Tunable Bessel beam two-photon fluorescence microscopy for high-speed volumetric imaging of brain dynamics Authors: Mengyang Jacky Li, Jinghui Wang, Mikolaj Walczak, Yuqing Qiu, Colleen Russell, Miroslaw Janowski, Piotr Walczak, Yajie Liang, Tian-Ming Fu, Brice Bathellier, Tian-Ming Fu, Mengyang Jacky Li, Jinghui Wang, Mikolaj Walczak, Yuqing Qiu, Colleen Russell, Miroslaw Janowski, Piotr Walczak, Yajie Liang Published: 2026 ABSTRACT High-speed volumetric imaging of the brain is essential for linking diverse cellular events to tissue-level functions. However, the brain’s structural and dynamic heterogeneity—spanning microns to millimeters and milliseconds to hours—requires imaging techniques with tunable spatiotemporal resolution, flexible 3D sampling, and compatibility with targeted perturbations. Here, we present tunable Bessel beam two-photon fluorescence microscopy (tBessel-TPFM), a compact, low-cost, and versatile platform for intravital brain imaging across millimeter scale with subcellular resolution. tBessel-TPFM transforms slow 3D volume scans into fast 2D frame scans via an axially elongated Bessel focus, achieving acquisition rates ~100 fold faster and reduced motion artifacts compared with conventional TPFM. Exploiting its full tunability of the Bessel focus, we applied tBessel-TPFM for quantitative mapping of cerebral blood flow and neurovascular coupling in normal and ischemic stroke mice. Unlike existing Bessel focus generation methods, the axial center of tBessel-TPFM remains fixed at the objective focal plane during profile tuning. Leveraging this advantage, we integrated tBessel-TPFM with simultaneous 3D targeted optogenetic stimulation for volumetric neuronal connectivity mapping. We also tracked microglial process dynamics following single-cell laser ablation, revealing diverse neuroimmune responses across spatial and temporal scales. By combining high speed, deep penetration, tunable sampling, and multimodal perturbation, tBessel-TPFM empowers a broad spectrum of neurobiological investigations—from vascular physiology and functional connectivity to neuroimmune interactions. Introduction The brain’s normal function relies on a dynamic interplay between diverse biological processes. These interactions span across spatial and temporal scales, from blood flows within hierarchical vascular networks and communication among neurons forming complex circuits to the constant surveillance for damage and pathogens by glial cells. Studying these processes requires the ability to observe volumetric dynamics deep within highly scattering brain tissues. Moreover, each process imposes its distinct imaging demands. For example, hemodynamics mapping requires only moderate spatial resolution to visualize capillaries but demands acquisition rates up to the kilohertz range to capture fast blood flows in arteries and veins. In contrast, imaging microglial dynamics requires subcellular resolution to identify fine processes, but only sub-second temporal resolution. A versatile, cost-effective imaging platform capable of capturing volumetric biological dynamics in the brain while accommodating such diverse requirements could facilitate discoveries across neuroscience, neurology, brain immunology, and oncology. Furthermore, integrating spatiotemporally patterned perturbations into such a platform would enable simultaneous targeted interventions and volumetric investigations, providing broad-reaching implications for the development of novel therapeutic strategies. In recent years, several promising brain imaging technologies have emerged. Functional magnetic resonance imaging offers whole-brain coverage, but lacks cellular resolution (Aries et al., 2010; D’Esposito et al., 2003). Optical coherence tomography allows label-free contrast with moderate penetration depth, yet falls short to resolve subcellular structures (Drexler et al., 2001; Tang et al., 2025). Time-resolved laser speckle imaging, while offering better spatial resolution, suffers from limited depth (Boas and Dunn, 2010; Vaz et al., 2016). Photoacoustic imaging can penetrate deeper, but its depth-dependent resolution complicates data interpretation (Lin and Wang, 2022). Two-photon fluorescence microscopy (TPFM), which scans a spatially confined Gaussian focus across a three-dimensional (3D) volume, can achieve subcellular resolution deep within highly scattering brain tissues (Göbel and Helmchen, 2007; Shih et al., 2012; Sofroniew et al., 2016; Scheele et al., 2022; Xu et al., 2024). As such, TPFM has been widely adopted for in vivo brain imaging, revealing insights from synaptic plasticity to glia-neuron interactions (Scheele et al., 2022; Xu et al., 2024). Nevertheless, scanning the focus across all three dimensions results in slow volumetric acquisitions (Wu et al., 2021). To address this, strategies such as remote focusing, spatiotemporal multiplexing, and projection imaging have been developed (Grewe et al., 2011; Kim and Schnitzer, 2022; Weisenburger and Vaziri, 2018; Peinado et al., 2021; Wu et al., 2021; Ito et al., 2022). Notably, an elegant approach—Bessel beam TPFM—employs an axially elongated Bessel focus and converts a 3D volumetric scan into a 2D frame scan, enabling video-rate volumetric imaging with diffraction-limited resolution (Lu et al., 2017). Despite its advantages, current Bessel beam generation methods limit the widespread adoption of Bessel beam TPFM in biomedical research. Systems based on a single axicon-lens pair lack the tunability to meet diverse brain imaging demands. Spatial light modulator (SLM)-based approaches offer tunability, but are prohibitively expensive, incompatible with simultaneous multi-wavelength excitation, and suffer from significant light loss. Several methods exploiting the combinations of axicons and lenses have been reported (Brzobohatý et al., 2008; Lu et al., 2018; Schnieder et al., 2024; Takanezawa et al., 2021), but they all introduce axial shifts of the Bessel beam during beam profile tuning. These unwanted focal shifts necessitate frequent system realignment and prevents integration with simultaneous optogenetic stimulation or laser ablation (Wang et al., 2016). Here, we overcome these limitations by introducing tunable Bessel beam two-photon fluorescence microscopy (tBessel-TPFM), a compact, low-cost, light-efficient, and versatile platform for intravital imaging of diverse brain dynamics across millimeter scale with subcellular resolution. Importantly, tBessel-TPFM allows for adaptive tuning of the Bessel beam’s spatial resolution, volume coverage, and energy confinement to optimize for specific imaging needs. Leveraging this tunability, we quantitatively measured cerebral blood flows in normal and ischemic stroke mice across spatial and temporal scales—from slow blood flows in tiny capillaries to ultrafast flows in arteries and veins. With implemented focal jumping and lateral tiling, we monitored capillary blood flow and diameter changes in real time across a 2500×2500×450 μm3 cortical volume, and imaged neurovascular coupling (NVC) across cortical layers in awake mice. Furthermore, unlike existing methods, tBessel-TPFM maintains the axial center of the Bessel beam at the objective focal plane during profile tuning, enabling integration with 3D targeted optogenetic stimulation for volumetric neuronal connectivity mapping. Finally, by combining high spatial resolution, rapid volumetric acquisition, and simultaneous two-photon perturbation, we tracked microglial process dynamics following single-cell laser ablation, revealing rapid neuroimmune responses. Results Tunable Bessel beam two-photon fluorescence microscopy In contrast to conventional Gaussian TPFM that scans an axially confined Gaussian focus across a 3D volume (Figure 1A, top), Bessel-TPFM images the same volume by scanning an axially extended Bessel beam across a 2D plane (Figure 1A, bottom) (Lu et al., 2017). When the Bessel beam length matches the depth of the imaging volume, the resulting image corresponds to a 2D projection of the 3D stack that would otherwise require 10–100 sequential z-slices using conventional Gaussian TPFM, therefore, achieving a 10–100× increase in acquisition speed by capturing the entire volume in a single frame (Fan et al., 2020). For hemodynamics and functional imaging where the biological structures—vasculatures and neurons—remain largely unchanged, a two-step strategy is adopted: first, acquire a high-resolution 3D structural reference with conventional Gaussian TPFM, then perform dynamic volumetric imaging with Bessel-TPFM (Figure 1A). The three core imaging metrics of Bessel-TPFM—spatial resolution, temporal resolution, and structural overlap—are inherently linked in a triangular trade-off (Figure 1B). Optimizing these competing metrics for different applications, such as capillary flow versus neuronal activities, requires the ability to adjust the Bessel beam properties independently. Concept, design, and characterization of tunable Bessel two-photon microscopy. (A) Comparison of Gaussian (top) and Bessel (bottom) two-photon fluorescence microscopy (TPFM). Gaussian imaging requires sequential acquisition of 2D images at different axial positions, whereas Bessel imaging captures the entire volume in a single frame. (B) Fundamental trade-offs in Bessel beam imaging