x},t)E^{*}(\mathbf{x}+\mathbf{B},t+\Delta t)E(\mathbf{x}+\mathbf{B},t+\Delta t)E(\mathbf{x},t)\rangle}{\langle I(\mathbf{x},t)\rangle\langle I(\mathbf{x}+\mathbf{B},t+\Delta t)\rangle}. (3) g^{(1)} describes the correlation between the electric field (for a single polarization) at two telescopes, relevant for amplitude interferometry, whereas g^{(2)} describes the correlation between photon detection, relevant for intensity interferometry. For chaotic light sources, such as stars, the coherence functions depend only on the intensity. When considering a narrow bandwidth \Delta\nu , over which the intensity can be treated as being constant, the spatial and temporal components are separable. For an axially symmetric source with intensity I(\theta) , where \theta is the angle from the star center, \displaystyle g^{(1)}(u) \displaystyle=\mathcal{V}(u)=\frac{\int_{0}^{\infty}{I(\theta)J_{0}(2\pi u\theta)\theta d\theta}}{\int_{0}^{\infty}{I(\theta)\theta d\theta}} (4) \displaystyle g^{(2)}(u,\Delta t) \displaystyle=1+|\mathcal{V}(u)|^{2}|g^{(1)}(\Delta t)|^{2}, (5) where u=|\mathbf{B}|/\lambda for wavelength \lambda and J_{0} is the Bessel function of the first kind. |g^{(1)}(\Delta t)|^{2}=\text{sinc}^{2}{(\pi\Delta\nu\Delta t)} , the Fourier transform of the unit top-hat function squared. The first equation is from the van Cittert-Zernike theorem and the second is the Siegert relation. \mathcal{V}(u) is often referred to as the normalized visibility. The measurement in intensity interferometry is the correlation between photon arrival times at two detector positions. It is generated my making the normalized histogram of the difference in photon arrival times at the two telescopes. The expected signal for the source is given by g^{(2)} in Eq. 5 . The |g^{(1)}(\Delta t)|^{2} term contributes to the height and shape of the histogram, while |\mathcal{V}(u)|^{2} contributes to the height. The measurement is only possible because of the Hanbury Brown and Twiss effect, i.e., |g^{(1)}(\Delta t)|^{2}\neq 0 . The intensity profile information is encoded in the visibility. The squared visibilities |\mathcal{V}|^{2}(u) predicted for representative Red Clump stars are shown in Figures 1 and 2 . The expected signal to noise ratio can be expressed as \text{SNR}=\frac{|\mathcal{V}|^{2}}{\sigma_{|\mathcal{V}|^{2}}}, (6) where \sigma^{-1}_{|\mathcal{V}|^{2}}=\frac{d\Gamma}{d\nu}\left(\frac{T_{\text{obs}}}{\sigma_{t}}\right)^{1/2}\left(128\pi\right)^{-1/4}, (7) \Gamma is the mean rate of photons, d\Gamma/d\nu=\epsilon AF_{\nu}/(h\nu_{0}) , where \epsilon is the instrumental throughput, A the collecting area of the telescope, and F_{\nu} the specific flux. The observing time is T_{\text{obs}} and \sigma_{t} is the detector timing jitter. This expression for the signal to noise ratio is valid under the following conditions: the source is chaotic and unpolarized, the observational bandpass (centered at frequency \nu_{0} with bandwidth \Delta\nu ) is sufficiently narrow that the visibility does not vary significantly across the bandpass, and yet sufficiently broad to satisfy \sigma_{t}\Delta\omega\gg 1 , where \Delta\omega=2\pi\Delta\nu ( 12 ) . This latter condition means that the detector timing jitter blurs the timing more than the different frequencies transmitted through the finite bandwidth. In the opposite regime where detector jitter is negligible, \sigma_{t}\Delta\omega\ll 1 , \sigma^{-1}_{|\mathcal{V}|^{2}}=\frac{d\Gamma}{d\nu}\left(T_{\text{obs}}\Delta\omega\right)^{1/2}\left(12\pi\right)^{-1/2}. (8) This noise depends on bandwidth \Delta\omega and is lower than that of Equation 7 . However, achieving this regime would require spectral resolution R>10000 to get narrow enough