Correction: Exercise intensity influences variability and test-retest reliability of pulmonary gas-exchange measurements during constant work-rate cycling Authors: Alessandro L. Colosio, Massimo Teso, Maura Loi, Lena Stuer, Jan Boone, Silvia Pogliaghi Published: 2026 The approximation symbol (∼) was inadvertently rendered as a minus sign (−) in four instances. A correction has been made to the Discussion section, Paragraph 3. The corrected sentence is as follows: “Most prior studies examined either a single outcome such as V̇O2max (40), device (41) or a specific intensity/protocol (42), and have reported device-related errors generally ranging from ∼1%–8% depending on the system, protocol, exercise intensity, and analytical approach (17–19, 42–44), with some studies reporting even values up to 12% (44).” A correction has been made to the Discussion section, Paragraph 4. The corrected sentence is as follows: “Specifically, variability was most evident in V̇O2 and V̇E at M1 and M2, where fluctuations across days appeared larger in relative terms (e.g., up to ∼350 mL·min−1 difference in V̇O2 and ∼15 L·min−1 in V̇E for some individuals).” A correction has been made to the Discussion section, Paragraph 6. The corrected sentence is as follows: “SEM values followed the same pattern, ranging from ∼60 to ∼140 mL·min−1 for V̇O2, depending on intensity and device.” A correction has been made to the Discussion section, Paragraph 7. The corrected sentence is as follows: “These thresholds indicate that physiological changes not exceeding ∼250–400 mL·min−1 should be interpreted with caution, especially when other forms of bias are present (e.g., non-blind study designs).” Some grammatical issues were identified in the published version. A correction has been made to the section Methods, “Protocol”, Paragraph 1. The corrected sentence is as follows: “Each CWR started with 1 min of seated rest on the ergometer, followed by 3 min unloaded cycling at 30 revolutions per minute (rpm) performed to standardise the exercise onset.” A correction has been made to the section Methods, “Protocol”, Paragraph 2. The corrected sentence is as follows: “Participants were instructed to maintain their habitual physical activity patterns throughout the study period and were informally monitored regarding changes in training routine besides the testing sessions.” A correction has been made to the section Methods, “Ramp incremental test”, Paragraph 3. A sentence was duplicated: “These values were used to determine the intensities of successive tests.” The first occurrence has been deleted. A correction has been made to the Discussion section, Paragraph 3. The corrected sentence is as follows: “In this context, simulator-based studies and repeated human exercise studies address partially different questions, as the latter additionally incorporate biological variability.” The original version of this article has been updated.