between spatial resolution, temporal resolution, and axial distinguishability, governed by the numerical aperture (NA), beam length, and side-ring confinement. (C) For targeted opto-stimulation, Bessel beam tuning must preserve a fixed axial beam center to maintain co-registration with stimulation or ablation beams. (D) Schematic of the tunable Bessel module (A1–A3, axicons; L1–L3, lenses; iris) and its integration with Gaussian-TPFM. A1 with L1 generates the Bessel beam; the iris adjusts ΔNA; A2–A3 spacing sets NA; L2–L3 form a 4f relay to the scanning galvo. (E) Zemax simulations showing pupil (left), sample (middle), and propagation (right) images for 0.8 NA with open iris (top), 0.4 NA with open iris (middle), and 0.4 NA with 10% iris opening (bottom). Scale bar: 25λ/n, where n is the refractive index of the immersion medium. (F) Simulated versus experimental Bessel beam cross-section profiles at NA = 0.4 (top) and 0.8 (bottom). Experimental images were acquired using a camera conjugate to the objective’s sample plane. Scale bar: λ/n. (G) Theoretical and experimental results showing adjustment of the Bessel beam NA (blue), resolution (orange), and length (green) as a function of A2-A3 spacing. (H) Simulated versus experimental Bessel beam pupil profiles for ΔNA = 0.005 (top) and 0.041 (bottom). Experimental images were acquired using a camera conjugate to the objective’s back focal plane. (I) Theoretical and experimental results showing adjustment of the Bessel beam ΔNA (blue), half total power radius (orange), and length (green). Figure 1—figure supplement 1.Comparison of Bessel beams tuning method.(A) Axicon-lens design. This method adjusts the numerical aperture (NA) and ΔNA through defocusing the last lens. It lacks independent control over NA and ΔNA, and the waist of the generated Bessel beam shifts axially when being tuned. (B) Lens-axicon design. Similar to (A), this method relies on the last lens for tuning NA and ΔNA. It also leads to the generated Bessel beam waist shift axially when being tuned. (C) Dual-axicon design. This method provides independent control of NA and ΔNA, but the generated pupil ring has a non-flat wavefront, causing the Bessel beam waist to shift axially. (D) Focused Bessel beam generation method utilizing an axicon pair. This approach achieves independent NA and ΔNA control without shifting the Bessel beam waist. However, this method is limited to generate short Bessel beams. (E) This design enables independent NA and ΔNA control, but the waist of the generated Bessel beam shift axially when being tuned. Comparison of Bessel beams tuning method. (A) Axicon-lens design. This method adjusts the numerical aperture (NA) and ΔNA through defocusing the last lens. It lacks independent control over NA and ΔNA, and the waist of the generated Bessel beam shifts axially when being tuned. (B) Lens-axicon design. Similar to (A), this method relies on the last lens for tuning NA and ΔNA. It also leads to the generated Bessel beam waist shift axially when being tuned. (C) Dual-axicon design. This method provides independent control of NA and ΔNA, but the generated pupil ring has a non-flat wavefront, causing the Bessel beam waist to shift axially. (D) Focused Bessel beam generation method utilizing an axicon pair. This approach achieves independent NA and ΔNA control without shifting the Bessel beam waist. However, this method is limited to generate short Bessel beams. (E) This design enables independent NA and ΔNA control, but the waist of the generated Bessel beam shift axially when being tuned. Figure 1—figure supplement 2.Tunable Bessel module.(A) Input and output of an axicon. (B) Optical diagram of tunable Bessel module with system parameters defined. (C) Optical diagrams showing the module’s capability to independently tune the numerical aperture (NA) (comparing top and middle row) and ΔNA (comparing bottom and middle row). (D) Photo of the tunable Bessel module integrated into a Gaussian-two-photon fluorescence microscopy (TPFM). (E) Experimental comparison of simultaneously two-color Bessel beams with 520 nm (left) and 635 nm (top right) laser. The top right panel presents the 635 nm Bessel beam in physical units (µm), showing its intrinsically larger focus due to the longer wavelength. In the bottom right panel, the 635 nm beam is rescaled by a factor of 520/635 to normalize for wavelength-dependent diffraction. Since the lateral size of the Bessel focus scales linearly with wavelength, this normalized comparison demonstrates that the two beams have identical profiles after accounting for their wavelength difference. (F) Intensity profiles from the vertical dashed white line of (E) comparing the two colors. The horizontal axis is rescheduled by their corresponding wavelengths. (G) Experimental comparison of the two colors pupil profile. (H) Experimental NA comparison between the two colors at various NAs. (I) Experimental axial point spread function (PSF) of NA at 0.4, 0.6, and 0.8 NA. The slight non-uniformities in axial intensity are consistent across different NA settings. This is not induced by the tunable Bessel (tBessel) module itself but rather the centrally peaked intensity distribution of the input Gaussian beam, and axicon tip imperfections (Dudutis et al., 2016). Tunable Bessel module. (A) Input and output of an axicon. (B) Optical diagram of tunable Bessel module with system parameters defined. (C) Optical diagrams showing the module’s capability to independently tune the numerical aperture (NA) (comparing top and middle row) and ΔNA (comparing bottom and middle row). (D) Photo of the tunable Bessel module integrated into a Gaussian-two-photon fluorescence microscopy (TPFM). (E) Experimental comparison of simultaneously two-color Bessel beams with 520 nm (left) and 635 nm (top right) laser. The top right panel presents the 635 nm Bessel beam in physical units (µm), showing its intrinsically larger focus due to the longer wavelength. In the bottom right panel, the 635 nm beam is rescaled by a factor of 520/635 to normalize for wavelength-dependent diffraction. Since the lateral size of the Bessel focus scales linearly with wavelength, this normalized comparison demonstrates that the two beams have identical profiles after accounting for their wavelength difference. (F) Intensity profiles from the vertical dashed white line of (E) comparing the two colors. The horizontal axis is rescheduled by their corresponding wavelengths. (G) Experimental comparison of the two colors pupil profile. (H) Experimental NA comparison between the two colors at various NAs. (I) Experimental axial point spread function (PSF) of NA at 0.4, 0.6, and 0.8 NA. The slight non-uniformities in axial intensity are consistent across different NA settings. This is not induced by the tunable Bessel (tBessel) module itself but rather the centrally peaked intensity distribution of the input Gaussian beam, and axicon tip imperfections (Dudutis et al., 2016). Figure 1—figure supplement 3.Zemax simulation of the tunable Bessel module: numerical aperture (NA) tuning.(A) Zemax diagram of the tunable Bessel module. (B) Pupil intensity profiles (top) of three Bessel beams with NA = 0.17, 0.37, and 0.57 (same ΔNA) by varying the separation between the two 5o axicons. Line cuts of the intensity profiles (bottom) show that ΔNA remains constant, demonstrating that adjustments to the axicon pair distance do not impact the delta NA of the system. (C) Pupil phase profiles (top) and line cuts (bottom) of the three Bessel beams in (B). Zemax simulation of the tunable Bessel module: numerical aperture (NA) tuning. (A) Zemax diagram of the tunable Bessel module. (B) Pupil intensity profiles (top) of three Bessel beams with NA = 0.17, 0.37, and 0.57 (same ΔNA) by varying the separation between the two 5o axicons. Line cuts of the intensity profiles (bottom) show that ΔNA remains constant, demonstrating that adjustments to the axicon pair distance do not impact the delta NA of the system. (C) Pupil phase profiles (top) and line cuts (bottom) of the three Bessel beams in (B). Figure 1—figure supplement 4.Zemax simulation of the tunable Bessel module: ΔNA tuning, pupil plane characterization.(A) Pupil intensity profiles (top) and line cuts (bottom) of three Bessel beams with ΔNA = 0.019, 0.025, and 0.038 (same numerical aperture, NA) by varying the iris opening diameter. (B) Pupil phase profiles (top) and line cuts (bottom) of the three Bessel beams in (A). Zemax simulation of the tunable Bessel module: ΔNA tuning, pupil plane characterization. (A) Pupil intensity profiles (top) and line cuts (bottom) of three Bessel beams with ΔNA = 0.019, 0.025, and 0.038 (same numerical aperture, NA) by varying the iris opening diameter. (B) Pupil phase profiles (top) and line cuts (bottom) of the three Bessel beams in (A). Figure 1—figure supplement 5.Zemax simulation of the tunable Bessel module: ΔNA tuning, sample plane.