Simple Superior Inverted Flap Technique with Extended Internal Limiting Membrane Peeling for the Treatment of Large Macular Holes Authors: Beáta Bajdik, Gréta Kemenes, Vipasha Jain, Keith Martin Noronha, Mariann Fodor, Lili Takács Published: 2026 ABSTRACT PurposeTo evaluate the anatomical and functional outcomes of a simplified superior inverted internal limiting membrane (ILM) flap technique with extended ILM peeling for the surgical treatment of large idiopathic macular holes (iMH).Patients and MethodsThis retrospective, non-randomized, interventional consecutive case series included 42 eyes of 40 patients with iMH. Patients were grouped according to the CLOSE study classification: Group 1: large holes (n=19, minimum linear diameter [MLD] >400 to ≤550 µm), Group 2: extra-large holes (n=18, MLD >550 to ≤800 µm), and Group 3: XXL holes (n=5, MLD >800 to ≤1000 µm). The mean follow-up time was 20.63 ± 18.32 months. The primary endpoint was MH closure rate. Secondary outcomes included closure type, changes in best-corrected visual acuity (BCVA), ellipsoid zone (EZ) defect, flap position, and surgical complications.ResultsAnatomical type 1 closure was achieved in all 42 eyes (100%). The proportion of favorable U-shaped closure decreased significantly with increasing hole size (χ2 = 9.26, df = 2, p = 0.010), with rates of 84.2%, 81.3%, and 20.0% in Groups 1, 2, and 3, respectively. BCVA and EZ defect improved significantly over time in all groups. Final BCVA gain was 4.4 ± 3.3, 6.2 ± 2.7, and 7.3 ± 4.7 ETDRS lines in Groups 1, 2, and 3, respectively, without significant inter-group differences (p > 0.05). Final BCVA correlated with preoperative BCVA (r = 0.51, p < 0.001) and final EZ defect (r = 0.39, p = 0.013), but not with iMH size or symptom duration (p > 0.05). No major complications were observed.ConclusionThe described surgical technique, involving the combination of a superior inverted ILM flap with extended ILM peeling and minimal manipulation of the posterior pole is highly effective in achieving anatomical and functional success in large iMHs up to 1000 µm, with a favorable safety profile and consistent structural recovery. Introduction Idiopathic macular hole (iMH) is a disruption of all neurosensory retinal layers at the foveal center that develops during anomalous posterior vitreous detachment and leads to significant visual loss.1 Successful surgical treatment with pars plana vitrectomy was first reported in 1991 by Kelly and Wendel,2 and the introduction of internal limiting membrane (ILM) peeling by Eckardt in 1997 improved closure rates to 92%.3 Multiple studies have demonstrated the benefits of ILM peeling in closing iMHs and preventing reopening.4,5 Following further surgical modifications, such as the inverted ILM flap technique,6 closure rates of up to 95–100% have been reported. However, for large iMHs with a minimum linear diameter (MLD) over 400 µm, surgical success rates decline, and in macular holes (MHs) larger than 500 µm, closure rates may fall to 60–85%.7–9 Moreover, closure morphologies associated with worse visual prognosis are more often observed in large holes, such as type 2, or “flat open” closure.10 Even when complete (type 1) closure of the MH is achieved, suboptimal configurations such as V shaped (approximated hole edges without repair of the outer layers) or W shaped (with irregular foveal contour) closure11 may occur. Various surgical techniques have been proposed to improve outcomes in large MHs, including extended ILM peeling,12 different ILM flap techniques,13–16 autologous retinal transplantation,17 amniotic membrane graft,18 and subretinal fluid-assisted MH edge mobilization.19 Recent meta-analyses suggest that both extended ILM peeling and flap techniques improve closure rates in MHs ≥400 µm MLD. ILM flap techniques are effective and safe in large holes, while other techniques are mostly recommended for very large refractory holes due to their procedural complexity or higher complication rates.20–22 Numerous modifications of the ILM flap method have been described, including temporal and superior flaps with limited ILM peeling and flaps trimmed to cover the hole area, with or without more extensive ILM peeling. The shape and orientation of the flap vary as well, with descriptions including clover leaf, retracting door, and pedicle rotational flaps.14,23,24 In earlier studies, the definition of large MH was variable; however, more recent evidence indicates that closure rates decline primarily in holes exceeding 500–550 µm MLD.7 The CLOSE study refined classification by defining size based subgroups: large >400 ≤550 µm, XL >550 ≤800 µm, XXL >800 ≤1000 µm, and giant >1000 µm.8 In this study, we present the outcomes of a simplified superior inverted ILM flap technique (SIFT). This technique combines a superior inverted flap with extended ILM peeling, both considered advantageous in large iMHs. Flap positioning is achieved using suction, without perfluorocarbon liquid or viscoelastic material, to minimize manipulation of the posterior pole. Materials and Methods This retrospective, non-randomized, interventional consecutive case series included patients who underwent the simple superior inverted ILM flap technique (SIFT) for full-thickness iMHs with a minimum linear diameter (MLD) ≥400 μm, performed at our institution between January 2019 and June 2025 by one experienced surgeon (LT). The examination protocol of this retrospective study was approved by the Regional and Institutional Ethical Committee of the University of Debrecen Clinical Centre (permission No.: RKEB-7347-2025) and was conducted in accordance with the Helsinki Declaration. Written informed consent to the intervention and to the use of anonymous clinical data for scientific and educational purposes was obtained from all patients before performing the operation. Clinical charts of 147 consecutive patients were reviewed, and those with iMHs larger than 400 μm (MLD) and operated on with the SIFT technique were selected. The study involved 42 eyes of 40 patients, grouped according to the CLOSE study classification.8 Eyes with high myopia (above −10.0D), traumatic MHs, MHs associated with retinal detachment, or previously operated iMHs that did not close (refractory MHs) were excluded. Seven eyes with iMHs with MLD between 400–500 µm were excluded, because they were operated with ILM peeling only, without flap creation (all reaching type 1 anatomical closure). All iMH cases above 500 µm MLD were operated on with the SIFT technique. Group 1 included 19 eyes with large (L) holes: MLD >400 to ≤550 μm. Group 2 included 18 eyes with extra-large (XL) holes: MLD >550 to ≤800 μm. Group 3 included 5 eyes with XXL holes: MLD >800 to ≤1000 μm. There were no giant holes (MLD >1000 μm) in this cohort. Patients were followed-up for a mean duration of 20.63 ±18.32 months. The primary endpoint was the MH closure rate assessed across groups. Secondary outcomes included closure type, changes in best corrected visual acuity (BCVA), ellipsoid zone (EZ) defect, flap position, and surgical complications. Snellen BCVA was recorded in decimal notation and converted to logarithm of the minimum angle of resolution (logMAR) for statistical analysis. For standardized interpretation, logMAR values were further converted into Early Treatment Diabetic Retinopathy Study (ETDRS) letter scores using the formula Letters = 85 − 50 × logMAR. Visual improvement was calculated as the difference between preoperative and final logMAR values and expressed in ETDRS letters and lines using the formulas Letters gained = (Preoperative logMAR − Final logMAR) × 50 and Lines gained = (Preoperative logMAR − Final logMAR) × 10. Surgical Technique A modified and simplified superior inverted flap technique with extended ILM peeling (SIFT) was employed (Video S1). All patients underwent standard 23-gauge vitrectomy. During surgery, PVD was induced with triamcinolone acetate assistance. Peripheral vitrectomy and vitreous base shaving with indentation were performed, and any peripheral retinal breaks were treated with endolaser photocoagulation. ILM was stained using Brilliant Blue-G 0.025% and Trypan Blue 0.15% (Membrane blue Dual, DORC). The ILM was removed between the major vascular arcades, at least 2 disc diameters in every direction from the center of the fovea, except for the superior flap in the following way: peeling was initiated at the inferior vascular arcade with a diamond-dusted sweeper (DORC) or Finesse Flex loop (Alcon). The ILM was then removed from the inferior part of the macula up to the vascular arcades, pulling toward the center of the MH from the initiation site. Similarly, peeling was initiated on the superior macula, creating 2–3 flower petal-shaped ILM flaps, of which one flap was left attached at the MH edge and trimmed with the vitrector to cover the hole only, the other 1 or 2 flaps were removed by pulling towards the center, similarly to the inferior part of the macula. Fluid-air exchange (FAX) was performed, during which fluid was suctioned to turn the flap onto the hole without forceps manipulation. No viscoelastic material or perfluorocarbon liquid (PFCL) was used during the procedure. If the flap failed to flip over the hole