passbands for the timing jitters of >10 ps characteristic of current detectors to be subdominant. Given the complications of building a high-dispersion instrument, we restrict ourselves to the detector-jitter-dominated case. We evaluate and present in Table 1 inverse noises for observations with two 4-m telescopes in several passbands. The instrumental parameters are: a photon-counting detector with 42.4 ps FWHM timing jitter 29 (corresponding to \sigma_{t}=16.6 ps standard deviation), an overall throughput of 0.3, and an integration time of T_{obs}=1 h. The \sigma_{t}\Delta\omega\gg 1 condition translates to a condition on the bandwidth, \Delta\nu\gg 9.6 GHz in frequency or \Delta\lambda\gg 0.32 Å at 1 micron wavelength. Two stars, HD 360 and HD 17652, are presented as representative examples spanning the faint/small and bright/large extremes of the sample. Specific fluxes in the V , H , and K bands for the target stars are taken from 17 ; 34 . Fluxes in the R and I bands are interpolated in wavelength space from the measured V , H , and K fluxes together with Gaia G , BP , and RP magnitudes. These magnitudes are given in Table 2 . Star V R I H K HD 360 7.07 9.81 17.02 47.31 41.82 HD 17652 28.93 40.37 69.70 188.53 168.63 Table 1: Inverse noise \sigma^{-1}_{|\mathcal{V}|^{2}} for the stars HD 360 and HD 17652 for two 4-m telescopes in VRIHK passbands. The instrumental parameters are: a photon-counting detector with 42.4 ps FWHM timing jitter, an overall throughput of 0.3, and an integration time of T_{obs}=2 h. This is equivalent to the signal-to-noise ratio at zero baseline. The parameter uncertainty of s is bounded using the Fisher information matrix through the Cramér-Rao bound \text{Var}(s)\geq F_{ss}^{-1}=\left(\sum\left(2\mathcal{V}\frac{\partial\mathcal{V}}{\partial s}\right)^{2}\sigma_{|\mathcal{V}|^{2}}^{-2}\right)^{-1}, (9) where the sum is over all measurements and \frac{\partial\mathcal{V}}{\partial s}=-\frac{2\pi u}{s}\frac{\int_{0}^{\infty}{I(\theta)J_{1}(2\pi u\theta)\theta^{2}d\theta}}{\int_{0}^{\infty}{I(\theta)\theta d\theta}}. (10) The intensity profile of a star is given by I(\theta) , where \theta represents the angular separation between the stellar center and a given point on the stellar disk as seen from the observer and axial symmetry is assumed. The SATLAS library provides a model for the normalized profile as I_{0}(\theta) for a model red giant stars with angular diameter \theta_{0} , on a grid of effective temperature, surface gravity, and mass. Making the angular diameter a free parameter, the model profile can be expressed in terms of the SATLAS model as I(\theta;s)\propto I_{0}(\theta/s), (11) for a star with angular diameter s\theta_{0} . The parameter s represents the angular scale of the star. The uncertainty in the fit parameter s , the relative size of the star, is estimated as \sigma_{s}=\sqrt{F_{ss}^{-1}} , representing the Cramér-Rao lower bound. The expected measurement precision for the observation configuration described above and the two stars, HD 360 and HD 17652, are presented as representative examples spanning the faint/small and bright/large extremes of the sample. HD 360 has an angular diameter \theta=0.906 mas and V=5.986 mag, while HD 17652 has \theta=1.835 mas and V=4.456 mag. The stars have effective temperatures of 4764K and 4786K, respectively. Figure 3 shows the scale parameter uncertainty \sigma_{s} as a function of baseline B for several photometric bands. The measurement precision is strongest in the H band for both stars, as their cool temperatures produce peak flux in the near-infrared where photon counts are highest. For HD 17652, the uncertainty in s reaches a minimum of \sigma_{s}\sim 0.1 at baselines