(A) Sample intensity profiles (top) of three Bessel beams with ΔNA = 0.019, 0.025, and 0.038 (same numerical aperture, NA) by varying the iris opening diameter. The larger the ΔNA, the less side-ring excitation the Bessel beam has. (B) Cumulative total energy distribution. The red lines indicate where the half total energy resides. Zemax simulation of the tunable Bessel module: ΔNA tuning, sample plane. (A) Sample intensity profiles (top) of three Bessel beams with ΔNA = 0.019, 0.025, and 0.038 (same numerical aperture, NA) by varying the iris opening diameter. The larger the ΔNA, the less side-ring excitation the Bessel beam has. (B) Cumulative total energy distribution. The red lines indicate where the half total energy resides. Figure 1—video 1.Independent continuous adjustment of numerical aperture (NA) and ΔNA with the tunable Bessel module. Independent continuous adjustment of numerical aperture (NA) and ΔNA with the tunable Bessel module. In practice, these metrics are governed by three key parameters of the Bessel beam: lateral resolution, axial beam length, and side-ring confinement. First, lateral resolution, set by the numerical aperture (NA) of the Bessel beam, determines the ability to resolve fine structures but comes at the cost of speed, as higher resolution requires a smaller scanning step size (Figure 1B, left). Optimal spatial resolution is, therefore, task-dependent: fine structural dynamics benefit from higher resolution, whereas ultrafast flow measurements favors faster frame rates. Second, axial beam length, set by the NA and NA broadening (ΔNA) of the beam, governs the depth coverage of the imaging volume, but at the cost of structural overlap: longer beams expand depth coverage at the same acquisition speed but can confound signals from closely spaced structures. (Figure 1B, right). Third, Bessel beam side-ring adds another constraint: high-NA, long Bessel beams generate substantial side-ring excitation, leading to potential imaging artifacts (Figure 1B, bottom)(Chen et al., 2024). While several elegant methods that can tune lateral resolution, axial beam length, and side-ring confinement exist, they all suffer from a key limitation: adjusting the Bessel beam profile shifts the beam axially, displacing the imaging volume (Figure 1—figure supplement 1; Dickey and Conner, 2011; Lu et al., 2018; Takanezawa et al., 2021). Although this undesired displacement is acceptable to certain imaging applications, it forces realignment, complicates experiments, and reduces reproducibility. Moreover, it is particularly problematic when imaging is combined with optogenetic stimulation or laser ablation, where precise co-registration of stimulation and imaging volumes is required (Figure 1C). Minimizing axial shift while tuning the Bessel beam profile is, therefore, a core requirement to enable volumetric perturbation–imaging studies. To meet this requirement, we designed a compact, tunable Bessel (tBessel) module that can be readily integrated into conventional Gaussian TPFM (Figure 1D). For broad adoptability and high light efficiency, the tBessel module uses only off-the-shelf components, avoiding programmable or diffractive elements (Figure 1—figure supplement 2). The optical design consists of three major parts. First, an axicon-lens pair (A1 and L1) converts a collimated beam into a focused ring beam—Fourier transform of a Bessel beam—at a rear pupil-conjugate plane. Second, to enable tunability, the diameter and thickness of the ring beam—corresponding to the NA and ΔNA, respectively—needs to be adjustable. Our tBessel module achieves NA tuning by exploiting a pair of axicons (A2 and A3, Figure 1D), where the separation between the two controls the NA. Importantly, varying this separation introduces minimum phase variation (Figure 1—figure supplement 3, and Appendix 2), resulting in negligible axial shift (Figure 1E; Figure 1—figure supplement 2, Figure 1—video 1, and Appendix 1). To enable independent adjustment of ΔNA, an iris is conjugated to the objective focal plane (Figure 1E; Figure 1—figure supplement 4, and Figure 1—video 1). This decoupled control of NA and ΔNA allows independent tuning of the Bessel beam’s spatial resolution and side-ring confinement (Figure 1E and Figure 1—video 1). Next, we characterized the tBessel module experimentally. First, by varying the axicon pair separation, the resolution of the Bessel beam can be adjusted in close agreement with numerical simulations (Figure 1F). Quantitatively, spatial resolution scales inversely with the axicon pair separation, while axial beam length varied accordingly (Figure 1G). Second, changing the iris aperture alters the ΔNA, as evidenced by the pupil profile images that match numerical simulations (Figure 1H). Quantitatively, ΔNA scales inversely with iris aperture, and both axial beam length and side-ring confinement radius—defined as the radius where half of the total power is contained—vary linearly with the iris aperture (Figure 1I, Figure 1—figure supplement 5). Noticeably, across the full tuning range, experimental and simulated results showed excellent agreement in lateral resolution, axial beam length, and side-ring confinement. Finally, the tBessel module is capable of simultaneous multi-wavelength excitation—an advantage over SLM-based methods (Chen et al., 2014; Lu et al., 2017). As a demonstration, we generated 520 nm and 635 nm Bessel beams concurrently and observed negligible chromatic shift over a broad NA range (Figure 1—figure supplement 2). This minimum chromatic aberration minimizes pulsed laser dispersion, enhancing fluorescence excitation efficiency. Cortical-wide imaging of vascular dynamics and neurovascular coupling tBessel-TPFM enables rapid volumetric imaging, but its axial beam length must be optimized. Overly long beams cause structural overlap that obscures signal localization, while overly short beams underutilize their volumetric speedup (Figure 2A). To determine the optimal beam length for vascular imaging, we quantified axial inter-vessel distances (AIV) at different cortical depths from 3D Gaussian-TPFM data. Gamma-function fits revealed depth-dependent AIV (Figure 2—figure supplement 1). This highlights the need for flexible tuning of axial beam length. To cover extended regions, we combined tBessel-TPFM with lateral tiling and piezo-driven axial jumps. Using a 0.4 NA, 150-μm-long Bessel beam, each scan covered 700×700×150 μm3 in 33 ms. With 4×4 lateral tiles and three axial jumps, we stitched 48 volumes spanning 2500×2500×450 μm3 (Figure 2B). Depth-color-coded reconstructions revealed large superficial vessels (0–150 μm) and dense capillary networks at deeper layers (150–450 μm) with penetrating arterioles and venules clearly resolved (Figure 2C). Time-lapse imaging enabled visualization of vasodilation and vasoconstriction dynamics (Figure 2C and Figure 2—video 1), allowing further investigation of neurovascular coupling (NVC). Large-scale volumetric vascular imaging and neurovascular coupling. (A) Left: 3D rendering of a 350×350×450 μm3 Gaussian stack showing dense cortical vasculature. Right: representative Bessel images with beam lengths of 17 μm (orange), 35 μm (magenta), and 140 μm (blue), illustrating the trade-off between information content and structural overlap. (B) Tunable Bessel (tBessel) scan combining lateral tiling (4×4) and focal jumps (3, color-coded), yielding 48 tiles covering a 2,500×2,500×450 μm3 cortical volume. Scale bar: 200 μm. (C) Combined millimeter-scale tBessel image from (B). White box: sub-capillary resolution. Green box: penetrating arterioles/venules (arrows). Right: vasoconstriction and vasodilation of the vessel marked in red. Scale bar: 200 μm. (D) Experimental setup for functional imaging of primary visual cortex (V1). Mice with cranial windows over V1 were presented moving gratings in eight directions. Five planes spanning a 260×260×400 μm3 volume were acquired at 2.5 Hz (five trials per direction). Two neurons were analyzed for fluorescence dynamics, and vessels were outlined for resliced space–time plots of diameter changes. (E) Top: averaged calcium traces (green) from two neurons. Middle: raw and segmented resliced images from lines 1 and 2 in (D). Bottom: overlay of neuronal activity (green) and vessel diameter (magenta) showing strong correlation, with vascular changes lagging neuronal responses (arrows). Figure 2—figure supplement 1.Analysis of inter-vessel distance at different depths in mouse cortex.(A) Histogram (top) and representative image (bottom) of inter-vessel distance 0–165 μm below pia. The data is fitted to a gamma function, with the mode indicating an optimal Bessel beam length of 44 μm for imaging (red dashed line). (B) Histogram (top) and representative image (bottom) 165–330 μm below pia, with a mode of 36 μm (red dashed line), showing slightly closer vessel spacing compared to the surface. (C) Histogram (top) and representative image (bottom) 330–500 μm below pia, where the mode of vessel separation is 38 μm (red dashed line). (D) Plots illustrating vessel occupancy and overlap along the axial direction from surface to depth. The orange line represents the fraction of pixels in the mean intensity projection that are occupied by blood vessels, while the blue line shows the fraction of these vessel-containing pixels that exhibit overlap. (E) Average blood vessel distance varies at different depths. Analysis of inter-vessel distance at different depths in mouse cortex. (A) Histogram (top) and representative image (bottom) of inter-vessel distance 0–165 μm below pia. The data is fitted to a gamma function, with the mode indicating an optimal Bessel beam length of 44 μm for imaging (red dashed line). (B) Histogram (top) and representative image (bottom) 165–330 μm below pia, with a mode of 36 μm (red dashed line), showing slightly closer vessel spacing compared to the surface. (C) Histogram (top) and representative image (bottom) 330–500 μm below pia, where the mode of vessel separation is 38 μm (red dashed line). (D) Plots illustrating vessel occupancy and overlap along the axial direction from surface to depth. The orange line represents the fraction of pixels in the mean intensity projection that are occupied by blood vessels, while the blue line shows the fraction of these vessel-containing pixels that exhibit overlap. (E) Average blood vessel distance varies at different depths. Figure 2—figure supplement 2.Neurovascular coupling in response to visual stimulation.