Cryoextraction for Airway Bleeding After Valve-in-Valve Procedure Authors: Teresa Bretones del Pino, Vicente F Alcalde Martínez, Joaquín Sánchez Gila, Rocío García Orta, Alberto Caballero Vázquez, José Luis Zunzunegui Martínez, Eduardo Molina Navarro Published: 2026 ABSTRACT AbstractBackgroundHemoptysis after percutaneous valve implantation is a rare but life-threatening complication.Case SummaryAn 84-year-old woman with prior mechanical aortic and biological tricuspid valve replacements presented with tricuspid stenosis and regurgitation. A transcatheter valve-in-valve procedure using a 24.5-mm Myval was performed successfully. However, she developed severe hemoptysis, hypoxia, and ventilation difficulties shortly after the procedure. Flexible bronchoscopy with cryoprobe-assisted clot extraction was performed, removing large obstructive clots from the bronchi. A second cryoextraction was necessary 72 hours later. The patient improved rapidly, was extubated, and was discharged in stable condition after 7 days.DiscussionCryoextraction is commonly used for tumor-related airway bleeding and foreign body removal, but its application in postvalve implantation hemoptysis is novel. This case highlights its lifesaving role.Take-Home MessageCryoextraction can be a safe and effective alternative when conventional bleeding control methods fail after valve implantation.Key words: clot extraction, cryoprobe, hemoptysis, hypoxemia, pulmonary bleeding, valve replacement, tricuspid valve-in-valve History of Presentation An 84-year-old woman with a history of mechanical aortic valve replacement and a surgically implanted biological tricuspid valve (23-mm Edwards PM) presented with symptomatic severe tricuspid stenosis and regurgitation (Figure 1, Video 1). She underwent a planned percutaneous valve-in-valve implantation using a 24.5-mm Myval valve (Meril Lifesciences) through a 24-F DrySeal sheath (Gore Medical; selected because of severe tortuosity and extensive calcification of the iliofemoral access, which made advancement of the prosthetic valve technically challenging) using a Lunderquist guidewire. The procedure was initially successful, with good hemodynamic and echocardiographic results (Figure 2, Videos 2 to 4). However, shortly after valve deployment, the patient developed sudden and severe hemoptysis through the endotracheal tube, accompanied by oxygen desaturation and difficulty in ventilation. Transthoracic Echocardiography Before Intervention (A) Parasternal long-axis view of the tricuspid valve showing severe regurgitation. (B) Parasternal short-axis view. (C) Apical 4-chamber view demonstrating severe transprosthetic regurgitant flow. (D) Apical 4-chamber view with proximal isovelocity surface area (PISA) assessment. (E) Measurement of the effective regurgitant orifice area using the PISA method. (F) Elevated transvalvular gradient. Percutaneous Intervention: Transcatheter Valve-In-Valve (A to D) Imaging of 24.5-mm Myval valve-in-valve implantation. (A) Internal diameter of the bioprosthetic tricuspid valve. (B) Positioning of the Myval transcatheter valve within the surgical bioprosthesis. (C) Balloon inflation for valve deployment. (D) Final postimplantation result. (E to H) Transesophageal echocardiography findings. (E) Baseline severe tricuspid regurgitation. (F) Three-dimensional en face view showing passage of the Lunderquist guidewire across the valve. (G) Biplanar projection during balloon inflation of the prosthetic valve. (H) Final position of the implanted Myval valve. At that point, distal lobar artery perforation was suspected as the underlying cause (Figures 3B and 3C). Angiographic studies were performed but failed to identify the exact bleeding site (Video 5). Therefore, standard percutaneous hemostatic maneuvers were attempted. Initially, a prolonged inflation was performed with a 6-mm balloon proximal to the lobar artery where the stiff guidewire had been positioned (Figure 3E), without success. Subsequently, a more proximal prolonged inflation was carried out in the left lower lobar trunk using a 12-mm balloon (Figure 3F), and anticoagulation was reversed with protamine, acknowledging the risk of thrombosis of the mechanical aortic prosthesis implanted in the patient. Complication: Hemoptysis and Initial Hemostatic Management (A) Blood clots observed in the left bronchial tree. (B) Left lobar artery angiography