Kinetics, mechanistic, toxicological and economical investigations of para-chlorophenol degradation by UV/persulfate and UV/persulfate/Fe2+ processes Authors: Tayyeba Ali, Talha Sharif, Shabir Ahmad, Sumaira Wilayat, Muhammad Ateeq, Javed Ali Khan, Hazratullah Paktin Published: 2026 ABSTRACT Para-chlorophenol (4-chlorophenol, 4-CP) is a member of the toxic chlorinated phenolic compounds. It is broadly used in preservatives, and as a precursor for some herbicides and fungicides and has been detected in natural aquatic environments. This work examined the photochemical degradation of 4-CP by ultraviolet light (UV), UV/persulfate (UV/PS) and UV/persulfate/Fe2+ (UV/PS/Fe2+) methods. Under UV light irradiation (UV-C, 254 nm), the removal efficiency of 4-CP (20 mg/L) was 44.7, 58.8 and 66.8% at pH 3, 6 and 11, respectively, after 25 min of irradiation. The addition of 0.5 mM PS to UV enhanced the removal efficiency of 4-CP to 90.2% (at pH 3) and 100% (at pH 6 and 11), at the same treatment time. However, complete removal of 4-CP occurs in UV/persulfate/Fe2+ process, employing Fe2+ = 0.3 mg/L, PS = 0.5 mM and 4-CP = 20 mg/L, at pH 3, after 25 min of treatment. Additionally, the degradation efficacy was adversely affected by humic acid (HA) and inorganic ions. Similarly, the TOC removal was 65.8 and 86.1%, for UV/PS and UV/persulfate/Fe2+ techniques, after 120 min. Moreover, the contribution of SO4•− and HO• was investigated by scavenging study. Additionally, GC-MS was used to detect the degradation products (DPs) of 4-CP. Finally, ECOSAR program was used to evaluate the toxicity of 4-CP and its DPs. Nonetheless, the present study suggests that UV/PS and UV/persulfate/Fe2+ techniques can effectively eliminate chlorophenols from aquatic environments.Graphical Abstract Introduction Industrialization and urbanization are essential for the modern world. The use of several forms of energy for industrialization leads in the disposal of a considerable amount of waste into the environment. This causes various issues with public health, as well as greenhouse gas emissions and water pollution [1, 2]. Water pollution has become a serious issue as a result of large amounts of domestic sewages and industrial wastes being released into the water bodies [3, 4]. Wastewater coming from various industries such as pesticide, pharmaceuticals, and petrochemical processing includes huge amounts of organic compounds like aromatic compounds, chlorinated hydrocarbons, textile dyes, and phenolic compounds [5]. Chlorophenols, a class of phenolic compounds, had been categorized as priority hazardous contaminants by the United States Environmental Protection Agency and the European Commission Decision 2455/2001/EC [6, 7]. They are widely used for a variety of purposes, including preservatives (in paint, wood and dye industries) and as precursors in several fungicides, herbicides and dyes [8]. A starting precursor for the synthesis of 2-benzyl-4-chlorophenol germicides is 4-chlorophenol. It is also utilized in the manufacturing of analgesics containing acetophenetidin. The main application for 2,4-DCP is the synthesis of 4-dichlorophenoxy acetic acid, a common pesticide that is widely utilized in agricultural production [9]. These are the building blocks for extremely hazardous chemicals known as polychlorodibenzofurans and polychlorophenoxyphenols [9]. It is widely used in the production of antibacterial and other anti-helminthic medications, including triclosan [10]. Chlorophenols (CPs) are characterized as resistant and hardly biodegradable, that represent a threat to environmental integrity and human health [11]. 4-CP, a toxic chlorinated organic pollutant, continually enters to the environment, producing severe pollution and devastation [12, 13]. They have received a great deal of interest due to their toxic nature for living organisms and potential to accumulate biologically in humans as well as animals [14]. Even at low concentrations of 4-CP (3–4 mg/L), results in DNA damage, bioaccumulation, and mortality in aquatic animals [15]. The presence of 4-CP in the aquatic system at concentrations ranging from 0.005 to 20 µg/L has a chronic effect on humans [16]. Therefore, it is necessary to treat 4-CP contaminated wastewater to protect the environment from its negative effects [17]. A variety of traditional techniques are used for the elimination of chlorophenols from wastewater, including the coagulation, activated sludge process, precipitation, ion exchange, membrane filtration, and biological treatment. These traditional methods are proficient in reducing wastewater with high concentrations of organic chemicals; however, they prove inadequate for wastewater at lower pollutants concentrations. While each conventional technique possesses its own merits and drawbacks, a significant disadvantage is the generation of secondary pollutants. Thus, advance oxidation procedures arise as efficient methods for the elimination of organic contaminants from wastewater [18, 19]. Advanced oxidation processes (AOPs) are highly effective methods which can degrade organic compounds [20]. AOPs employ highly reactive oxidizing agents including hydroxyl radicals (HO•) and sulfate radicals (SO4•−) to eradicate organic contaminants from aquatic environments [21]. They are distinguished by their ease of implementation, high efficiency, environmental compatibility, and ability to oxidize a wide range of pollutants. Moreover, they have been frequently used in the degradation of refractory contaminant [22]. AOPs based on sulphate radicals or hydroxyl radicals have been demonstrated in