Impact of boundary conditions and geometric tolerances dynamics on MEMS double touch mode capacitance pressure sensor applying M-shaped silicon design Authors: Shabana S, Sumit Kumar Jindal Published: 2026 ABSTRACT AbstractMicro-Electro-Mechanical Systems (MEMS) are extensively utilized in many different applications because of its compact design, low power consumption and greater sensitivity. Compared to piezoresistive alternatives, a MEMS- based Touch Mode Capacitive Pressure Sensor (TMCPS) is designed and simulated to achieve better sensitivity, stability and linearity. This work presents a Double Touch Mode MEMS-based Capacitive Pressure Sensor (DTMCPS) with a flexible circular diaphragm integrated into an M-shaped silicon substrate. By increasing the diaphragm-substrate contact area, the proposed M-shaped structural arrangement improves sensor linearity and sensitivity. The diaphragms deflection characteristics are modeled using small deflection theory to minimize nonlinearity. A comprehensive analysis of the sensors capacitive behavior is carried out. The analytical formulations for capacitance, capacitive sensitivity and mechanical sensitivity are derived and generated using MATLAB based simulations. The diaphragm deformation is further assessed through structural analysis using COMSOL Multiphysics. The goal is to improve the performance of the conventional DTMCPS by integrating a silicon (Si) circular diaphragm with an M-shaped silicon substrate. The position of the touch point is crucial in defining the overall sensitivity, hence the notch size have a considerable impact on the sensors operational properties. Small deflection theory is used to model the diaphragm behavior in order to minimize nonlinear effects. These results show the potential use in cutting edge medical, automotive, aerospace and industrial sensing applications by demonstrating the higher sensitivity, accuracy and durability of the preferred TMCPS design.Keywords: MEMS pressure sensor, Capacitive sensing, M-shaped diaphragm design, Geometric optimization, Multiphysics simulationSubject terms: Engineering, Materials science Introduction MEMS stands for Micro-Electro-Mechanical systems. It is miniaturized device with the integration of mechanical micro structures like microsensors, microactuators and microelectronic devices into a single silicon substrate. MEMS technology offers several advantages like compact size, lightweight and cost effective sensor design1. The continuous evolution of MEMS technology has given rise to various innovative devices like strain gauges, gyroscopes, accelerometers, flow sensors and pressure sensors2. Recent advancements in MEMS capacitive pressure sensors have resulted in greater sensitivity, reduced power consumption and compact design. MEMS sensor offers advantages over piezoresistive sensors, especially in terms of design difficulties, modeling and simulation elements3. Silicon is a popular material for high-performance, small sensors because of its exceptional mechanical qualities and ease of micro fabrication.Its growing application in micromechanical systems is revolutionizing the creation of highly integrated sensors used for low temperature ranges4. In order to overcome the drawbacks of traditional silicon sensors, the author analyzed a unique Silicon Carbide (SiC) capacitive pressure sensor made for exceptionally demanding settings (high pressure/temperature). The simulation findings demonstrate outstanding performance with a low nonlinearity of the sensor and better stability5. In this design the material compatibility of tungsten and molybdenum with and without packaging is analyzed for MEMS capacitive pressure sensor using COMSOL simulations. The Molybdenum Tungsten design demonstrated remarkable linearity6. This work suggests a novel wing-like mechanism to greatly improve the sensitivity and responsiveness of a MEMS Capacitive Pressure Sensor (CPS). By using insulating layers that expand when pressure is applied, the mechanism successfully reduces the diaphragms deflection distance prior to contact7. The author examined a less cost straight forward utilizing Polymer Optical Fiber (POF) and intensity variation technique to alleviate the mechanical limitations of silica fiber under high pressure applications8. In order to increase the sensitivity of flexible capacitive pressure sensors, the author examines current developments with an emphasis on designs, materials and performance assessment techniques. In addition, it contrast efficient improvement methods and talks about upcoming developments for high-sensitivity applications9. Using FEA-optimized double-comb designs and corrugated edges this design has improved capacitive membrane type pressure sensor devices with high linearity10. The author examined, the non-linearity of silicon CPS featuring a single sided island diaphragm. Two linearization techniques are put forth one uses a push-pull capacitive arrangement, while the other uses output feedback to modify the excitation voltage11. A multi-step notch design quadruple touch mode