Cyst-X: AI-Powered Pancreatic Cancer Risk Prediction from Multicenter MRI in Centralized and Federated Learning Hongyi Pan, Gorkem Durak, Elif Keles, Deniz Seyithanoglu, Zheyuan Zhang, Alpay Medetalibeyoglu, Halil Ertugrul Aktas, Andrea Mia Bejar, Ziliang Hong, Yavuz Taktak, Gulbiz Dagoglu Kartal, Mehmet Sukru Erturk, Timurhan Cebeci, Maria Jaramillo Gonzalez, Yury Velichko, Lili Zhao, Emil Agarunov, Federica Proietto Salanitri, Concetto Spampinato, Pallavi Tiwari, Ziyue Xu, Sachin Jambawalikar, Ivo G. Schoots, Marco J. Bruno, Chenchang Huang, Candice Bolan, Tamas Gonda, Frank H. Miller, Rajesh N. Keswani, Michael B. Wallace, Ulas Bagci Abstract Pancreatic cancer is projected to become the second-deadliest malignancy in Western countries by 2030, highlighting the urgent need for better early detection. Intraductal papillary mucinous neoplasms (IPMNs), key precursors to pancreatic cancer, are challenging to assess with current guidelines, often leading to unnecessary surgeries or missed malignancies. We present Cyst-X , an AI framework that predicts IPMN malignancy using multicenter MRI data, leveraging MRI’s superior soft tissue contrast over CT. Trained on 723 T1- and 738 T2-weighted scans from 764 patients across seven institutions, our models (AUC=0.82) significantly outperform both Kyoto guidelines (AUC=0.75) and expert radiologists. The AI-derived imaging features align with known clinical markers and offer biologically meaningful insights. We also demonstrate strong performance in a federated learning setting, enabling collaborative training without sharing patient data. To promote privacy-preserving AI development and improve IPMN risk stratification, the Cyst-X dataset is released as the first large-scale, multi-center pancreatic cysts MRI dataset. keywords IPMN, Pancreatic Cancer, Segmentation, Classification, Federated Learning 1 Introduction Pancreatic cancer remains one of the deadliest malignancies worldwide, characterized by high mortality and poor prognosis, largely due to late-stage diagnosis Stoffel et al. 2023 . Although long-term survival is possible with early detection of lesions with malignant potential, most patients with pancreatic cancer present irrecoverable stages Balaban et al. 2016 . Pancreatic cystic lesions (PCLs), particularly intraductal papillary mucinous neoplasms (IPMNs), represent a vital opportunity for early intervention, as they constitute identifiable precursors from which 15-20% of pancreatic cancers arise Tanaka et al. 2017 . The clinical significance of these lesions has grown with improvements in cross-sectional imaging, longer lifespans, and increasing risk factors, with IPMN incidence now estimated at up to 49.1% on magnetic resonance imaging (MRI) Ohtsuka et al. 2024 . These statistics underscore the critical need for improved methods of risk stratification for PCLs, particularly IPMN, which have a significant rate of progression to pancreatic cancer Corral et al. 2019 ; Yao et al. 2023 . PCLs have an estimated prevalence ranging from 4% to 14%, with autopsy studies demonstrating a prevalence as high as 50% in older populations Seyithanoglu et al. 2024 . The primary concern associated with PCLs is their potential for malignancy, as they are among the few identifiable precursors to pancreatic ductal adenocarcinoma (PDAC) Seyithanoglu et al. 2024 ; Ohtsuka et al. 2024 . The management of pancreatic cysts is determined by their risk of malignancy, which is classified as likely benign, low risk for malignancy, or potentially containing high-grade dysplasia or invasive carcinoma. The majority of pancreatic cysts are pseudocysts, serous cystic neoplasms (SCNs), mucinous cystic neoplasms (MCNs), or IPMNs Seyithanoglu et al. 2024 . While pancreatic pseudocysts and SCNs are benign, MCNs and IPMNs pose a risk of developing pancreatic cancer Seyithanoglu et al. 2024 ; Megibow et al. 2017 . Other types of PCLs, such as solid pseudopapillary neoplasms and cystic pancreatic neuroendocrine tumors, usually require surgical resection. However, these lesions are rare and generally less aggressive than MCNs and IPMNs with high-grade dysplasia or invasive carcinoma Seyithanoglu et al. 2024 ; Megibow et al. 2017 . Accurately identifying pancreatic cysts that could lead to cancer is crucial for early intervention. Additionally, there is a need for reliable and practical assessment methods for pancreatic cysts to minimize the risks of disease progression and complications from surgery. Current clinical guidelines often struggle to accurately differentiate between high-risk and low-risk cysts Heckler et al. 2017 ; Ohtsuka et al. 2024 ; Gonda et al. 2024 . This diagnostic uncertainty results in two concerning clinical scenarios: unnecessary surgical interventions with associated morbidity in patients with benign lesions, and missed opportunities for potentially curative intervention in patients with high-grade dysplasia or early invasive carcinoma Robles et al. 2016 ; Maggi et al. 2018 ; Bulcke et al. 2021 ; Romutis and Brand 2023 . The clinical paradox is evident in recent meta-analyses showing that 65-75% of resected IPMNs harbor only low-grade dysplasia, suggesting significant overtreatment, while other studies reveal cases of malignant transformation in lesions previously classified as low-risk Yao et al. 2023 ; Heckler et al. 2017 . The primary non-invasive imaging techniques for evaluating pancreatic cysts are computed tomography (CT) and MRI/magnetic resonance cholangiopancreatography (MRCP) Vege et al. 2015 ; Megibow et al. 2017 ; Seyithanoglu et al. 2024 . Most pancreatic cysts are initially identified through CT scans, but MRI/MRCP are preferred modalities for characterizing cysts and elucidating their relationship with the pancreatic ducts Vege et al. 2015 ; on Cystic Tumours of the Pancreas et al. 2018 ; Ohtsuka et al. 2024 . MRI/MRCP offers several advantages over CT, including better sensitivity for detecting duct communications, mural nodules, multiple cysts, and iso-attenuating PDAC Ohtsuka et al. 2024 . According to the European Study Group guidelines, accuracy for identifying the specific type of PCLs is between 40% and 81% for CT and 40% and 95% for MRI/MRCP on Cystic Tumours of the Pancreas et al. 2018 . Additionally, MRI does not expose patients to ionizing radiation, making it especially valuable for individuals requiring frequent imaging as part of long-term surveillance Seyithanoglu et al. 2024 ; Megibow et al. 2017 ; Ohtsuka et al. 2024 . However, unique challenges associated with interpreting MRI of the pancreas include inter-observer differences in experience, lack of standardization across different scanners, and significant variation in pancreatic shape and size among patients. To address these challenges, machine learning—particularly deep learning—can potentially enhance the diagnostic sensitivity and accuracy of MRI and MRCP in assessing and characterizing pancreatic cystic lesions. Despite recent advances, public datasets for pancreatic imaging remain scarce and are predominantly CT-based ( e.g. , NIH Pancreas-CT Roth et al. 2015 ), constraining the development and validation of MRI-specific AI models. This scarcity underscores the novelty and importance of the Cyst-X dataset, which offers the first large-scale, multi-institutional MRI resource for pancreatic cystic lesion analysis. In addition, to overcome real-world barriers such as data silos and privacy laws like HIPAA Act et al. 1996 and GDPR Regulation 2016 , we hypothesize that federated learning enables collaborative model training without sharing patient data. Artificial intelligence (AI), particularly deep learning, has emerged as a powerful tool to improve diagnostic precision in medical imaging. While recent advances have demonstrated success across a range of radiological tasks, pancreatic imaging remains uniquely challenging due to the subtle presentation of early malignant changes and the limited availability of large, annotated datasets. These challenges are further compounded by privacy regulations and data governance policies that restrict the sharing of multi-institutional data, thereby impeding the development of robust, generalizable AI models for pancreatic disease diagnosis. In this context, prior research on pancreas segmentation and IPMN classification has laid an important foundation. Pancreas segmentation research has predominantly focused on CT imaging, with limited exploration of MRI due to data scarcity Zhang et al. 2023 . Cai et al. proposed a recurrent neural network-based