studies for effective degradation of organic pollutants [23–29]. However, hydroxyl-radical based AOPs may be limited by their short half-life (< 1 µs). There has been increasing interest in sulfate radical-based AOPs due to an increasing variety of applications documented in the literature. SO4•− offers numerous distinct advantages, including a greater redox potential (E0 = 2.5 to 3.1 V versus standard hydrogen electrode (SHE)), an expanded working pH range (2 − 8), and a considerably extended half-life (30 to 40 µs) compared to HO• [30, 31]. Therefore, for the treatment of contaminated water, SR-AOPs are regarded to be the most promising advanced oxidation process [32]. The primary goal of this work was to explore the efficacy of sulphate radical-based advanced oxidation procedures, such as UV, UV/PS, and photo-Fenton like techniques, for the removal of 4-CP. The impact of initial 4-CP, PS, and Ferrous ion concentrations have been studied. Experiments at various pH levels were also carried out in order to determine the optimum pH for 4-CP removal. Moreover, the impact of inorganic ions on removal of 4-CP was studied. Additionally, GC–MS was used to identify the degradation products (DPs) of 4-CP. Finally, the toxicity of DPs was assessed by ECOSAR program. Experimental Chemicals and reagents 4-Chlorophenol, sodium persulfate (Na2S2O8), HCl and NaOH were supplied by Sigma-Aldrich, Darmstadt, Germany. Ferrous sulfate (FeSO4.7H2O), methanol, Tertiary-butyl alcohol (t-BuOH), NaHCO3, Na2CO3, NaCl, and humic acid (HA) were purchased from Merck, Darmstadt, Germany. All reagents and compounds were of analytical grade and utilized without further purification. Experimental procedures An aqueous solution with a 100 mg/L was prepared by mixing an appropriate amount of 4-CP with distilled water. The reactions were conducted at ambient temperature. The pH of the solution was adjusted/maintained using either 1 M HCl or 1 M NaOH. The source of irradiation was a 35-watt Philips, Holland-made UV-C lamp (254 nm). After a certain period of time, the samples were taken for quantification of 4-CP. Analytical methods High performance liquid chromatography (Agilent 1100 series) was used for quantification of 4-chlorophenol, detector wavelength set at 280 nm. The detail of the procedure is given somewhere else [33]. The DPs were determined by analyzing the irradiated samples using gas chromatography-mass spectrometer (GC Agilent-8890, MS Agilent-5977). The procedure is described in detail by Iqbal et al. [34]. The Shimadzu VCSH-ASI TOC analyzer was employed to quantify the total organic carbon (TOC). The TOC analysis was conducted using a 20 mL sample volume. 4-CP degradation efficacy was assessed through Eq. (1):1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\%}\:\mathrm{R}\mathrm{e}\mathrm{m}\mathrm{o}\mathrm{v}\mathrm{a}\mathrm{l}\:=\frac{({\mathrm{C}}_{0}-{\mathrm{C}}_{\mathrm{t}})}{{\mathrm{C}}_{0}}\:\times\:\:100\:$$\end{document} In Eq. (1), C0 denotes the starting concentration of 4-chlorophenol, while Ct indicates the concentration of 4-chlorophenol at any irradiation time t. Toxicity assessment The toxicity of 4-CP and its DPs was assessed using the ECOSAR software. This is an appealing program utilized for assessing the chronic and acute toxicity of chemical substances. The acute toxicities were evaluated in terms of LC50 and EC50 values of 4-CP and its DPs [21]. Result and discussion Direct photolysis of 4-chlorophenol The photolysis of water generates hydroxyl radicals and hydrated electrons specifically at wavelengths below 190 nm [21]. Therefore, any 4-CP deterioration at 254 nm (UV-C light) is attributed to the creation of an excited state of 4-CP molecules (4-CP*), when a photon is absorbed at 254 nm (reaction (2)).2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{4}} - {\text{Chlorophenol }}+ hv \rightarrow~{\mathrm{4}} - {\mathrm{Chlorophenol}}*$$\end{document} When the molecules are excited, they can either break down directly (reaction (4)) or they can cause the creation of reactive oxygen species (reaction (5)), which subsequently attack the 4-CP molecules which results in its removal (reaction (6)) [35].3\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{4}} - {\mathrm{Chlorophenol}}* \rightarrow~{\mathrm{4}} - {\mathrm{Chlorophenol}}$$\end{document}4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{4}} - {\mathrm{Chlorophenol}}* \rightarrow~{\text{Degradation products}}$$\end{document}5\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{4}} - {\mathrm{Chlorophenol}}*{\text{ }}{+^{\mathrm{3}}}{{\mathrm{O}}_{\mathrm{2}}} \to {\text{ 4}} - {\mathrm{Chlorophenol}}\,+{\,^{\mathrm{1}}}{{\mathrm{O}}_{\mathrm{2}}}$$\end{document}6\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{4}} - {\mathrm{Chlorophenol}}\,+{\,^{\mathrm{1}}}{{\mathrm{O}}_{\mathrm{2}}} \to {\text{ Degradation products}}$$\end{document} In the present study, a series of experiments were performed at pH 3, 6 and 11 employing [4-CP]0 = 20 mg/L (Fig. 1). The removal efficacy of 4-CP was found to be 63.8, 71.8 and 83.4%, after 45 min of irradiation. Similarly, the kobs was 0.0303, 0.0435 and 0.0549 min− 1, respectively, at pH 3, 6 and 11. The increase in degradation of 4-CP at alkaline pH is due to the efficient absorption of UV light in its anionic state [36]. Fig. 1Influence of pH on degradation of 4-chlorophenol by UV (UV-C, 254 nm and 35 W) only. Experimental condition: [4-CP]0 = 20 mg/L Influence of pH on degradation of 4-chlorophenol by UV (UV-C, 254 nm and 35 W) only. Experimental condition: [4-CP]0 = 20 mg/L Removal of 4-CP by