during FAX, a few drops of BSS were injected into the vitreous cavity, and the process was repeated. When epiretinal proliferation (EP) was present, it was left at the edge of the hole, trimmed, and turned onto the MH with the ILM flap. ERM, if present, was removed before ILM peeling. At the end of surgery, the vitreous cavity was filled with 20% SF6 gas, and patients were instructed to maintain face-down positioning for one week. Phacoemulsification was performed simultaneously with the pars plana vitrectomy if the patient was not pseudophakic. Postoperatively, patients were examined at 1, 3, 6, and 12 months, with follow-ups extending up to 60 months. At each visit, best corrected visual acuity (BCVA) was measured using Snellen charts, fundus examination along with spectral-domain OCT (SD-OCT) were performed using the Heidelberg Spectralis or SOLIX OCT platforms, depending on the site of examination. Data regarding closure type, EZ defect size, and flap position were recorded. Statistical Analysis Continuous variables are presented as mean ± standard deviation (SD), and categorical variables as counts and percentages. Normality of distribution was assessed using the Shapiro–Wilk test. Comparisons between groups were performed using one-way analysis of variance (ANOVA) for continuous variables and the chi-square (χ2) test for categorical variables. All statistical tests were two-tailed, and a p-value < 0.05 was considered statistically significant. Correlations were analyzed using Spearman’s rank correlation coefficient (r). Correlation matrices were visualized using triangular heat maps, with positive correlations shown in red, negative correlations in blue, and neutral values in white. Statistical significance was indicated as *p < 0.05, **p < 0.01, and ***p < 0.001. Statistical analyses were performed using IBM SPSS Statistics (version 24.0; IBM Corp., Armonk, NY). Results Patient baseline demographic characteristics are summarized in Table 1. There were no differences in age, gender, symptom duration, preoperative BCVA, or mean follow-up time between groups. Anatomical closure (type 1) was achieved in all cases across all groups (100%). However, the proportion of U-shaped closure decreased markedly with increasing hole size, from 89.5% in 400–550 µm to 81.3% in 550–800 µm and 20.0% in >800 µm (χ2=9.26, df=2, p=0.0098). Post-hoc comparisons demonstrated that eyes with holes >800 µm had significantly lower rates of U-shaped closure compared to both smaller groups, while no significant difference was observed between the 400–550 µm and 550–800 µm (Figure 1). In Figure 2a, a typical U-shaped closure pattern of a 625 µm MH is shown, where regeneration of the outer layers under the flap is observed with a small residual EZ defect at 12M postoperatively. Importantly, centripetal migration of the outer retinal layers beneath the flap was observed during follow-up, with progressive improvement in closure configuration. First, ELM continuity was reestablished, then the initial EZ defect decreased (Figures 2b and 3c). Such regeneration was seen in every case with good flap positioning. Only one case showed minimal migration of the outer layers (as described in the next paragraph). No major complications occurred.Table 1Baseline Characteristics of Patients Grouped by Macular Hole SizeVariable400–550 µm (n=19)550–800 µm (n=18)>800 µm (n=5)p-valueAge (years)69.9 ± 6.871.2 ± 7.070.6 ± 10.00.81Female (%)89.5%77.8%80.0%0.73Preoperative BCVA (logMAR)0.872 ± 0.3400.913 ± 0.4230.972 ± 0.4380.68Symptom duration (months)5.1 ± 2.66.3 ± 6.45.2 ± 2.30.77Follow-up time (months)14.8 ± 12.427.4 ± 23.321.0 ± 10.30.29Notes: Values are presented as mean ± standard deviation (SD) unless otherwise indicated. Female (%) represents the proportion of female patients within each group. P-values were calculated using one-way ANOVA for continuous variables and Chi-square or Fisher’s exact test for categorical variables, as appropriate. A p-value < 0.05 was considered statistically significant.Abbreviations: BCVA, Best-corrected visual acuity; logMAR, Logarithm of the minimum angle of resolution; SD, Standard deviation. Figure 1Closure morphology was significantly associated with macular hole size (χ2 = 9.26, df = 2, p = 0.0098). The proportion of U-shaped closure decreased markedly with increasing hole size, from 89.5% in 400–550 µm to 81.3% in 550–800 µm and 20.0% in >800 µm. Post-hoc comparisons demonstrated that eyes with holes >800 µm had significantly lower rates of U-shaped closure compared to both smaller groups, while no significant difference was observed between the 400–550 