capacitive pressure sensor (TMCPS) is presented in this work to improve linearity, sensitivity and robustness for industrial applications. Better capacitance behavior and diaphragm performance are shown using COMSOL and MATLAB simulation12. A capacitive pressure with a linkage film proposed in this study, has improved linearity and increases the linear response range. In comparison to traditional touch mode structures, the results demonstrate that the suggested design significantly lowers nonlinearity and doubles the linear response range13. Compared to designs with flat substrates, the suggested concave substrate Double Touch Mode Capacitive Pressure Sensor (DTMCPS) maintains higher saturation pressure and improves sensitivity. Strong industrial applications can benefit greatly from its enhanced performance which is confirmed by MATLAB simulations14. Supported by analytical modeling, MATLAB simulation and numerical analysis, a unique convex substrate square diaphragm TMCPS with improved sensitivity, extended linear operating range and superior performance for harsh-environment altimeter applications15–17. The author have designed a Double side touch mode capacitive pressure sensor(DSTMCPS). This study provide a framework for robust structure maintaining the same operational regions18.Compared to the traditional single sided design, author presents a double-sided Double Touch Mode Capacitive Pressure Sensor (DTMCPS) to improving performance of the sensor enhancing linearity, sensitivity and over range protection. The DTMCPS adds a second notch to the substrate bottom19. This work analyzes a MEMS-based Touch Mode Capacitive Pressure Sensor (TMCPS) with a conical notch substrate which enhances the touch area and capacitive sensitivity to Confirm significant improvement in sensitivity and performance over existing designs20. The W-shaped Si substrate of DTMCPS incorporated with a flexible circular diaphragm is shown, improving sensitivity, linearity and touch region21. The purpose of effectively analyses the size-dependent behavior and performance of MEMS/NEMS structures, the study emphasis the significance of advanced nonlocal and strain gradient theories22–25. The advanced nonlinear models of polymer-based capacitive MEMS sensors to improve sensitivity, stability and dynamic performance of the different dielectric materials are referred in this study26–29.A number of TMCPS designs, including concave, conical and W-shaped structures have been studied earlier.The main contribution of M-shaped silicon substrate integrated with a circular diaphragm of MEMS-based Double Touch Mode Capacitive Pressure Sensor (DTMCPS). To improve the contact area between the diaphragm and substrate during touch mode operation, a novel M-shaped silicon substrate is proposed in this work. When compared to current sensor structures, the suggested design enhances linearity, sensitivity and capacitance response.The Overview of the present work has shown in the flow diagram of Fig. 1. The present study analyse a MEMS DTMCPS that uses a silicon circular diaphragm and an M-shape substrate as shown in Fig. 2. Pressure applied between (0 to 2) MPa range, the diaphragm deflects toward the substrate when pressure is applied, finally making contact and increasing the touch area, which raises capacitance and enhances capacitive sensitivity. With MATLAB simulations, mathematical study is conducted to determine the diaphragm deflection, capacitance of linearity (C), sensitivity of capacitance (S) and mechanical sensitivity (S). In order to limit nonlinearity, the diaphragm maximum displacement is kept within one-fifth of its thickness, assuming linear elastic behaviour and small deflection of thin plate theory30. The deflection results are verified using COMSOL Multiphysics. Overview of the proposed work. Proposed work model of MEMS M shape Touch Mode Capacitive Pressure sensor design. Suggested framework MEMS sensor implementation and operating model The two dimensional cross-sectional view of the proposed MEMS based (CPS) with a flexible circular silicon diaphragm and an silicon substrate is shown in Fig. 2. The radius of the circular diaphragm is and the entire sensor structure substrate is . To provide electrical isolation and avoid short circuiting when the diaphragm comes into contact with the substrate during touch mode, a thin insulation layer of insulation is applied to the substrate represents as h.The depth of the M-shape notch that forms on the substrate surface is indicated by , whereas the y indicates the initial gap between the diaphragms top surface and substrate. t indicates the thickness of diaphragm which controls its pressure sensitivity and mechanical rigidity. The diaphragm maintains its initial position in the Normal Mode as shown in the Fig. 3, with a consistent air gap between diaphragm and the substrate. There is not enough pressure to make contact within the parallel plate capacitance region. Showing the Circular Diaphragm of MEMS Touch Mode Capacitive Pressure Sensor under Normal Mode operation. Analyzing the proposed