approach for pancreas segmentation, achieving a dice coefficient of 76.1% on 79 in-house T1-weighted (T1W) MRI scans Cai et al. 2017 . Salanitri et al. introduced a multi-headed decoder structure that generates intermediate segmentation maps and ensembles these predictions to produce the final output. Their method achieved a dice coefficient of 77.5% on 40 in-house T2-weighted (T2W) MRI scans Proietto Salanitri et al. 2021 . To date, Zhang et al. developed the largest pancreas segmentation dataset, comprising 767 MRI scans (385 T1W and 382 T2W) from 499 participants, and the PanSegNet model achieved dice coefficients of 85.0% for T1W MRI and 86.3% for T2W MRI Zhang et al. 2025 . Despite these advances, pancreas segmentation from MRI remains an underexplored area, with significant opportunities for further research and development. For IPMN classification, early radiomics-based approaches by Chakraborty et al. Chakraborty et al. 2018 and Cui et al. Cui et al. 2021 reported AUCs up to 0.88 using features extracted from manually segmented cysts, with a predominant focus on branch-duct IPMNs. However, main-duct IPMNs, which have a significantly higher risk of malignancy Corral et al. 2019 ; Ohtsuka et al. 2024 ; Gonda et al. 2024 , remain relatively underrepresented. Deep learning methods have evolved from 2D CNN-based feature extractors Hussein et al. 2018 to fully end-to-end 3D models such as DenseINN and InceptINN LaLonde et al. 2019 , which adapt pre-trained 2D weights through an “inflation” mechanism. Corral et al. developed a CNN-based deep learning protocol to classify IPMN malignancy from MRI in a cohort of 139 cases and reported an AUC of 0.78, comparable to the Fukuoka (0.77) and American Gastroenterology Association (0.76) guidelines Corral et al. 2019 . Transformer-based models Salanitri et al. 2022 and hybrid frameworks that combine segmentation, radiomics, and deep learning predictions Yao et al. 2023 have also demonstrated improved classification performance. Despite these advances, pancreas MRI segmentation and IPMN classification remain active research areas, with an urgent need for large-scale, multi-institutional datasets and integrative models capable of leveraging both anatomical and textural features for robust malignancy risk prediction. Figure 1: Cyst-X Pipeline. (A) T1W and T2W MRI scans were collected from seven medical centers. (B) PanSegNet segments the pancreas: MRI scans are input into a pre-trained PanSegNet model to extract pancreas regions. To reduce computational cost, linear self-attention is used at the bottleneck (highlighted in yellow) instead of standard self-attention. (C) Radiomics analysis and deep learning classification assess the malignancy risk of IPMNs: In the radiomics pipeline, scans undergo resizing, bias field correction, and intensity normalization, followed by textural features extraction and a random forest classification model. In the deep learning pipeline, DenseNet-121 serves as the backbone for malignancy risk prediction. To address these challenges, we collected 1,461 MRI scans (723 T1W and 738 T2W) from 764 unique patients across seven clinic centers: New York University Langone Health (NYU), Mayo Clinic Florida (MCF), Northwestern University (NU), Allegheny Health Network (AHN), Mayo Clinic Arizona (MCA), Istanbul University Faculty of Medicine (IU), and Erasmus Medical Center (EMC). Then, we hypothesized that advanced deep learning models trained on diverse MRI data could significantly enhance IPMN risk stratification, outperforming current clinical guidelines and expert radiologist assessments. We further posited that federated learning could maintain comparable performance while preserving patient privacy and enabling cross-institutional collaboration. In summary, we present Cyst-X (illustrated in Figure 1 ), a comprehensive framework for pancreatic cyst analysis and risk stratification that makes the following contributions: 1. Large-scale multi-center dataset: Cyst-X includes 723 T1W and 738 T2W MRI images with radiologist-annotated ground truth segmentations collected from seven clinic centers. The dataset predominantly contains images of IPMNs (90-95%) and provides a significant resource for domain generalization studies, benchmarking new methods, and addressing other abdominal imaging tasks. Unlike existing CT-based datasets, Cyst-X fills a critical gap by offering MRI-based data, enabling standardized studies across diverse populations and institutions. Its combination of scale, diversity, and multi-modality makes it well-suited for developing and evaluating robust AI models in pancreatic cyst analysis and beyond. 2. Advanced segmentation and classification: We integrate PanSegNet, a state-of-the-art pancreas segmentation network, with innovative deep learning classification approaches that significantly outperform current clinical guidelines in identifying high-risk lesions. Our approach integrates radiomics with deep learning, enabling the extraction and analysis of subtle imaging features associated with malignant transformation. We also establish benchmarks for pancreas segmentation and IPMN risk classification using Cyst-X . For segmentation, we evaluate Swin-UNETR Hatamizadeh et al. 2021 and PanSegNet Zhang et al. 2025 . For IPMN pancreatic cancer risk prediction, we apply radiomics-based and deep-learning-based methods such as DenseNet-121 Huang et al. 2017 on both T1W and T2W MRI scans. 3. Privacy-preserving federated learning: We demonstrate the feasibility of training effective models across institutions without sharing sensitive patient data, addressing a critical barrier to clinical AI implementation. 4. Public resource creation: We release the Cyst-X dataset, segmentation algorithms, and classification models to accelerate research and development in pancreatic cancer early detection. This work represents a significant advancement in pancreatic cancer risk stratification, with potential implications for clinical practice, patient outcomes, and the broader application of AI in medical imaging. Our study was approved with IRB number: STU00214545 by Northwestern University. We implemented a Data User Agreement with other centers. Our IRB approval serves as a primary record, and other institutions provide our IRB protocol within their local IRBs. Our IRB waived the informed consent of the study participants. The images were de-identified at their centers and transferred to our center fully anonymized ( i.e. , the patient-protected health information was removed from the DICOM files before their transfer). 2 Results 2.1 UMAPs of quality indicators on T1W and T2W modalities UMAP (Uniform Manifold Approximation and Projection) is a technique that reduces high-dimensional data to two or three dimensions for easier visualization. We employed UMAP to analyze image quality differences across centers and assess how scanning parameters vary. Figure 2 shows the UMAPs of quality indicators on T1W and T2W modalities, respectively, plotting with different colors in each center or each range of z thickness. In the T1W projections, some clusters are composed of centers with similar z-thickness. One mixed cluster consists of the NWU and IU centers (green and brown, respectively), both of which have a mean z-thickness of 3.3 mm. Other isolated clusters are composed of EMC (pink), MCF (orange), and NYU (blue) centers, with mean z-thicknesses of 2.5 mm, 4.9 mm, and 5.3 mm, respectively. Similarly, in the T2W projections, one mixed cluster consists of the NWU and NYU centers (green and blue), with mean z-thicknesses of 5.6 mm and 5.3 mm, respectively. Other isolated clusters are composed of the EMC (pink) and MCF (orange) centers, with mean z-thicknesses of 6.8 mm and 4.9 mm, respectively. These results show the quality differences across centers and the direct impact of z-thickness on the resolution. (a) MinMax of centers. (b) Whitening of centers. (c) Z-Score of centers. Figure 2: MRQy analysis. Row 1: T1W modality MRQy of each center. Row 2: T1W modality MRQy of thickness range. Row 3: T2W modality MRQy of each center. Row 4: T2W modality MRQy of thickness range. EMC      IU     MCA     AHN      NU     MCF     NYU (a) T1W (b) Swin-UNETR (c) PanSegNet (d) T2W (e) Swin-UNETR (f) PanSegNet Figure 3: Cyst-X Segmentation Results. Annotation masks are displayed in red. Model outputs are shown in green and yellow, with green indicating the overlap between the annotation masks and the model outputs. Table 1: Benchmarking for Segmentation of Pancreas from