(A) Schematic of experimental setup for functional brain imaging of primary visual cortex (V1). Mice with cranial windows installed over V1 area were imaged while being exposed to moving gratings towards eight directions. (B) Mean intensity projection of an 80-μm-thick image stack at different depths, which was collected with Gaussian focus scanning at 2 μm z steps, with structures color-coded by depth. (C) Images of the same volume of brain collected by scanning a Bessel focus with the length of 80 μm for each depth. (D) Schematic diagram of how to use tunable Bessel (tBessel) foci for cross-layer deep brain imaging. A Bessel focus with the axial length of 80 μm can cover 80 μm deep brain volume. When it is moved by piezoelectric actuators along z direction four times with each time jumping 80 μm, we can cover the complete 0 through 400 μm deep brain volume with five Bessel planes at fast speed (2.5 Hz in this case). (E) Field-of-view (FOV) from Plane #1 in Figure 2D showing where lines were drawn. (F) The intensity over Line 3 from a venous across five trials aligned by eight drifting grating angles from 0° to 315°. Raw and segmented images from resliced stacks for Line 3 were shown. Summed intensity plot of lines (Line 3, in magenta) was overlaid with calcium trace of Neuron 1 with correlation coefficient being 0.035. (G) Cross-correlation matrix among the two selected neurons and the 15 blood vessels. (H) Raster plot of the normalized activities of the two selected neurons and diameter changes of the 15 blood vessels (Line 1–15) in (D). (I) Correlation coefficients between the temporal curves from the 15 blood vessels and Neuron 1 (blue) or Neuron 2 (red). Neurovascular coupling in response to visual stimulation. (A) Schematic of experimental setup for functional brain imaging of primary visual cortex (V1). Mice with cranial windows installed over V1 area were imaged while being exposed to moving gratings towards eight directions. (B) Mean intensity projection of an 80-μm-thick image stack at different depths, which was collected with Gaussian focus scanning at 2 μm z steps, with structures color-coded by depth. (C) Images of the same volume of brain collected by scanning a Bessel focus with the length of 80 μm for each depth. (D) Schematic diagram of how to use tunable Bessel (tBessel) foci for cross-layer deep brain imaging. A Bessel focus with the axial length of 80 μm can cover 80 μm deep brain volume. When it is moved by piezoelectric actuators along z direction four times with each time jumping 80 μm, we can cover the complete 0 through 400 μm deep brain volume with five Bessel planes at fast speed (2.5 Hz in this case). (E) Field-of-view (FOV) from Plane #1 in Figure 2D showing where lines were drawn. (F) The intensity over Line 3 from a venous across five trials aligned by eight drifting grating angles from 0° to 315°. Raw and segmented images from resliced stacks for Line 3 were shown. Summed intensity plot of lines (Line 3, in magenta) was overlaid with calcium trace of Neuron 1 with correlation coefficient being 0.035. (G) Cross-correlation matrix among the two selected neurons and the 15 blood vessels. (H) Raster plot of the normalized activities of the two selected neurons and diameter changes of the 15 blood vessels (Line 1–15) in (D). (I) Correlation coefficients between the temporal curves from the 15 blood vessels and Neuron 1 (blue) or Neuron 2 (red). Figure 2—video 1.Time-lapse hemodynamics imaging over a 1400×1400×150 μm3 volume showing spontaneous neurovascular activities at 15 Hz and responses to moving grating stimulations at 3 Hz. Time-lapse hemodynamics imaging over a 1400×1400×150 μm3 volume showing spontaneous neurovascular activities at 15 Hz and responses to moving grating stimulations at 3 Hz. We investigated NVC in the primary visual cortex (V1) of awake mice using tBessel-TPFM with focal jumping (Figure 2D). NVC links neuronal activation to rapid increases in blood flow that supply nutrients and clear metabolites, and its disruption is implicated in neurological and psychiatric disease (Iadecola, 2004; Kaplan et al., 2020; Kisler et al., 2017; Schaeffer and Iadecola, 2021). We simultaneously monitored neuronal activity with GCaMP and vascular dynamics across cortical layers during visual stimulation (Niell and Stryker, 2008; Figure 2D, Figure 2—figure supplement 2A). From Gaussian reference stacks (260×260×400 μm3), we determined an 80 μm long Bessel beam with five focal jumps as optimal, balancing imaging speed and axial overlap (Figure 2—figure supplement 2B, C). With this configuration, we imaged neuronal calcium and vascular dynamics at 3 Hz while presenting moving gratings to the mice. Trial-averaged calcium traces showed strong direction selectivity (Figure 2E, top). To assess vascular responses, 15 vessels spanning arterioles, venules, and capillaries were analyzed across imaging planes (Figure 2D). Space–time plots from line-cuts revealed clear dilation in arterioles but little change in neighboring venules (Figure 2E, middle; Figure 2—figure supplement 2E, F). Vasodilation consistently lagged neuronal activity (Figure 2E, bottom), indicating activity-evoked vascular responses. Largest dilations and strongest neuron–vessel correlations occurred in superficial layers (Figure 2—figure supplement 2G, H), though significant correlations persisted in penetrating arterioles of deeper layers (e.g. line 9, Figure 2—figure supplement 2I). High-speed hemodynamics mapping with tunable spatiotemporal resolutions The capacity to spatially map rapid blood flow across large brain volumes has broad-reaching implications (Anderle et al., 2025; Iadecola, 2004; Kisler et al., 2017; Sweeney et al., 2018). When applied to hemodynamics imaging, tBessel-TPFM offers two key advantages: robustness against axial motion artifacts and the capability to track blood flows in vessels at steep angles to the focal plane. First, a critical challenge in conventional TPFM imaging of awake mice is motion artifacts. While lateral motion artifacts can be readily corrected computationally, axial motion—typically with amplitudes of several microns—can shift structures out of the Gaussian focal plane (Figure 3—figure supplement 1A). We performed 2D time-lapse imaging 60 μm below pia over a 400×400 μm2 FOV at 30 Hz (Figure 3A). A kymograph of a representative image column shows sporadic but high-amplitude fluctuations, characteristic of axial motion artifacts (Figure 3—figure supplement 1B). To further illustrate these artifacts, we color-coded images acquired at different time points across a 20 s period and combined them, revealing substantial structural shifts in and out of the Gaussian focal plane (Figure 3—figure supplement 1C). In contrast, axial motion introduces minimum artifacts in tBessel-TPFM due to the extended axial beam length (Figure 3—figure supplement 1D). We imaged the same FOV with a 0.4 NA Bessel beam at 30 Hz and found little fluctuations from the kymograph (Figure 3—figure supplement 1E and Figure 3—video 1). Likewise, the color-coded time-lapse images exhibit no noticeable structural shifts (Figure 3—figure supplement 1F). High-speed blood flow mapping in normal and ischemic stroke mice. (A) Widefield and schematic view of mice brain vasculature. (B) Schematics (left) and images (right) comparing Gaussian (top; 2 μm depth of focus) and tunable Bessel (tBessel) (bottom; 80 μm long) scanning. Gaussian imaging restricts measurements to vessels nearly parallel to the imaging plane, whereas tBessel enables blood flow measurement across a broad range of vessel orientations. Scale bars: 20 μm. (C) Workflow for blood flow measurement. Left: 3D Gaussian stack highlighting a vessel segment (blue). Bottom: real-time tBessel imaging showing moving blood cells. Right: kymographs, with blood cells appearing as dark streaks (arrows). Velocities are extracted from 2D tBessel streak slopes and corrected for vessel 3D length. (D) Mean intensity projection of a Gaussian stack (400×400×120 μm3, 40–160 μm below pia, depth color-coded) versus tBessel scans with NA = 0.4, 0.6, and 0.8. Insets: experimentally measured point spread functions (PSFs, scale bar: 1.5 μm) and optical transfer functions (OTFs). (E) Trade-off between spatial resolution and imaging speed: high resolution for capillaries versus low resolution for larger vessels. (F) Blood flow speed versus vessel diameter for 42 segments imaged with 0.4 NA tBessel at 58 Hz. (G) Frame scanning versus line scanning: restricting scans to vessel regions improves speed and accuracy for large vessels. (H) Blood flow speed versus vessel diameter measured with 1 kHz line scans. Red: arteries; blue: veins. (I) Schematics of stroke induction. (J) tBessel-TPFM hemodynamics of a 1400×1400×140 μm³ volume before stroke induction. Blood flow speeds (mm/s) measured by 1 kHz line scans; numbers indicate speed, arrows indicate direction (red: arterioles, blue: veins). Representative kymographs of three linecuts shown at right. Scale bar: 100 μm. (K) Same measurement after stroke induction. Scale bar: 100 μm. (L) Paired plot of blood flow speed before and after stroke induction (N=17). Wilcoxon test, p=1×10–5. Figure 3—figure supplement 1.Tracking hemodynamics in live mouse brains.