without evidence of active bleeding. (C) Suspected perforation of the left lower lobar artery by the Lunderquist guidewire. (D) Hemostasis using a 6-mm balloon in the left lower lobar artery. (E) Conventional bronchoscopy showing clots in the left bronchus. (F) Additional hemostasis with a 12-mm balloon in the left pulmonary artery. (G) Fluoroscopy with contrast instillation into the right bronchus. (H) Balloon dilation performed in the right bronchus. Although several maneuvers were performed to treat a presumed arterial branch bleeding—without angiographic evidence—the patient showed persistent hemodynamic instability. This prompted evaluation for alternative bleeding sources, and fluoroscopy began to reveal mobile high-density material within the bronchial tree, raising suspicion of active airway bleeding, possibly exacerbated by high-dose procedural heparinization (Video 6). The anesthesiologists and intensivists performed a fiberoptic bronchoscopy to try to aspirate the blood clots, but they occupied the entire bronchial lumen (Figure 3G). A bronchography was then performed to try to delimit the clots, their location and size (injection of 30% contrast through the endotracheal tube), and we tried to break the clots up with a balloon to clear the bronchial lumen (Figure 3H). Despite all these maneuvers, the patient's ventilation continued to deteriorate, with respiratory acidosis and desaturation, so a pulmonary specialist was urgently consulted in the catheterization laboratory, and flexible bronchoscopy was performed, revealing large blood clots obstructing both bronchi. Given the suspicion of ongoing airway bleeding and the presence of obstructive clots, a flexible bronchoscopy was performed using a cryoprobe, a device capable of reaching temperatures below −75 °C. This technique, more commonly used for endobronchial lesion ablation or foreign body extraction,1,2 was employed in this context to perform cryoextraction of the endobronchial clots.3 Upon application of the cryoprobe, the clots adhered to the probe tip through rapid freezing and were removed en bloc from both bronchi (Figure 4). This immediate intervention led to significant clinical improvement: The patient's gas exchange parameters normalized, and ventilatory dynamics stabilized. Cryoextraction of Obstructive Clot From the Left Main Bronchus (A) Complete occlusion of the left main bronchial lumen by a large clot. (B) The 2.4-mm cryoprobe used during the procedure and the extracted clot. (C) Recanalization of the left main bronchus after successful cryoextraction. Given the initial suspicion of pulmonary arterial bleeding, the 12-mm balloon was intentionally maintained inflated at the level of the left lobar artery branch despite the absence of angiographic or fluoroscopic evidence of active bleeding. After clinical stabilization, the balloon was removed without evidence of bleeding, and the procedure was concluded. The patient was subsequently admitted to the intensive care unit, where she remained under close observation for 72 hours. During her stay in the intensive care unit, a follow-up chest computed tomography scan revealed residual clots in the airways (Figure 5). A second bronchoscopy with cryoextraction was performed, successfully removing the remaining material (Figure 6). After this second intervention, the patient continued to improve and was extubated without complications. She was discharged from the hospital in stable condition just 7 days after the procedure, after confirmation of a normally functioning tricuspid prosthesis by transthoracic echocardiography (Video 7). Chest Computed Tomography Angiography After Catheterization Opacification of the left lower lobe bronchus and several of its segmental branches by blood material, causing complete obstructive atelectasis of the left lower lobe. No signs of active bleeding after contrast administration. Small right-sided pleural effusion. Second Cryoextraction Guided by Computed Tomography Angiography (A to C) Cryoextraction of a large endobronchial blood clot using a cryoprobe during flexible bronchoscopy. (D and E) Large clots removed from both bronchi. Discussion This case illustrates a rare but serious complication of transcatheter valve-in-valve implantation. Postprocedure hemoptysis is often managed with balloon tamponade or embolization. However, in this case, these measures were unsuccessful, and