of B\sim 50 –70 m in optical bands, before the star becomes resolved (the first null in the visibility function occurs) at B\sim 100 m. In the H and K bands, the measurement precision improves to \sigma_{s}\lesssim 0.01 at B\sim 150 m, with the first null occurring at B\sim 300 m. HD 360, being smaller and fainter, requires commensurately longer baselines to achieve comparable angular resolution and exhibits higher uncertainties due to lower photon flux. Figure 3: Estimated uncertainty in the scale factor parameter s . \sigma_{s} for (Top) HD 360 and (Bottom) HD 17652 . The measurement noise is based on two 4-m telescopes separated by a baseline distance B , a photon detector detector with 42.4 ps FWHM timing jitter,an overall instrumental throughput of 0.3, and an exposure time is set to T_{obs}=2 h. The dashed horizontal line is the scale uncertainty for these stars as measured in the H -band using PIONIER ( 17 ) . III Validation of the SBC Determination The Red Clump surface-brightness-color relationship measured by 34 is based on high signal-to-noise data, results in small residual dispersion, and demonstrates internal consistency. The per-star angular diameter uncertainties have a mean of 0.015 mas with a standard deviation of 0.006 mas; the fractional (logarithmic) uncertainties, which correspond to uncertainties in our s parameter, have a mean of 0.012 and standard deviation of 0.006 . The uncertainties for the specific cases of HD 360 and HD 19652 are plotted in Figure 3 . Note that fractional angular-diameter uncertainties transform directly to relative distance uncertainties. The per-star surface brightness uncertainties have a mean of 0.03 mag/arcsec 2 with a standard deviation of 0.01 mag/arcsec 2 . The SBC relationship derived from these measurements exhibits an r.m.s. scatter of 0.018 mag/arcsec 2 , comparable to the individual measurement uncertainties and implies a distance precision of 0.8%. Furthermore, no extreme outlier stars deviate from the fitted SBC relationship. However, the systematic errors mentioned earlier could potentially impact the normalization of the |\mathcal{V}|^{2} measurement and the angular diameter fits, leading to an offset in the SBC determination. A consistency check with intensity interferometric measurements, which have a distinct systematic error propagation into angular diameter, would provide a direct constraint on the systematic component of the SBC relation error budget. Any potential bias between PIONIER and intensity interferometry angular diameters would be revealed by a statistically significant non-zero offset in the ensemble distribution of per-star size differences. To optimize the precision of the size-difference uncertainties, the PIONIER and intensity interferometry measurements should contribute equally to the total error; therefore, the new measurements should aim to achieve comparable per-star uncertainties to those of the PIONIER measurements. Different intensity interferometry observations provide varying tests of systematics. The most direct comparison would use measurements that replicate those of PIONIER: in the H -band with baselines from 45–140 m. Any inconsistencies in angular diameters would be due to error in the processing and interpretation of either data and be insensitive to stellar modeling. As seen in Figure 3 , for the relatively large and bright HD 17652, the lowest uncertainty in s for a 2-hour exposure time is \sigma_{s}<0.007 and is slightly lower than that of 17 occurring in the H band at a baseline of slightly over 100 m. For the relatively small and faint HD 360, the lowest uncertainty in s is \sigma_{s}<0.03 and is slightly higher than that of 17 at a baseline of slightly