(A) Schematics of Gaussian imaging: axial motion can move the structures of interest in and out of the focal plane. (B) A representative time-lapse vasculature image (400×400 μm2) collected with Gaussian two-photon fluorescence microscopy (TPFM). Scale Bar: 100 μm. On the right, kymograph of the green line cut. Red boxes highlighted axial motion-induced artifacts. (C) A color-coded projection of the time-lapse image series. White color indicates structures that stay unchanged, while other colors highlight structural changes due to mouse axial motion. (D)-(F), Schematics (D), representative time-lapse and kymograph (E), and color-coded projection (F) of the same blood vessel images collected by an 80 μm long tunable Bessel (tBessel) beam. (G) Color-coded blood vessel orientation map showing a relatively uniform distribution of blood vessels orientations. Scale bar: 50 μm. (H) Diagram of the line-scan measurement under the conventional Gaussian foci with axial point-spread function of 2 μm. When the length of the line at the xy plane is 15 μm, since arctan(2/15) is 7.6o, blood vessels tiling higher than this angle (−7.6 to –90 degrees and –7.6 to –90 degrees) will not be available for line-scan blood flow measurement. (I) Cumulative distribution of orientation angles of blood vessels shown in (G) averaged over five projections. Gray area shows the standard deviation. Blue area indicates the measurable area and red area indicates the non-measurable area in the setting shown in (H). Numbers show the probability correspond to –7.6 and 7.6 degrees at the averaged line. (J) Schematic of red blood cells moving through blood vessel with an angle to the horizontal plane. The same red blood cell must be captured between two frames to be registered for blood flow speed measurements. (K) Simulated maximum measurable flow speed plotted against tBessel resolution with same field-of-view (FOV) and Bessel length, of blood vessels with different orientation angles (color-coded). (L) Simulated maximum measurable flow speed plotted against tBessel length of blood vessels with different orientation angles (color-coded). A Gaussian focus is equivalent to a 2 μm long tBessel beam as shown in the gray shaded area. Tracking hemodynamics in live mouse brains. (A) Schematics of Gaussian imaging: axial motion can move the structures of interest in and out of the focal plane. (B) A representative time-lapse vasculature image (400×400 μm2) collected with Gaussian two-photon fluorescence microscopy (TPFM). Scale Bar: 100 μm. On the right, kymograph of the green line cut. Red boxes highlighted axial motion-induced artifacts. (C) A color-coded projection of the time-lapse image series. White color indicates structures that stay unchanged, while other colors highlight structural changes due to mouse axial motion. (D)-(F), Schematics (D), representative time-lapse and kymograph (E), and color-coded projection (F) of the same blood vessel images collected by an 80 μm long tunable Bessel (tBessel) beam. (G) Color-coded blood vessel orientation map showing a relatively uniform distribution of blood vessels orientations. Scale bar: 50 μm. (H) Diagram of the line-scan measurement under the conventional Gaussian foci with axial point-spread function of 2 μm. When the length of the line at the xy plane is 15 μm, since arctan(2/15) is 7.6o, blood vessels tiling higher than this angle (−7.6 to –90 degrees and –7.6 to –90 degrees) will not be available for line-scan blood flow measurement. (I) Cumulative distribution of orientation angles of blood vessels shown in (G) averaged over five projections. Gray area shows the standard deviation. Blue area indicates the measurable area and red area indicates the non-measurable area in the setting shown in (H). Numbers show the probability correspond to –7.6 and 7.6 degrees at the averaged line. (J) Schematic of red blood cells moving through blood vessel with an angle to the horizontal plane. The same red blood cell must be captured between two frames to be registered for blood flow speed measurements. (K) Simulated maximum measurable flow speed plotted against tBessel resolution with same field-of-view (FOV) and Bessel length, of blood vessels with different orientation angles (color-coded). (L) Simulated maximum measurable flow speed plotted against tBessel length of blood vessels with different orientation angles (color-coded). A Gaussian focus is equivalent to a 2 μm long tBessel beam as shown in the gray shaded area. Figure 3—figure supplement 2.Measuring blood flow speed with line-scan tunable Bessel (tBessel)-two-photon fluorescence microscopy (TPFM).(A) Schematic of line-scan for blood flow measurement. The line-scan path is represented as a red line and a stack of sequential line-scans showing the red blood cell at three different locations in the vessel. (B) The 2D imaging plane before line-scanning the same blood vessel under Gaussian foci (upper panel) or 80-μm-length Bessel foci (lower panel). (C) Space-time images and the plot of blood flow speed as a function of time. The repetition rate of the line-scan is 1 kHz. (D) Violin plot showing the distribution of flow speed (in millimeter per second, mm/s) calculated through the streak angle of RBCs in each imaging paradigm. N=234 angles for Gaussian and 97 for Bessel. P-values were calculated by the two-sided Student’s t-test. p=0.21. (E) Gaussian image stack of image of a 200×200×80 µm3 volume of vasculature and tBessel-TPFM volumetric imaging of the same volume. (F) A segment of blood vessel was chosen for line scan at 1 kHz for 5 s (G) Kymographs were generated and analyzed using the line-scanning particle image velocimetry method. Median velocity was calculated. (H) and (I), the line width was corrected by reslicing the stack and found the spanning range of the line along z direction. The true line width was calculated for correction of the flow speed. (J) Blood flow speed before and after correction from 16 line measurements. Measuring blood flow speed with line-scan tunable Bessel (tBessel)-two-photon fluorescence microscopy (TPFM). (A) Schematic of line-scan for blood flow measurement. The line-scan path is represented as a red line and a stack of sequential line-scans showing the red blood cell at three different locations in the vessel. (B) The 2D imaging plane before line-scanning the same blood vessel under Gaussian foci (upper panel) or 80-μm-length Bessel foci (lower panel). (C) Space-time images and the plot of blood flow speed as a function of time. The repetition rate of the line-scan is 1 kHz. (D) Violin plot showing the distribution of flow speed (in millimeter per second, mm/s) calculated through the streak angle of RBCs in each imaging paradigm. N=234 angles for Gaussian and 97 for Bessel. P-values were calculated by the two-sided Student’s t-test. p=0.21. (E) Gaussian image stack of image of a 200×200×80 µm3 volume of vasculature and tBessel-TPFM volumetric imaging of the same volume. (F) A segment of blood vessel was chosen for line scan at 1 kHz for 5 s (G) Kymographs were generated and analyzed using the line-scanning particle image velocimetry method. Median velocity was calculated. (H) and (I), the line width was corrected by reslicing the stack and found the spanning range of the line along z direction. The true line width was calculated for correction of the flow speed. (J) Blood flow speed before and after correction from 16 line measurements. Figure 3—figure supplement 3.Characterization of photothrombosis model of ischemic stroke in the mouse visual cortex.