UV/persulfate and UV/persulfate/Fe2+ techniques Impact of PS The PS dosage plays a substantial role for the formation of SO4•− and the subsequent degradation of 4-chlorophenol. To ascertain the role of PS in 4-chorophenol degradation using UV/PS process, various dosages of PS ranging from 0.2 to 1 mM were investigated at pH 6.0, keeping the [4-CP]0 constant at 20 mg/L. The degradation efficacy of 4-CP linearly increases with rise in PS concentration. The degradation of 4-CP was found to be 89.8% using 0.2 mM PS. Similarly, complete removal of 4-CP occurs employing 0.5 and 1 mM PS, after 25 min of irradiation (Fig. 2a). However, the kobs was 0.0669, 0.0876 and 0.1265 min− 1, for 0.2, 0.5 and 1 mM PS, accordingly. As the concentration of PS rises, more sulfate and hydroxyl radicals were produced, which causes 4-CP to degrade more quickly (reactions (7) and (8)) [14].7\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${{\mathrm{S}}_{\mathrm{2}}}{{\mathrm{O}}_{\mathrm{8}}}^{{{\mathrm{2}} - }}+hv \to {\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}$$\end{document}8\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ }}{{\mathrm{H}}_{\mathrm{2}}}{\text{O }} \to {\text{ H}}{{\mathrm{O}}^ \bullet }+{\text{ }}{{\mathrm{H}}^+}+{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}} - }}$$\end{document} However, in photo-Fenton like process, the same starting concentration of PS was used as in UV/persulfate technique, such as 0.2, 0.5, and 1 mM. The % degradation of 4-CP was 95.8% using 0.2 mM PS, employing 4-CP = 20 mg/L, Fe2+ = 0.3 mg/L at pH 3, after 25 min. However, complete removal of 4-CP occurs at 0.5 and 1 mM PS, using fixed other experimental conditions (Fig. 2b). However, the kobs was 0.0891, 0.113, 0.1354 min− 1 for 0.2, 0.5, and 1 mM PS, accordingly. Additionally, SO4•− are produced through reaction (9), in addition to reaction (7), in the UV/PS/Fe2+ process, which results in the increased breakdown of 4-CP [37, 38]. Similarly, The efficacy of UV/PS/Fe2+ is greater at pH 3, as neutral and basic conditions lead to the precipitation of Fe2+ as ferric oxyhydroxide [39]. The enhancement in 4-CP removal in UV/PS/Fe2+ is because of dual activation of PS by both UV and Fe2+, compared to UV only in UV/PS process.9\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{F}}{{\mathrm{e}}^{{\mathrm{2}}+}}+{\text{ }}{{\mathrm{S}}_{\mathrm{2}}}{{\mathrm{O}}_{\mathrm{8}}}^{{{\mathrm{2}} - }} \rightarrow~{\mathrm{F}}{{\mathrm{e}}^{{\mathrm{3}}+}}+{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}} - }}$$\end{document} Fig. 2Influence of PS on removal efficiency of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b) techniques. Experimental conditions: [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L, pH = 6 (UV/persulfate) and 3 (UV/PS/Fe2+) Influence of PS on removal efficiency of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b) techniques. Experimental conditions: [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L, pH = 6 (UV/persulfate) and 3 (UV/PS/Fe2+) Impact of [4-CP]0 It is particularly crucial to explore how different initial concentrations of target contaminant affect the efficacy of a water treatment technology in eliminating them, as these contaminants vary in concentration in natural water. It will contribute to the development of viable water treatment technology for naturally contaminated water under a variety of conditions [21]. Therefore, the influence of initial 4-CP concentration on the removal efficacy of 4-CP by UV/PS and photo-Fenton like techniques were determined by conducting a series of experiments. In UV/PS process, the degradation efficiency was 100% for 10 and 20 mg/L 4-CP, while 86.5% for 30 mg/L 4-CP, respectively, using PS = 0.5 mM and pH = 6, after 25 min of irradiation (Fig. 3a). The pseudo-first-order rate constant (kobs) was 0.1215, 0.0876, and 0.0617 min− 1 at [4-CP]0 = 10, 20, and 30 mg/L, accordingly. However, in photo-Fenton like process, the effect of same starting concentration of 4-CP was evaluated as in UV/PS process i.e., 10, 20, and 30 mg/L (Fig. 3b). The degradation efficiency of 4-CP was 100% for 10 and 20 mg/L. However, the percent removal of 4-CP was 92.7% for 30 mg/L, after 25 min of reaction time. The other experimental conditions were kept constant at PS = 0.5 mM and pH = 3. The kobs for 10, 20 and 30 mg/L of 4-CP was 0.1645, 0.113 and 0.0704 min− 1, respectively. Since both of these processes rely on SO4•−, the decrease in 4-CP degradation with increasing 4-CP concentrations can be explained by the same reasons. Furthermore, the concentration of degradation products increases with the rising concentration of 4-CP; hence, SO4•− is likely to interact with degradation products instead of 4-CP, resulting in decline in degradation efficiency of 4-CP. The removal rate increases with rise in 4-CP concentration. As the concentration of 4-CP increases, a greater number of 4-CP molecules are subjected to SO4•−, hence enhancing the probability of collisions between SO4•− and 4-CP molecules, leading to an increased degradation rate of 4-CP per unit time [21]. The degradation rate for 10, 20 and 30 mg/L of 4-CP was 0.625, 0.983 and 1.225 mg/L/min, for UV/persulfate technique (Table 1). Moreover, for UV/persulfate/Fe2+ technique the degradation rate was 0.708, 1.100 and 1.335 mg/L/min, respectively, for 10, 20 and 30 mg/L of 4-CP, (Table 1). Table 1Influence of [4-CP]0 on degradation rate (initial 12 min). Experimental conditions: PS = 0.5 mM, [Fe2+]0 = 0.3 mg L− 1, pH = 6.0 (UV/PS) and 3.0 (UV/PS/Fe2+)4-CP concentration (mg L− 1)Degradation rate (mg/L/min) for