sensor behavior in single touch mode In Single Touch Mode the diaphragm deflects when the applied pressure rises and eventually makes contact with the M-shape notch central peak as shown in the Fig. 4. Due to deformation, the air gap is reduced close to the central contact causing the capacitance to starts increase linearly. Single Touch Mode operation of Proposed MEMS Capacitive Pressure Sensor shows diaphragm deformation and initial contact with the M-shaped substrate central peak when pressure is applied. Behavioral study of the proposed sensor in double touch mode The diaphragm deflects to its greatest extent at high pressure, making contact with the M-shaped notch as well as the flat surface substrate to create the Double Touch Mode as shown in the Fig. 5 for sensor determine the boundary conditions for calculating the capacitance value, this M-shape model takes into account important features such as the diaphragm deflection, touch and untouched regions. y denoted as the distance between the top of the diaphragm and the flat substrate. whereas, represents the height of the M-shaped notch on the substrate. R represents the radius of the circular diaphragm. Both and are the touch regions. , and are the untouched regions as shown in Fig. 5. Taking into account these touch and untouched areas the boundary criteria is determined. Suggested M-shaped Double Touch Mode Capacitive Pressure Sensor(DTMCPS) operation shows diaphragm deformation, touch and untouched regions and essential geometric characteristics for capacitance analysis under the applied pressure. Analytical approach to capacitance vs pressure in double touch mode The initial research focuses on the deformation of a circular diaphragm under uniform pressure according to the working principle of parallel plate capacitance. Compared to rectangular, square diaphragms and circular diaphragms are chosen because of their even stress distribution and lower stress concentration. The below expression for the deflection w(r) is given by21. where P stands for applied pressure, R is the radius of the diaphragm, r is the Gaussian point between (0 to r) and D flexural rigidity21. where ν stands for Poisson’s ratio, h is the thickness of the diaphragm and E for Young’s modulus. The flexural rigidity is given by, Determine the boundary conditions based on deflection mode of operation The circular diaphragm deformation occurs due to applied pressure as shown in Fig. 5. The diaphragm deflection on M-shape in the touch mode operation is determined by Here denotes the Gaussian points within the range (0 to ).The diaphragm deformation occurs due to applied pressure as shown in Fig. 5. In the double touch mode, the deflection on the flat surface and M-shaped notch is provided by, Here represents gaussian points within the range 0 to R. Mathematical analysis of double touch mode function In double touch mode, diaphragm is in contact with both the notched areas of the M-shaped and the flat substrate shown in Fig. 5, the capacitance values corresponding to the touched and untouched areas of the diaphragm are calculated using the deflection equation (3) and equation (4). The parallel plate capacitance principle and small deflection plate theory30 are the foundation to determine the Boundary conditions and capacitance values assume in equation (3) (4) and (5). The double touch mode operation of the proposed sensor structure separates the diaphragm deformation into touch and untouched regions are calculated Using the Gauss numerical integration method30, the Double Touch mode can be computed from equation (5), where represents the air dielectric constant, is the insulating material of the dielectric constant and is the relative permittivity of the dielectric material. Thus, the total capacitance for touch and untouched regions will be written as, Where, and are the touch regions of M-shape notch and on the substrate respectively, , and are the untouched area of notch and substrate respectively. From equation (3), We can apply the value of We get as, Then consider , Apply from equation (3), ,Where k<2 Let, Assuming, Let the , Assume, Therefore, applying limit 0 to 1 and using above equations, can be written as Solving we get, Now for touch region , From equation (4), we can apply the value of =y,we get Similarly for untouch mode for , Therefore We considered, On solving we get, Values of k1’,k2’, Solving we get, Similarly for , Total Capacitance value of is, Variation of diaphragm deflection with applied pressure The theoretical models acquired through the derivations above yield results that have been anlayzed using MATLAB. In Fig. 6, throughout the entire operating pressure range of (0–2) MPa, the maximum diaphragm deflection of 1.8 μm is stayed below one-fifth of the diaphragm thickness, confirming the small deflection theory and linear elastic assumption used in this work. To further verify the applicability of the proposed analytical model, a plot of deflection ratio versus applied pressure has shown clearly. Deflection of diaphragm in MATLAB as a function of