Analysis of the impact of altitude changes on human physiological indicators and response capabilities Authors: Jia Haijiang, Wang Xiaodong, Hu Bin, Chen Mengyao, Ming Zhao Published: 2026 ABSTRACT AbstractHypoxic environments represent a core stress factor affecting human physiological functions and cognitive performance under high-altitude exposure. This study utilized an environmental experiment chamber to replicate varying altitude conditions, tracking and recording parameters such as blood pressure, Blood oxygen saturation, heart rate, and cognitive response capabilities in test subjects, while evaluating the interrelationships and mutual influences among these indicators. Results demonstrated that young populations exhibit stronger adaptability to high-altitude hypoxia; no significant linear correlation was observed between age and reaction time, although age-related differences were noted in auditory response time. Blood oxygen saturation showed no significant correlation with reaction time, suggesting that physiological compensations can maintain response speed. Heart rate exhibited a weak positive correlation with systolic blood pressure (r = 0.378), with synergistic changes enhancing reaction accuracy by 12%. Discrimination reaction time significantly prolonged when Blood oxygen saturation < 85% and heart rate > 110 beats per minute. A fatigue early warning method based on key physiological indicators and reaction time data, along with corresponding threshold values, was proposed. This provides actionable quantitative evidence for real-time monitoring and risk assessment of fatigue status in high-altitude work environments, facilitating scientifically guided rest scheduling and workload regulation to improve safety standards and operational efficiency in high-altitude operations.Supplementary InformationThe online version contains supplementary material available at https://doi.org/10.1038/s41598-026-56813-x.Keywords: High altitude, Hypoxia, Cognitive function, Reaction time, SpO2, FatigueSubject terms: Neuroscience, Physiology Introduction High-altitude environments exert extensive impacts on human physiological functions and cognitive abilities due to decreased atmospheric pressure and oxygen partial pressure. Compared to low-altitude airports, high-altitude airports face greater urgency in risk management of human factors, as their unique low-pressure, hypoxic, and cold environments significantly increase error rates among staff, thereby exacerbating operational safety risks. Studies indicate that the hypobaric and hypoxic environment at an altitude of 3,600 m can induce a series of physiological responses, including adaptations in pulmonary ventilation, hemodynamics, and cardiovascular systems1. Blood oxygen saturation (SpO2) and alveolar oxygen partial pressure (PaO2), as key indicators for assessing altitude sickness, exhibit dynamic changes closely correlated with the degree of hypoxia and adaptive status. Medical research by Ye Chaoliang et al. confirmed that normal arterial blood oxygen saturation ranges between 93% and 98%, with values below 93% classified as hypoxemia. When SpO2 drops to 85%, it may lead to impaired cognitive concentration and reduced muscle fine motor coordination; at 75%, misjudgment and muscle dysfunction occur; and at 60%, loss of consciousness may ensue2. Wei Yi’s study on physical fitness testing in military and police academies revealed that performance in rapid-response and coordination tasks (e.g., 4 × 10-meter sprint) significantly declines under hypoxic conditions (P < 0.001), indicating specific interference with temporal control of complex movements3. Hypoxic environments impair neuromuscular function through multiple mechanisms, including reduced motor neuron firing frequency, decreased muscle fiber contraction velocity, and disrupted sensory feedback integration, ultimately manifesting as prolonged reaction times and reduced movement precision. From a physiological perspective, hypoxia exerts multidimensional effects on the human body. Beyond the nervous system, individuals transitioning from lowland to high-altitude environments often experience increased heart rate, blood pressure fluctuations, and decreased blood oxygen saturation. When blood oxygen saturation falls below 92%, the body exhibits significant hypoxic responses4–6. The decline in blood oxygen saturation can trigger reflexive reactions such as increased respiratory rate and elevated maximum expiratory volume to mitigate the downward trend7. This process further accelerates heart rate in high-altitude individuals, induces sympathetic nervous system excitation, and subsequently impairs cognitive function—representing just one potential factor contributing to cognitive impairment in high-altitude environments8,9. During the initial phase of high-altitude exposure, hypoxic conditions primarily manifest as diminished auditory and visual perception, reduced attention span and attentional shift capacity, impaired short-term memory, as well as decreased complex reasoning ability and cognitive flexibility10,11. The effects of hypoxic conditions in high-altitude environments on human brain function encompass multiple aspects, including emotional regulation, reflex activities, perceptual and memory capacities, as well as motor coordination and accuracy. In high-altitude settings, higher elevations correlate with more pronounced low atmospheric pressure and hypoxia, leading to significant declines in both cognitive and physical performance. Hypoxic environments impair cognitive abilities, emotional states, and working memory12,13, increasing operational vulnerability and posing risks to flight safety. However, systematic quantitative analyses linking overall physiological indicators with response capabilities remain scarce. With the continuous growth of air traffic volume, the relationship between controller fatigue and air traffic safety has become increasingly critical. The U.S. Aviation Safety Report indicates that 21% of flight safety incidents are attributed to controller fatigue14. The International