Transmission electron microscopy of cultured cells: Optimized protocols for ultrastructural studies and post-embedding immunogold labeling Authors: Anna Richert, Robert Lenartowski, Jolanta Nowak, Piotr Wasąg, Marta Lenartowska Published: 2026 ABSTRACT AbstractNanometer-scale localization of specific proteins within cells is essential for understanding their roles in diverse physiological and pathological cellular processes. Such high-resolution localization of protein epitopes can be achieved by combining transmission electron microscopy (TEM) with immunogold labeling. Several immuno-TEM approaches are available, including pre-embedding and post-embedding techniques, each offering distinct advantages and limitations when applied to cultured cells. One of the major challenges is preparation of cell culture samples embedded in resin in a manner that enables reliable ultrathin sectioning and efficient collection of sections. Here, we describe an optimized post-embedding immunogold labeling procedure for the localization of one or more proteins in both adherent and non-adherent cells cultured on plastic coverslips. This approach has been successfully applied in our previous studies and proved suitable for routine ultrastructural immunolabeling of cultured cells. Although the protocol is designed to achieve an optimal balance between the preservation of cellular ultrastructure and antigenicity, optimal results may still depend on the specific characteristics of the proteins under investigation and their localization within particular cellular compartments. Therefore, we also present a complementary procedure for the ultrastructural analysis of cultured cells that can support and extend immuno-TEM investigations. Introduction Immunogold transmission electron microscopy (immuno-TEM) combines the localization of specific proteins using antibodies with detailed visualization of cellular ultrastructure. This approach is therefore essential for understanding how proteins function in diverse cellular processes, including gene expression, cell signaling, motility, and intracellular trafficking. Notably, immuno-TEM remains one of the best morphological techniques providing sufficient spatial resolution to allow precise localization of proteins within nuclear and cytoplasmic compartments, as well as to evaluate their association with the nucleus, cellular organelles, or cytoskeletal structures. Several immuno-TEM strategies have been developed, including post-embedding and pre-embedding approaches, each offering specific advantages and limitations. In post-embedding protocols, samples are typically fixed with a relatively weak fixative (usually 4% formaldehyde, as recommended for immunocytochemistry), embedded in a low-viscosity resin, and sectioned into ultrathin sections [1, 2]. Immunolabeling is then performed on the sections using conventional gold-conjugated antibodies with particle sizes typically ranging from 5 to 30 nm. In contrast, pre-embedding protocols involve initial fixation with formaldehyde followed by membrane permeabilization (usually with Triton X-100) and immunostaining using ultrasmall gold conjugates (approximately 0.8–1.4 nm), which are subsequently visualized by silver or gold enhancement [2, 3]. The samples are then post-fixed with a strong cross-linking fixative (typically 1%–2% glutaraldehyde and 1%–2% osmium tetroxide), embedded in epoxy resin, and sectioned into ultrathin sections. While the post-embedding approaches generally provide stronger and more accessible immunolabeling, pre-embedding methods are superior in preserving cellular ultrastructure. Both immuno-TEM strategies theoretically allow the simultaneous detection of multiple antigens in cells by using primary antibodies raised in different species, which can then be visualized with species-specific secondary antibodies. In practice, however, the post-embedding immunogold method enables more precise co-localization of two distinct protein epitopes by using gold particles of different sizes (e.g. 10 and 20 nm) to label species-specific secondary antibodies (from different animals) that bind to corresponding primary antibodies. In the pre-embedding approach, double labeling is achieved by sequential incubation with species-specific ultrasmall gold conjugates. First, samples are incubated with the first ultrasmall gold conjugate, followed by silver or gold enhancement, and then with a second ultrasmall gold conjugate, followed by additional silver or gold enhancement [4]. This procedure is expected to generate two distinct populations of particles: smaller particles that have undergone a single round of enhancement and larger particles that have undergone two rounds of enhancement. In practice, however, the signal amplification process used in both single- and double-labeling pre-embedding immunogold procedures frequently produces particles of intermediate size [4, 5]. The presence of these heterogeneous gold-silver particles complicates reliable discrimination of labeling signals and makes accurate co-localization of multiple antigens within cells difficult. Nevertheless, the pre-embedding immunogold labeling approach remains widely used in TEM studies of cultured cell lines [6, 7]. However, one of the major technical challenges in both pre- and post-embedding approaches is the preparation of resin-embedded cell culture samples that