UV/PSDegradation rate (mg/L/min) for UV/PS/Fe2+100.6250.708200.9831.100301.2251.335 Table 1Influence of [4-CP]0 on degradation rate (initial 12 min). Experimental conditions: PS = 0.5 mM, [Fe2+]0 = 0.3 mg L− 1, pH = 6.0 (UV/PS) and 3.0 (UV/PS/Fe2+)4-CP concentration (mg L− 1)Degradation rate (mg/L/min) for UV/PSDegradation rate (mg/L/min) for UV/PS/Fe2+100.6250.708200.9831.100301.2251.335 Influence of [4-CP]0 on degradation rate (initial 12 min). Experimental conditions: PS = 0.5 mM, [Fe2+]0 = 0.3 mg L− 1, pH = 6.0 (UV/PS) and 3.0 (UV/PS/Fe2+) Fig. 3Influence of [4-CP]0 on removal efficacy of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b) techniques. Experimental conditions: PS = 0.5 mM, Fe2+ = 0.3 mg L− 1, pH = 6 (UV/persulfate) and 3 (UV/persulfate/Fe2+) Influence of [4-CP]0 on removal efficacy of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b) techniques. Experimental conditions: PS = 0.5 mM, Fe2+ = 0.3 mg L− 1, pH = 6 (UV/persulfate) and 3 (UV/persulfate/Fe2+) Impact of [Fe2+]0 in UV/PS/Fe2+ technique High amounts of Fe²⁺ can precipitate, leading to additional secondary treatment and increased operational costs for large-scale water treatment systems [40]. Therefore, the impact of initial [Fe2+]0 was evaluated for 0.1, 0.3 and 0.5 mg/L. The % degradation of 4-CP was 94.0% for 0.1 mg/L of Fe2+ and 100% for both 0.3 and 0.5 mg/L of Fe2+, employing 4-CP = 20 mg/L and pH = 3, after 25 min of irradiation (Fig. 4). Similarly, the observed rate constant for 0.1, 0.3 and 0.5 mg/L of Fe2+ was 0.0891, 0.113 and 0.1354 min− 1, respectively. The % degradation of 4-CP increases as Fe2+ concentration rises because Fe2+ catalytically activates PS which produce SO4•− (reaction (9)) [39]. Fig. 4Influence of [Fe2+]0 on degradation of 4-CP by photo-Fenton like method. Reaction conditions: [4-CP]0 = 20 mg/L, PS = 0.5 mM, and pH = 3 Influence of [Fe2+]0 on degradation of 4-CP by photo-Fenton like method. Reaction conditions: [4-CP]0 = 20 mg/L, PS = 0.5 mM, and pH = 3 Table 2 shows the removal efficiencies of different pollutants by UV/PS and UV/PS/Fe2+ processes. Table 2Degradation comparison of different pollutants by UV/PS and UV/PS/Fe2+ processesMethodPollutantConcentrationExperimental conditionsTime (min)Degradation (%)ReferenceUV/PSAcetamiprid90 µMPS = 1.5 mM, pH = 7, T = 25 °C60100 [41]UV/PSRhodamine B5 µMPS = µM, pH = 7.01598.3 [42]UV/PSBenzothiazole10 mg/LPS = 150 mg/L, pH = 7.060100 [43]UV/PSMethyl paraben32.8 µMPS = 1 mM, pH = 6.59098.9 [44]UV/PSPropranolol20 µMPS = 0.4 mM, pH = 73091.8 [45]UV/PS/Fe2+Catechol40 mg/LFe2+ = 0.2 g/L, PS = 3 mM, pH = 4, T = 25 ± 1 °C3076.5 [46]UV/PS/Fe2+Caffeine0.0125 mMFe2+ = 0.1 mM, PS = 0.3 mM, pH = 44100 [47]UV/PS/Fe2+Amicarbazone41.4 µMFe2+ = 0.134 mM, PS = 2.5 mM2.5100 [48]UV/PS4-CP20 mg/LPS = 0.5 mM, pH = 6.025100This studyUV/PS/Fe2+4-CP20 mg/LPS = 0.5 mM, Fe2+ = 0.5 mg/L, pH = 3.020100This study Table 2Degradation comparison of different pollutants by UV/PS and UV/PS/Fe2+ processesMethodPollutantConcentrationExperimental conditionsTime (min)Degradation (%)ReferenceUV/PSAcetamiprid90 µMPS = 1.5 mM, pH = 7, T = 25 °C60100 [41]UV/PSRhodamine B5 µMPS = µM, pH = 7.01598.3 [42]UV/PSBenzothiazole10 mg/LPS = 150 mg/L, pH = 7.060100 [43]UV/PSMethyl paraben32.8 µMPS = 1 mM, pH = 6.59098.9 [44]UV/PSPropranolol20 µMPS = 0.4 mM, pH = 73091.8 [45]UV/PS/Fe2+Catechol40 mg/LFe2+ = 0.2 g/L, PS = 3 mM, pH = 4, T = 25 ± 1 °C3076.5 [46]UV/PS/Fe2+Caffeine0.0125 mMFe2+ = 0.1 mM, PS = 0.3 mM, pH = 44100 [47]UV/PS/Fe2+Amicarbazone41.4 µMFe2+ = 0.134 mM, PS = 2.5 mM2.5100 [48]UV/PS4-CP20 mg/LPS = 0.5 mM, pH = 6.025100This studyUV/PS/Fe2+4-CP20 mg/LPS = 0.5 mM, Fe2+ = 0.5 mg/L, pH = 3.020100This study Degradation comparison of different pollutants by UV/PS and UV/PS/Fe2+ processes Influence of pH One of the most vital parameters to assess the effectiveness of AOPs for pollutants degradation is the solution’s pH, which might have impact on the rate of chemical reactions by producing radicals [49]. The stability of oxidants, the production and redox potential of SO4•− and •OH, and kind of iron species in solution during the advanced oxidation process are all directly impacted by pH [50, 51]. To examine the influence of pH on the degradation efficiency of 4-CP, experiments were performed at pH 3.0, 6.0, and 11.0 for the UV/persulfate technique, and pH 3 and 6 for the UV/persulfate/Fe2+ technique. The experiment at pH 11 was not conducted in the case of UV/persulfate/Fe2+. The reason for this is that the Fe2+ converted into ferric oxyhydroxide species at alkaline pH, which are unable to efficiently activate PS [50]. The removal efficacy of 4-CP was 90.3% at pH 3, while complete removal of 4-CP occurs at pH 6 and 11, using 4-CP (20 mg/L), PS (0.5 mM), after 25 min (Fig. 5a). Similarly, as the pH increases from 3 to 6 the kobs increases from 0.0634 to 0.0876 min− 1. However, the observed rate constant increases to 0.0971 as pH increases to 11. The increase in degradation of 4-CP at alkaline pH is due to the efficient absorption of UV light in its anionic state [36]. Similarly, at alkaline pH, PS can be activated by both base and UV, which produce more SO4•− (reactions (10)–(12)) [28]. Similar, results were obtained for the enhanced removal of diclofenac and phenol at alkaline pH [52, 53].10\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${{\mathrm{S}}_{\mathrm{2}}}{{\mathrm{O}}_{\mathrm{8}}}^{{{\mathrm{2}}-}}+{\text{ }}{{\mathrm{H}}_{\mathrm{2}}}{\text{O }} \xrightarrow{\mathrm{NaOH}}{\text{ }}{{\text{}}_{\text{}}}^{ }{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}}-}}+ {\text{ S}}{{\mathrm{O}}_{\mathrm{5}}}^{{{\mathrm{2}}-}} + {\text{ 2}}{{\mathrm{H}}^+}$$\end{document}11\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${{\mathrm{S}}_{\text{}}}{{\mathrm{O}}_{\mathrm{5}}}^{{{\mathrm{2}}-}}+{\text{ }}{{\mathrm{H}}_{\mathrm{2}}}{\text{O }} \xrightarrow{\mathrm{NaOH}} {\text{ }}{{\text{}}_{\text{}}}^{ }{\text{ H}}{{\mathrm{O}}_{\mathrm{2}}}^{{{\text{}}-}}+ {\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}}-}} + {\text{ }}{{\mathrm{H}}^+}$$\end{document}12\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{H}}{{\mathrm{O}}_{\mathrm{2}}}^{ - }+{\text{ }}{{\mathrm{S}}_{\mathrm{2}}}{{\mathrm{O}}_{\mathrm{8}}}^{{{\mathrm{2}}-}} \to {\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}}-}}+{{\mathrm{H}}^+}+{\text{ }}{{\mathrm{O}}_{\mathrm{2}}}^{{ \bullet - }}$$\end{document} However, the photo-Fenton like technique was investigated at two different pH level (pH 3.0 and 6.0). The removal efficacy of 4-CP was 100 and 94%, at pH 3 and 6, using 4-CP = 20 mg/L, PS = 0.5 mM and Fe2+ = 0.3 mg/L, after 25 min of irradiation (Fig. 5b). Similarly, the observed rate constant at pH 3 and 6 was 0.113 and 0.0906 min− 1, accordingly. The maximum activity of Fe2+ has been reported to be at acidic pH. The catalytic activity of Fe2+ decreases as the pH increases from 3 to 6, because Fe2+ converted into Fe3+ and get precipitated [54]. Hence, the degradation efficiency of 4-CP is more at acidic pH compared to neutral pH in UV/PS/Fe2+ process. Fig. 5Impact of pH on removal of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b). Experimental conditions: [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L and PS = 0.5 mM Impact of pH on removal of 4-CP by UV/persulfate (a) and UV/persulfate/Fe2+ (b). Experimental conditions: [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L and PS = 0.5 mM To elucidate the efficiency of the AOPs examined in this study relative to previously reported AOPs for the degradation of 4-CP, shown in Table 3. Table 3 enhances the current understanding of the elimination of 4-CP by various AOPs. Table 3Evaluation of various AOPs for the removal of 4-CPMethods4-CP (mg/L)Experimental conditionsTime (min)Degradation (%)ReferenceUV/PS200.5 mM PS, pH 6.025100This studyUV/PS/ Fe2+200.5 mM PS, 0.5 mg/L Fe2+, pH 3.020100This studyFOCT/UV/PS604.0 mM PS, pH 5.0, UV- C lamp (PHILIPS, 8 W)6099 [55]Ultrasound/persulfate15125 mg/L PS, pH 3.0 and ultrasound power = 150 W6589 [20]UV/H2O2/NiO1000.2 mol/L H2O2, nickel oxide 0.05 g/L, pH 7.0, UV lamp 150 W (medium-pressure lamp)60100 [56]UV/MnO2/PMS25PMS = 1 mM, MnO2 = 0.25 g/L =, pH = 4.0, UVC-LEDs (6 lamps, 1 W each, wavelength = 258–262 nm)30100 [57]UV/H2O21000.012 M H2O2, pH 11, UV 16 W lamp (λ = 254 nm)60> 99%, [58]UV/H2O2/ Fe2+1000.012 M H2O2, 50 mg/ L Fe2+, pH 3.0, UV 16 W lamp (λ = 254 nm)2.5100 [58] Table 3Evaluation of various AOPs for the removal of 4-CPMethods4-CP (mg/L)Experimental conditionsTime (min)Degradation (%)ReferenceUV/PS200.5 mM PS, pH 6.025100This studyUV/PS/ Fe2+200.5 mM PS, 0.5 mg/L Fe2+, pH 3.020100This studyFOCT/UV/PS604.0 mM PS, pH 5.0, UV- C lamp (PHILIPS, 8 W)6099 [55]Ultrasound/persulfate15125 mg/L PS, pH 3.0 and ultrasound power = 150 W6589 [20]UV/H2O2/NiO1000.2 mol/L H2O2, nickel oxide 0.05 g/L, pH 7.0, UV lamp 150 W (medium-pressure lamp)60100 [56]UV/MnO2/PMS25PMS = 1 mM, MnO2 = 0.25 g/L =, pH = 4.0, UVC-LEDs (6 lamps, 1 W each, wavelength = 258–262 nm)30100 [57]UV/H2O21000.012 M H2O2, pH 11, UV 16 W lamp (λ = 254 nm)60> 99%, [58]UV/H2O2/ Fe2+1000.012 M H2O2, 50 mg/ L Fe2+, pH 3.0, UV 16 W lamp (λ = 254 nm)2.5100 [58] Evaluation of various AOPs for the removal of 4-CP Effect of inorganic ions and humic acid The effectiveness of the oxidation process can be impacted by certain frequent ions in actual wastewater reacting with •OH and SO4•−. Therefore, experiments were performed to study the impact of chloride, carbonate, bicarbonate and humic acid (HA) in UV/PS process. Similarly, the effect of chloride and HA were evaluated in UV/PS/Fe2+ process, as carbonate and bicarbonate increase the pH of solution, thereby decreasing the catalytic activity of Fe2+. The % degradation of 4-CP decreases from 100% to 94.8, 84.6, 81.8 and 70.3% in presence of chloride, carbonate, bicarbonate and HA (Fig. 6a). Similarly, observed rate constant decreases from 0.0876 to 0.0773, 0.0639, 0.061 and 0.045 min− 1, in absence of scavenger, chloride, carbonate, bicarbonate and HA. The addition of CO32− and HCO3− ions reduces the removal efficiency of 4-CP as it scavenges both SO4•− and •OH and transforms into weak carbonate radicals (E0 = 1.78 V) (reactions (13)–(16)) [59, 60].13\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ HC}}{{\mathrm{O}}_{\mathrm{3}}}^{ - } \to {\text{ HC}}{{\mathrm{O}}_{\mathrm{3}}}^{ \bullet }+{\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}} - }}k\,=\,{\mathrm{1}}.{\text{6 }} \times {\mathrm{1}}{0^{\mathrm{6}}}{{\mathrm{M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document}14\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{SO}}_{{\mathrm{4}}} ^{{ \bullet - }} + {\mathrm{CO}}_{{\mathrm{3}}} ^{{{\text{2 - }}}} \to {\mathrm{SO}}_{{\mathrm{4}}} ^{{{\mathrm{2}} - }} + {\text{ CO}}_{{\mathrm{3}}} ^{{ \bullet - }} ~~~~~~~~k = {\mathrm{6}}.{\mathrm{1}} \times {\mathrm{1}}0^{{\mathrm{6}}} {\mathrm{M}}^{{ - {\mathrm{1}}}} {\mathrm{s}}^{{ - {\mathrm{1}}}} $$\end{document}15\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{CO}}_{{\mathrm{3}}} ^{{{\text{2 - }}}} + ^{ \bullet } {\text{OH }} \to {\mathrm{CO}}_{{\mathrm{3}}} ^{{ \bullet - }} + {\mathrm{OH}}^{ - } ~~~~~~~~~~k = {\text{ 3}}.