over 100 m. Limb-darkening models predict intensity profiles that are wavelength-dependent, as illustrated in Figure 1 . Observations in multiple wavelengths not only collectively contribute to the measurement of angular diameters but also provide a means to reduce systematic errors due to modeling or enable comparisons between models. The uncertainties in s in Figure 3 relative to the H -band increases by a factor \sim 2 –10 going blueward from I to V bands, with decreasing optimal baselines, whereas in the K -band \sigma_{s} slightly increases with an optimal baseline that is doubled. To recover the minimal H -band \sigma_{s} in other bands, which have 2–10 times larger uncertainties at the same exposure time, would require integration times that are 4–100 times longer than the fiducial. With longer baseline observations, it becomes possible to approach the Rayleigh resolution criterion, which, in principle, could yield angular diameters that are less sensitive to limb-darkening modeling. However, the resolution criterion is technically achieved when the visibility reaches its first zero, at which point the signal vanishes. As a practical alternative, we consider measuring the secondary maximum, which, when combined with the primary-maximum measurement, provides a means to reduce systematic errors or enable comparisons between models at a single wavelength. Here, the uncertainties in s in Figure 3 relative to the per-band minimum are larger by a factor of \sim 10 , meaning that a 100-times longer exposure time would be required to recover the minimum uncertainty. There are several approaches to extend the fiducial observation to increase the effective exposure time by factors of 4–10000 to achieve the target signal to noises at wavelengths other than the H band or at the secondary peak of the visibility function. The most straightforward is to dedicate the telescope time for the longer exposures. Otherwise, one could exploit the multiplex advantage of observing multiple bandpasses simultaneously—for example, the requisite signal could be obtained by increasing the effective exposure time by dispersing the light dispersed onto 4 to 100 channel SPAD arrays (ensuring that the \sigma_{t}\Delta\omega\gg 1 condition holds) and increasing the exposure time to make up for what could not be gained through multiplexing. Interferometry with simultaneous observation of N telescopes offers {N\choose 2} unique baselines. For N=37 telescopes ( 37 , the number of Small-Sized Telescopes planned for the Cherenkov Telescope Array Observatory-South) , this yields an effective increase by a factor of 666 to the nominal exposure time. Validation of the 34 result does not require re-measurement of all stars, but rather testing for inconsistency in measured angular sizes of a sufficient large subset of stars. If the validation sample has the same per-star surface brightness uncertainty of 0.03 mag/arcsec 2 , the uncertainty on the mean surface brightness of N stars scales as 0.03/\sqrt{N} mag/arcsec 2 . To detect a systematic offset comparable to the intrinsic scatter of the SBC relationship ( 0.018 mag/arcsec 2 ) at 3\sigma significance would require (3\times 0.03/0.018)^{2}\approx 25 stars. These estimates suggest that a validation sample of approximately half of the 48 Red Clump stars with comparable measurement precision would provide sufficient statistical power to test for significant inconsistencies with the 34 calibration. The stars with the most easily measurable sizes, those that are brightest to first order, can be prioritized for observation; this approach is justified as there is currently no evidence of bias in the existing SBC relationship as a function of observed or