consistently yield high-quality ultrathin sections and allow their efficient collection for subsequent immunocytochemical analyses. To overcome these limitations, we developed a post-embedding immunogold labeling protocol optimized for studies of cultured cells [8, 9]. This approach enabled efficient immunolabeling of non-adherent PC12 neurosecretory cells in vitro, allowing precise determination of the subcellular localization of protein epitopes within the cytoplasm and nucleus, as well as within distinct cytoplasmic subdomains, including the endoplasmic reticulum, secretory vesicles, and clathrin-coated pits, and nuclear subdomains such as the nuclear envelope, interchromatin granules, and nucleolus. Here, we describe a detailed protocol for single- and double-immunogold labeling applicable to both adherent and non-adherent cells cultured in vitro (Fig. 1), complemented by a procedure for ultrastructural analysis of investigated cells that can support and extend immuno-TEM studies (Fig. 2). In our experience, the principal technical challenge is obtaining high-quality ultrathin sections of cultured cells suitable for TEM analysis. To address this challenge, we provide a detailed graphical workflow that guides the user through the entire sample-preparation process, from establishing a cell monolayer on plastic coverslips, through fixation, resin embedding, and block trimming, to ultrathin sectioning (Fig. 3). By enabling the reliable preparation of high-quality ultrathin sections from cultured cells, this protocol facilitates routine ultrastructural and immunogold analyses in diverse experimental models. The methodology described here is applicable to numerous cell lines and allows the localization of cellular components at a resolution that exceeds the limits of confocal microscopy. Post-embedding immuno-TEM analysis of in vitro cultured cells. Semithin sections of Sol8 (a) and PC12 (b) cells stained with methylene blue reveal distinct morphologies of adherent and non-adherent cell monolayers, respectively. Immunogold labeling demonstrates the presence of myosin VI in both the cytoplasm (c, e, f) and the nucleus (c–e, g, h). In the cytoplasm, myosin VI localizes to the perinuclear region (c, e) as well as to the cell periphery (e, f), where gold particles are frequently observed in close proximity to electron-dense granules (f, arrow heads). Within the nucleus, myosin VI is predominantly detected at the periphery of dense chromatin (c–e, arrow heads) and within the interchromatin space (d, g). Gold particles associated with myosin VI are also present in the nucleolus (d). Double immunogold labeling (h) of myosin VI (red arrows indicate large colloidal gold particles) and SC35 ( arrows indicate small colloidal gold particles) confirms the presence of both proteins within the interchromatin space. Cy, cytoplasm; Dfc, dense fibrillar component; Fc, fibrillar center; Gc, granular component; No, nucleolus; Nu, nucleus. Scale bar 3 µm (a, b); 500 nm (c–h). Ultrastructure of in vitro cultured cells. Semithin sections of Sol8 (a, a′) and PC12 (b, b′) cells stained with methylene blue reveal distinct morphologies of adherent and nonadherent cell monolayers, respectively. Notably, fixation with glutaraldehyde provides superior preservation and improved microscopic appearance of cytochemically stained sections compared with formaldehyde fixation (compare Figs 1 and 2), resulting in excellent ultrastructural preservation of both Sol8 (c) and PC12 (d) cells. Ultrastructural analysis enables the identification of nuclear domains, including the nucleolus with its subcomponents, chromatin, and nuclear bodies (e, f), as well as cytoplasmic organelles such as mitochondria and endoplasmic reticulum (h). Various types of vesicles are also observed, including electron-dense granules (g, h, arrows). Cy, cytoplasm; Dfc, dense fibrillar component; Fc, fibrillar center; Gc, granular component; Mi, mitochondria; Nb, nuclear body; No, nucleolus; Nu, nucleus; rER, rough endoplasmic reticulum; sER, smooth endoplasmic reticulum. Scale bar 1 µm (a, b); 5 µm (a′, b′); 500 nm (c–h). Graphical protocol for preparing ultrathin sections of in vitro cultured cells for ultrastructural and immunocytochemical analyses. Materials Cell lines The Sol8 cell line [10], an adherent mouse skeletal muscle cell line that serves as a model of oxidative skeletal muscle differentiation and function (American Type Cell Culture Collection, ATCC, CRL-2174). The Sol8 cell line [10], an adherent mouse skeletal muscle cell line that serves as a model of oxidative skeletal muscle differentiation and function (American Type Cell Culture Collection, ATCC, CRL-2174). The non-adherent variant of PC12 cell line [11], derived from a rat gland tumor (pheochromocytoma), widely used as a model system in neuroscience for investigating neuronal differentiation (American Type Cell Culture Collection, ATCC, CRL-1721). The non-adherent variant of PC12 cell line [11], derived from a rat gland tumor (pheochromocytoma), widely used as a model system in neuroscience for investigating neuronal differentiation (American Type Cell Culture Collection, ATCC, CRL-1721). General solutions and reagents Culture media dedicated to cell line Culture media dedicated to cell line Dulbecco’s Phosphate Buffered Saline (PBS) × 10 stock solution (Merck, D1048) Dulbecco’s Phosphate Buffered