{\mathrm{9}} \times {\mathrm{1}}0^{{\mathrm{8}}} {\mathrm{M}}^{{ - {\mathrm{1}}}} {\mathrm{s}}^{{ - {\mathrm{1}}}} $$\end{document}16\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{HCO}}_{{\mathrm{3}}} ^{ - } + ^{ \bullet } {\text{OH }} \to {\mathrm{CO}}_{{\mathrm{3}}} ^{{ \bullet - }} + {\mathrm{H}}_{{\mathrm{2}}} {\mathrm{O}}~~~~~~~~k = {\text{ 8}}.{\mathrm{5}} \times {\mathrm{1}}0^{{\mathrm{6}}} {\mathrm{M}}^{{ - {\mathrm{1}}}} {\mathrm{s}}^{{ - {\mathrm{1}}}} $$\end{document} In UV/persulfate/Fe2+ technique, the removal efficacy decreases from 100% to 92.3 and 67.8%, in presence of chloride and HA (Fig. 6b). Similarly, the rate constant decreases from 0.113 to 0.0748 and 0.0427 min− 1, in presence of chloride and HA. The decrease in degradation by chloride is due to the scavenging of SO4•− and •OH by chloride ions and convert into weak chloride radicals (reactions (17)–(22)) [61, 62].17\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\mathrm{C}}{{\mathrm{l}}^ - } \to {\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{{\mathrm{2}} - }}+{\text{ C}}{{\mathrm{l}}^ \bullet }k\,=\,{\mathrm{2}}.{\mathrm{7}}--{\mathrm{6}}.{\text{6 }} \times {\mathrm{1}}{0^{\mathrm{8}}}{{\mathrm{M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document}18\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{Cl}}^{ \bullet } + {\mathrm{Cl}}^{ - } \to {\text{ Cl}}_{{\mathrm{2}}} ^{{ \bullet - }} ~~~~~k = {\text{ 8}}.{\mathrm{5}} \times {\mathrm{1}}0^{{\mathrm{9}}} {\mathrm{M}}^{{ - {\mathrm{1}}}} {\mathrm{s}}^{{ - {\mathrm{1}}}} $$\end{document}19\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$^{ \bullet }{\mathrm{OH}}\,+\,{\mathrm{C}}{{\mathrm{l}}^ - } \to {\text{ ClH}}{{\mathrm{O}}^ \bullet }^{ - }k\,=\,{\mathrm{4}}.{\mathrm{3}} \times {\mathrm{1}}{0^{\mathrm{9}}}{{\mathrm{M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document}20\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{ClH}}{{\mathrm{O}}^ \bullet }^{ - }+{\text{ }}{{\mathrm{H}}^+} \to {\text{ }}{{\mathrm{H}}_{\mathrm{2}}}{\mathrm{O}}\,+\,{\mathrm{C}}{{\mathrm{l}}^ \bullet }k\,=\,{\mathrm{3}}.0 \times {\mathrm{1}}{0^{{\mathrm{1}}0}}{{\mathrm{M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document}21\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{C}}{{\mathrm{l}}^ \bullet }+{\text{ C}}{{\mathrm{l}}^ \bullet } \to {\text{ C}}{{\mathrm{l}}_{\text{2 }}} k\,=\,{\mathrm{8}}.{\mathrm{8}} \times {\mathrm{1}}{0^{\mathrm{7}}}{{\mathrm{M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document}22\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{Cl}}_{{\mathrm{2}}} ^{{ \bullet - }} + ^{ \bullet } {\text{OH }} \to ~~{\text{ClHO }} + {\mathrm{Cl}}^{ - } ~~k = {\text{ 1}} \times {\mathrm{1}}0^{{\mathrm{9}}} {\mathrm{M}}^{{ - {\mathrm{1}}}} {\mathrm{s}}^{{ - {\mathrm{1}}}} $$\end{document} The following factors contribute to the reduction in 4-CP degradation by HA in UV/persulfate and photo-Fenton like techniques. One is that because HA absorbs UV light, it competes with 4-CP for UV light-induced direct photolysis [63]. Second, HA has an adverse effect on 4-CP degradation because it scavenges SO4•− (reaction (23)) [64].23\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{S}}{{\mathrm{O}}_{\mathrm{4}}}^{{ \bullet - }}+{\text{ NOM }} \to {\text{Products k}}\,> \, {\mathrm{6}}.0{\text{ }} \times {\text{ 1}}{0^{\mathrm{6}}} {{\text {M}}^{ - \,{\mathrm{1}}}}{{\mathrm{s}}^{ - \,{\mathrm{1}}}}$$\end{document} Furthermore, NOM is a strong UV light absorber that competes with PS for radiant flux and may lower the levels of reactive radicals [64]. The inhibitory effect of HA is more in UV/PS/Fe2+ process because more reactive radicals are formed in UV/PS/Fe2+ process, thereby reacting more with NOM. Fig. 6Effect of ions (Cl−, CO32− and HCO3−) and HA on % degradation of 4-chlorophenol by UV/persulfate (a) and UV/persulfate/Fe2+ (b). Experimental conditions: [4-chlorophenol]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L and PS = 0.5 mM, [Each ion]0 = 5 mM, [HA]0 = 10 mg/L, pH = 6.0 (UV/persulfate technique) and 3 (UV/persulfate/Fe2+ technique). In case of HCO32− and CO32−, pH = 7.8, for UV/PS process Effect of ions (Cl−, CO32− and HCO3−) and HA on % degradation of 4-chlorophenol by UV/persulfate (a) and UV/persulfate/Fe2+ (b). Experimental conditions: [4-chlorophenol]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L and PS = 0.5 mM, [Each ion]0 = 5 mM, [HA]0 = 10 mg/L, pH = 6.0 (UV/persulfate technique) and 3 (UV/persulfate/Fe2+ technique). In case of HCO32− and CO32−, pH = 7.8, for UV/PS process TOC analysis The main goal of water treatment technology is to remove or reduce the harmful organic compounds in contaminated water. Therefore, it is crucial to assess the effectiveness of a specific water treatment technique in diminishing the total organic carbon (TOC) of a certain contaminant [61]. The Elimination of TOC from 4-CP solution using UV/persulfate and photo-Fenton like systems was investigated. The removal of the TOC required more time than the total removal of the 4-CP. The removal of TOC was investigated at pH 6.0 for the UV/PS technique to enhance its applicability to natural water conditions. Similarly, the removal of TOC was investigated at pH 3.0 for the UV/PS/Fe2+ method, as Fe2+ demonstrates enhanced catalytic activity in acidic conditions. The achieved TOC removal of 4-CP was 65.8 and 86.1% for the UV/PS and UV/PS/Fe2+ procedures, respectively, after 120 min (Fig. 7). The enhanced TOC removal of 4-CP in the photo-Fenton like technique is attributable to the triggering of PS via UV light and Fe2+, leading to the generation of higher number of