intrinsic size, magnitude, distance, or color. IV Conclusions We have examined the feasibility of using intensity interferometry to measure limb-darkened angular diameters of Red Clump stars, a stellar population crucial for precision distance scale calibration. The technique offers several advantages as a complement to traditional amplitude interferometry: First, measurements at the primary peak of the visibility function in the H band with baselines of approximately 100 m can directly replicate the PIONIER configuration, achieving comparable precision and enabling direct validation of existing measurements. This provides an independent cross-check of the angular diameters that underpin current SBC relationship calibrations. Second, and perhaps more importantly, multi-wavelength observations that probe the secondary visibility maximum provide powerful diagnostics for systematic uncertainties. The first visibility null and secondary peaks are largely insensitive to detailed limb-darkening prescriptions, as demonstrated by the close agreement between PHOENIX and SATLAS models at these positions. By measuring angular diameters at multiple wavelengths that sample different features of the visibility function, we can assess and mitigate model-dependent systematics that limit the accuracy of single-wavelength measurements. Third, modern detector technology and telescope arrays offer practical paths to achieving the required signal-to-noise ratios. The multiplex advantage of dispersing light onto multi-channel SPAD arrays can reduce observing times by factors of \sim 100, while large telescope arrays like the Cherenkov Telescope Array Observatory provide hundreds of simultaneous baselines. For HD 17652 observations at bluer wavelengths, combining these advantages reduces the required observing time from \sim 100-1000 hours to order one hour of single-channel exposure time. Fourth, the model-independent validation provided by multi-wavelength intensity interferometry becomes particularly valuable for G and K-type stars, including Red Clump stars, where stellar atmosphere models face significant challenges in accurately representing molecular opacity and convective effects. By reducing reliance on model-dependent corrections, intensity interferometry can strengthen the reliability of the Red Clump star sample used for SBC calibration. Conversely, intensity interferometry data provide powerful diagnostics of stellar atmospheric structure ( 41 ) . Dispersing the light into narrow spectral passbands covering specific absorption lines enables the measurement of wavelength-dependent stellar radii, which can reveal the vertical stratification of different chemical species in the stellar atmosphere ( 5 ) . These measurements directly probe the validity of atmospheric models and can constrain physical processes such as convection, chromospheric extension, and opacity sources. The Red Clump stars in the 34 calibration sample are well-suited for intensity interferometry measurements with foreseeable instrumentation. These stars and their characteristics are given in Table 2 . Having been observed at the VLTI, the stars predominantly have southern declinations. As demonstrated by the representative examples HD 360 and HD 17652, these stars are sufficiently bright ( V\sim 4 –6 mag) and subtend large enough angular diameters ( \theta\sim 0.9 –1.8 mas) to enable precise angular diameter measurements. The Fisher information analysis indicates that scale parameter uncertainties of \sigma_{s}\lesssim 0.1 are achievable with modest baseline configurations ( B\sim 50 –150 m) and realistic observing times; this means that intensity interferometry can obtain the same precision as PIONIER per