Saline (PBS) × 10 stock solution (Merck, D1048) Sterile trypsin-EDTA × 10 in PBS (Biowest, X0930) Sterile trypsin-EDTA × 10 in PBS (Biowest, X0930) Poly-D-lysine (Merck, P6407) Poly-D-lysine (Merck, P6407) Poly-L-Lysine 0.1% solution in H2O (Merck, P8920) Poly-L-Lysine 0.1% solution in H2O (Merck, P8920) Gibco™ Horse Serum, heat-inactivated (Thermo Fisher Scientific, 26050088) Gibco™ Horse Serum, heat-inactivated (Thermo Fisher Scientific, 26050088) Gibco™ Fetal Bovine Serum, heat-inactivated (Thermo Fisher Scientific, 10270106) Gibco™ Fetal Bovine Serum, heat-inactivated (Thermo Fisher Scientific, 10270106) Antibiotic Antimycotic Solution (100×), Stabilized (Merck, A5955) Antibiotic Antimycotic Solution (100×), Stabilized (Merck, A5955) Gibco™ Trypan Blue solution 0.4% (Thermo Fisher Scientific, 15250061) Gibco™ Trypan Blue solution 0.4% (Thermo Fisher Scientific, 15250061) Ethyl alcohol, pure ≥ 99.5% (Merck, 459844) Ethyl alcohol, pure ≥ 99.5% (Merck, 459844) Glutaraldehyde solution 25% in H2O (Merck, G5882) Glutaraldehyde solution 25% in H2O (Merck, G5882) Osmium tetroxide solution 2% in H2O (Merck, 75633) Osmium tetroxide solution 2% in H2O (Merck, 75633) Formaldehyde solution 16% in H2O, methanol-free (Polysciences, 18814) Formaldehyde solution 16% in H2O, methanol-free (Polysciences, 18814) Propylene oxide, pure ≥99.9% (Polysciences, 00236) Propylene oxide, pure ≥99.9% (Polysciences, 00236) Poly/Bed® 812 Embedding Kit/BDMA (Polysciences, 21844) Poly/Bed® 812 Embedding Kit/BDMA (Polysciences, 21844) LR White Medium Grade Kit (Electron Microscopy Sciences, 14380) LR White Medium Grade Kit (Electron Microscopy Sciences, 14380) Liquid nitrogen Liquid nitrogen Bovine Serum Albumin (BSA) heat shock fraction, pH 7, pure ≥98% (Merck, A9647) Bovine Serum Albumin (BSA) heat shock fraction, pH 7, pure ≥98% (Merck, A9647) Glycine, pure ≥99.9% (Merck, G8898) Glycine, pure ≥99.9% (Merck, G8898) Primary antibodies (species-specific) Primary antibodies (species-specific) Secondary antibodies conjugated to colloidal gold 10, 15 and 20 nm (species-specific) Secondary antibodies conjugated to colloidal gold 10, 15 and 20 nm (species-specific) Uranyl acetate (Electron Microscopy Sciences, 22400) Uranyl acetate (Electron Microscopy Sciences, 22400) Lead citrate 3% (Electron Microscopy Sciences, 22410) Lead citrate 3% (Electron Microscopy Sciences, 22410) Sodium hydroxide pellets, pure ≥97.0% (Merck, 221465) Sodium hydroxide pellets, pure ≥97.0% (Merck, 221465) Methylene blue (Polysciences, 04220) Methylene blue (Polysciences, 04220) Ultrapure H2O (18.2 MΩ·cm, Milli·Q grade; sterile or non-sterile, as required) Ultrapure H2O (18.2 MΩ·cm, Milli·Q grade; sterile or non-sterile, as required) Accessories 35 and 60 mm sterile plastic Petri dishes 35 and 60 mm sterile plastic Petri dishes 60 mm sterile glass Petri dishes 60 mm sterile glass Petri dishes 12-well sterile plastic tissue culture plates 12-well sterile plastic tissue culture plates 13 mm diameter sterile Nunc™ Thermanox™ plastic coverslips (Thermo Fisher Scientific, 174950) 13 mm diameter sterile Nunc™ Thermanox™ plastic coverslips (Thermo Fisher Scientific, 174950) Sterile Pasteur 3 ml plastic pipettes (serological pipettes) Sterile Pasteur 3 ml plastic pipettes (serological pipettes) Sterile glass Pasteur pipettes Sterile glass Pasteur pipettes Sterile serological pipettes 10 ml Sterile serological pipettes 10 ml Automatic pipettes and sterile tips Automatic pipettes and sterile tips Sterile 15 and 50 ml disposable plastic conical tubes Sterile 15 and 50 ml disposable plastic conical tubes Pointed-tip tweezers Pointed-tip tweezers Anti-magnetic fine-point tweezers Anti-magnetic fine-point tweezers Diamond stylus Diamond stylus 5 ml glass vials 5 ml glass vials 5 ml conical plastic tubes with caps 5 ml conical plastic tubes with caps Capsule embedding mold Capsule embedding mold Razor blades and syringe needles Razor blades and syringe needles Microscopy slides Microscopy slides Parafilm® M Parafilm® M Hexagonal 200-mesh copper grids Hexagonal 200-mesh copper grids Hexagonal 200-mesh nickel grids Hexagonal 200-mesh nickel grids Kimtech® wipe-tissue paper Kimtech® wipe-tissue paper Equipment Laminar flow cabinet with HePa filters Laminar flow cabinet with HePa filters CO2 tissue culture incubator CO2 tissue culture incubator High-temperature incubator High-temperature incubator Freezer Freezer Fume hood Fume hood Horizontal or vertical shaker Horizontal or vertical shaker Vacuum aspirator Vacuum aspirator Counting chamber for cell quantification or automated cell counter Counting chamber for cell quantification or automated cell counter Laboratory centrifuge Laboratory centrifuge Ultramicrotome and diamond knife for ultrasectioning Ultramicrotome and diamond knife for ultrasectioning Inverted phase-contrast microscope Inverted phase-contrast microscope Stereoscopic microscope Stereoscopic microscope Light microscope Light microscope Transmission electron microscope Transmission electron microscope Methods Prepare all solutions using ultrapure water (H2O MQ) and analytical grade reagents. Store all reagents at room temperature unless otherwise specified. All steps should be performed under sterile conditions, as in standard in vitro cell culture procedures. Dispose of all waste materials in accordance with applicable institutional and governmental regulations. Preparation