pressure. Capacitance obtained in MATLAB After considering the above equation (30), the relationship between applied pressure and resulting capacitance variation will be more accurately characterized. MATLAB will be used to simulate the overall capacitance value as shown in the Fig. 7. As the distance between the movable diaphragm and fixed bottom of the substrate consistently decreases during touch mode operation, the diaphragm deformation permits a constant and smooth fluctuation in capacitance. In normal mode conditions, a capacitance of nearly 1.5 pf is equivalent to an applied pressure of 0.4 MPa as shown in Fig. 7. The sensor in touch mode, which causes increase in capacitance, when the applied pressure increases the diaphragm to make contact with the bottom electrode. Due to the increased contact surface and reduced gap between the electrodes, this mode effectively increases the sensitivity of the sensor, even if small changes in pressure cause changes in capacitance. Beyond an applied pressure of around 1.8 MPa, the capacitance begins to approach saturation point, reaching a maximum value of 19.9 pf at 2 MPa.The diaphragm is completely in contact with the bottom electrode which leads to the saturation behavior of sensor. Capacitance in MATLAB as a function of pressure. Evolution and analysis of capacitance sensitivity (S) The term “capacitance sensitivity” (S) describes how much capacitance changes in response to changes in the applied physical pressure. Capacitance sensitivity can be mathematically expressed as where the applied pressure is represented by P and the capacitance by C. Improved sensor response and performance are indicated by a higher sensitivity value which shows a larger change in capacitance for a given input variation. The accuracy, linearity and operational efficiency of MEMS-based touch mode capacitive pressure sensors (TMCPS) are all greatly influenced by capacitance sensitivity. Capacitance sensitivity obtained in MATLAB The MATLAB design of the capacitance sensitivity behavior M-shape is given as shown in Fig. 8. High capacitive sensitivity is a sign of better sensor performance in detecting even the smallest changes in the parameter (S) causes large changes in capacitance. As pressure increases, the diaphragm contact area grows. Which decreases the rate at which capacitance varies in response to pressure and reduces overall sensitivity. Fig. 8 shows the near linear region, where capacitance variation is minimal, the sensitivity gradually decreases and approaches zero in the saturation region. The sensors minimum detectable pressure change, defined by its resolution, is calculated to be 3.25 Pa. This value confirms the sensor highly effective sensitivity and its effectiveness in detecting extremely small pressure variations making it highly suitable for precision-oriented applications. MATLAB as a function of Capacitance Sensitivity. Evolution and analysis of mechanical sensitivity The ratio of the mechanical deflection of the diaphragm to the corresponding applied external pressure is known as mechanical sensitivity . It is crucial metric for assessing the deformation behavior and pressure responsiveness of MEMS-based devices. It describes the structural reaction of a sensor to mechanical loading. It can be mathematically expressed as Mechanical Sensitivity, Mechanical sensitivity vs diaphragm thickness obtained in MATLAB The connection between diaphragm thickness and mechanical sensitivity is seen in Fig. 9. The findings show that mechanical sensitivity decreases in proportion to an increase in diaphragm thickness. This behavior is explained by the fact that bigger part diaphragms deflect less when pressure is applied. Additionally, the curve shows a sharp decrease in mechanical sensitivity when the diaphragm thickness surpasses 10 , indicating the substantial impact of structural rigidity on sensor performance. MATLAB as a function of Mechanical Sensitivity. Diaphragm deflection for proposed model The mechanical sensitivity of the suggested sensor is determined by the diaphragm’s deflection profile. The simulated diaphragm deflection at an applied pressure of 2 MPa is shown in Fig. 10, and the deflection magnitude derived from MATLAB analysis is shown According to the findings, the diaphragms center experiences the greatest deflection, which progressively goes down towards the clamped borders before becoming insignificant. The displacement was determined at each simulation step using a pressure increments of 0.1 MPa within the operating range of (0–2) MPa. MATLAB as a function of Central deflection. Extraction through COMSOL design The results of the COMSOL Multiphysics simulation of the suggested MEMS-based pressure sensor construction. The meshing displacement profile and stress distribution of the sensor diaphragm under pressure circumstances are all included in the analysis. This view shows the sensor model of finite element meshing, in which the structure is divided into many tiny tetrahedral elements. The mesh guarantees precise numerical calculation of the electrical