µm and 550–800 µm groups.A stacked bar graph titled U type vs Non U Closure by M H Size. X axis label M H Size Group, categories 400 dash 550 micro meter, 550 dash 800 micro meter and greater than 800 micro meter. Y axis label Percentage left parenthesis percent right parenthesis, range 0 to 100. Legend title Closure underscore Group with two series: U and Non dash U. For 400 dash 550 micro meter, U equals 85 percent and Non dash U equals 15 percent, total 100 percent. For 550 dash 800 micro meter, U equals 81 percent and Non dash U equals 19 percent, total 100 percent. For greater than 800 micro meter, U equals 20 percent and Non dash U equals 80 percent, total 100 percent.A stacked bar graph showing U type and Non U closure by macular hole size group. Figure 2MH closure after operation with the simple inverted ILM flap technique (SIFT). (a) Typical closure pattern of a XL hole: in a 625 µm MH, regeneration of the outer layers under the flap is observed, with closed ONL and ELM, but remaining little EZ defect 12M postoperatively. (b) In a patient with XXL 895 µm MH, initial W shaped closure is seen at 1M, subsequently, a slow regeneration of the outer layers is seen under the flap, with partial regeneration of the ONL, ELM and EZ layer by the 20M visit.Image A shows two grayscale OCT cross-sections of macular tissue. The 'Preop' section has a green marker indicating '625µm' across a gap between elevated tissue edges, with bright and dark bands and a central discontinuity. The '12M' section features a central indentation and narrower discontinuity. Below Image A is a lowercase 'a'. Image B displays four grayscale OCT cross-sections. The 'Preop' section has a red marker with a micrometer value across a gap, showing continuous bands with a darker space. The '1M' section has continuous bands with a shallow depression. The '3M' section shows a central depression and small elevation. The '12M' section features a central depression with a peak-like contour. The '20M' section displays a broader depression and thicker contours. Below Image B is a lowercase 'b'.Composite figure: 6 grayscale OCT cross-sections of macular tissue, pre-op and follow-up, with measurements. Figure 3Three minor complications were observed. (a) A 72 year old lady had a 788 µm MH and a central RPE defect. During FAX, the ILM flap was lost. In spite of this, the MH was closed with a V type closure. Subsequently, the RPE defect enlarged and glial tissue was observed in the central macula. The ELM, EZ or ONL layers did not regenerate over the very long follow-up time. (b) In a patient who could not keep face-down position, flap displacement occurred (arrows) but the MH closed with a U-shaped pattern and partial EZ recovery was also observed by 6M. (c) A patient with a 784 µm MH could not keep face_down position. The ILM flap was partially displaced and an initial V-shaped closure was observed. Later, the ELM closed under the flap and significant EZ restauration was also observed and a deep U shaped closure was observed at the 14M visit.The image A showing four rows of paired ophthalmic images on a white background. In each row, the left side contains a grayscale retinal en face view with branching dark vessels and a green rectangular scan box centered near the bright central region. The right side of each row contains a grayscale optical coherence tomography cross-section aligned horizontally. The rows are labeled Preop, 1M, 12M and 60M in black text near the corresponding cross-sections. The Preop cross-section contains a small numeric annotation near the central region reading 788. The 1M, 12M and 60M rows repeat the same paired layout with the green rectangular scan box on the en face image and a corresponding cross-section on the right. The image B showing a central cluster of ophthalmic images arranged in a top-and-bottom layout. At the top, a grayscale optical coherence tomography cross-section is labeled Preop, with a red measurement annotation reading 472 µm placed above the central portion of the scan. Below the top scan, two smaller grayscale retinal en face views are stacked vertically and labeled 1M and 6M. Each of these en face views contains a green rectangular scan box and a white arrow inside the box pointing toward a feature within the boxed region. To the right of each of these two en face views is a corresponding grayscale optical coherence tomography cross-section. Each of the two right-side cross-sections contains a black arrow pointing to a narrow vertical feature within the layered scan. The image C showing five rows of paired ophthalmic images on a white background. In