MRIs. Method Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality PanSegNet 86.81 \pm 7.30 77.32 \pm 9.74 86.56 \pm 8.59 87.84 \pm 7.80 5.81 \pm 10.90 1.30 \pm 1.55 Swin-UNETR 79.09 \pm 1.40 67.19 \pm 1.63 79.09 \pm 1.67 81.37 \pm 0.74 26.55 \pm 8.48 7.58 \pm 3.76 +FedAvg 71.26 \pm 2.59 58.30 \pm 2.74 69.74 \pm 3.09 77.13 \pm 1.34 43.65 \pm 8.60 14.77 \pm 5.01 +FedProx( \mu =0.3) 57.24 \pm 3.41 44.16 \pm 2.85 56.85 \pm 4.33 62.93 \pm 2.80 87.27 \pm 8.34 31.99 \pm 6.19 +FedProx( \mu =0.01) 68.95 \pm 3.30 56.09 \pm 3.37 67.33 \pm 3.37 75.11 \pm 2.68 52.82 \pm 9.97 18.76 \pm 5.41 +FedProx( \mu =0.005) 69.77 \pm 2.90 56.88 \pm 2.98 68.16 \pm 2.98 75.82 \pm 2.39 49.61 \pm 8.55 17.51 \pm 5.39 T2W Modality PanSegNet 89.62 \pm 6.38 81.73 \pm 9.31 90.74 \pm 6.45 89.11 \pm 8.06 4.19 \pm 4.99 0.75 \pm 0.87 Swin-UNETR 76.29 \pm 0.66 63.77 \pm 0.82 78.70 \pm 2.14 76.86 \pm 1.21 28.53 \pm 7.01 7.57 \pm 2.60 +FedAvg 69.19 \pm 1.51 55.48 \pm 1.44 70.52 \pm 2.98 71.31 \pm 0.95 41.87 \pm 5.84 11.74 \pm 3.02 +FedProx( \mu =0.3) 58.11 \pm 2.61 43.85 \pm 2.22 59.01 \pm 4.38 61.46 \pm 1.11 66.68 \pm 9.10 20.87 \pm 4.81 +FedProx( \mu =0.01) 67.25 \pm 1.86 53.47 \pm 1.77 68.22 \pm 2.99 70.23 \pm 1.21 48.36 \pm 6.51 14.52 \pm 3.64 +FedProx( \mu =0.005) 67.82 \pm 1.44 54.16 \pm 1.43 68.63 \pm 2.41 70.89 \pm 0.84 48.64 \pm 5.82 13.99 \pm 2.96 2.2 Superior performance of PanSegNet for pancreas segmentation Accurate pancreas segmentation is a critical prerequisite for precise cyst analysis and classification. Recently, we developed PanSegNet Zhang et al. 2025 , a novel segmentation architecture incorporating linear self-attention layers Zhang and Bagci 2022 within the nnUNet framework Isensee et al. 2021 to enhance global information modeling capabilities while maintaining computational efficiency (Fig. 1 ). PanSegNet demonstrated exceptional segmentation performance across both T1W and T2W modalities, achieving mean dice scores of 86.81 \pm 7.30% and 89.62 \pm 6.38%, respectively (Table 1 , Fig. 3 b-c). This performance significantly exceeded that of Swin-UNETR Hatamizadeh et al. 2021 , one of the most used state-of-the-art transformer-based medical segmentation models, which achieved dice scores of 79.09 \pm 1.40% and 76.29 \pm 0.66% for T1W and T2W, respectively ( p<0.001 ). In this study, we integrated PanSegNet into our Cyst-X engine along with a classifier for risk prediction. In Section 2.3 , we show that the choice of segmentation model affects the classification results. The performance advantage of PanSegNet was consistent across all seven medical centers, demonstrating robust generalization despite variations in imaging protocols and equipment (Table 1 ). This cross-institutional reliability is particularly important for clinical applications, where model performance must remain consistent regardless of imaging site or acquisition parameters. Table 2: IPMN Classification Results. Performance metrics for binary classification (high-risk vs. non-high-risk IPMN) and three-class classification (no-risk, low-risk, high-risk), with multiply-accumulate operations (MACs) and parameter counts provided to compare model computational efficiency and complexity. T1W Modality T2W Modality Method MACs Param. ACC(%) AUC(%) ACC(%) AUC(%) Radiomics approach binary classification, four-fold cross-validation, multi-center dataset approach 2D Radiomics features - - 68.76 \pm 3.65 72.93 \pm 3.23 71.57 \pm 4.64 75.67 \pm 6.24 3D Radiomics features - - 76.97 \pm 3.90 77.98 \pm 5.98 72.72 \pm 3.91 75.75 \pm 4.98 Deep learning three-class classification, five-fold cross-validation, pooled dataset approach ResNet-34 183.04G 63.47M 56.62 \pm 9.13 72.01 \pm 5.27 58.57 \pm 3.81 78.63 \pm 2.04 ShuffleNet-V2 0.57G 1.3M 46.65 \pm 9.03 65.63 \pm 3.80 58.49 \pm 3.82 71.50 \pm 3.08 MobileNet-V2 2.06G 2.36M 49.52 \pm 5.30 65.49 \pm 4.64 45.48 \pm 7.88 65.76 \pm 2.25 EfficientNet-B0 1.21G 4.69M 55.49 \pm 2.75 68.07 \pm 1.57 59.37 \pm 5.78 74.41 \pm 4.10 DenseNet-121 18.31G 11.25M 58.69 \pm 4.28 75.59 \pm 7.05 65.89 \pm 4.98 81.09 \pm 4.10 Federated learning binary classification, four-fold cross-validation, multi-center dataset approach DenseNet-121, centralized 18.31G 11.24M 79.90 \pm 1.52 78.13 \pm 2.06 78.23 \pm 5.09 82.37 \pm 1.02 DenseNet-121, FedAvg 18.31G 11.24M 79.29 \pm 2.04 76.19 \pm 1.02 81.08 \pm 1.69 81.24 \pm 2.98 DenseNet-121, FedProx( \mu=0.1 ) 18.31G 11.24M 78.52 \pm 1.23 76.46 \pm 1.21 78.29 \pm 2.87 81.35 \pm 1.77 DenseNet-121, FedProx( \mu=0.3 ) 18.31G 11.24M 75.26 \pm 4.90 76.67 \pm 1.09 79.27 \pm 2.41 81.81 \pm 2.15 Benchmarking Segmentation Network+DenseNet-121 for exploring the effect of segmentation model PanSegNet+3-class DenseNet-121 - - 56.02 \pm 8.23 72.26 \pm 5.35 57.41 \pm 1.26 74.18 \pm 1.29 Swin-UNETR+3-class DenseNet-121 - - 51.72 \pm 8.75 66.95 \pm 6.62 55.55 \pm 2.74 69.63 \pm 2.92 PanSegNet+2-class DenseNet-121 - - 78.85 \pm 3.16 74.84 \pm 3.83 70.78 \pm 10.48 77.01 \pm 1.82 Swin-UNETR+2-class DenseNet-121 - - 76.82 \pm 2.44 70.20 \pm 5.07 70.47 \pm 11.47 68.92 \pm 4.55 2.3 Cyst-X classification models outperform clinical guidelines and expert radiologists We evaluated multiple approaches for IPMN risk classification, comparing radiomics-based methods with deep learning models, and benchmarking against both established clinical guidelines and expert radiologist assessments. Our 3D DenseNet-121 model achieved superior performance in distinguishing high-risk from low-risk and no-risk IPMNs (Table 2 ). In a direct comparison with the Kyoto Criteria Ohtsuka et al. 2024 , our model demonstrated significantly improved diagnostic accuracy (AUC=82.37 \pm 1.02% vs. AUC \sim 75%, p<0.01 ) for T2W images. Notably, the performance improvement was most substantial in detecting high-risk lesions (sensitivity 87.8% vs. 64.1%, p<0.001 ), which is clinically critical for preventing missed opportunities for early intervention. To further interpret the model’s feature representation, we performed t-SNE visualization of both the input images and the hidden states from the DenseNet-121. As shown in Fig. 4 , input features show limited separation across risk classes, while the learned embeddings exhibit improved clustering by risk category. This indicates that the model successfully learns discriminative representations for IPMN risk stratification. (a) T1W images. (b) T2W images. (c) T1W hidden states. (d) T2W hidden states. Figure 4: t-SNE Visualization. 0: No risk. 1: Low risk. 2: High risk. Among the classification approaches evaluated, the 3D radiomics features consistently outperformed 2D features (AUC=78.26 \pm 4.28% vs. 72.93 \pm 3.23%, p<0.05 ), highlighting the importance of volumetric analysis for capturing the complex spatial characteristics of pancreatic lesions. The 3D DenseNet-121 further improved on radiomics-based methods (AUC 82.37 \pm 1.02% vs. 78.26 \pm 4.28%, p<0.01 ), demonstrating the advantage of end-to-end deep learning for this task (Table 2 ). To assess the importance of accurate pancreas segmentation in classification, we evaluated how different ROI sources affect DenseNet-121’s performance. Specifically, we compared classification results using ROIs generated by PanSegNet and Swin-UNETR, both under centralized learning, against a baseline using radiologist-defined ROIs. As shown in Table 2 , using PanSegNet’s masks resulted in only a modest performance decline, reflecting its strong segmentation quality. In contrast, Swin-UNETR led to a more substantial drop, demonstrating that inferior segmentation can directly compromise classification. For 3-class classification, the mean AUC dropped from 75.59% (radiologist ROI) to 72.26% with PanSegNet, and further to 66.95% with Swin-UNETR on T1-weighted images. On T2-weighted scans, the AUC declined from 81.09% to 74.18% (PanSegNet) and to 69.63% (Swin-UNETR). A similar trend was observed in 2-class classification: on T1W, AUC dropped from 78.13% to 74.84% (PanSegNet) and 70.20% (Swin-UNETR); on T2W, from 82.37% to 77.01% and 68.92%, respectively. These results emphasize that accurate segmentation—particularly via PanSegNet—is not only essential for volume estimation but also critical to preserving downstream classification performance in the Cyst-X pipeline. Furthermore, when compared with the visual assessments of three expert radiologists ( n=3 ), our models demonstrated superior accuracy in both no/low-risk and high-risk cases. As shown in Table 3 , the DenseNet-121 model with probability fusion achieved a no/low-risk classification accuracy of 94.66% and a high-risk accuracy of 