of the Nunc™ Thermanox™ plastic coverslips Using a diamond stylus, asymmetrically mark the uncoated side of the Nunc™ Thermanox™ plastic coverslips (the side not intended for cell seeding) to ensure correct orientation in subsequent steps. Using a diamond stylus, asymmetrically mark the uncoated side of the Nunc™ Thermanox™ plastic coverslips (the side not intended for cell seeding) to ensure correct orientation in subsequent steps. Using pointed-tip tweezers, place the coverslips in a 60 mm Petri dish with the marked surface facing down. Using pointed-tip tweezers, place the coverslips in a 60 mm Petri dish with the marked surface facing down. Apply approximately 150 µL of 0.1% poly-L-lysine (or poly-D-lysine) to each coverslip and incubate overnight at room temperature. Apply approximately 150 µL of 0.1% poly-L-lysine (or poly-D-lysine) to each coverslip and incubate overnight at room temperature. Aspirate the poly-lysine solution from coverslips using sterile glass Pasteur pipettes connected to a vacuum line, and wash three times with sterile H2O MQ, aspirating the wash solution after each rinse. Aspirate the poly-lysine solution from coverslips using sterile glass Pasteur pipettes connected to a vacuum line, and wash three times with sterile H2O MQ, aspirating the wash solution after each rinse. Allow the coverslips to air dry, then sterilize them by UV irradiation for 60 min. Allow the coverslips to air dry, then sterilize them by UV irradiation for 60 min. Note 1: All steps should be carried out under sterile conditions in a laminar flow cabinet. Note 2: Select the size of the Nunc™ Thermanox™ plastic coverslips according to the diameter of the resin embedding mold (for samples prepared for ultrastructural studies) or the cap of 5 ml conical plastic tubes (for samples prepared for immunocytochemistry). Note 3: For adherent cells, Nunc™ Thermanox™ coverslips should be sufficient for growth. For other cell types, the plastic surface may need to be coated with poly-L-lysine (or poly-D-lysine) before seeding. Cell culture and plating cells on the Nunc™ Thermanox™ plastic coverslips Plate 2 × 106 (PC12) or 1 × 105 (Sol8) cells in a 60 mm culture dish containing 5 ml of appropriate culture medium. Plate 2 × 106 (PC12) or 1 × 105 (Sol8) cells in a 60 mm culture dish containing 5 ml of appropriate culture medium. Incubate at 37°C in a humidified atmosphere with 5% CO2 (in CO2 incubator) until ∼70% to 80% (PC12) or ∼50% to 60% (Sol8) confluence is reached (typically 3 days), monitoring daily with an inverted phase-contrast microscope. Incubate at 37°C in a humidified atmosphere with 5% CO2 (in CO2 incubator) until ∼70% to 80% (PC12) or ∼50% to 60% (Sol8) confluence is reached (typically 3 days), monitoring daily with an inverted phase-contrast microscope. Aspirate the medium from the culture dish with a vacuum line. Aspirate the medium from the culture dish with a vacuum line. Detach the cells using a method appropriate for the specific cell type. For example, incubate cells with 1 ml of 0.25% trypsin-EDTA for 5 min at room temperature, then neutralize the enzyme by adding 4 ml of culture medium and detach the cells by rinsing the cell layer with a gentle stream of medium using a serological pipette. Detach the cells using a method appropriate for the specific cell type. For example, incubate cells with 1 ml of 0.25% trypsin-EDTA for 5 min at room temperature, then neutralize the enzyme by adding 4 ml of culture medium and detach the cells by rinsing the cell layer with a gentle stream of medium using a serological pipette. Transfer 5 ml of detached cell suspension to a sterile 15 ml conical centrifuge tube and centrifuge at 700 × g for 8 − 10 min at room temperature. Transfer 5 ml of detached cell suspension to a sterile 15 ml conical centrifuge tube and centrifuge at 700 × g for 8 − 10 min at room temperature. Carefully remove the supernatant with a vacuum line (do not aspirate the cell pellet). Carefully remove the supernatant with a vacuum line (do not aspirate the cell pellet). Using an automatic pipette, gently resuspend the cell pellet in 1 ml of culture medium. Determine the cell concentration by Trypan Blue staining (using the counting chamber or automated cell counter) and dilute the cells with the culture medium to a final concentration of 2 × 105 (PC12 cells) or 8 × 104 (Sol8 cells). Using an automatic pipette, gently resuspend the cell pellet in 1 ml of culture medium. Determine the cell concentration by Trypan Blue staining (using the counting chamber or automated cell counter) and dilute the cells with the culture medium to a final concentration of 2 × 105 (PC12 cells) or 8 × 104 (Sol8 cells). Using sterile tweezers, place Nunc™ Thermanox™ coverslips individually into a 12-well tissue culture plate or a 30 mm Petri dish (ensure that the poly-lysine-coated surface is facing up). Carefully dispense drops of the cell suspension (150 µl) onto the surface of the poly-lysine–coated coverslips, ensuring the droplets remain within the edges of the coverslips. Using sterile tweezers, place Nunc™ Thermanox™ coverslips individually into a 12-well tissue culture plate or a 30 mm Petri dish (ensure that the poly-lysine-coated surface is facing up). Carefully dispense drops of the cell suspension (150 µl) onto the surface of the poly-lysine–coated coverslips, ensuring the droplets remain within the