and mechanical properties. with the diaphragm center where maximal deflection takes place, showing the highest stress in Fig. 11. A maximum central deflection of 1.67 was anticipated by the COMSOL Multiphysics simulation which nearly matched the 1.8 value that was determined analytically using equation (1). The assumption of modest deflection is validated because this deflection is less than one-fifth of the diaphragm thickness. Results of COMSOL (a) Mesh view (b) Stress View (a) COMSOL proposed work sensor design under deformation. When pressure is applied, the diaphragm deflects in this mode and makes contact with the substrate in a single central area of M-shape. As the effective gap between the diaphragm and the substrate decreases, the capacitance changes. The diaphragm receives more deflection when pressure is applied more, touching the substrate at two different contact zones on substrate. This double-touch behavior introduces several capacitance zones, one for each contact zone, which improves the pressure sensors overall performance by increasing the detecting range and linearity as shown in the Fig. 12. Results of COMSOL (d) Single touch mode deformation behavior of TMCPS (e) Double touch mode deformation behavior of TMCPS (f) Cross sectional views. The start of double touch behavior is confirmed by the stress concentration which is mostly seen close to the diaphragm substrate contact regions. The effective conversion of applied pressure into diaphragm displacement is shown by the deformation pattern ensuring improved capacitive response Fig. 13. Results of COMSOL (g, h and i)DTMCPS M-shape Model deformation under different views. Proposed model research design specifications The two-dimensional design of the capacitive pressure sensor (CPS), which uses a silicon (Si) substrate with 420 × 420 dimensions, is shown in Fig. 2. The sensing gap is isolated by the 0.5 thick insulating silicon dioxide layer. A 200 radius circular diaphragm is positioned above the substrate and deforms when pressure is applied. While is the distance from the substrate surface to the apex of the M-shaped notch, which represents the structural height, y is the distance between the diaphragm and the substrate plane surface. Table 1 provides a summary of the relevant design parameters. Table 1Proposed Model sensor specifications as considered.ParameterDesign ValuesYoung’s Modulus of Silicon(E)Thickness of the diaphragm (t)Silicon Poisson’s ratio (ν)0.28Radius of the diaphragm(R)Pressure range for Normal mode0–0.4 MPaPressure range for Touch mode0.4–1.8 MPaSiO dielectric constant ()3.9Dielectric constant of air ()1Dielectric constant of Silicon ()11.7Radius of the M-shape notch ()Insulation layer thickness (h)Distance between the diaphragm and substrate (y)Distance between the diaphragm and M-shape notch () Proposed Model sensor specifications as considered. Comparison of results with existing literature When compared to conventional designs, the symmetric M-shaped design helps in maintaining uniform pressure distribution. During double touch mode operation, the effective diaphragm–substrate contact area is increased by introducing the M-shaped structure on the substrate. The M-shaped notch improves capacitance response, sensitivity and linearity by increasing the effective touch area.The simulation results of MATLAB and COMSOL Multiphysics are thoroughly discussed and compared in the sections that follows the below mentioned. A comparison of several sensor designs is shown in Table 2, together with information on their respective sizes and capacitance values (in pF) at 1.5 and 2 MPa applied pressures. The capacitance measurements have been used to evaluate the sensitivity of each type of sensor. The results indicate that in comparison with previously published designs the suggested sensor structure shows an apparent rise in sensitivity. In particular, the M-shaped substrate TMCPS integrated with a circular diaphragm shows enhanced capacitance performance over the whole working pressure range of 0–2 MPa in comparison to previous studies compiled in Table 2 as well as shown in comparison chart of proposed design in Fig. 14. Table 2Comparison performance parameters with literature and proposed work improvements.Type of SensorSubstrate and DiaphragmSize ()/Comment on SensitivityCapacitance(pF) at 1.5 MPaCapacitance(pF) at 2 MPaRemarksSTM-CPS14Concave well and circular diaphragmh = 5, R = 180, y = 23.94.5–STM-CPS31Fixed Electrode and circular diaphragmh = 5, R = 180, y = 2, and 9.19.8–DTM-CPS21W-Shape structure with circular diaphragmh = 15, R = 180, y = 1, and 14.114.7–Proposed workM-shape substrate and circular diaphragmh = 10, R = 200, y = 2, and 19.319.9Improved sensitivity performance in proposed design Comparison performance parameters with literature and proposed work improvements. Comparison of MATLAB and COMSOL for proposed work. Simulation analysis and result outcomes discussion The analytical models which included diaphragm deflection equation (1), double-touch mode capacitive pressure sensor (DTMCPS) characteristics