47.18%, outperforming the radiologists’ average accuracies of 93.91% and 46.01%, respectively. While this overall performance suggests that Cyst-X surpasses expert-level assessments, a more nuanced interpretation is warranted. Notably, Radiologist 2 achieved the highest no/low-risk classification accuracy at 97.13%, exceeding that of any model configuration. However, their high-risk accuracy was substantially lower at just 32.39%. This indicates a conservative diagnostic tendency, which is likely prioritizing avoidance of false positives at the expense of missing high-risk cases. In contrast, our model maintained a more balanced performance across risk categories, demonstrating both strong sensitivity and specificity. This balance suggests that Cyst-X is not only more accurate overall but also potentially more reliable in clinical decision-making, where both under- and over-diagnosis carry significant consequences. For visual explainability of classification results, visual saliency-based methods are often used, although most of such methods are not true explanation methods, but show mostly learned patterns in the image region in correlation to the result. For this purpose, GradCAM Selvaraju et al. 2017 and Information Bottleneck Attribution (IBA) Schulz et al. 2020 ; Demir et al. 2021 based visualizations were generated (See Supplementary materials). Table 3: Comparison of IPMN Classification Accuracy: Radiologists vs. DenseNet-121. DenseNet-121 with probability fusion outperformed the average radiologists’ performance in both no/low-risk and high-risk classification accuracy. Method Input Modality No/Low-Risk High-Risk Radiologist 1 T1W+T2W 89.94 64.08 Radiologist 2 T1W+T2W 97.13 32.39 Radiologist 3 T1W+T2W 94.66 41.55 Average T1W+T2W 93.91 46.01 DenseNet-121 T1W Only 91.38 40.85 DenseNet-121 T2W Only 86.11 53.96 DenseNet-121(feature fusion) T1W+T2W 95.69 43.66 DenseNet-121(probability fusion) T1W+T2W 94.66 47.18 2.4 Privacy-preserving federated learning maintains high performance To address privacy concerns that often restrict data sharing across institutions, we implemented and evaluated federated learning approaches for both segmentation and classification tasks. Using Federated Averaging (FedAvg) McMahan et al. 2017 and Federated Proximal (FedProx) Li et al. 2020 algorithms, we trained models across distributed datasets without sharing patient data. For the segmentation task, federated learning approaches showed reduced performance compared to centralized training, with dice score decreases of 7.83% and 7.10% for T1W and T2W modalities, respectively, using FedAvg (Table 1 ). This performance gap likely stems from the high sensitivity of segmentation tasks to data heterogeneity across institutions. In contrast, our classification models maintained robust performance in the federated setting. FedProx with \mu=0.3 achieved the best average AUCs (76.67% on T1W and 81.81% on T2W modalities) among all federated learning configurations. Its results were close to the centralized baseline, with only 1.46% and 0.56% decrease on T1W and T2W modalities, respectively. FedProx with \mu=0.1 also outperformed FedAvg, yielding AUCs of 76.46% on T1W and 81.35% on T2W, compared to FedAvg’s 76.19% and 81.24%. Since FedAvg can be treated as a special FedProx case with \mu=0 , these findings indicate that moderately strong proximal regularization stabilizes training and enhances performance in heterogeneous multi-institutional settings for the IPMN classification task. These findings are further illustrated in Fig. 5 , which shows the ROC curves for each method across both T1W and T2W modalities. Each subfigure presents the mean ROC curve over four cross-validation folds, along with individual fold performance and standard deviation bands. The centralized model consistently achieved the highest AUCs, serving as an upper-bound benchmark. Among federated methods, FedProx with \mu=0.3 produced the most favorable results, with ROC curves closely aligned with the centralized baseline. Compared to FedAvg, both FedProx configurations achieved higher mean AUCs and demonstrated reduced variability across folds, particularly on the T2W modality. These visual results corroborate our findings, demonstrating that moderately strong proximal regularization improves model generalization and stability in federated learning for multi-center IPMN classification. (a) Centralized Learning. (b) FedAvg McMahan et al. 2017 . (c) FedProx ( \mu=0.1 ) Li et al. 2020 . (d) FedProx ( \mu=0.3 ) Li et al. 2020 . Figure 5: ROC curves for Multi-Center IPMN MRI binary classification Using DenseNet-121. This preservation of classification performance in the federated setting is particularly significant, as it enables multi-institutional collaboration while maintaining regulatory compliance, a critical consideration for clinical deployment of AI tools. 3 Discussion Our study presents Cyst-X , a comprehensive AI framework for pancreatic cyst analysis and risk stratification that demonstrates superior performance compared to current clinical guidelines and expert radiologists. By leveraging deep learning on a large, multi-center MRI dataset, we have developed models capable of identifying subtle imaging features associated with malignant transformation, potentially enabling earlier intervention for high-risk lesions and reducing unnecessary procedures for benign cysts. The performance improvement over established clinical guidelines (AUC=0.82 vs. AUC=0.75) represents a clinically meaningful advance that could significantly impact patient management. The higher sensitivity for detecting high-risk IPMNs suggests potential for identifying cases that might be missed by conventional assessment, while improved specificity could reduce unnecessary surgical interventions and their associated morbidity. This balance is particularly crucial in pancreatic cyst management, where both under-treatment and over-treatment carry significant consequences. Perhaps equally important is our demonstration that these models can be effectively trained in a federated learning environment without compromising performance. This approach addresses critical barriers to clinical AI implementation, enabling institutions to collaborate while maintaining regulatory compliance and preserving patient privacy. The slight performance reduction observed in federated versus centralized learning (AUC decrease of approximately 0.01-0.02) represents a reasonable trade-off for these substantial privacy benefits. The integration of advanced segmentation through PanSegNet with classification models represents a comprehensive approach to pancreatic imaging analysis. By first accurately delineating the pancreas, which is a notoriously challenging organ to segment, our system creates a foundation for more precise feature extraction and classification. The superior performance of 3D compared to 2D radiomics features further emphasizes the importance of comprehensive volumetric analysis in capturing the complex spatial characteristics of pancreatic lesions. While PanSegNet achieved high segmentation accuracy overall, its performance was modestly lower in the federated learning setting compared to centralized training. This performance gap highlights a well-known challenge in federated learning for segmentation tasks, particularly under high data heterogeneity across institutions. To address this, future work could explore advanced aggregation methods such as Federated Matched Averaging (FedMA) Wang et al. 2020 , which aligns intermediate representations prior to model fusion, thereby reducing inter-site domain discrepancies. Additionally, techniques from federated domain adaptation Peng et al. 2019 ; Yao et al. 2022 , federated domain generalization Liu et al. 2021 ; Zhang et al. 2023 ; Pan et al. 2024 ; Pan et al. 2025 , and cycle-consistency constraints Kassem et al. 2022 may further enhance robustness to distributional shifts. These strategies offer promising avenues to close the segmentation performance gap in federated learning settings while maintaining privacy, ultimately making federated learning more viable for complex, multi-institutional medical imaging tasks. Moreover, in Cyst-X , we designed our federated learning implementation to keep patient data decentralized, ensuring that raw MRI scans never leave their originating institutions. However, we did not integrate formal privacy-preserving mechanisms such as differential privacy or secure aggregation. As we move toward real-world deployment and tighter