edges of the coverslips. After 6–8 h (PC12 cells) or 3 h (Sol8 cells) incubation at 37°C with 5% CO2 (to allow cell adhesion), add an appropriate volume of culture medium and incubate the plate/dish at 37°C in a humidified atmosphere with 5% CO2 until ∼70% to 80% confluency is reached (typically 1–2 days), monitoring daily with an inverted phase-contrast microscope. After 6–8 h (PC12 cells) or 3 h (Sol8 cells) incubation at 37°C with 5% CO2 (to allow cell adhesion), add an appropriate volume of culture medium and incubate the plate/dish at 37°C in a humidified atmosphere with 5% CO2 until ∼70% to 80% confluency is reached (typically 1–2 days), monitoring daily with an inverted phase-contrast microscope. Note 1: The Sol8 adherent cells were cultured in high glucose DMEM (Merck, D6429), supplemented with 20% fetal bovine serum and 1/100 volume of Antibiotic Antimycotic solution. Note 2: The non-adherent variant of PC12 cells were cultured in Gibco™ RPMI 1640 media (Thermo Fisher Scientific, 52400025) supplemented with 10% heat inactivated horse serum, 5% heat inactivated fetal bovine serum, and 1/100 volume of Antibiotic Antimycotic solution. Note 3: High cell density can alter physiological state and morphology; therefore, cells intended for fixation and subsequent analysis should be maintained at appropriate confluence. However, high confluency (∼70% to 80%) of the cell monolayer is strongly recommended, particularly for immunocytochemistry samples, as cells fixed on Nunc™ Thermanox™ without postfixation in osmium tetroxide are not visible. Cell fixation and sample preparation for ultrastructural studies All steps should be performed at room temperature, except the sample polymerization step. Wash the cells on Nunc™ Thermanox™ coverslips in 1 × PBS buffer (pH 7.2) three times for 30–60 s each. Wash the cells on Nunc™ Thermanox™ coverslips in 1 × PBS buffer (pH 7.2) three times for 30–60 s each. Fix the cells with 2% glutaraldehyde in 1 × PBS for 30–60 min, followed by three washes in 1 × PBS (10 min each) and two washes in H2O MQ (5 min each). Fix the cells with 2% glutaraldehyde in 1 × PBS for 30–60 min, followed by three washes in 1 × PBS (10 min each) and two washes in H2O MQ (5 min each). Post-fix the cells with 1% osmium tetroxide in H2O MQ for 30 min, followed by two washes with H2O MQ (5 min each). Post-fix the cells with 1% osmium tetroxide in H2O MQ for 30 min, followed by two washes with H2O MQ (5 min each). Using pointed-tip tweezers transfer Nunc™ Thermanox™ coverslips into 5 ml glass vials and dehydrate cells using a graded ethyl alcohol series: 30% (10 min), 50% (10 min), 70% (15 min), 96% (2 × 10 min), and 100% (2 × 15 min), followed by two 10–min washes with propylene oxide. Using pointed-tip tweezers transfer Nunc™ Thermanox™ coverslips into 5 ml glass vials and dehydrate cells using a graded ethyl alcohol series: 30% (10 min), 50% (10 min), 70% (15 min), 96% (2 × 10 min), and 100% (2 × 15 min), followed by two 10–min washes with propylene oxide. Prepare Poly/Bed® 812 resin according to the manufacturer’s instructions, ensuring an adequate amount for subsequent infiltration (propylene oxide–resin mixtures) and polymerization steps. Prepare Poly/Bed® 812 resin according to the manufacturer’s instructions, ensuring an adequate amount for subsequent infiltration (propylene oxide–resin mixtures) and polymerization steps. Perform infiltration using propylene oxide–resin mixtures: 3:1 solution (30 min), 1:1 (60 min), 1:3 (overnight), and 100% resin (minimum 8 h). All steps should be carried out in 5 ml glass vials using a vertical or horizontal shaker to enhance resin infiltration into the samples. Perform infiltration using propylene oxide–resin mixtures: 3:1 solution (30 min), 1:1 (60 min), 1:3 (overnight), and 100% resin (minimum 8 h). All steps should be carried out in 5 ml glass vials using a vertical or horizontal shaker to enhance resin infiltration into the samples. Apply freshly prepared 100% Poly/Bed® 812 resin with a convex meniscus to the cavities of the capsule embedding mold. It is important to remove any air bubbles after application, e.g. using a toothpick. Apply freshly prepared 100% Poly/Bed® 812 resin with a convex meniscus to the cavities of the capsule embedding mold. It is important to remove any air bubbles after application, e.g. using a toothpick. Carefully remove Nunc™ Thermanox™ coverslips with embedded cells from the glass vials using pointed-tip tweezers. Gently blot the edges of the coverslips on Kimtech® wipe-tissue paper to remove excess resin. Carefully remove Nunc™ Thermanox™ coverslips with embedded cells from the glass vials using pointed-tip tweezers. Gently blot the edges of the coverslips on Kimtech® wipe-tissue paper to remove excess resin. Under a stereoscopic microscope, check the orientation of each coverslip. Ensure that the cells face the resin. Fill 1–2 wells with resin only, as these will serve as controls for the polymerization process. Under a stereoscopic microscope, check the orientation of each coverslip. Ensure that the cells face the resin. Fill 1–2 wells with resin only, as these will serve as controls for the polymerization process. Place the prepared molds in an incubator preheated to 70°C for 48–72 h. After 48 h, check the control resin; if it does not achieved an amber-like consistency, the polymerization can be extended. Place the