each row, the left side contains a grayscale retinal en face view with a green radial scan overlay composed of multiple straight green lines converging at the bright central region. The right side of each row contains a grayscale optical coherence tomography cross-section aligned horizontally. The rows are labeled Preop, 1M, 6M, 12M and 24M in black text near the corresponding cross-sections. In the Preop row, the cross-section includes a purple measurement annotation reading 784 µm near the upper right portion of the scan. The remaining rows repeat the same paired layout with the green radial overlay on the en face image and a corresponding cross-section on the right.Ophthalmic image: 3 sub-images (a, b, c) with grayscale retinal views, green overlays and OCT cross-sections. Table 1Baseline Characteristics of Patients Grouped by Macular Hole SizeVariable400–550 µm (n=19)550–800 µm (n=18)>800 µm (n=5)p-valueAge (years)69.9 ± 6.871.2 ± 7.070.6 ± 10.00.81Female (%)89.5%77.8%80.0%0.73Preoperative BCVA (logMAR)0.872 ± 0.3400.913 ± 0.4230.972 ± 0.4380.68Symptom duration (months)5.1 ± 2.66.3 ± 6.45.2 ± 2.30.77Follow-up time (months)14.8 ± 12.427.4 ± 23.321.0 ± 10.30.29Notes: Values are presented as mean ± standard deviation (SD) unless otherwise indicated. Female (%) represents the proportion of female patients within each group. P-values were calculated using one-way ANOVA for continuous variables and Chi-square or Fisher’s exact test for categorical variables, as appropriate. A p-value < 0.05 was considered statistically significant.Abbreviations: BCVA, Best-corrected visual acuity; logMAR, Logarithm of the minimum angle of resolution; SD, Standard deviation. Baseline Characteristics of Patients Grouped by Macular Hole Size Notes: Values are presented as mean ± standard deviation (SD) unless otherwise indicated. Female (%) represents the proportion of female patients within each group. P-values were calculated using one-way ANOVA for continuous variables and Chi-square or Fisher’s exact test for categorical variables, as appropriate. A p-value < 0.05 was considered statistically significant. Abbreviations: BCVA, Best-corrected visual acuity; logMAR, Logarithm of the minimum angle of resolution; SD, Standard deviation. Closure morphology was significantly associated with macular hole size (χ2 = 9.26, df = 2, p = 0.0098). The proportion of U-shaped closure decreased markedly with increasing hole size, from 89.5% in 400–550 µm to 81.3% in 550–800 µm and 20.0% in >800 µm. Post-hoc comparisons demonstrated that eyes with holes >800 µm had significantly lower rates of U-shaped closure compared to both smaller groups, while no significant difference was observed between the 400–550 µm and 550–800 µm groups. MH closure after operation with the simple inverted ILM flap technique (SIFT). (a) Typical closure pattern of a XL hole: in a 625 µm MH, regeneration of the outer layers under the flap is observed, with closed ONL and ELM, but remaining little EZ defect 12M postoperatively. (b) In a patient with XXL 895 µm MH, initial W shaped closure is seen at 1M, subsequently, a slow regeneration of the outer layers is seen under the flap, with partial regeneration of the ONL, ELM and EZ layer by the 20M visit. Three minor complications were observed. (a) A 72 year old lady had a 788 µm MH and a central RPE defect. During FAX, the ILM flap was lost. In spite of this, the MH was closed with a V type closure. Subsequently, the RPE defect enlarged and glial tissue was observed in the central macula. The ELM, EZ or ONL layers did not regenerate over the very long follow-up time. (b) In a patient who could not keep face-down position, flap displacement occurred (arrows) but the MH closed with a U-shaped pattern and partial EZ recovery was also observed by 6M. (c) A patient with a 784 µm MH could not keep face_down position. The ILM flap was partially displaced and an initial V-shaped closure was observed. Later, the ELM closed under the flap and significant EZ restauration was also observed and a deep U shaped closure was observed at the 14M visit. Three minor complications were noted. In one case (MLD 788μm), ILM flap was lost during FAX. After flap loss, massaging of the hole edges was attempted, the case was finalized with 20% SF6 fill and the patient was asked to keep face-down position for one week. This case also demonstrated a round central retinal pigment epithelial (RPE) defect that enlarged during the postoperative follow-up and surgical manipulation possibly contributed to its enlargement. During a very long follow-up period (60M), EZ and ELM defect persisted, possibly