(A) The bright field images of the cranial window (3 mm diameter) and LSI images before and after stroke induction. (B) TTC staining of the mouse brain 24 hr (day 1) after stroke induction. Characterization of photothrombosis model of ischemic stroke in the mouse visual cortex. (A) The bright field images of the cranial window (3 mm diameter) and LSI images before and after stroke induction. (B) TTC staining of the mouse brain 24 hr (day 1) after stroke induction. Figure 3—video 1.Time-lapse imaging showing direct comparison of axial motion artifact between Gaussian-two-photon fluorescence microscopy (TPFM) (left) and Bessel-TPFM (right) over a 400×400 μm2 field of view at 30 Hz. Time-lapse imaging showing direct comparison of axial motion artifact between Gaussian-two-photon fluorescence microscopy (TPFM) (left) and Bessel-TPFM (right) over a 400×400 μm2 field of view at 30 Hz. Figure 3—video 2.Time-lapse imaging of blood vessel for blood flow velocity measurement over a 400×400×120 μm3 volume at 58 Hz. Time-lapse imaging of blood vessel for blood flow velocity measurement over a 400×400×120 μm3 volume at 58 Hz. Next, we demonstrated that tBessel-TPFM enables tracking of blood flows in vessels that are inaccessible by conventional Gaussian-TPFM. With Gaussian beams, only vessels nearly parallel to the focal plane provide segments long enough within its ~2 μm depth of focus to measure flow. For instance, a 15 μm segment is required to resolve flows up to 15 mm/s, restricting usable orientations to within ~7.6° of the focal plane (Figure 3—figure supplement 1G). Analysis of cortical vasculature orientation in mice showed a relatively uniform distribution (Figure 3—figure supplement 1H), meaning Gaussian scanning excludes ~90% of vessels (Figure 3B, Figure 3—figure supplement 1I). By contrast, our tBessel-TPFM with extended axial beam length can capture vessels over a broad orientation range (Figure 3B). Simulations confirmed that a 60 μm Bessel beam can measure flows up to 1.5 mm/s in vessels angled up to 80° (Figure 3—figure supplement 1L and Appendix 3). To assess tBessel-TPFM performance, we imaged Rhodamine B–labeled vasculature in a 400×400×120-μm3 cortical volume (Figure 3C). With NA = 0.4 at 58 Hz, unlabeled red blood cells show up as dark streaks in kymographs (Figure 3C, Figure 3—figure supplement 1J and Figure 3—video 2). To account for the projection nature of Bessel-TPFM, we manually traced the blood vessel segments in 3D Gaussian structural data and measured their 3D lengths (Fan et al., 2020; Figure 3C, right panels; Methods). The acquisition frame rate sets the upper bound of measurable flow speeds. In tBessel-TPFM, lowering NA enables faster imaging but at a reduced resolution. We quantified this resolution–speed trade-off by imaging the same region with NA = 0.4, 0.6, and 0.8. NA = 0.4 enabled 58 Hz imaging with coarser resolution, as shown by the point spread function (PSF) and optical transfer function (OTF), whereas NA = 0.8 provided higher resolution at 29 Hz (Figure 3D). Practically, high-NA, slower scans best capture capillaries, while low-NA, faster scans suit arterioles and venules (Figure 3E). By balancing resolution with acquisition speed using our tBessel module, we mapped 3D flow in 42 vessels (Figure 3F) and confirmed that blood flow speeds are positively correlated with vessel diameters. Tracking blood flows before and after ischemic stroke at kilohertz rate To be able to track individual red blood cells, spatial resolution cannot be reduced indefinitely. Therefore, while tBessel-TPFM offers 10–100× speedup over Gaussian-TPFM in volumetric imaging, the maximum measurable flow speed is still limited by the 2D frame scanning rate, typically tens frames per second (fps) (Figure 3—figure supplement 1K). To measure ultrafast hemodynamics in large-diameter veins and arterioles, we implemented 1D line scanning at kilohertz rates (Figure 3G; Meng et al., 2022). In this mode, synchronized galvo–galvo scanning drives the beam back and forth along targeted vessel segments, directly generating kymographs (Figure 3—figure supplement 2A). To validate this approach, we compared flow speeds measured by 1D line-scan Bessel and Gaussian beams on the same vessel (~20 μm horizontal span). No significant differences were observed (Figure 3—figure supplement 2B and C). Using 1D line scanning tBessel-TPFM, we measured speeds up to 23 mm/s in arterioles and 11.7 mm/s in veins—20× beyond the limits of frame scanning (Figure 3H). Notably, for vessels of similar diameter, flow in arterioles was three times faster than in veins. Last, we applied 1D line scanning tBessel-TPFM to an ischemic stroke model in mice to investigate hemodynamic changes before and after photothrombosis (Labat-Gest and Tomasi, 2013). Rose Bengal was administered intraperitoneally and activated by targeted laser illumination that induced endothelial damage and thrombosis (Figure 3I; Materials and methods). Laser speckle imaging confirmed a sharp reduction of blood flow in the targeted cortical region (~100 μm diameter), consistent with established ischemic injury (Figure 3—figure supplement 3). We mapped flow speeds of 17 vessel segments across a 1400×1400×140 μm3 cortical volume before (Figure 3J) and after stroke induction (Figure 3K). To ensure accurate kymograph construction, 3D Gaussian stacks were acquired before and after each session to extract vessel lengths (Figure 3—figure supplement 2E-J; Materials and methods). Median flow speeds over 5 s were calculated for each vessel. Before stroke, flows up to 23.0 mm/s were observed. After stroke, nearly all vessels exhibited dramatic reductions, in some cases up to 100-fold (Figure 3L). These results demonstrate that tBessel-TPFM, with tunable resolution and high-speed line scanning, provides a versatile platform for mapping flow dynamics across diverse vessel sizes and orientations in both healthy and pathological states. Volumetric neuronal activity imaging with targeted optogenetic stimulation Neuroscience increasingly relies on experiments that integrate targeted optical perturbations (e.g. optogenetic stimulation or microsurgical ablation) with high-speed volumetric imaging to investigate local and network-level responses (Yang et al., 2018). A critical requirement for such a paradigm is precise spatial co-registration between the perturbation beam and the imaging volumes (Figure 4A). Existing Bessel modules struggle to meet this requirement because tuning beam parameters shifts the axial center of the imaging Bessel beam relative to the perturbation Gaussian focus (Figure 1—figure supplement 1), causing misalignment between perturbation and imaging paths. In contrast, our tBessel module resolves this challenge by maintaining a fixed axial center during beam tuning, ensuring that the Bessel imaging volume remains aligned with the Gaussian stimulation beam over a wide range of parameters (Figure 4B). Some mild asymmetry observed in the axial PSF is not attributed to the tBessel module, but rather to non-uniformity in the input Gaussian beam (Appendix 2). To demonstrate this advantage, we combined two-photon optogenetic stimulation with volumetric calcium imaging. A Gaussian 1040 nm beam delivered spiral-pattern stimulation to a ChRmine-expressing neuron, while a 920 nm tBessel beam simultaneously captured calcium dynamics across a 196×196×80 µm3 cortical volume spanning planes above and below the stimulation site (Figure 4—figure supplement 1; Materials and methods). A Gaussian reference stack was first acquired to select the stimulation plane and calibrate beam alignment (Figure 4C). Optogenetic stimulation reliably evoked robust calcium rises in the targeted neuron (Figure 4D, neuron 1), confirming precise activation. Importantly, calcium spikes were also observed in neurons located above and below the focal plane (Figure 4D), reflecting functional network responses that would be missed by conventional Gaussian-based imaging. Cross-correlation analysis further revealed putative connectivity among these neurons (Figure 4E), highlighting the ability of tBessel-TPFM to link targeted perturbations with volumetric network-level readouts in vivo. Video-rate volumetric functional imaging with targeted optogenetic stimulation. (A) Experimental setup. A Gaussian beam (blue) delivers 3D localized optogenetic stimulation to a neuron, while a tunable Bessel (tBessel) beam enables volumetric imaging symmetrically above and below the stimulation plane. (B) Schematics and axial point spread functions (PSFs) of the stimulation Gaussian beam (blue), and short (yellow) and long (red) tBessel imaging beams, showing that the extended projection is always symmetric with respect to the Gaussian stimulation plane. The non-uniformity in intensity comes from the input Gaussian beam. Scale bar: 10 μm. (C) Depth color-coded projection of volumetric functional imaging showing the stimulated neuron (neuron 1) and surrounding neurons; 16 neurons were selected for analysis. Scale bar: 10 μm. (D) Representative calcium transients from neurons numbered in (C). Light blue bars mark the timing of optogenetic stimulation pulses delivered to neuron 1. (E) Pearson correlation map of calcium dynamics among the neurons numbered in (C). Figure 4—figure supplement 1.Integrated optogenetic stimulation and volumetric imaging.