prepared molds in an incubator preheated to 70°C for 48–72 h. After 48 h, check the control resin; if it does not achieved an amber-like consistency, the polymerization can be extended. Remove the capsules containing the embedded coverslips from the mold and immerse them in liquid nitrogen for 1–2 min to separate the coverslip from the capsule. The embedded cells should be visible on the smooth surface of the capsule, indicating that it is ready for pyramid trimming and sectioning. Remove the capsules containing the embedded coverslips from the mold and immerse them in liquid nitrogen for 1–2 min to separate the coverslip from the capsule. The embedded cells should be visible on the smooth surface of the capsule, indicating that it is ready for pyramid trimming and sectioning. Note 1: Washing in PBS buffer prior to cell fixation should be brief, as prolonged washing may induce stress and alter cell morphology. The optimal washing duration and number of rinses should be determined experimentally. Note 2: Coverslips may float during solution changes; to prevent this, they should be held at the bottom using sterile tweezers or a pipette tip. Aspiration and solution exchange should be performed smoothly to prevent cell drying, whereas solutions should be added gently. Note 3: As glutaraldehyde, OsO4, propylene oxide, and Poly/Bed® 812 resin are toxic, all procedures involving them must be performed in a well–ventilated fume hood with appropriate personal protective equipment (gloves, lab coat, and safety glasses). Note 4: Selection of a biological resin suitable for ultrastructural imaging and exhibiting minimal volume shrinkage during polymerization is critical. Note 5: The wells of the mold should be filled with resin so that Nunc™ Thermanox™ coverslips do not touch each other. Contact between the edges of the coverslips may result in shifting during polymerization, preventing full resin embedding and making them unsuitable for subsequent steps. Cell fixation and sample preparation for immunocytochemical studies All steps should be performed at room temperature (unless otherwise required) with shaking or using a vertical rotor. Wash the cells on Nunc™ ThermanoxTM coverslips in 1 × PBS buffer (pH 7.2) three times for 60 s each. Wash the cells on Nunc™ ThermanoxTM coverslips in 1 × PBS buffer (pH 7.2) three times for 60 s each. Fix the cells with 4% formaldehyde and 0.25% glutaraldehyde in 1 × PBS for 30–60 min, followed by three washes in 1 × PBS (10 min each). Fix the cells with 4% formaldehyde and 0.25% glutaraldehyde in 1 × PBS for 30–60 min, followed by three washes in 1 × PBS (10 min each). Using pointed-tip tweezers, transfer Nunc™ ThermanoxTM coverslips into 5 ml glass vials and wash the cells twice in H2O MQ (5 min each). Next, dehydrate cells using a graded ethyl alcohol series: 30% (10 min), 50% (10 min), 70% (15 min), 96% (2 × 10 min), and 100% (2 × 15 min). Using pointed-tip tweezers, transfer Nunc™ ThermanoxTM coverslips into 5 ml glass vials and wash the cells twice in H2O MQ (5 min each). Next, dehydrate cells using a graded ethyl alcohol series: 30% (10 min), 50% (10 min), 70% (15 min), 96% (2 × 10 min), and 100% (2 × 15 min). Prepare LR White resin according to the manufacturer’s instructions, ensuring an adequate amount for subsequent infiltration (ethyl alcohol–resin mixtures) and polymerization steps. Prepare LR White resin according to the manufacturer’s instructions, ensuring an adequate amount for subsequent infiltration (ethyl alcohol–resin mixtures) and polymerization steps. Perform infiltration using ethyl alcohol–resin mixtures: 3:1 solution (30 min), 1:1 (60 min), 1:3 (overnight), and 100% resin (overnight). All steps should be carried out in 5 ml glass vials using a vertical or horizontal shaker to enhance resin infiltration into the samples. Perform infiltration using ethyl alcohol–resin mixtures: 3:1 solution (30 min), 1:1 (60 min), 1:3 (overnight), and 100% resin (overnight). All steps should be carried out in 5 ml glass vials using a vertical or horizontal shaker to enhance resin infiltration into the samples. Prepare the workstation in advance. After adding the cofactor, LR White resin polymerizes rapidly; to slow this process, work should be performed on ice or in a cold room. Keep the resin continuously on a stirrer. Weigh the cofactor into vials and store on ice, adding the appropriate amount of resin immediately before use. Prepare the workstation in advance. After adding the cofactor, LR White resin polymerizes rapidly; to slow this process, work should be performed on ice or in a cold room. Keep the resin continuously on a stirrer. Weigh the cofactor into vials and store on ice, adding the appropriate amount of resin immediately before use. Carefully remove Nunc™ ThermanoxTM coverslips with embedded cells from the glass vials using pointed-tip tweezers. Gently blot the edges of the coverslips on Kimtech® paper to remove excess resin. Under a stereoscopic microscope, check the orientation of each coverslip. Carefully remove Nunc™ ThermanoxTM coverslips with embedded cells from the glass vials using pointed-tip tweezers. Gently blot the edges of the coverslips on Kimtech® paper to remove excess resin. Under a stereoscopic microscope, check the orientation of each coverslip. Place the coverslip with the cell-free surface against the inside of the 5 ml conical plastic tube