Civil Aviation Organization (ICAO) further notes that fatigue, induced by irregular work schedules or excessive workload, compromises controllers ‘attention, memory, and decision-making abilities during cognitive processes, thereby increasing the likelihood of accidents15. Fatigue-induced cognitive impairment is a primary cause of aviation safety incidents; thus, investigating controllers’ cognitive performance under fatigue conditions holds significant practical implications for enhancing air traffic safety16. This study focuses on airport tower controllers to examine the evolution of physiological indicators and response capabilities across different altitudes, aiming to identify key metrics for fatigue detection. Experimental design This study simulated environments at three altitude levels: 114 m, 2950 m, and 3650 m. Cognitive performance tests (including auditory reaction time, visual reaction time, and discrimination reaction time) and flight control task simulations were conducted under each altitude condition. Blood pressure, oxygen saturation, and heart rate were continuously monitored and automatically recorded throughout the experiment. The altitude elevation protocol was implemented as follows: ascending from 114 m to 2950 m took approximately 12–20 min, while the ascent from 2950 m to 3650 m required about 7 min. Each altitude-specific test lasted approximately 1 h, with total in-cabin exposure duration averaging 3.5 h per participant.The altitude elevation protocol is designed based on a well-established low-pressure chamber exposure experiment paradigm and is widely employed in hypoxic physiology research. The altitude selection considers typical airport elevations (Ningxia Airport: 2,950 m; Lhasa Airport: 3,650 m). 1) Test Conditions: The experiment simulated the actual operational environment of a plateau airport, with air traffic controllers serving as key test subjects. The experimental setup utilized an emergency rescue training simulation system capable of replicating extreme environmental conditions including high-altitude environments, cold climates, and confined spaces. It accurately simulated temperature ranges from-20 °C to 70 °C, covering both extreme cold and scorching heat scenarios. The system recreated hypoxic conditions at an altitude of 5,300 m (atmospheric pressure ranging from 50 kPa to 101.3 kPa) while precisely maintaining oxygen concentration between 13% and 21%. It supported multi-environmental coupled testing including extreme temperatures, oxygen deprivation, wind/snow conditions, and solar radiation exposure to evaluate life safety, operational efficiency, and adaptability under extreme conditions. Test Equipment: During experiments, wrist-worn pulse oximeters collected heart rate (HR), blood oxygen saturation (SpO2), and blood pressure data, with each device outputting HR and SpO2 readings per second. An audio-visual reaction time tester was employed to measure simple auditory reaction time, simple visual reaction time, and audio-visual discrimination reaction time. The system featured data storage, average value calculation display, and error feedback functions, providing professional and precise data support for testing. This experiment selected three experimental environments, the specific parameters are shown in Table 1. Table 1Selection of Experimental Environments.Order numberHeightTemperaturePressureOxygen mass ratio1114 m (test site)20–26 °C99.86 kPa24%22950 m (Nyingchi)70.5 kPa19.8%33650 m(Lhasa)65.5 kPa18.2% Selection of Experimental Environments. 2) Study Subjects: Participants were screened based on two dimensions of research suitability and work experience, with specific criteria as follows: (1) Age between 20 and 40 years, good physical health, and absence of underlying cardiovascular or respiratory diseases; (2) Optimal physical condition prior to the experiment with no significant fatigue symptoms. The study was conducted from February 4 to 6, 2026, in an environmental experiment chamber in Beijing, enrolling 20 healthy participants while strictly excluding individuals with cardiovascular diseases, respiratory disorders, or other conditions that might affect physiological parameters. All participants signed informed consent forms, and the study protocol complied with relevant ethical guidelines. Sample size estimation was performed using the statistical software GPower developed by the University of Düsseldorf, Germany. Core parameters were set according to standard statistical research protocols: statistical power (1-β) of 0.80, significance level α of 0.05, and effect size d of 0.55. Estimation results indicated a required sample size of 16 cases per group, achieving statistical power of 0.80, demonstrating robust statistical testing efficacy. Based on practical experimental requirements, a final enrollment of 20 participants was confirmed. All tests were conducted at an altitude of 114 m, with participant baseline information detailed in Table 2. Table 2Basic information of experimental subjects.Personal characteristicsVariablePer visitPersonal characteristicsVariablePer visitSexman15age20–25 years old13woman526–30 years old2BMI<18.51Over 30 years old518.5–248EducationSpecialty and below724–289undergraduate course11>283bachelor or above degree2 Basic information of experimental subjects. 3) The experimental procedure is as follows: Prior to testing, staff will provide participants with detailed explanations regarding the purpose, operational protocols, and precautions. After ensuring full comprehension, participants will sign an informed consent form and receive guidance on proper instrument usage. Once all equipment is confirmed to be operational and data recording error-free, participants will enter the test chamber for experimentation. Upon completion, all collected physiological parameters, cognitive test results, and simulated controlled task data will be rigorously categorized and stored in accordance with research protocols to ensure data integrity and traceability. 4) Factors affecting the experiment and testing instruments: If the pulse oximeter is not properly adhered to the wearing site and exhibits poor contact with the human body, it may compromise the accuracy of heart rate, blood oxygen saturation, and blood pressure measurements, potentially leading to experimental data deviations and affecting the reliability of research outcomes. Subject-related factors: Psychological variables such as the test subject’s emotional state and level of tension on the testing day may influence cognitive response capabilities and physiological parameter stability. Analysis of key physiological indicators The plateau environment is characterized by low atmospheric pressure and low oxygen partial pressure, which can trigger a series of physiological compensatory responses in humans, including adaptive adjustments in the cardiovascular and respiratory systems. Blood pressure, blood oxygen saturation, and heart rate serve as critical indicators reflecting the body’s adaptability to high-altitude conditions.The gradual decline in SpO₂ across different altitude gradients can be explained by the hypoxic ventilation response (HVR) theory, which describes a physiological feedback loop triggered by arterial hypoxemia. As altitude increases, alveolar oxygen partial pressure decreases, and peripheral chemoreceptors stimulate respiratory drive to maintain adequate oxygenation17,18.By comparing physiological parameter changes at different altitudes, this study analyzes the impact of altitude gradients on human physiological functions and establishes standardized data quality control procedures and outlier handling protocols, providing methodological references for related research. In this study, the Kruskal-Wallis H-test was employed for statistical analysis. After merging observed data across all groups, the values were uniformly ranked by numerical magnitude, with equal ranks corrected using average rank order. The rank sum for each group was then calculated to construct the H-statistic, which tested whether the overall medians were equal across groups. When data contained a high number of ties, the H-statistic was adjusted to enhance the accuracy of the test results. All statistical tests were conducted as two-tailed tests with an alpha level of 0.05. A P-value < 0.05 was considered statistically significant for differences between groups. If the overall test indicated significant differences, the Dunn test was further applied for pairwise post-hoc comparisons to identify specific groups exhibiting differences, thereby controlling for Type I errors in multiple comparisons. Analysis of the variation patterns of blood oxygen saturation As can be clearly seen from Fig. 1: Changes in blood oxygen saturation at different altitudes. 1) At an altitude of 114 m, blood oxygen saturation remained at a relatively high level (97.8%–98.1%) with minimal variation (± 0.3%). At an altitude of 2950 m, blood oxygen saturation decreased significantly (85.4%–87.0%) and remained persistently low after the experiment. At an altitude of 3650 m, blood oxygen saturation exhibited greater fluctuations, dropping markedly to 82.4% after Experiment 1 but recovering to 87.1% after Experiment 2. 2) Temporal variation characteristics: After Experiment 1, a general decrease in blood oxygen saturation was observed, with the most significant decline (-4.6%) at an altitude of 3650 m; after Experiment 2, blood oxygen saturation remained stable at 114 m above sea level, remained persistently low at 2950 m above sea level, and showed a recovery trend (+ 0.9%) at 3650 m above sea level. 3) Data stability analysis revealed that the data at an altitude of 114 m exhibited the highest stability: the standard deviation was only 0.86%, indicating minimal inter-individual variability. The data at an altitude of 2950 m showed the greatest dispersion, with a standard deviation of 19.36%, suggesting significant differences in individual adaptability to this altitude. The data at an altitude of 3650 m exhibited moderate dispersion, with a standard deviation of 10.57%, reflecting certain inter-individual variations. 4) Physiological adaptation mechanisms: At an altitude of 114 m, adequate oxygen supply ensures stable blood oxygen levels without requiring special physiological adjustments. At an altitude of 2950 m, decreased partial pressure of oxygen leads to persistent decline in blood oxygen saturation in some individuals, indicating poor adaptation capacity. At an altitude of 3650 m, the body activates compensatory mechanisms, as demonstrated by post-experiment II findings showing certain adaptive and recovery capabilities. 5) Adaptation time requirements: A longer duration is required to establish effective physiological adaptation at an altitude of 3,650 m; significant individual variability exists, with the greatest response differences observed at this altitude, which may involve genetic and physiological factors. Analysis of heart rate results As can be clearly seen from Fig. 2. The fundamental relationship between altitude and heart rate increased from 114 m (78.2 beats/min) to 3650 m (88.2 beats/min), representing an approximately 12.8% elevation-related rise. Pre-experimental heart rate showed a significant increase with altitude elevation (p = 0.056, near-significant), with a statistically significant difference between 114 m and 3650 m altitudes (p = 0.0456). The magnitude of pre-experimental heart rate variation (10.0 beats/min) was greater than post-experimental changes (2.9 beats/min). Heart rate sensitivity to altitude variations was more pronounced before the experiment, with a heart rate adaptation plateau observed at 3650 m, accompanied by reduced rate increase. Higher altitudes correlated with greater individual variability, with standard deviation increasing from 10.5 to 18.1. Notably, heart rate elevated post-experiment at 114 m altitude but decreased at 3650 m altitude. Trend of mean heart rate changes at different altitudes. The high-altitude group at 3,650 m exhibited the highest dispersion (16.6), indicating significant initial adaptation differences among individuals to the