(A) Schematic (left) of the experimental configuration. Right: In fixed tissue, arbitrary stimulation patterns can be planned and executed with high precision using the stimulation beam (top). In vivo stimulation begins with selecting a target neuron, followed by planning a spiral (vortex) pattern to deliver light precisely to the soma for single-cell activation. (B) Schematic of the in vivo experiment. Mice expressed a bicistronic construct (syn-GCaMP6s-P2A-ChRmine-Kv2.1) that enables co-expression of the calcium indicator GCaMP6s and the optogenetic actuator ChRmine in the same neurons. Right: Example calcium trace showing reliable responses to repeated optogenetic stimulation (red arrows). (C) Sequential stimulation of four individual neurons (3 ms per site with 1 ms inter-site pause). Bottom: Calcium traces from each ROI. Yellow arrows mark stimulation onset. Scale bars: 100 μm. Integrated optogenetic stimulation and volumetric imaging. (A) Schematic (left) of the experimental configuration. Right: In fixed tissue, arbitrary stimulation patterns can be planned and executed with high precision using the stimulation beam (top). In vivo stimulation begins with selecting a target neuron, followed by planning a spiral (vortex) pattern to deliver light precisely to the soma for single-cell activation. (B) Schematic of the in vivo experiment. Mice expressed a bicistronic construct (syn-GCaMP6s-P2A-ChRmine-Kv2.1) that enables co-expression of the calcium indicator GCaMP6s and the optogenetic actuator ChRmine in the same neurons. Right: Example calcium trace showing reliable responses to repeated optogenetic stimulation (red arrows). (C) Sequential stimulation of four individual neurons (3 ms per site with 1 ms inter-site pause). Bottom: Calcium traces from each ROI. Yellow arrows mark stimulation onset. Scale bars: 100 μm. Rapid microglial dynamics imaging with laser ablation Last, we applied tBessel-TPFM to monitor neuroimmune responses following targeted single-cell ablation. The vasculatures of transgenic mice expressing GFP in microglia was counter-labeled with dextran–Rhodamine B (Figure 5A; Materials and methods). A 3D Gaussian reference stack (200×200×120 µm3) was first acquired, and a single plane was selected for two-photon ablation of a single microglial cell (Figure 5B and C). Post-ablation, volumetric imaging was performed with a 120-µm-long, 0.7 NA Bessel beam at 15 Hz for 10 min to capture microglial process dynamics (Figure 5D). To maximize interpretability while minimizing photodamage (Kong et al., 2007; Ji et al., 2008; Icha et al., 2017; Oracz et al., 2017), we imaged the microglia dynamics with low signal-to-noise-ratio (SNR) barely sufficient to identify the rapid extension and retraction of microglial process dynamics. We then built and trained a neural network based on the recently developed content-aware image restoration (CARE) method to denoise the low SNR images (Weigert et al., 2018; Figure 5—figure supplement 1A-C; Materials and methods), followed by Richardson–Lucy deconvolution (Figure 5—figure supplement 1D). Rapid volumetric imaging of microglial responses to targeted ablation. (A) Experimental setup: a Gaussian beam (green) delivers targeted ablation of a single microglial cell, while a tunable Bessel (tBessel) beam (red) provides symmetric volumetric imaging above and below the ablation plane. (B) Mean intensity projection of a 200×200×120 μm3 Gaussian stack, depth color-coded. White box marks the targeted microglia. Scale bar: 20 μm. (C) Gaussian plane images of the targeted cell before (left, arrow) and after (right, arrow) ablation. Scale bar: 10 μm. (D) Representative 15 Hz volumetric tBessel data with a 120-μm-long beam (NA = 0.7). Raw (left), denoised (center), and deconvolved (right) images. Scale bar: 10 μm. (E) Time-lapse snapshots showing process extension toward the ablation site (arrowheads) at 1 min 15 s, 4 min 0 s, and 9 min 0 s, revealing a two-wave response. Scale bar: 10 μm. (F) Zoomed views of two regions (green and blue boxes in (D)). Arrowheads indicate process extension toward the ablation site (top, green box) and retraction opposite the lesion (bottom, blue box) across the 10 min imaging period. Scale bar: 5 μm. Figure 5—figure supplement 1.Denoising and deconvolution pipeline.(A) Schematic of the Content-Aware Image Restoration (CARE)-based U-Net architecture for denoising. Training data were generated by averaging 10 consecutive raw frames to produce high-signal-to-noise-ratio (SNR) ‘ground truth’ images, paired with corresponding single-frame low-SNR inputs. (B) Representative example comparing raw, denoised, and ground truth images. Line profile analysis (right) demonstrates high concordance with the ground truth. Scale bar: 20 μm. (C) Comparison images of raw, denoised, and deconvolved images. Scale bars: 20 μm. Denoising and deconvolution pipeline. (A) Schematic of the Content-Aware Image Restoration (CARE)-based U-Net architecture for denoising. Training data were generated by averaging 10 consecutive raw frames to produce high-signal-to-noise-ratio (SNR) ‘ground truth’ images, paired with corresponding single-frame low-SNR inputs. (B) Representative example comparing raw, denoised, and ground truth images. Line profile analysis (right) demonstrates high concordance with the ground truth. Scale bar: 20 μm. (C) Comparison images of raw, denoised, and deconvolved images. Scale bars: 20 μm. Figure 5—video 1.Time-lapse imaging of microglia resoponses immediate after microablation of one microglial cell over a 200×200×120-μm3 volume at 15-Hz for 10-minutes. Time-lapse imaging of microglia resoponses immediate after microablation of one microglial cell over a 200×200×120-μm3 volume at 15-Hz for 10-minutes. Following ablation, neighboring microglia exhibited rapid responses: their somata remained stationary, but processes extended dynamically toward the damage site. Notably, two distinct waves of process extension were observed, the first arriving around 4 min post-ablation and the second at approximately 9 min (Figure 5E and Figure 5—video 1). Detailed analysis of process dynamics revealed that microglia not only extended processes toward the injury (Figure 5F, top row) but also retracted processes opposite to the damage site (Figure 5F, bottom row). Furthermore, the advancing processes displayed exploratory movements, probing the surrounding environment rather than following linear trajectories. While prior work has shown that microglia extend processes toward injury sites without soma migration (Davalos et al., 2005), these fine-scale dynamics—including two-wave responses, coordinated extension-retraction patterns, and rapid local probing—have not been previously reported, as prior technologies lacked sufficient temporal resolution for such observations. Discussion In summary, we developed tBessel-TPFM, a compact and versatile platform for high-speed volumetric imaging of brain dynamics with independently adjustable spatial resolution, axial projection length, and stable focal positioning. The tBessel module enables adaptive tuning of the Bessel beam’s resolution, imaging depth, and side-ring excitation, optimizing performance for the heterogeneous vascular structures and dynamic processes found across brain regions and depths. Critically, it addresses two major barriers to the broader adoption of Bessel beam TPFM: the complexity of existing implementations and the lack of tunability. In addition to providing full control over the Bessel beam profile, the module features a light-efficient design—achieved without diffractive elements or photomasks—and requires minimal instrumentation and programming, making it accessible to a wide range of users. Unlike conventional Bessel systems that rely on costly programmable SLMs (Lu et al., 2017) or passive optics that either lack tunability or introduce undesired axial focus shifts of the Bessel beam (Dickey and Conner, 2011; Lu et al., 2018; Takanezawa et al., 2021), tBessel-TPFM achieves full optical tunability without focus drift using only off-the-shelf refractive components. This adaptability allows researchers to match imaging parameters to specific structures—ranging from fine microglial processes and capillaries to large vessels and neuronal ensembles—within a single platform. The center-stable beam design further enables integration with optical perturbation techniques, including optogenetic stimulation and laser ablation, where precise co-registration between imaging and stimulation beams is essential. We demonstrated the broad applicability of tBessel-TPFM for brain imaging across several challenging applications. Importantly, the center-stable tunability of our tBessel-TPFM enables biological observations that are difficult or impossible to obtain with conventional Gaussian-TPFM or prior Bessel-TPFM implementations. First, by optimizing the Bessel foci length in accordance with the brain vascular structures and distribution, we achieved volumetric imaging across millimeter-scale cortical volumes at sub-capillary resolution. These observations enable quantitative measurements of blood flow speeds in microcapillaries, arterioles, and venules as well as direct observations of NVC across layers in awake mice. The extended Bessel projection, combined with focal jumping and lateral tiling, allowed rapid mapping of blood flow and vessel diameter changes over cortical volume. In addition, high-speed Bessel line scans at kilohertz rates captured ultrafast blood flow in large, steeply oriented vessels before and after ischemic stroke induction. Moreover, the platform supported precise targeted optogenetics with volumetric readout for volumetric neural connectivity mapping. Because the axial center of the Bessel beam remains fixed during NA adjustments, we achieved stable co-alignment of volumetric imaging and holographic optogenetic stimulation for all-optical physiology, enabling reliable multi-plane readout of light-evoked calcium transients. Furthermore, we performed rapid tracking of microglial process dynamics after single-cell-level laser ablation, revealing fine-scale two-phase response patterns across ~100 µm depths that would be difficult to capture with low-speed Gaussian-TPFM. Looking ahead, future developments could include closed-loop