cap, then gently position the tube onto the cap. Place the coverslip with the cell-free surface against the inside of the 5 ml conical plastic tube cap, then gently position the tube onto the cap. Using a syringe needle, puncture the tube twice approximately halfway up its height, then gently inject LR White resin containing the cofactor through one of the holes to cover the cells. Prepare a separate tube without coverslip-embedded cells, filled only with resin, to serve as the polymerization control. Using a syringe needle, puncture the tube twice approximately halfway up its height, then gently inject LR White resin containing the cofactor through one of the holes to cover the cells. Prepare a separate tube without coverslip-embedded cells, filled only with resin, to serve as the polymerization control. Seal the punctures with tape and place the tubes upright at −20°C for two weeks. After this period, check whether the control resin has fully polymerized. If the resin remains sticky, keep the samples at −20°C until polymerization is complete. Seal the punctures with tape and place the tubes upright at −20°C for two weeks. After this period, check whether the control resin has fully polymerized. If the resin remains sticky, keep the samples at −20°C until polymerization is complete. After polymerization, the tubes can be brought to room temperature. Once the caps are removed, the plastic coverslips should detach, leaving the cells embedded in the resin. After polymerization, the tubes can be brought to room temperature. Once the caps are removed, the plastic coverslips should detach, leaving the cells embedded in the resin. Remove the capsules from the tubes by cutting the tube walls with a razor blade. Although the embedded cells may not be visible on the smooth surface of the capsules, they are ready for pyramid trimming and sectioning. Remove the capsules from the tubes by cutting the tube walls with a razor blade. Although the embedded cells may not be visible on the smooth surface of the capsules, they are ready for pyramid trimming and sectioning. Note 1: Washing in PBS buffer prior to cell fixation should be brief, as prolonged washing may induce stress and alter cell morphology. The optimal washing duration and number of rinses should be determined experimentally. Note 2: Coverslips may float during solution changes; to prevent this, they should be held at the bottom using pointed-tip tweezers or a pipette tip. Aspiration and solution exchange should be performed smoothly to prevent cell drying, whereas solutions should be added gently. Note 3: As formaldehyde and LR-White resin are toxic, all procedures involving them must be performed in a well–ventilated fume hood with appropriate personal protective equipment (gloves, lab coat, and safety glasses). Note 4: Selection of a biological resin suitable for immunocytochemistry and exhibiting minimal volume shrinkage during polymerization is critical. Note 5: Polymerization of LR White resin must be carried out under anaerobic conditions. Therefore, select an appropriate polymerization container, such as a 5 ml conical plastic tube with a flat cap matching the diameter of the Nunc™ Thermanox™ coverslip. Preparation of semithin and ultrathin sections Initial assessment of cell preservation was performed on semithin sections stained with 1% methylene blue and examined by light microscopy (Figs 1a and b and 2a–b′). Ultrathin sections were subsequently prepared for immunogold labeling (Fig. 1c–h) and ultrastructural analysis (Fig. 2c–h). Trim the resin blocks to form pyramids. Using an ultramicrotome equipped with a diamond knife cut 1–2 semithin sections and collect them on microscopy slides. Trim the resin blocks to form pyramids. Using an ultramicrotome equipped with a diamond knife cut 1–2 semithin sections and collect them on microscopy slides. Apply a drop of stain (e.g. 1% methylene blue) to the sections, incubate for approximately 1 min at 37°C, then rinse with H2O MQ and allow the slides to air dry. Apply a drop of stain (e.g. 1% methylene blue) to the sections, incubate for approximately 1 min at 37°C, then rinse with H2O MQ and allow the slides to air dry. Examine the stained semithin sections by light microscopy; for TEM and immuno-TEM investigations, select samples exhibiting well-preserved cellular morphology. Examine the stained semithin sections by light microscopy; for TEM and immuno-TEM investigations, select samples exhibiting well-preserved cellular morphology. Continue sectioning and collect ultrathin sections of Poly/Bed® 812–embedded cells on copper grids (for ultrastructural analysis) and of LR White–embedded cells on nickel or gold grids (for immunocytochemistry). Continue sectioning and collect ultrathin sections of Poly/Bed® 812–embedded cells on copper grids (for ultrastructural analysis) and of LR White–embedded cells on nickel or gold grids (for immunocytochemistry). For ultrastructural analysis, stain the sections collected on copper grids with 2.5% uranyl acetate (30 min) followed by 0.4% lead citrate (5–10 min) according to standard procedures. For ultrastructural analysis, stain the sections collected on copper grids with 2.5% uranyl acetate (30 min) followed by 0.4% lead citrate (5–10 min) according to standard procedures. Examine the ultrathin sections using a transmission electron microscope. Examine the ultrathin