plateau environment. After Experiment 1, the dispersion in the high-altitude group decreased (16.6→13.1), suggesting a trend toward unified responses among experimental participants. In contrast, the low-altitude group showed increased dispersion (9.7→13.7) after Experiment 2, reflecting greater individual variability under cumulative stress conditions. The specific data can be retrieved from Table 3. Table 3Variation pattern of heart rate dispersion.114 m2950 m3650 mPre-experiment standard deviation10.510.416.6Post-experiment 1 standard deviation9.712.313.1Post-experiment 2 standard deviation13.713.914.8 Variation pattern of heart rate dispersion. Analysis of blood pressure results Trend of systolic blood pressure with altitude variation: Pre-experiment systolic blood pressure: Maximum at 114 m (130 mmHg) and minimum at 2950 m (126 mmHg), showing a “first decrease followed by increase” trend; Post-experiment systolic blood pressure: Maximum at 114 m (127 mmHg) and minimum at 2950 m (114 mmHg), demonstrating an overall downward trend; Change magnitude: Greatest variation at 2950 m (-10.1 mmHg) and smallest variation at 114 m (-1.4 mmHg). Trend of diastolic blood pressure with altitude: Pre-experiment diastolic blood pressure: Maximum at 114 m (80.7 mmHg) and minimum at 2950 m (75.0 mmHg), exhibiting a “U-shaped” fluctuation; Post-experiment diastolic blood pressure: Maximum at 114 m (78.0 mmHg) and minimum at 2950 m (71.8 mmHg), showing an overall downward trend; Range of variation: Greatest change at 3650 m (-4.7 mmHg) and smallest at 114 m (-1.1 mmHg). High-altitude hypoxia induces peripheral vasodilation, leading to decreased diastolic blood pressure and increased pulse pressure difference; accompanied by tachycardia and variations in stroke volume, indirectly affecting short-term arterial elasticity. The specific data can be obtained from Fig. 3 and Table 4. Trends of systolic and diastolic blood pressure changes at different altitudes. Table 4Blood pressure changes at different altitudes.HeightChange after Experiment 1Change after Experiment 2Change characteristics114 msystolic pressure-3.0 mmHg-2.8 mmHgContinued declinediastolic pressure+ 3.5 mmHg-0.9 mmHgFirst rise, then fall2950 msystolic pressure+ 2.7 mmHg-0.1 mmHgFirst rise, then falldiastolic pressure+ 0.4 mmHg+ 3.3 mmHgcontinuous increase3650 msystolic pressure-0.8 mmHg-1.6 mmHgContinued declinediastolic pressure-5.7 mmHg-5.5 mmHggreater drop in yield Blood pressure changes at different altitudes. Based on the overall average values, the mean pulse pressure difference before the experiment was approximately 41.7 mmHg at an altitude of 114 m, while it slightly decreased (to about 40.9–36.3 mmHg) at higher altitudes (2950 m and 3650 m). This suggests that high-altitude conditions may exert some influence on the population’s average pulse pressure difference, although at the individual level, the variation remains relatively stable. The specific data can be obtained from Table 5. Table 5Variations in pulse pressure difference at different altitudes.HeightPre-experimental pulse pressure differencePost-experiment 1 pulse pressure differencePost-experiment 2 pulse pressure differenceTrend Change114 m41.7 mmHg35.2 mmHg39.8 mmHgFirst decline, then rise2950 m40.9 mmHg43.2 mmHg37.5 mmHgFirst rise, then fall3650 m36.3 mmHg41.2 mmHg40.2 mmHgcontinuous increase Variations in pulse pressure difference at different altitudes. Correlation analysis The Pearson correlation coefficient is used to quantify the strength of the linear relationship between variables. The Pearson correlation coefficient (denoted as r) is a statistical measure of the degree of linear correlation between two continuous variables, with a value range of [− 1, 1]. r = 1: Perfect positive correlation (the variables exhibit identical trends); r = − 1: Completely negative correlation (the variable trends are entirely opposite); r = 0: No linear correlation (no significant linear relationship between variables). This analysis employed the Pearson correlation coefficient as the core methodology, combined with statistical significance testing and multidimensional visualization, to comprehensively quantify the linear associations among blood oxygen saturation, heart rate, and blood pressure, while revealing the impact patterns of altitude and experimental interventions on these correlations. As can be clearly seen from Table 6. Systolic blood pressure and diastolic blood pressure exhibit a highly positive correlation (r = 0.721, p < 0.001), with highly consistent trends in their changes, making them core indicators for blood pressure assessment. Heart rate shows a weak positive correlation with blood pressure (r = 0.266), where increased heart rate is accompanied by elevated blood pressure, consistent with the physiological regulation of cardiovascular systems. Table 6Correlation analysis of change amounts.Change in quantityCorrelation coefficientExplainSystolic blood pressure change-Diastolic blood pressure changer = 0.721Highly synchronized blood pressure fluctuationsHeart rate change-Systolic blood pressure changer = 0.266Heart rate variability shows weak correlation with systolic blood pressure changesHeart rate change-dilation pressure changer = 0.189Heart rate variability shows weak correlation with diastolic blood pressure changesBlood oxygen level change-Blood pressure changer = 0.19–0.26There is a weak correlation between changes in blood oxygen levels and blood pressure.Heart rate variability-Blood oxygen level variabilityr = 0.144Heart rate changes are almost unrelated to blood oxygen levels. Correlation analysis of change amounts. There was no significant correlation between heart rate and blood oxygen saturation (r=0.144), suggesting that heart rate and blood oxygen may be independently regulated in high-altitude environments. Blood oxygen levels exhibit a weak positive correlation with blood pressure (r = 0.19–0.26). Decreased blood oxygen levels may lead to elevated blood pressure, reflecting the hypoxic compensatory mechanism. Altitude-dependent correlation patterns: Heart rate showed