star in the H -band. Varying degrees of improvements to the fiducial observing setup, increased exposure times, wavelength multiplexing, multiple baselines, can enable these precisions. There is no evidence for systematic bias in the measured stellar surface brightnesses as a function of angular diameter or magnitude, so the larger–brighter stars can be preferentially targeted. Star RA Dec LD V H K G G_{\rm BP} G_{\rm RP} (deg) (deg) (mas) (mag) (mag) (mag) (mag) (mag) (mag) HD 360 2.072898 -8.824267 0.906\pm 0.014 5.986\pm 0.005 3.757 3.653 5.7161 6.2276 5.0448 HD 3750 9.966729 -44.796215 1.003\pm 0.019 6.004\pm 0.005 3.612 3.485 5.6986 6.2520 4.9956 HD 4211 11.051806 -38.421153 1.100\pm 0.009 5.877\pm 0.028 3.426 3.295 5.5776 6.1534 4.8595 HD 5722 14.682634 -11.380039 0.995\pm 0.018 5.618\pm 0.012 3.496 3.381 5.3585 5.8446 4.7112 HD 8651 21.170044 -41.492704 1.228\pm 0.011 5.418\pm 0.006 3.142 3.019 5.1293 5.6539 4.4506 HD 9362 22.813872 -49.072018 2.301\pm 0.017 3.943\pm 0.006 1.748 1.638 3.6709 4.2119 3.0016 HD 10142 24.614439 -36.528792 0.964\pm 0.004 5.938\pm 0.009 3.679 3.557 5.6592 6.1767 4.9770 HD 11977 28.734768 -67.646977 1.528\pm 0.010 4.686\pm 0.011 2.594 2.486 4.4194 4.9082 3.7848 HD 12438 30.310783 -30.002314 1.091\pm 0.015 5.344\pm 0.007 3.281 3.176 5.0951 5.5600 4.4722 HD 13468 32.899263 -1.825569 0.886\pm 0.009 5.934\pm 0.013 3.783 3.666 5.6801 6.1648 5.0257 HD 15220 36.647143 -20.042165 1.185\pm 0.015 5.881\pm 0.006 3.342 3.199 5.5369 6.1423 4.7953 HD 15248 35.716699 -73.645740 0.949\pm 0.018 6.001\pm 0.003 3.669 3.553 5.7000 6.2386 5.0082 HD 15779 38.039157 -1.035031 1.185\pm 0.013 5.357\pm 0.013 3.186 3.067 5.0935 5.5955 4.4389 HD 16815 40.167597 -39.855498 2.248\pm 0.009 4.109\pm 0.003 1.820 1.706 3.8217 4.3671 3.1358 HD 17652 42.273032 -32.405189 1.835\pm 0.010 4.456\pm 0.005 2.256 2.139 4.1799 4.6882 3.5129 HD 17824 42.759445 -21.004108 1.391\pm 0.013 4.764\pm 0.010 2.781 2.668 4.5227 4.9889 3.9090 HD 18784 45.292228 -7.663325 1.036\pm 0.013 5.748\pm 0.004 3.456 3.353 5.4710 5.9946 4.7948 HD 23319 55.708052 -37.313829 2.033\pm 0.010 4.583\pm 0.005 2.141 1.995 4.2501 4.8389 3.5322 HD 23526 56.539012 6.803286 0.915\pm 0.020 5.909\pm 0.008 3.744 3.634 5.6516 6.1449 4.9928 HD 23940 56.983635 -30.168911 1.093\pm 0.020 5.543\pm 0.007 3.344 3.229 5.2567 5.7565 4.5963 HD 30814 72.548613 -16.216927 1.310\pm 0.008 5.041\pm 0.010 2.898 2.791 4.7697 5.2635 4.1158 HD 36874 83.281322 -35.139494 1.118\pm 0.010 5.768\pm 0.010 3.364 3.242 5.4468 6.0011 4.7516 HD 39523 87.457574 -56.166990 1.939\pm 0.013 4.500\pm 0.006 2.160 2.036 4.1727 4.7544 3.4993 HD 39640 87.721778 -52.109215 1.251\pm 0.016 5.163\pm 0.005 3.040 2.921 4.8983 5.3940 4.2426 HD 39910 88.875836 -4.616633 1.090\pm 0.006 5.863\pm 0.005 3.451 3.315 5.5491 6.1156 4.8321 HD 40020 89.206515 11.520808 1.012\pm 0.022 5.876\pm 0.003 3.543 3.419 5.5960 6.1384 4.9029 HD 43899 94.255140 -37.737073 1.264\pm 0.016 5.557\pm 0.015 3.134 3.004 5.2169 5.7830 4.5128 HD 46116 96.369139 -69.689408 1.145\pm 0.030 5.373\pm 0.005 3.206 3.103 5.1133 5.6067 4.4649 HD 53629 106.196116 -22.031844 1.065\pm 0.023 6.085\pm 0.006 3.556 3.410 5.7438 6.3377 5.0087 HD 56160 108.712965 -27.038125 1.411\pm 0.010 5.580\pm 0.000 2.976 2.823 5.2113 5.8384 4.4564 HD 60060 112.498674 -52.650917 0.948\pm 0.009 5.872\pm 0.002 3.662 3.545 5.5971 6.1015 4.9329 HD 60341 113.331633 -19.412838 1.190\pm 0.021 5.645\pm 0.015 3.264 3.126 5.3287 5.8823 4.6301 HD 62713 115.925475 -40.934506 1.446\pm 0.010 5.134\pm 0.017 2.782 2.654 4.8145 5.3657 4.1204 HD 68312 122.887321 -7.772651 1.020\pm 0.022 5.359\pm 0.008 3.390 3.279 5.1193 5.5721 4.5099 HD 74622 130.586174 -55.774374 1.020\pm 0.014 6.279\pm 0.010 3.672 3.532 5.9088 6.5086 5.1706 HD 