SO4•− (reactions (7) and (9)). Fig. 7 TOC removal by UV/PS and UV/PS/Fe2+. [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L, PS = 0.5 mM, pH = 6 (UV/persulfate) and 3 (UV/persulfate/Fe2+) TOC removal by UV/PS and UV/PS/Fe2+. [4-CP]0 = 20 mg/L, [Fe2+]0 = 0.3 mg/L, PS = 0.5 mM, pH = 6 (UV/persulfate) and 3 (UV/persulfate/Fe2+) Relative contribution of reactive radicals Radical quenching experiments were conducted to evaluate the relative contributions of reactive species in the UV/PS process. Tertiary-butyl alcohol (t-BuOH) was employed as a selective HO• scavenger, whereas methanol was used to quench both SO4•− and HO• [65]. Under the experimental conditions of [4-CP]0 = 20 mg L⁻1, PS = 0.5 mM, pH = 6, the degradation efficiency of 4-CP decreased from 100 to 94.3% upon the addition of 10 mM t-BuOH after 25 min of UV irradiation (Fig. 8). This 5.7% reduction in removal efficiency can be attributed to the scavenging of HO• by t-BuOH. Similarly, the addition of 10 mM methanol reduced the degradation efficiency from 100 to 63.5% after 25 min of irradiation, corresponding to a 36.5% decrease, indicating major contribution of SO4•− in the degradation of 4-CP in UV/PS process (Fig. 8). Moreover, the contribution of SO4•− is 30.6%, i.e., HO• − SO4•− (94.3 − 63.5 = 30.6%). For comparison, direct photolysis achieved 58.8% degradation of 4-CP at 25 min. Therefore, the degradation efficiency of 4-CP in the methanol/UV/PS system was 4.7% higher (63.5–58.8 = 4.7%) than that observed under direct photolysis. This additional removal may be attributed to the contribution of singlet oxygen (1O2) or the presence of residual reactive radical species that persisted despite the addition of methanol. Fig. 8Degradation of 4-CP in presence of methanol and t-BuOH in UV/PS process. Experimental conditions: [4-CP]0 = 20 mg/L, PS = 0.5 mM, [methanol]0 = [t-BuOH]0 = 10 mM, pH = 6 Degradation of 4-CP in presence of methanol and t-BuOH in UV/PS process. Experimental conditions: [4-CP]0 = 20 mg/L, PS = 0.5 mM, [methanol]0 = [t-BuOH]0 = 10 mM, pH = 6 Economic calculations The effectiveness of the UV/PS and UV/PS/Fe2+ techniques were evaluated in terms of economic cost. The total cost for UV/PS and UV/PS/Fe2+ processes were 0.7583 and 0.7971 $ m− 3. The total cost of UV/PS/Fe2+ process is high due to the cost of Fe2+. Therefore, its cost will be reduced if UV/PS/Fe2+ technique is applied at commercial scale. However, the presence of iron in natural water may aid in sustaining the UV/PS/Fe2+ process, and no additional iron needs to be added to the water. That is why the cost might be decreased by removing the use of an external iron source, allowing the iron-containing water to act as a photocatalyst for PS activation. In order to calculate the UV/PS and UV/PS/Fe2+ techniques economically, electrical energy per order (EE/O) was used. The quantity of electrical energy (measured in kilowatt hours) required to remove 90% of a pollutant from 1 m3 of contaminated air or water is known as EE/O (Eq. (24)) [21].24\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\frac{\mathrm{E}\mathrm{E}}{\mathrm{O}}=\frac{\mathrm{P}\mathrm{t}}{\mathrm{V}}$$\end{document} In Eq. (23), P represents the total electrical power or flux that enters the solution, t denotes the irradiation period, and V indicates the solution volume measured in m3. The overall expenses associated with electrical energy and the analyzed UV/PS process were calculated using (Eqs. (25) and (26)), respectively, with an electricity price set at 0.08$/kWh, of which 45% was allocated to maintenance costs. Table 4 shows the overall expenses and electrical energy corresponding with the UV/PS and UV/PS/Fe2+ processes for achieving one-order removal of 4-CP. The price of PS was 0.00636 $/g [66], and Fe2+ was 0.13009 $/g.25\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\begin{aligned} {\text{Electrical energy cost }}(\$ {\mathrm{m}}^{{ - {\text{ 3}}}} ){\text{ }} = & {\text{ Power cost }}(\$ /{\text{KW h}}){\text{ }} \\ & \times {\text{ EE}}/{\text{O }}({\text{KW h m}}^{{ - {\text{ 3}}}} ) \\ \end{aligned} $$\end{document}26\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\begin{aligned} {\text{Total cost of process }}(\$ {\mathrm{m}}^{{ - {\text{ 3}}}} ){\text{ }} = & {\text{ }}\left( {{\mathrm{1}}.{\text{45 }} \times {\text{ electrical energy cost}}} \right) \\ & + {\text{ reagent cost}} \\ \end{aligned} $$\end{document} Table 4Economic calculations for UV/PS and UV/PS/Fe2+ processes for degradation of 4-CP. 4-CP = 20 mg/L, Fe2+ = 0.3 mg/L, PS = 0.5 mM, pH = 6 (for UV/PS) and 3 (for UV/PS/Fe2+)Oxidation processUV/PS*UV/PS/Fe2+kobs (cm2 mJ− 1)0.01830.0235UV fluence needed for one-order removal of 4-CP (mJ cm− 2)125.898.0EE/O (kW h m− 3/order)1.64 × 10− 29.80 × 10− 3Electricity cost ($ m− 3)9.31 × 10− 47.84 × 10− 4Reagent cost ($ g− 1)0.006360.13009Total cost ($ m− 3)0.75830.7971*The cost of Fe2+ is taken from the Merck website Table 4Economic calculations for UV/PS and UV/PS/Fe2+ processes for degradation of 4-CP. 4-CP = 20 mg/L, Fe2+ = 0.3 mg/L, PS = 0.5 mM, pH = 6 (for UV/PS) and 3 (for UV/PS/Fe2+)Oxidation processUV/PS*UV/PS/Fe2+kobs (cm2 mJ− 1)0.01830.0235UV fluence needed for one-order removal of 4-CP (mJ cm− 2)125.898.0EE/O (kW h m− 3/order)1.64 × 10− 29.80 × 10− 3Electricity cost ($ m− 3)9.31 × 10− 47.84 × 10− 4Reagent cost ($ g− 1)0.006360.13009Total cost ($ m− 3)0.75830.7971*The cost of Fe2+ is taken from the Merck website Economic calculations for UV/PS and UV/PS/Fe2+ processes for degradation of 4-CP. 4-CP = 20 mg/L, Fe2+ = 0.3 mg/L, PS = 0.5 mM, pH = 6 (for UV/PS) and 3 (for UV/PS/Fe2+) *The