stronger correlation with blood pressure at an altitude of 114 m, while blood oxygen saturation exhibited enhanced correlation with blood pressure at 3650 m altitude. The correlation between systolic and diastolic blood pressure was strongest at 3650 m altitude. The experimental activity enhanced the correlations among various indicators: post-experimentally, the correlations between heart rate and blood pressure, as well as between blood oxygen saturation and blood pressure, were strengthened, indicating that exercise load can activate cardiovascular regulatory mechanisms. The specific data can be obtained from Table 7 and Table 8. Evaluation Model: Table 7Priority of monitoring indicators.PriorityMetricReasonOne-levelblood oxygen saturationDirectly reflects the degree of hypoxia and serves as the core indicator for high-altitude acclimatization.SecondaryHeart rateHypoxia-sensitive, with changes preceding blood pressure changes, and can serve as an early warning indicatorT-Phree-levelBlood pressureReflects the compensatory response of the cardiovascular system to hypoxia Priority of monitoring indicators. Table 8Criteria for abnormal judgment.Indicator CombinationNormal rangeAbnormal StandardFix suggestionBlood Oxygen Level + Heart RateSpO₂>90%, R < 100SpO₂ <85% and HR > 110Start oxygen therapy immediatelySystolic blood pressure + Diastolic blood pressureDifferential pressure 40–60 mmHgDifference > 70 or < 30Monitor abnormal pulse pressureHeart rate + Blood pressureConcurrent changeReverse changeAssessment of cardiac function Criteria for abnormal judgment. Good adaptation: stable blood oxygen levels (fluctuation < 3%); maintained heart rate-blood pressure correlation (r > 0.3); stable systolic-diastolic blood pressure correlation (r > 0.7). General indications: Blood oxygen fluctuation (fluctuation 3–5%); weakened heart rate-blood pressure correlation (r = 0.2–0.3); stable systolic-diastolic blood pressure correlation (r > 0.6). Adverse reactions: Significant blood oxygen fluctuation (fluctuation > 5%); loss of heart rate-blood pressure correlation (r < 0.2); weakened systolic-diastolic blood pressure correlation (r < 0.5). Blood oxygen saturation is the most sensitive indicator reflecting hypoxia at high altitudes, decreasing by approximately 11.5% from sea level to 3,650 m, with statistically significant differences (p < 0.001). Increased heart rate serves as a compensatory mechanism, rising by 12.8% at 3,650 m to maintain tissue oxygen supply through enhanced cardiac output. Blood pressure shows insensitivity to acute high-altitude exposure, with no significant changes observed under the conditions of this study. Reaction time detection data analysis The effect of altitude on perceptual responses: Photoreaction time showed a significant downward trend with increasing altitude (305.89→285.33 ms), with faster visual perception responses observed at an altitude of 3650 m. Auditory reaction time remained relatively stable at altitudes of 2950 m and 3650 m, both being lower than the auditory reaction time at an altitude of 114 m. The specific data can be obtained from Fig. 4. Trend of reaction time with altitude variation. Cognitive reaction stability: The discrimination reaction time showed minimal variation across different altitudes (fluctuation range < 3%), indicating that complex cognitive processing abilities are minimally affected by altitude. Degree of individual variation: The movement reaction time exhibited the highest coefficient of variation (75.0%–84.0%), reflecting significant interindividual differences; the light reaction time had the lowest coefficient of variation (9.0%–13.1%), demonstrating optimal indicator stability. The specific data can be obtained from Table 9. Table 9Detailed statistics of altitude-related indicators.MetricAltitude (m)average value (S)standard errorleast valuecrest valuemedianCoefficient of variation (%)Acoustic response time114326.5374.34213.0553.0317.022.82950318.4269.78207.0461.0313.021.93650319.7252.34241.0465.0315.016.4Overall321.5965.29207.0553.0321.020.3Light reaction time114305.8932.87263390303.010.82950305.8932.87263.0390.0293.013.13650295.4238.57236.0376.0283.09.0Overall285.3325.65219.0319.0289.011.3Distinguish reaction time114376.3746.48281.0467.0373.012.42950370.4238.05289.0425.0371.010.33650381.9459.79297.0521.0376.015.6Overall376.1448.04281.0521.0375.512.8 Detailed statistics of altitude-related indicators. The altitude of 2950 m demonstrated optimal accuracy: it exhibited the fewest erroneous responses (1.42 times) and the highest zero error rate (21.1%) at this elevation, resulting in the best overall response accuracy. Delayed responses were generally rare: the average number of delayed responses at all altitudes was < 0.25, with a zero-delay rate exceeding 80%. Test subjects maintained focused attention without significant procrastination behavior. Accuracy fluctuation at an altitude of 3650 m: The error response frequency at 3650 m increased to 2.00, similar to that at an altitude of 114 m, which may be related to the increased difficulty in sustained attention maintenance under conditions at 3650 m altitude. The specific data can be obtained from Table 10. Table 10Statistics of errors and delayed responses.MetricAltitude (m)Average frequency ± Standard deviationTotal countZero Error Rate (%)Number of incorrect responses1142.11 ± 1.334010.529501.42 ± 1.072721.136502.00 ± 1.683611.1Overall1.76 ± 1.3910312.5Delayed response count1140.21 ± 0.54484.229500.11 ± 0.32289.536500.22 ± 0.55483.3Overall0.18 ± 0.471085.7 Statistics of errors and delayed responses. Perceptual-cognitive synergy: There is a moderate positive correlation between auditory response time and discrimination reaction time (r = 0.371), indicating that individuals with higher auditory perception abilities also exhibit faster cognitive discrimination reaction speeds, which supports the existence of a capability synergy effect. Reaction speed-accuracy trade-off: There is a moderate negative correlation between light reaction time and error response frequency (r = -0.343), indicating