equation (5), and capacitive sensitivity equation (31), were developed and solved using MATLAB. equation (32) was also used to analyses the mechanical sensitivity in order to evaluate the overall performance of the sensor as shown in Fig. 15. To maintain reproducibility, Table 1 summaries the key simulation parameters such as material properties and geometric configurations. The circular diaphragm, substrate and insulating layers for the three-dimensional model were built using the dimensions listed in it. The diaphragm and substrate were made of silicon (Si), and the insulating layer was made of silicon dioxide . The diaphragm’s mechanical response was simulated using the solid mechanics under the structural mechanics module. To replicate clamped support, fixed boundary conditions were applied along the edges. The diaphragm surface was subjected to pressure loads ranging from (0 to 2) MPa in order to assess its deflection behavior. In order to ensure numerical stability and accuracy, a tetrahedral meshing method was chosen and appropriate linear solvers were put into place to account for minor deformations. This method made it possible to thoroughly examine the operating properties of the sensor as shown in the Figs. 11, 12, 13 respectively.The MEMS sensor subjected to determined the fixed boundary conditions to simulate the clamped support utilized in MEMS TMCPS.As the maximum diaphragm deflection maintained under one-fifth of the diaphragm thickness, ensuring linear behavior of small deflection theory is applied.Maintaining the small deflection theory ensures linear sensor behavior, resulting in accurate, reliable, low-stress and impactful pressure sensor performance in real-world applications (Fig. 16). Simulation and Analytical results of MATLAB (a) Capacitance change with applied pressure (b) Capacitance sensitivity with pressure (c) Mechanical sensitivity versus diaphragm thickness (d) 3D diaphragm deflection (e) Comparison of diaphragm deflection from MATLAB and COMSOL simulations. Comparison of existing and proposed work. Conclusion The Proposed M-shaped Double Touch Mode Capacitive Pressure Sensor (DTMCPS) increases linearity, sensitivity and capacitance response over the pressure range of (0–2) MPa which improves the diaphragm substrate contact area.The suggested structure circular diaphragm design is responsible for a noticeable increase in sensitivity. This structure significantly achieves a maximum capacitance of 19.9 pf, a sensitivity of 1.63 and a resolution of 3.25 Pa throughout a pressure range of (0–2) MPa. Consistency with small deflection theory is confirmed by the greatest central deflection of 1.81 from COMSOL, which closely matches MATLAB estimates of 1.62 . Both values stay below one-fifth of the diaphragm thickness. COMSOL simulations are used to validate the theoretical model. Due to its improved structural stability, the M-shaped design performs better than other geometrical configurations. The improved performance of the circular diaphragm is confirmed by both analytical and simulated results, which emphasize its enhanced sensitivity, better capacitance response and strengthened structural robustness. Future research will concentrate on temperature impacts, residual stress reduction. Supplementary Information Supplementary Information. Acknowledgements We thank the Management of Vellore Institute of Technology, Vellore, India, for providing the opportunity, facilities and continuous support to carry out this research work. Author contributions All authors contributed to the study conception and design. The manuscript first draft was written by Ms. Shabana S and it was examined and recommended by Dr. Sumit Kumar Jindal. The final draft of the work was read, edited and approved by all of the authors. Funding Open access funding provided by Vellore Institute of Technology. Data availability All data generated or analysed during this study are included in this published article “Bi, G.R., Jindal, S.K. & Sahoo, S.P. Investigation into electro mechanical behaviour of MEMS wing shaped dielectric capacitive pressure sensor conforming to set boundary conditions and sizing tolerances. Sci Rep 15, 24187 (2025). https://doi.org/10.1038/s41598-025-08654-3” [and its supplementary information files as attached]. Declarations Competing interests The authors declare no competing interests. Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Supplementary Information The online version contains supplementary material available at https://doi.org/10.1038/s41598-026-54983-2. References Associated Data Supplementary Materials Supplementary Information. Data Availability Statement All data generated or analysed during this study are included in this published article “Bi, G.R., Jindal, S.K. & Sahoo, S.P. Investigation into electro mechanical behaviour of MEMS wing shaped dielectric capacitive pressure sensor conforming to set boundary conditions and sizing tolerances. Sci Rep 15, 24187 (2025). https://doi.org/10.1038/s41598-025-08654-3” [and its supplementary information files as attached].