the patient presented with airway bleeding and hemodynamic compromise. In such situations, cryoextraction of airway clots using a flexible cryoprobe proved effective and lifesaving while the primary bleeding was being addressed. Cryotherapy is typically reserved for tumor ablation, biopsies, or foreign body removal in pulmonary procedures. Its novel use here for clot extraction due to lobar artery injury is outside current guideline-based practices, making it a noteworthy case for consideration in future procedural complication management. Conclusions Flexible bronchoscopy with cryoextraction should be considered as a safe, rapid, and effective option for severe airway bleeding after structural cardiac interventions when other methods are not feasible or unsuccessful. Clot Cryoextraction in Postprocedural Hemoptysis ICU = intensive care unit. Funding Support and Author Disclosures Dr Zunzunegui Martínez is a proctor for Myval. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose. Take-Home Messages •Cryoextraction is a powerful technique for managing airway clots due to postprocedural hemoptysis. Cryoextraction is a powerful technique for managing airway clots due to postprocedural hemoptysis. •In rare cases such as valve-related airway bleeding, it can be a lifesaving tool when conventional methods fail. In rare cases such as valve-related airway bleeding, it can be a lifesaving tool when conventional methods fail. Footnotes The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center. Appendix For supplemental videos, please see the online version of this paper. Appendix Video 1 Preintervention Echocardiography (A) Parasternal long-axis view: severe tricuspid regurgitation. (B) Parasternal short-axis view: same findings. (C) Apical 4-chamber view: transprosthetic flow and regurgitation. (D) Apical 4-chamber view: PISA estimation. (E) Tricuspid regurgitation orifice area by PISA. (F) Elevated transvalvular gradient. Video 2 Fluoroscopic View of the Myval Prosthesis “Valve-in-Valve” Immediately After Implantation Video 3 Fluoroscopic View (Left) Myval valve-in-valve well seated relative to the previous valve and functioning normally. (Right) Mechanical aortic valve with preserved disc mobility. Video 4 Transesophageal Echocardiography Interventional Study (A) Baseline tricuspid regurgitation. (B) Three-dimensional frontal view: guidewire passage. (C) Multiplanar projection: transprosthetic catheter passage. (D) Biplanar view: balloon inflation. (E) Prosthesis deployed. (F) Postimplantation: transvalvular flow without residual regurgitation. Video 5 Fluoroscopic Angiography of the Left Pulmonary Artery With No Active Bleeding Observed. Video 6 Bleeding Can Be Seen as Mobile High-Density Areas Within the Left Bronchus Video 7 Postoperative Transthoracic Echocardiography (A) Parasternal long-axis view of the tricuspid valve. (B) Apical 4-chamber view: tricuspid prosthesis in place. (C) Transvalvular flow without regurgitation. References Associated Data Supplementary Materials Video 1 Preintervention Echocardiography (A) Parasternal long-axis view: severe tricuspid regurgitation. (B) Parasternal short-axis view: same findings. (C) Apical 4-chamber view: transprosthetic flow and regurgitation. (D) Apical 4-chamber view: PISA estimation. (E) Tricuspid regurgitation orifice area by PISA. (F) Elevated transvalvular gradient. Video 2 Fluoroscopic View of the Myval Prosthesis “Valve-in-Valve” Immediately After Implantation Video 3 Fluoroscopic View (Left) Myval valve-in-valve well seated relative to the previous valve and functioning normally. (Right) Mechanical aortic valve with preserved disc mobility. Video 4 Transesophageal Echocardiography Interventional Study (A) Baseline tricuspid regurgitation. (B) Three-dimensional frontal view: guidewire passage. (C) Multiplanar projection: transprosthetic catheter passage. (D) Biplanar view: balloon inflation. (E) Prosthesis deployed. (F) Postimplantation: transvalvular flow without residual regurgitation. Video 5 Fluoroscopic Angiography of the Left Pulmonary Artery With No Active Bleeding Observed. Video 6 Bleeding Can Be Seen as Mobile High-Density Areas Within the Left Bronchus Video 7 Postoperative Transthoracic Echocardiography (A) Parasternal long-axis view of the tricuspid valve. (B) Apical 4-chamber view: tricuspid prosthesis in place. (C) Transvalvular flow without regurgitation.