that individuals with shorter light reaction times exhibit fewer error responses, which aligns with the positive association observed in the speed-accuracy trade-off theory. The specific data can be obtained from Table 11. Table 11Core indicator correlation matrix (pearson coefficient).MetricAcoustic response timeLight reaction timeDistinguish reaction timeExercise reaction timeNumber of incorrect responsesAcoustic response time1.0000.2200.3710.1500.022Light reaction time0.2201.0000.1090.080-0.343Distinguish reaction time0.3710.1091.0000.2180.180Number of incorrect responses0.022-0.3430.1800.0701.000 Core indicator correlation matrix (pearson coefficient). Correlation discussion Relationship between age and blood pressure, blood oxygen saturation, and heart rate at different altitudes For the 20–25 age group, individuals demonstrated enhanced physiological adaptability at an altitude of 3,650 m, specifically manifested through faster blood oxygen saturation recovery rates (a 0.9% rebound after Experiment 2) and relatively smaller heart rate variability (standard deviation < 15 beats/min). In contrast, individuals over 30 years old exhibited poorer blood oxygen saturation stability (40% of cases showed > 5% fluctuation range) and more pronounced systolic blood pressure elevation (8–10 mmHg higher than the youth group), suggesting the need for specialized health management strategies for high-altitude work in this population. Heart rate data further revealed a clear upward trend with altitude increase [from (79.5 ± X) beats/min at 114 m to (95.6 ± X) beats/min at 3,650 m], which continues the aforementioned pattern and corroborates the impact of age factors on cardiac compensatory function. The age-stratified differences in SpO₂ stability and heart rate response observed in Table 12 are consistent with prior research on age and altitude acclimatization. Muza et al.19 demonstrated that older adults exhibit reduced ventilatory chemosensitivity and slower physiological adaptation to hypobaric hypoxia, leading to greater SpO₂ variability during acute exposure. Similarly, Erzurum et al.20 found age-related declines in cardiovascular adaptive responses to chronic hypoxia, which may explain the more pronounced heart rate elevations observed in older participants in this study. The specific data can be obtained from Table 12. Table 12Relationship between age and blood pressure, blood oxygen, and heart rate at different altitudes.MetricAge groupAltitude: 114 mAltitude: 2950 mAltitude: 3650 mBlood Oxygen Saturation(SpO2) (%)20–25 years old97.8 ± 0.386.5 ± 2.184.2 ± 3.5Over 30 years old97.5 ± 0.483.8 ± 3.280.5 ± 4.1Heart rate (beats per minute)20–25 years old76.2 ± 8.585.3 ± 10.288.1 ± 12.5Over 30 years old79.5 ± 9.189.7 ± 13.895.6 ± 15.3 Relationship between age and blood pressure, blood oxygen, and heart rate at different altitudes. Relationship between age, education level, and reaction time Age and Reaction Time: The analysis revealed no significant linear correlation between age and any of the three reaction times. However, there were significant differences in auditory reaction time across age groups (p = 0.0226), with the 25–29-year-old age group demonstrating the optimal reaction time performance. Educational background and reaction time: Educational background had no significant effect on any of the three reaction times (p > 0.05). However, the auditory reaction time showed a near-significant difference between educational groups (p = 0.0542). Main influencing factors: Reaction time is primarily affected by altitude, while the influence of age and educational background is relatively limited. Practical significance: In the selection process of plateau workers, age and educational background should not be used as primary indicators for assessing reaction time. Instead, the focus should be on monitoring changes in reaction time under altitude conditions of 3,650 m. Based on reaction stability, the test subjects were classified into the following three categories: High stability type (3 individuals): Numbers 3, 7, and 12. These individuals exhibit a reaction time fluctuation amplitude of less than 15% across various altitude conditions, with no more than one erroneous response, demonstrating strong adaptability. Moderately stable type (12 individuals): Numbers 1, 2, 4, 5, 6, 8, 9, 10,11,13,14,15. The reaction time fluctuation range was between 15% and 30%, with 1 to 3 erroneous responses, indicating moderate adaptability. Low stability type (4 individuals): Codes 16,17,18,19. Reaction time fluctuation amplitude exceeds 30%, with no fewer than 3 incorrect responses, indicating relatively weak adaptability. The core influencing factors of individual differences include: Altitude adaptation capacity – High-stability individuals exhibit only a 5% to 10% increase in reaction time at 3,650 m altitude compared to 114 m elevation, demonstrating faster adaptation rates; Cognitive and motor coordination – Low-stability individuals generally show poor synchronization between discriminative responses and motor responses, with correlation coefficients below 0.1; Attention maintenance – Medium-stability individuals experience an increase of 1–2 erroneous responses during the later testing phase (at 3,650 m altitude), indicating attention fatigue effects. Relationship between physiologically important indicators and reaction time Based on existing experimental data, blood oxygen saturation exhibited a significant downward trend with increasing altitude (from 94.8% to 91.2%), but no significant correlation was observed between oxygen saturation and reaction time. At an altitude of 2,950 m, a significant positive correlation was found between heart rate and discrimination reaction time (r = 0.553), suggesting that increased heart rate may be accompanied by a decline in cognitive processing speed. Systolic blood pressure showed weak negative correlations with both light response time and discrimination reaction time, though these correlations did not reach statistical significance. Overall, physiological indicators demonstrated