regulatory landscapes, future work should focus on incorporating these techniques to provide stronger, provable guarantees of patient privacy. For instance, differentially private federated averaging (DP-FedAvg) Geyer et al. 2017 ; Cheng et al. 2022 introduces noise to model updates to ensure individual data contributions remain indistinguishable, while secure aggregation protocols Bonawitz et al. 2017 allow encrypted model updates to be aggregated without revealing individual contributions. Our observation that certain AI-identified imaging features correlate strongly with known markers of malignancy suggests the potential for these models to identify novel biomarkers or enhance our understanding of existing ones. This aspect merits further investigation, as it may reveal imaging characteristics that are not readily apparent to human observers but hold diagnostic significance. While our findings demonstrate promise, several limitations warrant discussion. The retrospective nature of our study, though partially offset by sample size and institutional diversity, introduces potential selection biases. The evolution of MRI technology and protocols over our collection period (2004-2024) may introduce temporal variations in image quality and characteristics. Additionally, while our dataset is diverse in terms of institutional sources, further validation across different demographic populations would strengthen generalizability claims. Integrating Cyst-X into clinical practice will assist clinicians in the management of cystic pancreatic lesions in several aspects. Given the high prevalence of pancreatic cysts and the risk of missing small ones, it will serve as both a guide for detection and a decision support tool for cyst classification. More importantly, due to the complexity of pancreatic cyst management, it can directly influence patient management, such as follow-up or intervention, in more complex cases that cannot be clearly classified radiologically or clinically according to current international guidelines. However, implementing it in practice will require prospective validation studies to ensure that it performs effectively in real-world settings and user interface development to incorporate these tools into radiological workflows seamlessly. In addition, clinical trials with well-defined patient groups will further validate and improve the algorithm’s performance. Future research should also focus on combining imaging features with clinical and molecular data to improve risk stratification. In conclusion, Cyst-X represents a significant advancement in pancreatic cancer risk assessment, demonstrating the potential of AI to improve early detection of malignant transformation in pancreatic cystic lesions. By making our dataset, algorithms, and models publicly available, our objective is to accelerate research in this field and foster collaborative development that could ultimately improve outcomes for patients with this devastating disease. 4 Methods 4.1 Construction and characteristics of the Cyst-X dataset The Cyst-X dataset involves 1,461 MRI scans (723 T1W and 738 T2W) from 764 unique patients. These patients were 18 or older, collected between March 2004 and June 2024 across seven international medical centers: New York University (NYU) Langone Health, Mayo Clinic Florida (MCF), Northwestern University (NU), Allegheny Health Network (AHN), Mayo Clinic Arizona (MCA), Istanbul University Faculty of Medicine (IU), and Erasmus Medical Center (EMC). Dataset composition is summarized in Table 4 . The MRI scans were obtained from diverse imaging devices, including GE, Siemens, and Philips. The diversity of data sources enhances the robustness and generalizability of our deep learning models, reflecting the real-world clinical variations and scenarios. Each scan includes the corresponding ground truth pancreas segmentation and malignancy risk classification. Patient demographics were well-balanced across centers, with mean ages ranging from 50.9 to 71.1 years and appropriate gender distribution. To ensure consistency across institutions, we developed a rigorous inclusion protocol based on histopathological confirmation or extended imaging follow-up, which defined three categories for classification: 1. High-risk : IPMN cases with high-grade dysplasia or worse (including carcinoma in situ and invasive cancer), confirmed by EUS-guided biopsy or surgery. Only MRI scans obtained within six months of the confirmatory procedure were included. 2. Low-risk : IPMN cases with low- or intermediate-grade dysplasia confirmed histologically, or presumed low-risk IPMNs without biopsy that showed no progression over at least three years of follow-up. No progression was defined as <2.5 mm growth and absence of worrisome features or high-risk stigmata. 3. No risk / Control : Individuals with normal pancreatic imaging, no cystic lesions, or benign cysts not associated with IPMN. Table 4: Cyst-X dataset composition. Data distribution is shown hierarchically below. Data Centers NYU MCF NU AHN MCA IU EMC Imaging Device Siemens, GE Siemens, GE Siemens N/A Siemens, GE Siemens, Philips Siemens, GE MRI Magnet(T) 1.5, 3 1.5, 3 1.5, 3 N/A 1.5, 3 1.5, 1.5 1.5, 1.5 Demographics data for T1W modalities Patient Count 162 148 206 17 25 74 91 Female 98 81 109 12 14 42 43 Male 64 67 97 5 11 32 48 Mean Age(y) 63.0 65.0 63.9 N/A 71.1 64.1 50.9 Demographics data for T2W modalities Patient Count 162 143 207 27 23 73 103 Female 97 78 109 19 10 41 50 Male 65 65 98 8 13 32 53 Mean Age(y) 62.9 65.4 63.9 N/A 70.1 63.8 52.2 Figure 6: Low grade, high grade, and cancer developing IPMNs from the Cyst-X dataset. Each patient was categorized into one of these three ground truth classes: no risk/control, IPMN low-risk, or IPMN high-risk. To evaluate variability in image acquisition, we applied uniform manifold approximation and projection (UMAP) to image quality indicators, revealing distinct clustering patterns by imaging center and slice thickness. This heterogeneity reflects real-world clinical variability, enhancing the dataset’s generalizability while presenting technical challenges for model development. Fig. 6 shows examples of low-grade, high-grade, and cancer developing IPMNs from the Cyst-X dataset. In this study, diverse imaging devices and varying acquisition protocols were used to collect data. To evaluate the properties of the images, quality indicators are assessed, including statistical measures of intensity ( e.g. , mean, range, variance) and second-order statistics or filter-based metrics ( e.g. , contrast per pixel, entropy focus criterion, and signal-to-noise ratios). A total of 21 quality indicators were extracted using the open-source MRQy tool Sadri et al. 2020 . To calculate the uniform manifold approximation and projection (UMAP) for dimension reduction, each feature was normalized across the dataset using the following techniques: • MinMax normalization: x_{minmax}^{\prime}=\frac{x-x_{min}}{x_{max}-x_{min}}, (1) • Whitening normalization: x_{whiten}^{\prime}=\frac{x}{\sigma}, (2) • Z-score normalization: x_{zscore}^{\prime}=\frac{x-\mu}{\sigma}, (3) where x and x^{\prime} are the original and normalized values, respectively, while \mu and \sigma are the mean and standard deviation of the dataset. 