75916 133.128312 -13.232945 1.013\pm 0.020 6.117\pm 0.009 3.653 3.516 5.7979 6.3678 5.0819 HD 176704 285.615194 -24.847612 1.317\pm 0.010 5.645\pm 0.005 3.107 2.956 5.2825 5.8831 4.5515 HD 191584 303.099206 -42.780502 1.024\pm 0.021 6.211\pm 0.012 3.664 3.512 5.8598 6.4595 5.1213 HD 219784 349.706129 -32.532377 2.117\pm 0.023 4.412\pm 0.008 2.019 1.886 4.0769 4.6631 3.3808 HD 220572 351.331793 -56.849071 1.092\pm 0.012 5.605\pm 0.020 3.350 3.224 5.3153 5.8379 4.6387 HD 204381 322.181482 -21.807204 1.524\pm 0.015 4.501\pm 0.008 2.537 2.426 4.2685 4.7183 3.6513 Table 2: Stars used to calibrate the Red Clump SBC relationship. RAs and Decs are from Gaia ( 15 ) . The angular diameter LD and V are from 34 . The original source of the H and K magnitudes is 27 . The remaining columns are Gaia G -band magnitude, and Blue Photometer ( G_{\text{BP}} ) and Red Photometer ( G_{\text{RP}} ) magnitudes. The local stars used to calibrate the SBC relationship establish an important rung of the cosmic distance ladder used to determine the Hubble constant H_{0} . The more distant Large Magellanic Cloud (LMC) hosts Red Clump stars in detached eclipsing binary systems, whose physical radii are determined using spectroscopic and photometric measurements. The angular diameters of these LMC stars are inferred from the SBC relationship established by the calibrator stars. The distance to the LMC is then determined from the ratio of the angular and physical diameters ( 34 ) . With this precisely known distance, the LMC serves as a crucial anchor for calibrating the Cepheid period-luminosity relationship, as it hosts thousands of Cepheid variable stars ( 35 ) . Similarly, the Tip of the Red Giant Branch has been absolutely calibrated using stars in the LMC ( 23 ) . These calibrated relationships then connect to subsequent distance rungs that extend to galaxies in the Hubble flow, enabling the determination of H_{0} . Intensity interferometry also offers new measurements that can inform the modeling of binary systems. 16 demonstrated that an extended-path intensity correlator—an optical modification that extends the traditional field of view of intensity interferometers—could determine all Keplerian orbital angles of a binary system to subdegree precision. When combined with radial velocity measurements, this technique can determine the masses of the constituent stars and the line-of-sight distance to per-mil precision or better. Intensity interferometry can thus be applied to test the robustness of current models of DEB systems. Future work should focus on demonstrating these measurements with existing or planned facilities, particularly those offering both multi-wavelength capabilities and multiple baselines. Successful validation would establish intensity interferometry as a valuable tool for expanding the calibration sample of Red Clump stars with robust, cross-checked angular diameter measurements. Acknowledgements. The authors acknowledge Pierre Astier, Eric Linder, and Peter Nugent for their insightful discussions that contributed to this work. A. G. Kim was supported by the U.S. Department of Energy (DOE), Office of Science, Office of High Energy Physics, under Contract No. DE–AC02–05CH11231. R. Kaiser acknowledges the financial support the European project IC4Stars (ERC Advanced Grant No. 101140677). This work has made use of data from the European Space Agency (ESA) mission Gaia ( https://www.cosmos.esa.int/gaia ), processed by the Gaia Data Processing and Analysis Consortium (DPAC, https://www.cosmos.esa.int/web/gaia/dpac/consortium ). Funding for the DPAC has been provided by national institutions, in particular the institutions participating in the Gaia Multilateral Agreement.