sections using a transmission electron microscope. Note 1: Coated slides may be used to improve section adhesion during staining. Note 2: Perform staining on drops of the solutions placed on Parafilm® M (∼50 to 100 µL), in the dark for uranyl acetate and in the presence of several NaOH pellets for lead citrate. Note 3: A diamond knife (Micro Star Technologies), a Leica UTC ultramicrotome, and a JEOL EM 100 transmission electron microscope were used for TEM imaging. Post-embedding immunogold labeling All steps of immunogold labeling are performed at room temperature on drops of successive solutions placed on Parafilm® M (∼50 to 100 µL for immunolabeling and ∼500 to 1000 µL for washing) and covered with a glass Petri dish. Grids with ultrathin sections are transferred onto drops of the subsequent solutions using anti-magnetic, fine-point tweezers. Incubate the ultrathin sections collected on nickel or gold grids in a blocking solution containing BSA (typically ∼1% to 3%; 3% in this study) in 1 × PBS buffer (pH 7.2) for 5 min. Incubate the ultrathin sections collected on nickel or gold grids in a blocking solution containing BSA (typically ∼1% to 3%; 3% in this study) in 1 × PBS buffer (pH 7.2) for 5 min. Gently blot the edges of the grids on Kimtech® wipe-tissue paper to remove excess blocking solution, then incubate the sections with the primary antibody diluted in 1 × PBS (typical dilution from 1:20 to 1:50; 1:50 in this study) supplemented with BSA (typically ∼0.1% to 1%; 0.3% in this study) for 2 h. Gently blot the edges of the grids on Kimtech® wipe-tissue paper to remove excess blocking solution, then incubate the sections with the primary antibody diluted in 1 × PBS (typical dilution from 1:20 to 1:50; 1:50 in this study) supplemented with BSA (typically ∼0.1% to 1%; 0.3% in this study) for 2 h. For double immunolabeling, incubate the sections with a mixture of the two primary antibodies, each diluted 1:50 in 1 × PBS supplemented with 0.3% BSA (in this study), for 2 h. For double immunolabeling, incubate the sections with a mixture of the two primary antibodies, each diluted 1:50 in 1 × PBS supplemented with 0.3% BSA (in this study), for 2 h. Wash the sections in 1 × PBS buffer (pH 7.2) three times for 5 min each. Wash the sections in 1 × PBS buffer (pH 7.2) three times for 5 min each. Incubate the sections with the appropriate gold-conjugated secondary antibody, diluted 1:100 in 1 × PBS supplemented with BSA (typically ∼0.1% to 1%; 0.1% in this study) for 30 min. Incubate the sections with the appropriate gold-conjugated secondary antibody, diluted 1:100 in 1 × PBS supplemented with BSA (typically ∼0.1% to 1%; 0.1% in this study) for 30 min. For double immunolabeling, incubate the sections with a mixture of the two appropriate gold-conjugated secondary antibodies (with different gold particle sizes), each diluted 1:100 in 1 × PBS supplemented with 0.1% BSA (in this study), for 30 min. For double immunolabeling, incubate the sections with a mixture of the two appropriate gold-conjugated secondary antibodies (with different gold particle sizes), each diluted 1:100 in 1 × PBS supplemented with 0.1% BSA (in this study), for 30 min. Wash the sections in 1 × PBS three times for 3 min each, followed by three washes with H2O MQ (1 min each). Wash the sections in 1 × PBS three times for 3 min each, followed by three washes with H2O MQ (1 min each). Gently blot the edges of the grids on Kimtech® wipe-tissue paper to remove excess H2O MQ, then stain the sections with 2.5% uranyl acetate (30 min) according to standard procedure. Gently blot the edges of the grids on Kimtech® wipe-tissue paper to remove excess H2O MQ, then stain the sections with 2.5% uranyl acetate (30 min) according to standard procedure. Examine the sections using a transmission electron microscope. Examine the sections using a transmission electron microscope. Note 1: It is important to ensure that the grids are incubated with the ultrathin sections facing the drops of each subsequent solution. Transfer the grids to the next drops of solution using fine-point tweezers, handling the grids by their edges. Note 2: The sections can be pretreated with 50 mM glycine in 1 × PBS for 5–10 min at room temperature to enhance immunolabeling efficiency. Note 3: The primary antibody used in this study was a rabbit polyclonal antibody against myosin VI (Proteus, 25-6791). For double immunolabeling, in addition to the myosin VI antibody, a mouse monoclonal antibody against splicing factor SC-35 (Merck, S4045) was also used. Note 4: The secondary antibody used in this study was a 15 nm gold-conjugated anti-rabbit IgG (BB International, EM GAR15 16140). For double immunolabeling, two different secondary antibodies were used: a 20 nm gold-conjugated anti-rabbit IgG (BB International, EM GAR20 13626) and a 10 nm gold-conjugated anti-mouse IgG (BB International, EM GMHL10 4497). Note 5: Immunocytochemical studies require appropriate controls to verify the specificity of primary antibodies (commonly assessed by Western blot analysis) and secondary antibodies; typical negative control involves omitting the primary antibody and incubating the samples in the corresponding antibody dilution buffer instead. Note 6: A diamond knife (Micro Star Technologies), a Leica UTC ultramicrotome, and a JEOL EM 100 transmission electron microscope were used for immuno–TEM imaging.