cost of Fe2+ is taken from the Merck website Degradation products The assessment of the target pollutant’s removal is frequently employed to evaluate the treatment process’s efficiency; however, the generation of degradation products during this process presents significant challenges. These DPs exhibit greater resistance to breakdown and elevate the toxicity levels of treated water. Therefore, it is essential to take into account information regarding the DPs of target pollutants [67]. The breakdown of 4-chlorophenol results in the production of hydroquinone, 1,4-benzoquinone, and 4-chlorocatechol. Prior studies indicate that electron transfer and abstraction of hydrogen are presumed to be the initial steps in the SO4•− attack during the oxidation of 4-chlorophenol [68]. A sulphate radical-induced attack on a benzene ring results in the generation of carbon-centered radicals through transfer of electrons from the organic component to the sulphate radicals [69]. The hydrolysis of the radical cation generated post-sulfate elimination leads to the production of hydroxylated radical products, which subsequently react with O2 to yield the stable intermediates hydroquinone and 4-chlorocatechol. Similarly, 1,4-Benzoquinone is subsequently generated through hydrogen abstraction from hydroquinone [33]. Further, these aromatic ring DPs were oxidized and convert into open chain oxalic and acetic acid. At the end, complete mineralization of 4-CP occur [70] as shown in Scheme 1. Scheme 1Degradation pathways of 4-CP by UV/PS process Degradation pathways of 4-CP by UV/PS process Toxicity investigation The main purpose of a water treatment technology is to produce pure, clean water devoid of hazardous pollutants. Therefore, the toxicity of the treated solution should be evaluated before recommending a water treatment system for practical implementation. Herein, the toxicity of 4-CP and its degradation products towards three aquatic organisms including fish, daphnia and green algae were assessed using ECOSAR program (Table 5). The criteria and guidelines of Chinese hazard evaluation for new chemical compounds/substances (HJ/T154-2004) were applied to assess the chronic toxicities of the compounds of interest. These criteria were as follows: ChV greater than 10 (not harmful), 1 < ChV < 10 (harmful), 0.1 < ChV < 1 (toxic), and ChV less than 0.1 (extremely toxic). On the other hand, the acute toxicities were examined in compliance with the European Union standards [71]. According to these recommendations, substances with higher acute and chronic toxicities have lower ChV, LC50, and EC50 values. Fortunately, the acute and chronic toxicities of the identified DPs was found to be less than the parent 4-CP. As a result, the UV/PS process is an efficient water treatment system when used for purification of chlorophenols containing water. Table 5Aquatic toxicity of 4-CP and its identified DPs (unit = mg L− 1)CompoundAcute toxicityChronic toxicityFish (LC50)Daphnia (LC50)Green Algae (EC50)Fish(ChV)Daphnia(ChV)Green Algae(ChV)4-CP76.334.934.87.594.469.404-Chlorocatechol2321288421.911.520.6Hydroquinone66934717958.826.438.41,4-Benzoquinone33301610614269100112Oxalic acid168,00067,50012,10010,90025201470Acetic acid25,80012,30044002050732778 Table 5Aquatic toxicity of 4-CP and its identified DPs (unit = mg L− 1)CompoundAcute toxicityChronic toxicityFish (LC50)Daphnia (LC50)Green Algae (EC50)Fish(ChV)Daphnia(ChV)Green Algae(ChV)4-CP76.334.934.87.594.469.404-Chlorocatechol2321288421.911.520.6Hydroquinone66934717958.826.438.41,4-Benzoquinone33301610614269100112Oxalic acid168,00067,50012,10010,90025201470Acetic acid25,80012,30044002050732778 Aquatic toxicity of 4-CP and its identified DPs (unit = mg L− 1) Conclusion This study investigated the removal of 4-CP by three different processes such as sole UV, UV/persulfate, and photo-Fenton like techniques. The removal efficacy in UV alone of 4-CP was 44.7, 58.8 and 66.8% degradation of 4-CP (20 mg/L), at pH 3, 6, and 11, after 25 min of treatment. The addition of 0.5 mM PS to UV enhances the removal of 4-CP to 90.2% (pH 3) and 100% (pH 6 and 11), respectively after 25 min. Furthermore, complete removal of 4-CP occurs in photo-Fenton like process using Fe2+ = 0.3 mg/L, PS = 0.5 mM, 4-CP = 20 mg/L, at pH 3, after 25 min of irradiation. Additionally, the degradation efficacy was adversely affected by humic acid (HA) and inorganic ions. The degradation of 4-CP decreases from 100% to 94.8, 84.6, 81.8 and 70.3% in presence of chloride, carbonate, bicarbonate and HA. Similarly, the TOC removal of 4-CP was 65.8 and 86.1%, in UV/persulfate and UV/persulfate/Fe2+ techniques, after 120 min. However, the DPs were determined by GC – MS. Moreover, the contribution of SO4•− and HO• was investigated by scavenging study. Finally, ECOSAR program was used to assess the toxicity of 4-CP and its detected DPs against fish, daphnia and green algae. The developed UV/persulfate and UV/persulfate/Fe2+ processes show promising potential for the treatment of industrial and municipal wastewater, including complex effluents containing multiple organic pollutants. These processes can be applied to real water matrices, offering efficient degradation under optimized conditions. However, limitations such as sensitivity to water matrix components, the need for careful optimization of reagent dosages, and UV penetration in large-scale systems should be considered for practical implementation. Nevertheless, this work suggests that the UV/persulfate and UV/persulfate/Fe2+ processes can be efficient methods for removing of 4-CP from aquatic compartments.