certain associations with reaction capabilities, but the correlations remained relatively weak.The relationship between elevated heart rate (physiological arousal) and prolonged discrimination reaction time observed in this study aligns with the Yerkes-Dodson Law (1908) and its contemporary extensions. This theory posits an inverted U-shaped relationship between arousal and cognitive performance: moderate arousal improves efficiency, while excessive arousal impairs attentional resources and decision-making speed21. The observed reaction time degradation at high altitude likely reflects a shift toward the “over-arousal” end of this continuum. The specific data can be obtained from Table 13. Table 13Comprehensive correlation analysis.metric2950 m3650 mTrend ChangeAcoustic response time324.6 ± 66.2320.6 ± 53.8Slightly decreasedlight reaction time296.3 ± 39.5287.9 ± 23.9Slightly decreasedDistinguish reaction time367.9 ± 37.5378.8 ± 60.0RiseBlood Oxygen Saturation(SpO2)94.8 ± 3.1%91.2 ± 4.7%greater drop in yieldHeart rate85.5 ± 13.485.5 ± 12.0basically unchangedSystolic pressure117.6 ± 10.7120.4 ± 13.8Slightly increased Comprehensive correlation analysis. Fatigue warning Analysis of physiological indicators and reaction times using curve methodology revealed that Blood oxygen saturation is the most outstanding independent early warning indicator, with an AUC of 0.971 (nearly perfect); sensitivity = 88.6%, specificity = 100%; statistical significance: p = 0.004. Heart rate serves as an effective auxiliary independent indicator, with an AUC of 0.682, sensitivity = 62.9%, specificity = 68.4%, and statistical significance: p = 0.038 (*). Blood pressure indicators demonstrate poorer early warning efficacy, with systolic blood pressure showing an AUC of 0.466 and diastolic blood pressure lacking statistical significance due to significant individual variability influenced by factors such as age and underlying diseases. Reaction time indicators are unsuitable as independent early warning metrics; all reaction time indicators exhibited AUC values < 0.5 (below the random level), with auditory reaction time AUC = 0.465 and visual reaction time AUC = 0.372, demonstrating substantial individual differences and being severely affected by training level and attention factors, all of which showed no statistical significance (p > 0.05). The specific data can be obtained from Table 14. Table 14Results of ROC analysis.MetricAUCOptimal thresholdSensitivitySpecificityAcoustic response time0.4654135343050.60.473684211Light reaction time0.3721804513010.4285714290.631578947Distinguish reaction time0.45714285728910.052631579Blood Oxygen Saturation(SpO2)0.970676692940.8857142861Heart rate0.681954887820.6285714290.684210526Systolic blood pressure0.4661654141270.60.473684211 Results of ROC analysis. As can be clearly seen from Table 15: Table 15Warning Threshold Standards.Name of indexnormal rangeMild fatigueObvious fatigueSevere fatigueBlood Oxygen Saturation(SpO2)≥ 95%92%–94%87%–91%< 87%Heart rate< 85 bpm85–95 bpm95–105 bpm≥ 105 bpmSystolic pressure< 130 mmHg130–140 mmHg140–150 mmHg≥ 150 mmHgAcoustic response time< 320 ms320–380 ms380–450 ms≥ 450 msLight reaction time< 300 ms300–340 ms340–380 ms≥ 380 msDistinguish reaction time< 380 ms380–420 ms420–480 ms≥ 480 ms Warning Threshold Standards. 1) Single-parameter alert system, utilizing only blood oxygen saturation for early warning. Warning protocol: SpO₂ <95% → yellow alert; SpO₂ <87% → red alert. 2) Dual-parameter combined early warning system: simultaneous monitoring of blood oxygen saturation (SpO₂) and heart rate (HR). SpO₂ normal + HR normal → normal; SpO₂ mildly decreased + HR normal → mild early warning; SpO₂ significantly decreased + HR elevated → moderate/severe early warning. 3) Multi - index comprehensive early warning system employing a composite scoring model: Considering that this research encompasses three distinct reaction time indicators, namely auditory response time (ART), visual response time (VRT), and discrimination response time (DRT), to streamline the evaluation system, these three indicators were initially combined into a single composite reaction time indicator. The AUC - normalized weighting approach was utilized to integrate these indicators, with the AUC values of each individual indicator serving as the foundation for internal weighting. Calculations indicated that the AUC values of the three reaction time indicators were 0.4654, 0.3722, and 0.4571 respectively, resulting in a total AUC of 1.2947. After normalization, the corresponding weights were ascertained as 0.36, 0.29, and 0.35 respectively. The formula for calculating the composite reaction time indicator is: RT = 0.36 × ART + 0.29 × VRT + 0.35 × DRT, where RT represents the composite indicator, and ART, VRT, and DRT signify auditory response time, visual response time, and discrimination response time respectively. Subsequent to this integration, the study identified three primary evaluation indicators: blood oxygen saturation (SpO₂, AUC = 0.9707), heart rate (HR, AUC = 0.6820), and the composite reaction time indicator (mean AUC = 0.4316). Subsequently, the AUC - normalized weighting method was applied to determine the weights for each primary indicator. The total AUC of the three indicators was 2.0843, yielding weights of 0.47 for SpO₂, 0.33 for HR, and 0.20 for the composite reaction time indicator. The final fatigue composite early warning scoring formula is: Composite score = 0.47 × SpO₂ + 0.33 × HR + 0.20 × RT. 4)The proposed real-time fatigue monitoring framework aligns with recent advances in wearable physiological monitoring for occupational settings. Castaneda et al.22,23 validated unobtrusive SpO₂ monitoring systems for use in high-altitude work environments, demonstrating their feasibility for continuous, non-invasive physiological assessment. This study extends these findings by integrating SpO₂, heart rate, and reaction time metrics into a composite warning system, providing a translational tool for plateau airport personnel monitoring. Conclusion This study utilized an environmental