4.2 Image preprocessing and segmentation All MRI scans were converted from DICOM to NIfTI format for processing. Then, expert radiologists manually segmented the pancreas to establish ground-truth annotations. The segmentation protocol was standardized between centers using ITK-SNAP software Yushkevich et al. 2016 , and a senior radiologist reviewed all masks to ensure quality and consistency. In this work, we adopted PanSegNet Zhang et al. 2025 for MRI pancreas segmentation, as shown in Figure 1 . By incorporating the linear self-attention structure Shen et al. 2021 into the nnUNet framework Isensee et al. 2021 , PanSegNet enhances global information modeling capabilities while maintaining linear computational efficiency Zhang and Bagci 2022 . Formally, let \mathbf{X}\in\mathbb{R}^{N\times d} denote the input feature matrix, where each row corresponds to an individual feature vector. Let \mathbf{A},\mathbf{A^{\prime}}\in\mathbb{R}^{N\times N} represent the attention matrices computed by traditional and linear self-attention mechanisms, respectively. Here, N and d represent the length and the dimension of the feature, with N>d . The queries, keys, values \mathbf{V,Q,K},\in\mathbb{R}^{N\times d} are computed by linearly projecting the input features \mathbf{X} : \displaystyle\mathbf{Q} \displaystyle=\mathbf{X}\mathbf{W}_{Q}+\mathbf{b}_{Q}, (4) \displaystyle\mathbf{K} \displaystyle=\mathbf{X}\mathbf{W}_{K}+\mathbf{b}_{K}, (5) \displaystyle\mathbf{V} \displaystyle=\mathbf{X}\mathbf{W}_{V}+\mathbf{b}_{V}, (6) where \mathbf{W}_{Q} , \mathbf{W}_{K} , \mathbf{W}_{V}\in\mathbb{R}^{d\times d} and \mathbf{b}_{Q} , \mathbf{b}_{K} , \mathbf{b}_{V}\in\mathbb{R}^{d} are learnable parameters. The traditional self-attention is defined as: \mathbf{A}_{i}=\sum_{j=0}^{N-1}sim(\mathbf{Q}_{i},\mathbf{K_{j}})\mathbf{V}_{j}, (7) where i,j index the input features, and the similarity function is defined as: sim(\mathbf{q},\mathbf{k})=SoftMax\left(\frac{\mathbf{qk}^{T}}{\sqrt{d}}\right). (8) In linear self-attention Shen et al. 2021 , the similarity function is approximated by decomposing it into two kernel feature maps: sim^{\prime}(\mathbf{q},\mathbf{k})=\phi(\mathbf{q})\rho(\mathbf{k})^{T}. (9) Here, \phi(\cdot) and \rho(\cdot) apply the SoftMax function to the queries row-wise and keys column-wise, respectively. The resulting linear self-attention is then computed as: \mathbf{A}^{\prime}_{i}=\sum_{j=0}^{N-1}\phi(\mathbf{Q}_{i})\rho(\mathbf{K}_{j})^{T}\mathbf{V}_{j}=\phi(\mathbf{Q}_{i})\sum_{j=0}^{N-1}\rho(\mathbf{K}_{j})^{T}\mathbf{V}_{j}, (10) This definition keeps the important property of original self-attention, i.e. , \sum_{j=0}^{N-1}sim(\mathbf{Q}_{i},\mathbf{K_{j}})=1 and reduces the computational complexity from O(dN^{2}) to O(d^{2}N) . Training of PanSegNet followed the implementation described in Zhang et al. 2025 . We employed stochastic gradient descent (SGD) for optimization and adopted a systematic hyperparameter tuning strategy to balance efficiency and performance. Specifically, we set the learning rate to 0.01, used a batch size of 10, and trained the model for 600 epochs. To mitigate overfitting, we incorporated dropout layers and applied data augmentation techniques during training. However, since PanSegNet is based on nnUNet, implementing it within a federated learning framework is challenging due to its reliance on centralized dataset-specific configurations and the inherent heterogeneity of federated learning setups. nnU-Net dynamically adapts its architecture, preprocessing, and training hyperparameters based on global dataset statistics, which are inaccessible in federated learning due to privacy constraints and non-IID data distribution. Furthermore, nnUNet requires its specific training commands, which complicates integration with federated learning systems. To address this issue and for comparison, we also implemented Swin-UNETR Hatamizadeh et al. 2021 . It is a widely used MRI segmentation network, and is more suitable for federated learning as it can be easily implemented using pure PyTorch Paszke et al. 2019 and MONAI Cardoso et al. 2022 . Both models were trained and evaluated using 5-fold cross-validation. 4.3 Radiologist Visual Scoring Three independent expert radiologists visually evaluated the images according to the imaging features described in the Kyoto Criteria Ohtsuka et al. 2024 . They had seven, four, and four years of experience in abdominal imaging, respectively, and they all had interpreted more than 2,000 abdominal MRIs, ensuring a high level of expertise in diagnosing and classifying complex abdominal conditions, including IPMN. The radiologists were unaware that most cysts had been confirmed as IPMNs, simulating real-life initial assessments of cystic lesions. Additionally, the radiologists were blinded to the subjects’ clinical information, relied exclusively on contrast-enhanced T1W and T2W sequences, without access to previous imaging. In this study, 67 cases from the study cohort were excluded due to the lack of appropriate T1W or T2W images, and 68 patients were also excluded for not having ground truth risk assessment labels. As a result, a total of 629 cases were used for radiologist visual scoring. A pairwise assessment of accuracy and weighted kappa statistics was conducted to evaluate agreement among the raters. Furthermore, we assessed accuracy to determine how effectively the radiologists identified high-risk lesions. 4.4 Radiomics approach for IPMN classification We extracted radiomic features that quantify the textural attributes of the entire pancreas. The preprocessing steps included reshaping, bias field correction, and intensity normalization. We conducted two separate analyses: one used the entire 3D pancreas volume to extract 763 features, while the other focused on 2D slices from the axial plane, extracting 447 features. The extracted features encompassed spatial properties of pixel intensities to capture patterns such as edges, waves, spots, and ripples. These included categories like raw intensity, gray-level, gradient, and Laws’ texture energy features Malik et al. 2001 . Additional features were derived from gray-level co-occurrence matrices (GLCM), such as Haralick features Haralick et al. 2007 and CoLlAGe features Prasanna et al. 2016 . The Haralick features captured image heterogeneity, and the CoLlAGe features Prasanna et al. 2016 identified localized gradient orientation changes. Multiple window sizes and numbers of bins were used to extract these features. Each feature was represented by four statistical metrics across the volume: median, standard deviation, skewness, and kurtosis. At the end of this process, a total of 1,788 features were extracted for the 2D analysis and 3,052 features for the 3D analysis. Then, these features were selected via the maximum relevance minimum redundancy (mRMR) algorithm Peng et al. 2005 and fed to a random forest model Ho 1995 . Finally, the random forest model determined whether the scans are IPMN high risk. The random forest model was trained with 50 iterations on the training split. 4.5 DenseNet-121 for IPMN Classification In the deep learning approach, we utilized the 3D DenseNet-121 model Huang et al. 2017 for the IPMN classification task. The ROIs in the MRI images were extracted and resized to dimensions of 96\times 96\times 96 to serve as input to the models. For model training, we employed the AdamW optimizer Loshchilov 2017 with an initial learning rate of 0.001 and a batch size of 16 over 100 epochs. The learning rate was progressively reduced by a factor of 10 every 30 epochs to enhance convergence. We implemented two versions of the DenseNet-121 model: one for three-class classification (no risk, low risk, or high risk) and another for binary classification (high risk vs. not high risk). For the three-class classification model, due to data sparsity, we used a pooled dataset approach and applied a stratified split across all images, disregarding their originating centers, to ensure a balanced representation of the categories. For the binary classification model, we adopted a multi-center dataset approach and performed a stratified split separately within each center to account for potential inter-center variability in the data distribution. Performance was evaluated using 5-fold cross-validation for the three-class model and 4-fold cross-validation for the binary model. We compared the performance of DenseNet-121 with several other prominent 3D deep neural networks, including ResNet-34 He et al. 2016 ; Hara et al. 2018 , ShuffleNet-V2 Ma et al. 2018 , MobileNet-V2 Sandler et al. 2018 , and EfficientNet-B0 Tan and Le 2019 , in the 3-class classification task. Each model was trained in two separate trials: one using T1W modality ROI images and the other using T2W modality ROI images. We also compared the predictions generated by our DenseNet-121 model with the radiologists’ assessments. Model predictions were obtained using weights from cross-validation folds corresponding to each test case, and the resulting labels were aggregated for comparison with the radiologist assessments. To further enhance model performance and clinical applicability, we explored two fusion strategies to integrate T1W and T2W information: feature-level and probability-level fusion. In the feature-level fusion approach, features extracted from T1W and T2W images were concatenated after the backbone and passed through a shared classification layer. In the probability-level fusion approach, each modality was processed through separate classification heads, and the resulting probability outputs were combined via weighted averaging. 