due to the concurrent RPE defect, although glial proliferation could be observed in the foveal area, which ensured type 1 anatomical closure (Figure 3a). In two cases, patients were unable to maintain face-down positioning. In one (MLD 472 µm), flap displacement occurred; however, the MH remained closed (Figure 3b). In the other case (MLD 784 μm), a V-shaped closure was detected with the flap covering approximately 2/3 of the hole; however, outer-layer morphology progressively improved beneath the flap, achieving a deep U-shaped configuration by the 24-month visit (Figure 3c). Best corrected visual acuity significantly improved in all groups at 1, 3, 6 months, and final follow-up (Figure 4a, Table 2 and Table 3). There was no significant difference in the BCVA between groups at any time point (Table 2). The final BCVA gain was 4.4±3.3, 6.2±2.7 and 7.3±4.7 ETDRS lines in Groups 1, 2 and 3, respectively (Table 3). Alongside BCVA improvement, a decrease in the EZ defect was observed across all groups (Figure 4b). Larger holes demonstrated greater initial EZ disruption and a tendency toward larger defects at follow-up; however, no statistically significant differences were observed between groups at any postoperative time point (all p > 0.05, Table 4). Correlation analysis demonstrated strong positive associations between EZ defect measurements across postoperative time points (up to r = 0.94, p < 0.001), indicating high temporal consistency of structural recovery. Similarly, BCVA measurements were strongly correlated over time (up to r = 0.88, p < 0.001). Final BCVA showed a moderate correlation with preoperative BCVA (r = 0.51, p < 0.001) and final EZ defect (r = 0.39, p = 0.013). In contrast, no significant correlations were found between final BCVA and MH size or symptom duration (Figure 5).Table 2Changes in BCVA(LogMar) After Surgery According to Macular Hole SizeTimepoint400–550 µm (n=19)550–800 µm (n=18)>800 µm (n=5)p-valuePreoperative0.87 ± 0.340.91 ± 0.420.97 ± 0.440.8661 Month0.75 ± 0.400.65 ± 0.320.80 ± 0.300.5893 Months0.58 ± 0.290.49 ± 0.400.64 ± 0.210.6416 Months0.45 ± 0.300.36 ± 0.300.38 ± 0.290.705Last visit0.44 ± 0.320.30 ± 0.280.24 ± 0.190.245Note: Values are mean ± standard deviation. Table 3Visual Acuity ImprovementMH Size GroupLetters Gained (mean ± SD)Lines Gained (mean ± SD)n400–550 µm21.8 ± 16.74.4 ± 3.319550–800 µm30.8 ± 13.36.2 ± 2.718>800 µm36.6 ± 23.57.3 ± 4.75 Table 4EZ Defect Size Over Time According to Macular Hole SizeTimepoint400–550 µm (mean ± SD)550–800 µm (mean ± SD)>800 µm (mean ± SD)p-value1 Month962 ± 4501246 ± 5311437 ± 2500.1013 Months650 ± 437950 ± 665948 ± 4230.2436 Months344 ± 428579 ± 545691 ± 6650.2951 Year206 ± 480463 ± 601552 ± 6690.344Last177 ± 308482 ± 645421 ± 6950.227 Figure 4(a) Change in best corrected visual acuity (BCVA) over time after surgery. (b) Change in ellipsoid zone (EZ) defect over time after surgery.Image A shows 'BCVA Over Time by MH Size Groups': '400–550 µm', '550–800 µm', '>800 µm'. The x-axis is 'Time' with 'Preop', '1M', '3M', '6M', 'Last' and the y-axis is 'BCVA (logMAR)' from 0.0 to 1.4. For 400–550 µm, BCVA improves from 0.9 at Preop to 0.44 at Last. For >800 µm, it improves from 0.97 at Preop to 0.25 at Last. The 550–800 µm group decreases from 0.88 at Preop to 0.30 at Last. Vertical error bars are shown. Image B depicts 'EZ Defect Over Time by MH Size Groups (Postoperative)' with the same groups. The x-axis is 'Time' with '1M', '3M', '6M', '1Y', 'Last' and the y-axis is 'EZ defect' from 0 to 1800. For 400–550 µm, defects reduce from 950 at 1M to 170 at Last. The 550–800 µm group decreases from 1250 at 1M to 480 at Last. For >800 µm, defects decrease from 1450 at 1M to 420 at Last. Vertical error bars are included. Labels 'a' and 'b' are below the graphs.A pair of line graphs showing best corrected visual acuity and ellipsoid zone defect over time by MH size groups. Figure 5Spearman correlation heatmap demonstrating relationships between BCVA at different time points, EZ defect measurements, MH size and symptom duration. Positive correlations are shown in red, negative correlations in blue, and weak or absent correlations in white. Statistical significance is indicated by asterisks (*p < 0.05, **p < 0.01, ***p < 0.001).A heatmap titled 'Correlation' displays relationships between variables using Spearman's r, ranging from -1.00 to 1.00. The X and Y axes include: EZ 1M, EZ 3M, EZ 6M, EZ 1Y, EZ Last, Symptom duration, MH size, VA Preop, VA 1M, VA 3M, VA 6M, VA Last. Key correlations in the lower triangle are: EZ 3M & EZ 1M: 0.67***; EZ 6M & EZ 3M: 0.60***; EZ 1Y & EZ 6M: 0.83***; EZ Last & EZ 1Y: 0.94***. Symptom duration shows weak negative correlations with EZ measures. MH size has low correlations with EZ measures. VA Preop correlates strongly with VA 1M (0.65***), VA 3M (0.69***), VA 6M (0.54***) and VA Last (0.51***). VA 1M correlates with VA 3M (0.72***), VA 6M (0.67***) and VA Last (0.60***). VA 3M correlates with VA 6M (0.88***) and VA Last (0.79***). VA 6M correlates with VA Last (0.84***). Asterisks indicate significance levels: *p<0.05, **p<0.01, ***p<0.001.A Spearman correlation heatmap of EZ and VA time points, symptom duration and MH size, with cell values. Table 2Changes in BCVA(LogMar) After Surgery According to Macular Hole SizeTimepoint400–550 µm (n=19)550–800 µm (n=18)>800 µm (n=5)p-valuePreoperative0.87 ± 0.340.91 ± 0.420.97 ± 0.440.8661 Month0.75 ± 0.400.65 ± 0.320.80 ± 0.300.5893 Months0.58 ± 0.290.49 ± 0.400.64 ± 0.210.6416 Months0.45 ± 0.300.36 ± 0.300.38 ± 0.290.705Last visit0.44 ± 0.320.30 ± 0.280.24 ± 0.190.245Note: Values are mean ± standard deviation. Changes in BCVA(LogMar) After Surgery According to Macular Hole Size Note: Values are mean ± standard deviation. Table 3Visual Acuity ImprovementMH Size GroupLetters Gained (mean ± SD)Lines Gained (mean ± SD)n400–550 µm21.8 ± 16.74.4 ± 3.319550–800 µm30.8 ± 13.36.2 ± 2.718>800 µm36.6 ± 23.57.3 ± 4.75 Visual Acuity Improvement Table 4EZ Defect Size Over Time According to Macular Hole SizeTimepoint400–550 µm (mean ± SD)550–800 µm (mean ± SD)>800 µm (mean ± SD)p-value1 Month962 ± 4501246 ± 5311437 ± 2500.1013 Months650 ± 437950 ± 665948 ± 4230.2436 Months344 ± 428579 ± 545691 ± 6650.2951 Year206 ± 480463 ± 601552 ± 6690.344Last177 ± 308482 ± 645421 ± 6950.227 EZ Defect Size Over Time According to Macular Hole Size (a) Change in best corrected visual acuity (BCVA) over time after surgery. (b) Change in ellipsoid zone (EZ) defect over time after surgery. Spearman correlation heatmap demonstrating relationships between BCVA at different time points, EZ defect measurements, MH size and symptom duration. Positive correlations are shown in red, negative correlations in blue, and weak or absent correlations in white. Statistical significance is indicated by asterisks (*p < 0.05, **p < 0.01, ***p < 0.001). Discussion In this report, we present the results of a simplified superior inverted ILM flap technique (SIFT) for treating large iMHs. The method is a simplified modification of the superior inverted ILM flap technique,16 combined with enlargement of ILM peeling up to the vascular arcades. Type 1 anatomical closure and significant functional improvement were achieved in all our cases treated with this method. The SIFT technique represents a novel incremental refinement of the superior ILM flap technique that may contribute to increased MH closure in several ways: 1) The extended peeling area improves retinal compliance and encourages centripetal migration of MH edges. Similarly, enlargement of the ILM peel up to the vascular arcades has been shown to be beneficial in extra-large holes and refractory MH cases.12,25 2) Pulling ILM pieces toward the center during peeling may further enhance MH edge mobilization. Recently, in the APOSTEL study, mobilizing MH edges by injecting fluid subretinally effectively promoted closure in refractory MHs.19 Massaging the MH edges toward the center26 was shown to aid closure as well. 3) The single-layer inverted ILM flap acts as a scaffold and promotes centripetal migration of outer layers, as demonstrated by many studies using various flap techniques („flap closure”).27,28 4) Trimming the inverted ILM flap to the size of the MH ensures adequate coverage but prevents potential fibrosis and shrinkage of the ILM flap, which can cause long-term visual disturbances, seen in some previous studies with large ILM flaps.29,30 5) Minimizing manipulation around the hole by flipping the flap over the MH using only suction, without viscoelastic material or PFCL, helps preserve the foveal structure.31,32 While the large-area ILM removal in SIFT offers benefits, it may also harm Müller cell pedicles and lead to dissociated optic nerve fiber layer (DONFL). Initially, DONFL was thought to reduce macular sensitivity.33,34 However, a recent study showed that decreased retinal sensitivity after ERM peeling correlates with outer and inner retinal layer damage caused by ERM, rather than the presence of DONFL.35 Furthermore, a randomized trial found similar DONFL scores whether ILM was peeled only temporally or circumferentially around the MH, with comparable retinal sensitivity in both groups.36 Functional outcomes tend to be poorer if secondary surgery