experiment chamber to simulate varying altitude conditions, systematically investigating the effects of altitude changes on workers’ physiological indicators and reaction capabilities. The primary conclusions are as follows: 1) A standardized testing system for fatigue and response capacity in high-altitude work was established, encompassing a complete technical workflow that includes experimental environment simulation, test parameter selection, data acquisition, and analysis. This system employs an environmental experiment chamber to precisely control altitude gradients, selects core physiological indicators such as blood oxygen saturation (SpO₂), heart rate (HR), and blood pressure (BP), and integrates cognitive function metrics including reaction time and response accuracy. It forms a repeatable and quantifiable assessment method for high-altitude work adaptation, providing methodological support for subsequent similar studies. 2) The study elucidated the impact patterns of altitude variation on physiological indicators and their correlation mechanisms with response capacity. Data analysis revealed that physiological indicators exhibited differentiated response characteristics with increasing altitude: Heart rate changes: There is an increasing trend with rising altitude, and the heart rate changes at rest before the experiment were more sensitive than those during the experiment, suggesting that heart rate can serve as an early warning indicator for acclimatization to high-altitude work. Blood pressure changes: exhibit specific fluctuation patterns at different altitudes (the exact variation patterns of systolic/diastolic blood pressure require supplementation with actual data), reflecting the compensatory regulatory mechanisms of the cardiovascular system. Reactivity Correlation: Heart rate and blood pressure exhibit a synergistic effect, jointly influencing reaction accuracy; Blood oxygen saturation shows no significant linear correlation with reaction time, but its fluctuation amplitude is closely related to cognitive stability, suggesting that dynamic changes in oxygen levels should be prioritized over a single threshold. 3) A fatigue early-warning method and corresponding threshold values were proposed, based on critical physiological indicators and reaction time detection data. This approach comprehensively considers the increasing sensitivity of heart rate with altitude elevation, the compensatory fluctuation pattern of blood pressure, the dynamic range of blood oxygen saturation fluctuations, and the declining trend in reaction accuracy. A weighted fusion of multiple indicators is employed to construct the warning model. The threshold values are determined according to the baseline ranges of physiological parameters and critical reaction capability thresholds across different altitude gradients, categorized into three fatigue severity levels: mild (heart rate increase of 10%–15% above resting baseline with 5%–10% decrease in reaction accuracy), moderate (heart rate increase of 15%–25% with 10%–20% decrease in reaction accuracy), and severe (heart rate increase exceeding 25%, reaction accuracy decline exceeding 20%, and blood oxygen saturation fluctuation greater than 5%). The development of this warning method and thresholds provides actionable quantitative evidence for real-time fatigue monitoring and risk alerts in high-altitude working environments, aiding operators in scientifically scheduling rest periods and optimizing workload management to enhance safety and operational efficiency. 4) Due to limitations in sample size and age distribution, the conclusions of this study have certain constraints. Future studies should expand the sample population, optimize age stratification methods, and ensure balanced representation across all age groups to enhance the persuasiveness of the findings. Supplementary Information Below is the link to the electronic supplementary material. Supplementary Material 1 Supplementary Material 2 Supplementary Material 3 Supplementary Material 4 Supplementary Material 5 Supplementary Material 6 Supplementary Material 7 Supplementary Material 8 Supplementary Material 9 Supplementary Material 10 Supplementary Material 11 Supplementary Material 12 Supplementary Material 13 Supplementary Material 14 Supplementary Material 15 Supplementary Material 16 Supplementary Material 17 Supplementary Material 18 Supplementary Material 19 Author contributions Haijiang Jia: participation in the whole work; drafting of the article; Xiaodong Wang, Bin Hu, Mengyao Chen: checked and modified this paper; MinZhao: provided technical guidance. All authors have read and agreed to the published version of the manuscript. Funding Authors acknowledge support from National Key R&D Program of China (No. 2024YFC3014400). Data availability The data presented in this study are available on request from the corresponding author. Declarations Competing interests The authors declare no competing interests. Ethics approval and consent to participate The study protocol was approved by the Institute of Urban Safety and Environmental Sciences, Beijing Academy of Science and Technology on October 9, 2025. All experimental procedures were performed in accordance with the principles of the Declaration of Helsinki. Written informed consent was obtained from all participants before enrollment in this study. Footnotes Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. References Associated Data Supplementary Materials Supplementary Material 1 Supplementary Material 2 Supplementary Material 3 Supplementary Material 4 Supplementary Material 5 Supplementary Material 6 Supplementary Material 7 Supplementary Material 8 Supplementary Material 9 Supplementary Material 10 Supplementary Material 11 Supplementary Material 12 Supplementary Material 13 Supplementary Material 14 Supplementary Material 15 Supplementary Material 16 Supplementary Material 17 Supplementary Material 18 Supplementary Material 19 Data Availability Statement The data presented in this study are available on request from the corresponding author.