4.6 Federated learning implementation To evaluate privacy-preserving distributed learning, we implemented both Swin-UNETR for segmentation and DenseNet-121 for classification within federated learning frameworks using FedAvg McMahan et al. 2017 and FedProx Li et al. 2020 algorithms. FedAvg aggregates model updates by averaging weights from participating clients. Formally, the update rule for the global model \mathbf{w}^{t} at epoch t is: \mathbf{w}^{t}=\frac{\sum_{k=0}^{K-1}N_{k}\mathbf{w}_{k}^{t}}{\sum_{k=0}^{K-1}N_{k}}, (11) where, \mathbf{w}_{k}^{t} is the model update from the k -th client only using data belong to it, N_{k} is the number of samples from the k -th client, and K is the number of participating clients. In contrast, FedProx introduces a proximal term \frac{\mu}{2}\|\mathbf{w}^{t+1}_{k}-\mathbf{w}^{t}\|^{2} to the loss function of each client \ell_{k} to mitigate the impact of client drift and heterogeneous data, allowing for more stable convergence: \ell_{k}^{\text{prox}}(t+1)=\ell_{k}(t+1)+\frac{\mu}{2}\|\mathbf{w}_{k}^{t+1}-\mathbf{w}^{t}\|^{2}, (12) For FedProx, we tested multiple values of the proximal term \mu (0.3, 0.1, and 0.005) to identify optimal settings. Performance was compared with centralized training using the same evaluation metrics (dice scores for segmentation; accuracy and AUC for classification). 4.7 Statistical analysis and Visual attribute maps Segmentation performance was evaluated using the dice coefficient, Jaccard index, precision, recall, 95th percentile Hausdorff distance (HD95), and average symmetric surface distance (ASSD). Classification performance was assessed through accuracy and area under the curve (AUC). Statistical significance was determined using paired t-tests or Wilcoxon signed-rank tests as appropriate, with p<0.05 considered significant. To interpret model predictions, we generated visual attribution maps using Grad-CAM Selvaraju et al. 2017 and IBA Schulz et al. 2020 ; Demir et al. 2021 . Grad-CAM highlights spatial regions that strongly influence the model’s decision by computing gradients of the target class score with respect to feature activations. In contrast, IBA offers sharper and more focused explanations by learning a perturbation mask that minimizes mutual information between intermediate representations and predictions, thereby isolating only the most critical features for decision-making. Visualizations from both methods are provided in the Supplementary Materials. 5 Data Availability The Cyst-X dataset, including anonymized MRI scans, segmentation masks, and risk labels, is publicly available at https://osf.io/74vfs/ . The dataset is provided in NIfTI format with accompanying metadata. 6 Code Availability Source code for the PanSegNet segmentation model and classification algorithms is available at https://github.com/NUBagciLab/Cyst-X . 7 Acknowledgments This work was supported by NIH NCI R01-CA246704, R01-CA240639, U01-CA268808, NIH-NHLBI R01-HL171376, and NIH-NIDDK #U01 DK127384-02S1. 8 Author Contributions H.P., Z.Z., conceived the study, performed data analysis, and drafted the manuscript. G.D., E.K., D.S., U.B. supervised the project, guided the experimental design, and critically revised the manuscript. All authors discussed the results and contributed to the final version of the manuscript. 9 Competing Interests The authors declare no competing interest. 10 Supplementary Materials (a) Pancreas Sample 1. (b) Grad-CAM. (c) IBA. (d) Pancreas Sample 2. (e) Grad-CAM. (f) IBA. Figure 7: Visual explanations using Grad-CAM and IBA. Table 5: Data Distribution for IPMN Classification. T1W Modality T2W Modality Data Centers No Risk Low Risk High Risk Total No Risk Low Risk High Risk Total Center 1: NYU 48 79 23 150 48 79 24 151 Center 2: MCF 29 42 63 134 25 42 63 130 Center 3: NU 43 126 17 186 44 127 16 187 Center 4: AHN 1 11 4 16 1 13 4 18 Center 5: MCA 0 10 14 24 0 7 16 23 Center 6: IU 3 48 13 64 3 46 14 63 Center 7: EMC 40 23 15 78 38 30 15 83 Total 164 339 149 652 159 344 152 655 Table 6: PanSegNet’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 84.99 \pm 7.74 74.56 \pm 9.84 84.80 \pm 8.66 86.10 \pm 8.32 5.96 \pm 5.31 1.26 \pm 1.19 MCF 87.47 \pm 5.79 78.17 \pm 8.37 87.63 \pm 7.44 88.11 \pm 7.37 5.35 \pm 5.68 1.07 \pm 0.94 NU 88.33 \pm 5.89 79.52 \pm 7.98 87.49 \pm 7.69 89.72 \pm 5.74 4.53 \pm 6.86 1.15 \pm 0.89 AHN 81.22 \pm 6.11 68.79 \pm 8.16 84.54 \pm 8.92 79.15 \pm 7.85 8.27 \pm 3.75 1.61 \pm 0.78 MCA 78.72 \pm 10.98 66.03 \pm 12.55 75.29 \pm 14.90 85.04 \pm 6.52 8.37 \pm 10.79 2.04 \pm 2.21 IU 85.37 \pm 9.91 75.56 \pm 12.65 86.13 \pm 9.51 85.54 \pm 11.58 8.65 \pm 16.96 1.89 \pm 2.72 EMC 89.96 \pm 4.06 81.98 \pm 6.16 89.64 \pm 5.01 90.53 \pm 4.89 5.67 \pm 21.28 1.33 \pm 2.30 Global 86.81 \pm 7.30 77.32 \pm 9.74 86.56 \pm 8.59 87.84 \pm 7.80 5.81 \pm 10.90 1.30 \pm 1.55 T2W Modality NYU 87.17 \pm 4.39 77.52 \pm 6.62 87.98 \pm 6.22 86.88 \pm 6.16 5.03 \pm 3.17 0.93 \pm 0.49 MCF 87.85 \pm 5.58 78.72 \pm 7.86 89.13 \pm 6.01 87.34 \pm 8.02 4.94 \pm 6.61 0.96 \pm 1.13 NU 92.50 \pm 5.15 86.41 \pm 7.81 92.43 \pm 5.85 92.91 \pm 5.94 2.94 \pm 3.25 0.52 \pm 0.63 AHN 82.72 \pm 9.25 71.46 \pm 11.73 86.60 \pm 11.08 80.15 \pm 9.62 7.16 \pm 6.41 1.33 \pm 1.45 MCA 84.84 \pm 3.27 73.82 \pm 4.92 87.38 \pm 5.91 83.12 \pm 6.51 6.18 \pm 3.60 0.99 \pm 0.46 IU 92.46 \pm 3.73 86.19 \pm 6.18 94.16 \pm 4.17 91.02 \pm 5.06 2.46 \pm 1.97 0.40 \pm 0.28 EMC 91.05 \pm 8.64 84.46 \pm 11.30 93.38 \pm 4.78 89.74 \pm 11.02 4.39 \pm 7.38 0.70 \pm 1.18 Global 89.62 \pm 6.38 81.73 \pm 9.31 90.74 \pm 6.45 89.11 \pm 8.06 4.19 \pm 4.99 0.75 \pm 0.87 Table 7: Swin-UNETR’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 77.78 \pm 2.40 65.26 \pm 2.51 77.48 \pm 3.78 80.72 \pm 1.68 23.76 \pm 11.55 6.93 \pm 5.58 MCF 81.63 \pm 2.92 70.17 \pm 3.51 82.97 \pm 2.06 82.05 \pm 3.48 11.27 \pm 2.84 2.68 \pm 1.71 NU 82.89 \pm 2.06 72.00 \pm 2.89 82.21 \pm 2.55 84.90 \pm 1.77 13.77 \pm 4.98 3.34 \pm 0.96 AHN 65.14 \pm 11.05 50.90 \pm 10.48 74.43 \pm 6.51 61.04 \pm 12.47 22.51 \pm 15.68 4.23 \pm 2.94 MCA 67.50 \pm 6.05 52.45 \pm 6.56 66.26 \pm 4.72 70.99 \pm 7.94 63.22 \pm 28.78 13.67 \pm 6.59 IU 79.17 \pm 2.31 67.09 \pm 3.06 78.74 \pm 3.73 81.87 \pm 3.43 30.53 \pm 6.75 8.03 \pm 2.95 EMC 74.30 \pm 2.49 61.89 \pm 3.31 73.22 \pm 5.13 79.46 \pm 2.72 72.44 \pm 48.10 24.83 \pm 19.55 Global 79.09 \pm 1.40 67.19 \pm 1.63 79.09 \pm 1.67 81.37 \pm 0.74 26.55 \pm 8.48 7.58 \pm 3.76 T2W Modality NYU 78.81 \pm 1.67 66.10 \pm 2.09 80.73 \pm 2.84 78.61 \pm 2.42 13.21 \pm 2.28 2.72 \pm 0.89 MCF 79.43 \pm 2.06 67.22 \pm 2.50 83.70 \pm 2.83 77.72 \pm 1.45 13.06 \pm 2.93 1.75 \pm 0.26 NU 81.18 \pm 1.02 69.80 \pm 1.04 81.48 \pm 0.04 82.19 \pm 1.95 17.38 \pm 3.96 4.20 \pm 1.52 AHN 64.21 \pm 6.26 50.03 \pm 6.59 72.19 \pm 8.17 64.18 \pm 9.03 31.07 \pm 13.51 8.69 \pm 5.93 MCA 59.63 \pm 4.03 44.37 \pm 3.81 63.87 \pm 5.44 61.36 \pm 9.01 81.04 \pm 22.10 24.77 \pm 8.46 IU 78.47 \pm 1.47 65.74 \pm 2.06 81.70 \pm 2.05 76.57 \pm 3.74 23.25 \pm 11.22 3.77 \pm 1.91 EMC 63.39 \pm 5.87 49.69 \pm 5.98 65.73 \pm 8.97 69.20 \pm 5.54 87.79 \pm 40.81 28.59 \pm 14.81 Global 76.29 \pm 0.66 63.77 \pm 0.82 78.70 \pm 2.14 76.86 \pm 1.21 28.53 \pm 7.01 7.57 \pm 2.60 Table 8: Swin-UNETR+FedAvg’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 71.84 \pm 2.51 58.25 \pm 2.21 71.06 \pm 3.45 76.67 \pm 1.26 34.81 \pm 8.00 12.12 \pm 6.18 MCF 77.94 \pm 3.36 65.40 \pm 3.85 79.16 \pm 3.10 79.07 \pm 3.57 15.64 \pm 3.96 3.60 \pm 1.74 NU 77.61 \pm 2.78 65.25 \pm 3.38 74.06 \pm 2.82 83.66 \pm 1.95 31.89 \pm 5.17 8.36 \pm 1.83 AHN 51.07 \pm 10.96 37.61 \pm 8.85 61.60 \pm 4.80 48.41 \pm 13.08 34.78 \pm 12.52 12.68 \pm 8.57 MCA 46.13 \pm 11.55 32.28 \pm 10.35 40.38 \pm 10.29 59.55 \pm 12.69 110.16 \pm 36.15 44.79 \pm 18.87 IU 71.09 \pm 3.26 58.03 \pm 4.01 67.60 \pm 3.86 80.11 \pm 4.29 53.95 \pm 6.37 15.16 \pm 3.77 EMC 55.67 \pm 8.40 42.23 \pm 8.18 53.61 \pm 11.02 67.57 \pm 0.69 106.46 \pm 50.34 43.83 \pm 26.68 Global 71.26 \pm 2.59 58.30 \pm 2.74 69.74 \pm 3.09 77.13 \pm 1.34 43.65 \pm 8.60 14.77 \pm 5.01 T2W Modality NYU 74.35 \pm 1.48 60.40 \pm 1.65 76.41 \pm 3.60 74.20 \pm 2.62 23.85 \pm 7.88 5.02 \pm 2.26 MCF 74.69 \pm 2.19 61.36 \pm 2.24 80.06 \pm 3.04 72.72 \pm 1.71 15.10 \pm 2.44 2.64 \pm 0.62 NU 73.99 \pm 2.16 60.71 \pm 2.15 73.26 \pm 2.12 76.54 \pm 2.20 27.46 \pm 2.41 6.97 \pm 1.70 AHN 59.41 \pm 4.71 45.24 \pm 3.78 64.31 \pm 3.14 60.20 \pm 6.89 43.94 \pm 7.98 15.80 \pm 5.17 MCA 43.20 \pm 4.86 29.99 \pm 3.94 40.48 \pm 4.54 55.05 \pm 8.71 129.24 \pm 14.32 46.21 \pm 10.93 IU 65.74 \pm 3.60 51.15 \pm 3.71 66.98 \pm 4.91 67.52 \pm 3.44 59.26 \pm 14.00 13.29 \pm 4.07 EMC 54.50 \pm 7.95 40.46 \pm 7.54 53.28 \pm 10.43 63.44 \pm 5.58 104.14 \pm 30.44 34.60 \pm 14.15 Global 69.19 \pm 1.51 