is required due to failed MH closure, making primary closure preferable.31 We believe that the BCVA gains and 100% primary closure rate observed in our patients outweigh any subtle functional issues related to larger ILM peel areas. Most studies have suggested that final visual recovery depends on MH size.37–39 We could not demonstrate such an association. This may be due to the long (> 1-year) follow-up in most of our cases. During this period, significant visual recovery and EZ repair were observed even in very large (800–1000 μm) holes. In a previous study, continuous visual improvement was seen for at least 3 years after MH surgery,40 and centripetal migration of photoreceptor cells was suggested during MH recovery.28 A recent study confirmed increased spacing and dispersion of photoreceptors (PRs) near the MH edges, indicating that stretching/elongation of the PR layer may play a role during MH repair.41 The ILM flap placed over the MH acts as a scaffold for MH closure,27 and RPE cells can promote photoreceptor migration toward the centre.28 In fact, in one case where we experienced flap loss and the patient had a central RPE defect, central EZ restoration was not observed, and VA recovery remained modest. An important observation in our study is that long-term postoperative BCVA correlated only with preoperative BCVA. Similar associations were found in other studies as well.9,42 This suggests that the repair processes seen after successful closure—such as ELM closure, inward migration of the outer retinal layers, and decreasing EZ defects—occur even in very large holes, and long-term visual recovery may depend on initial PR damage, as previously suggested by our group.43 Unlike in other studies,9 the duration of symptoms before surgery did not significantly influence final BCVA in our cohort. After MH opening, photoreceptors at the MH edges elevate from the RPE and contact the hypoosmotic vitreous fluid, leading to gradual deterioration of the photoreceptor bacillary layer. The transition from swelling to more pronounced loss was observed after a mean duration of ≈280 days.44 Most of our patients were operated on within this timeframe, before severe PR loss occurred, which likely explains why we could not observe a significant correlation with symptom duration. We advised our patients to maintain face-down positioning for one week. Studies have shown that with superior flaps, prone positioning may not be necessary.13,16 Other research has suggested that face-down positioning offers advantages in large holes.45 We observed flap displacements in cases when patients could not remain in a prone position. In the first case (421 μm hole), the closure was complete despite displacement; in the second, most of the flap remained in place, and the EZ layer recovered on the long-term under the flap, with significant BCVA improvement. Nonetheless, we recommend that maintaining face-down positioning for several days may be prudent in cases of large holes, even when using superior inverted flaps. While the results demonstrate a high anatomical closure rate and favorable functional recovery, several limitations must be considered. First, the retrospective design and lack of a control group preclude direct comparison with standard ILM peeling or alternative flap techniques. Therefore, no conclusions regarding superiority can be drawn. Second, the small number of cases in the XXL group limits the statistical power of subgroup analyses. Third, the use of two different OCT platforms (Spectralis and SOLIX) may introduce variability in EZ defect measurements, although imaging protocols were applied consistently within each device. Although this study involved consecutive iMH cases, more challenging MHs secondary to trauma or high myopia as well as giant and refractory holes were not included. The 100% closure rate observed in this cohort is encouraging but should be interpreted with caution, and usefulness of this technique in challenging cases must be further examined. Conclusion The simple superior inverted ILM flap technique (SIFT) described in this study is a safe and highly effective method for closing large iMHs up to 1000 µm. In this cohort, a 100% type 1 anatomical closure rate was achieved, accompanied by the gradual recovery of the outer retinal layers under the flap and parallel improvement in BCVA over the long term, even in very large holes. No significant surgery-related complications were observed. However, further prospective, controlled studies are required to confirm these findings and to compare outcomes with other established surgical techniques.