55.48 \pm 1.44 70.52 \pm 2.98 71.31 \pm 0.95 41.87 \pm 5.84 11.74 \pm 3.02 Table 9: Swin-UNETR+FedProx( \mu=0.3) ’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 60.31 \pm 2.27 46.02 \pm 2.12 59.92 \pm 2.67 66.25 \pm 0.97 81.99 \pm 9.69 26.72 \pm 5.39 MCF 71.63 \pm 4.18 57.63 \pm 4.54 73.65 \pm 4.55 72.56 \pm 3.43 30.03 \pm 11.76 6.65 \pm 3.25 NU 65.07 \pm 3.77 51.06 \pm 3.74 62.81 \pm 4.73 70.57 \pm 2.54 91.69 \pm 8.79 24.60 \pm 3.51 AHN 36.24 \pm 10.71 24.91 \pm 8.01 37.94 \pm 9.71 38.25 \pm 13.66 101.79 \pm 4.39 35.16 \pm 10.74 MCA 26.91 \pm 15.07 18.28 \pm 11.69 23.06 \pm 13.27 41.17 \pm 16.93 141.22 \pm 30.07 74.43 \pm 24.62 IU 49.87 \pm 5.22 36.51 \pm 4.64 43.31 \pm 5.09 64.78 \pm 6.79 123.78 \pm 8.26 47.66 \pm 5.68 EMC 28.87 \pm 14.46 20.21 \pm 10.66 34.43 \pm 19.59 33.06 \pm 13.66 132.43 \pm 43.78 74.32 \pm 36.88 Global 57.24 \pm 3.41 44.16 \pm 2.85 56.85 \pm 4.33 62.93 \pm 2.80 87.27 \pm 8.34 31.99 \pm 6.19 T2W Modality NYU 66.32 \pm 1.57 51.23 \pm 1.45 68.43 \pm 3.06 66.90 \pm 3.30 41.34 \pm 6.78 9.66 \pm 2.52 MCF 66.00 \pm 3.16 51.19 \pm 3.06 73.18 \pm 4.34 63.36 \pm 3.00 31.08 \pm 4.63 6.04 \pm 1.30 NU 62.60 \pm 3.64 47.76 \pm 3.39 60.81 \pm 4.80 67.36 \pm 2.27 57.78 \pm 11.94 15.84 \pm 4.55 AHN 52.45 \pm 8.06 38.52 \pm 7.26 55.24 \pm 7.96 55.00 \pm 7.23 54.94 \pm 14.03 18.18 \pm 8.25 MCA 30.01 \pm 5.61 18.73 \pm 4.48 25.81 \pm 5.46 44.53 \pm 9.74 162.60 \pm 17.22 64.85 \pm 10.62 IU 52.23 \pm 2.97 38.08 \pm 3.03 50.30 \pm 3.28 58.34 \pm 3.88 90.75 \pm 7.97 27.16 \pm 3.23 EMC 37.09 \pm 11.12 25.26 \pm 8.83 35.36 \pm 12.71 46.12 \pm 10.80 138.44 \pm 27.07 55.54 \pm 20.05 Global 58.11 \pm 2.61 43.85 \pm 2.22 59.01 \pm 4.38 61.46 \pm 1.11 66.68 \pm 9.10 20.87 \pm 4.81 Table 10: Swin-UNETR+FedProx( \mu=0.01) ’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 70.16 \pm 2.67 56.32 \pm 2.50 68.93 \pm 2.96 75.42 \pm 1.94 48.86 \pm 6.08 15.39 \pm 5.71 MCF 77.56 \pm 3.35 64.78 \pm 3.86 78.55 \pm 2.42 78.98 \pm 4.17 16.27 \pm 5.43 3.90 \pm 1.93 NU 76.02 \pm 3.38 63.70 \pm 4.09 72.70 \pm 4.04 82.47 \pm 2.04 38.92 \pm 12.04 10.19 \pm 2.66 AHN 47.10 \pm 10.95 33.87 \pm 8.76 57.15 \pm 7.38 44.02 \pm 13.92 48.54 \pm 16.35 17.19 \pm 9.42 MCA 38.75 \pm 13.79 26.78 \pm 11.58 33.39 \pm 12.75 52.80 \pm 14.80 118.66 \pm 40.33 58.79 \pm 22.81 IU 67.67 \pm 3.76 54.48 \pm 4.85 64.12 \pm 4.80 77.69 \pm 4.72 70.14 \pm 9.79 21.67 \pm 4.17 EMC 50.07 \pm 12.37 37.68 \pm 11.39 47.84 \pm 14.68 61.21 \pm 7.92 119.22 \pm 48.27 55.12 \pm 31.83 Global 68.95 \pm 3.30 56.09 \pm 3.37 67.33 \pm 3.37 75.11 \pm 2.68 52.82 \pm 9.97 18.76 \pm 5.41 T2W Modality NYU 73.58 \pm 1.54 59.53 \pm 1.75 75.26 \pm 3.12 74.01 \pm 2.91 24.61 \pm 7.36 6.05 \pm 2.33 MCF 73.70 \pm 2.45 60.23 \pm 2.54 78.80 \pm 2.98 71.85 \pm 2.17 18.39 \pm 4.02 3.23 \pm 0.79 NU 72.90 \pm 2.49 59.35 \pm 2.47 71.49 \pm 1.54 76.13 \pm 3.82 31.58 \pm 4.63 8.19 \pm 1.97 AHN 57.18 \pm 7.15 43.33 \pm 5.93 65.22 \pm 8.08 59.25 \pm 10.56 53.58 \pm 13.61 16.15 \pm 7.26 MCA 39.65 \pm 4.32 26.78 \pm 3.34 35.97 \pm 4.44 52.74 \pm 7.16 143.75 \pm 17.54 53.97 \pm 13.63 IU 62.72 \pm 2.67 47.93 \pm 2.82 63.94 \pm 3.16 65.58 \pm 3.93 70.23 \pm 10.51 16.80 \pm 3.20 EMC 48.97 \pm 7.65 35.23 \pm 6.79 46.97 \pm 11.17 60.22 \pm 3.52 122.75 \pm 28.92 45.19 \pm 15.92 Global 67.25 \pm 1.86 53.47 \pm 1.77 68.22 \pm 2.99 70.23 \pm 1.21 48.36 \pm 6.51 14.52 \pm 3.64 Table 11: Swin-UNETR+FedProx( \mu=0.005) ’s performance Center Dice(%) Jaccard(%) Precision(%) Recall(%) HD95(mm) ASSD(mm) T1W Modality NYU 70.36 \pm 2.53 56.56 \pm 2.52 69.05 \pm 3.13 75.88 \pm 1.13 45.50 \pm 9.37 14.81 \pm 5.80 MCF 78.06 \pm 3.01 65.45 \pm 3.43 78.71 \pm 2.11 79.71 \pm 3.99 16.84 \pm 4.69 3.89 \pm 1.76 NU 77.12 \pm 3.06 64.79 \pm 3.77 73.90 \pm 3.36 83.19 \pm 2.12 34.39 \pm 8.18 8.86 \pm 2.00 AHN 49.40 \pm 10.96 36.07 \pm 8.83 58.90 \pm 8.21 46.13 \pm 12.58 44.40 \pm 25.11 14.65 \pm 9.00 MCA 41.21 \pm 13.62 28.85 \pm 11.78 37.23 \pm 12.92 54.25 \pm 14.72 118.45 \pm 41.69 53.98 \pm 23.47 IU 68.46 \pm 3.17 55.10 \pm 3.98 64.54 \pm 3.92 77.89 \pm 4.16 62.72 \pm 7.43 19.55 \pm 3.45 EMC 51.19 \pm 11.52 38.50 \pm 10.66 49.55 \pm 13.78 62.32 \pm 6.74 116.00 \pm 50.94 52.80 \pm 31.64 Global 69.77 \pm 2.90 56.88 \pm 2.98 68.16 \pm 2.98 75.82 \pm 2.39 49.61 \pm 8.55 17.51 \pm 5.39 T2W Modality NYU 73.95 \pm 1.71 59.96 \pm 1.95 75.27 \pm 2.96 74.70 \pm 2.76 23.38 \pm 6.26 5.50 \pm 1.87 MCF 74.07 \pm 2.93 60.69 \pm 2.97 79.08 \pm 3.05 72.32 \pm 2.92 17.86 \pm 3.41 3.12 \pm 0.79 NU 73.45 \pm 2.47 60.05 \pm 2.53 71.86 \pm 1.80 77.06 \pm 3.60 35.49 \pm 4.63 8.57 \pm 1.95 AHN 56.13 \pm 5.71 42.54 \pm 4.85 60.49 \pm 4.12 57.76 \pm 8.25 44.34 \pm 11.90 16.72 \pm 5.56 MCA 41.39 \pm 5.59 28.18 \pm 4.58 37.43 \pm 5.67 54.20 \pm 8.71 138.35 \pm 23.02 48.29 \pm 13.09 IU 63.61 \pm 1.86 49.21 \pm 2.25 65.14 \pm 2.76 65.75 \pm 3.16 69.52 \pm 11.55 16.15 \pm 2.49 EMC 50.03 \pm 8.99 36.43 \pm 8.09 48.70 \pm 11.38 61.28 \pm 4.41 123.65 \pm 25.87 43.32 \pm 15.18 Global 67.82 \pm 1.44 54.16 \pm 1.43 68.63 \pm 2.41 70.89 \pm 0.84 48.64 \pm 5.82 13.99 \pm 2.96 Table 12: Binary Classification (High Risk or Not) Results for Multi-Center IPMN MRI Using DenseNet-121. T1W Modality T2W Modality Method ACC(%) AUC(%) ACC(%) AUC(%) Center 1: New York University Langone Health (NYU) Centralized 86.65 \pm 3.37 77.09 \pm 12.25 83.50 \pm 7.70 87.54 \pm 3.89 FedAvg 81.28 \pm 4.45 68.42 \pm 13.05 87.43 \pm 2.12 90.05 \pm 4.79 FedProx ( \mu=0.1 ) 81.95 \pm 5.31 68.92 \pm 14.56 85.40 \pm 3.11 88.98 \pm 5.36 FedProx ( \mu=0.3 ) 73.19 \pm 15.91 70.19 \pm 14.82 86.79 \pm 3.14 92.67 \pm 3.60 Center 2: Mayo Clinic Florida (MCF) Centralized 65.71 \pm 8.49 74.80 \pm 13.04 72.44 \pm 12.66 81.46 \pm 10.11 FedAvg 64.95 \pm 9.86 74.31 \pm 10.05 70.79 \pm 4.94 80.85 \pm 8.25 FedProx ( \mu=0.1 ) 65.75 \pm 11.13 73.66 \pm 12.14 67.80 \pm 8.71 80.75 \pm 9.88 FedProx ( \mu=0.3 ) 65.02 \pm 13.48 74.94 \pm 13.22 63.87 \pm 10.16 81.10 \pm 6.57 Center 3: Northwestern University (NU) Centralized 84.96 \pm 5.82 67.66 \pm 10.41 82.93 \pm 9.11 57.34 \pm 16.99 FedAvg 90.33 \pm 2.36 74.66 \pm 13.61 90.89 \pm 2.43 57.94 \pm 17.95 FedProx ( \mu=0.1 ) 88.15 \pm 2.52 73.46 \pm 10.93 84.93 \pm 10.16 60.18 \pm 22.42 FedProx ( \mu=0.3 ) 88.16 \pm 2.46 73.54 \pm 14.27 89.29 \pm 2.20 58.24 \pm 27.04 Center 4: Allegheny Health Network (AHN) Centralized 87.50 \pm 12.50 66.67 \pm 40.82 67.50 \pm 19.20 70.83 \pm 29.76 FedAvg 50.00 \pm 17.68 33.33 \pm 23.57 76.25 \pm 17.81 85.42 \pm 14.88 FedProx ( \mu=0.1 ) 56.25 \pm 32.48 58.33 \pm 43.30 70.00 \pm 27.61 70.83 \pm 18.16 FedProx ( \mu=0.3 ) 56.25 \pm 36.98 58.33 \pm 36.32 88.75 \pm 11.39 79.17 \pm 21.65 Center 5: Mayo Clinic Arizona (MCA) Centralized 66.67 \pm 20.41 73.26 \pm 23.88 55.00 \pm 20.21 75.00 \pm 25.00 FedAvg 75.00 \pm 14.43 85.07 \pm 15.88 48.33 \pm 9.57 75.00 \pm 15.31 FedProx ( \mu=0.1 ) 75.00 \pm 14.43 88.19 \pm 11.85 44.17 \pm 11.40 68.75 \pm 27.24 FedProx ( \mu=0.3 ) 62.50 \pm 13.82 88.19 \pm 11.85 39.17 \pm 6.82 81.25 \pm 10.83 Center 6: Istanbul University Faculty of Medicine (IU) Centralized 78.12 \pm 6.99 64.50 \pm 24.95 79.48 \pm 4.87 83.36 \pm 11.06 FedAvg 79.69 \pm 5.18 63.02 \pm 20.20 76.35 \pm 9.00 78.79 \pm 13.25 FedProx ( \mu=0.1 ) 75.00 \pm 7.65 59.46 \pm 20.63 79.58 \pm 9.09 77.42 \pm 13.58 FedProx ( \mu=0.3 ) 70.31 \pm 19.45 62.54 \pm 16.40 77.81 \pm 2.85 79.86 \pm 11.47 Center 7: Erasmus Medical Center (EMC) Centralized 83.22 \pm 7.76 84.45 \pm 7.30 74.82 \pm 13.06 83.95 \pm 11.71 FedAvg 80.79 \pm 2.02 66.87 \pm 17.54 77.20 \pm 11.72 68.75 \pm 12.10 FedProx ( \mu=0.1 ) 79.47 \pm 3.76 83.31 \pm 15.08 77.20 \pm 6.84 81.74 \pm 16.10 FedProx ( \mu=0.3 ) 78.16 \pm 2.62 81.12 \pm 15.36 77.14 \pm 6.06 78.68 \pm 11.32 Global Centralized 79.90 \pm 1.52 78.13 \pm 2.06 78.23 \pm 5.09 82.37 \pm 1.02 FedAvg 79.29 \pm 2.04 76.19 \pm 1.02 81.08 \pm 1.69 81.24 \pm 2.98 FedProx ( \mu=0.1 ) 78.52 \pm 1.23 76.46 \pm 1.21 78.29 \pm 2.87 81.35 \pm 1.77 FedProx ( \mu=0.3 ) 75.26 \pm 4.90 76.67 \pm 1.09 79.27 \pm 2.41 81.81 \pm 2.15 Table 13: Comparison of IPMN Classification Accuracy: Radiologists vs. DenseNet-121. Input Modality Three-Class Classification Binary Classification Method T1W T2W No-Risk Low-Risk High-Risk No/Low-Risk High-Risk Radiologist 1 ✓ ✓ 89.03 58.43 64.08 89.94 64.08 Radiologist 2 ✓ ✓ 93.55 30.12 32.39 97.13 32.39 Radiologist 3 ✓ ✓ 91.61 56.33 41.55 94.66 41.55 Average ✓ ✓ 91.40 48.29 46.01 93.91 46.01 DenseNet-121 ✓ ✗ 37.42 81.02 33.80 91.38 40.85 DenseNet-121 ✗ ✓ 54.55 79.13 52.52 86.11 53.96 DenseNet-121(feature fusion) ✓ ✓ 45.16 83.13 42.96 95.69 43.66 DenseNet-121(probability fusion) ✓ ✓ 45.16 84.94 45.77 94.66 47.18