automation, in which real-time image analysis guides on-the-fly optimization of Bessel beam parameters. In addition, integration with three-photon excitation (Wang and Xu, 2020) and adaptive optics (Hampson et al., 2021) would extend high-resolution brain imaging into subcortical regions. Furthermore, advances in optical engineering—such as novel nondiffractive beam designs—may further mitigate the trade-offs among spatial resolution, axial coverage, and side-ring excitation inherent to Bessel beams (Chen et al., 2024). Nevertheless, even in its current form, the demonstrated capabilities of tBessel-TPFM already open substantial opportunities for both basic and translational brain science, including studies of vascular and immune function in neurodegenerative disease models, investigations of neurovascular and neuroimmune coupling, and the development of targeted therapeutic strategies. Beyond two-photon microscopy, the tBessel module’s versatile tunability makes it readily adaptable to other Bessel-based modalities, including light sheet microscopy (Planchon et al., 2011), optical tweezers (Garcés-Chávez et al., 2002), and ophthalmology (Khonina et al., 2020). Materials and methods Animal use All experimental protocols followed the National Institutes of Health guidelines for animal research. All procedures involving mice were approved by the Institutional Animal Care and Use Committee at the University of Maryland School of Medicine under protocol numbers: AUP-00000001 and AUP-00000002. Male and female mice (C57BL/6 J, stock #000664; CX3CR1-GFP, stock #005582; Jackson Laboratories), aged two months or older, were used in this study. Mice were housed in groups of 1–5 per cage under a normal light cycle prior to surgery. Assembly and incorporation of the tBessel module in TPFM The tBessel module consists of three axicons, three lenses, and one iris to enable independent control of the numerical aperture (NA) and the energy confinement of the generated Bessel beam. The first axicon (AX252B, Thorlabs, 635 USD) converts the incoming collimated illumination beam into a Bessel beam. An iris (SM2D25D, Thorlabs, 105 USD) is positioned at the minimum beam waist—corresponding to the sample-conjugated plane—to tune the beam’s energy confinement. A plano-convex lens (AC254-125-B, Thorlabs, 110 USD) is placed such that its front focal plane aligns with the iris. Next, a matched pair of axicons with identical angles (AX255B, Thorlabs, 635 USD) is used to adjust the NA of the Bessel beam. Finally, a 4 f lens pair (AC254-125-B and AC254-150-B, Thorlabs, 110 USD and 110 USD) relays the virtual ring focus onto a galvo scanner conjugated to the objective’s back focal plane. The entire tBessel module can be integrated into any commercial TPFM via two mirrors mounted on a rail assembly, allowing rapid switching between Gaussian and Bessel beam modes. Imaging was performed on a custom-built two-photon microscope (Modular In vivo Multiphoton Microscopy System, MIMMS) designed by Janelia Research Campus, Howard Hughes Medical Institute. In Gaussian mode, after beam expansion, the excitation laser passes through a Pockels cell and a beam expander. The tBessel module was installed as a switchable unit using a linear actuator between the resonant scanner and a preceding mirror in the conventional laser path. In both modes, the beam is focused onto a resonant scanner (8 kHz line rate) for x-axis scanning, followed by a Y-galvo mirror for y-axis scanning. The Y-galvo is optically conjugated by a pupil relay to the objective’s back focal plane. Stereotaxic surgery for in vivo imaging Surgeries were performed using a stereotaxic apparatus (RWD) and aseptic technique as previously described (Lu et al., 2020; Lu et al., 2017; Zhang et al., 2023). Mice were anaesthetized with isoflurane (1–2% by volume in O2). A craniotomy was made over the left V1 with the dura left intact. For mice that required virus injection, a beveled glass micropipette (15–20 μm tip, Drummond Scientific) was back-filled with mineral oil and connected to a hydraulic manipulator (Narishige, MO10) for precise delivery. AAV viral solutions (AAV2/1.syn-GCaMP7s, 9×1012 GC/mL; Plasmid #104487 or AAV8-hSyn-GCaMP6m-p2A-ChRmine-Kv2.1, 2×10¹² vg/mL; Plasmid #131004, Addgene) were injected at depths of ~200–400 μm below the pia at coordinates Bregma −3.4 mm and −4.0 mm (AP) and 2.2 mm and 2.6 mm (ML), delivering 10–20 nL over 2 min per site. For all animals, following injection or craniotomy, a no. 1.5 glass coverslip (Fisher Scientific) was embedded in the opening and sealed with dental acrylic. A titanium headpost was attached with cyanoacrylate glue and dental acrylic. Mice recovered for 3–4 weeks to allow opsin and GCaMP expression. Blood vessel labeling with fluorescent dyes For vascular imaging, 50 μl of 2% dextran conjugated Rhodamine B (70 kDa) or 5% dextran-conjugated fluorescein (70 kDa) was injected retro-orbitally in mice anesthetized with isoflurane (maintained at 1–2% by volume in air). Stroke induction Focal ischemic stroke was induced via photothrombosis using Rose Bengal. A cranial window over V1 was implanted at least three weeks before stroke induction. Mice were anesthetized with 1.5% isoflurane and kept on a 37 °C heating pad. Rose Bengal solution (50 μl, 20 mg/mL in PBS) was injected retro-orbitally. One minute later, a green laser (532 nm, 3 mW) illuminated a cortical region away from major vessels for 5 min. Ischemic core and peri-infarct areas were identified by subsequent imaging. In vivo two-photon imaging Gaussian or Bessel beams were scanned using a galvo-resonant mirror for 2D imaging and galvo–galvo scanners for line scans. Fluorophores were excited using a femtosecond laser (Chameleon Discovery, Coherent) and imaged with either a 25×, 1.05 NA water-immersion objective or a 16×, 0.8 NA Nikon water-immersion objective (Olympus). Emitted photons were reflected by a dichroic mirror (FF705-Di01, Semrock) and then separated by a dichroic mirror (565DCXR, Chroma). Green and red channels were detected by PMTs (H16201P-40//004, Hamamatsu) after filtering with a 510/84 nm bandpass (green; Edmund 84–097) and two 750SP short-pass filters (red; Edmund 64–332). Images were acquired with ScanImage (Pologruto et al., 2003). Line-scan analysis of blood flow speed Blood flow speed was determined from red blood cells displacement between sequential line scans using cross-correlation, as described previously (Kim et al., 2012). The pixel shift was converted to microns, and velocity calculated as v =Δx/Δt, where Δt is the time between line scans. For vessels not perpendicular to the imaging plane, a five-step geometric correction was applied: 1. Overlay the Bessel beam scan location onto Gaussian point scan stacks to align sessions. 2. Measure the lateral displacement dx of the vessel segment. 3. Determine the vertical displacement dy by comparing z-slices at each segment endpoint. 4. Calculate vessel tilt angle θ=tan(dydx)\begin{document}$\theta=\mathrm{tan}\left(\frac{\it dy}{\it dx} \right) $\end{document} 5. Correct velocity using vtrue=vcos(θ)\begin{document}$v_{true}=\frac{v}{\mathrm{cos (\theta)}}$\end{document}. This correction approximates the true flow speed; multiple measurements across the vessel improve accuracy. Segmentation of blood vessels and kymographs Image data were converted to double precision, logarithmically transformed twice (log10) to compress dynamic range, smoothed with a Gaussian filter (σ=1), and thresholded at 0.32–0.36 to produce a binary mask. The binary image was converted to double precision, and pixel counts per row were computed to quantify vessel width over time. Visual stimulation in awake mice For head-fixed awake imaging, mice were habituated 1 week after surgery. Each session involved restraining the body under a half-cylindrical cover to reduce movement, repeated 3–4 times per mouse for 15–60 min each. Imaging began 3–4 weeks after virus injection. Visual stimuli were presented on a blue-light tablet monitor (SCEPTRE) positioned 15 cm from the right eye (70°×70° visual field, oriented ~40° relative to the body axis). Stimuli were generated in MATLAB using Psychophysics Toolbox. Each trial included 8 s of a blank gray screen followed by 8 s of drifting gratings (0.05 cycles/degree, 1 Hz temporal frequency) in eight randomized directions, with five repeats per direction. Imaging (via ScanImage) started 4 s into the blank period, capturing 4 s of gray screen and 4 s of stimulus. Simultaneous two-photon optogenetics and calcium imaging Wild-type C57BL/6 J mice (8–12 weeks) previously injected with AAVs for calcium indicator and opsin expression were anesthetized (1–2% isoflurane) and head-fixed under the microscope. Layer 2/3 neurons with clear somata were identified under Gaussian-mode imaging at 920 nm (<50 mW at the sample). A 3D z-stack (~150 μm, 2 μm step size) was acquired around target cells. Optogenetic stimulation of ChRmine was delivered via the same objective using a 1040 nm spiral scan (logspiral, five revolutions, 5 ms duration) to the soma, following established protocols (Daie et al., 2021; Sridharan et al., 2022). 10 stimulations (5 s inter-stimulus interval) were applied at 70–100 mW post-objective. Volumetric imaging was then performed in Bessel mode using the same stimulation protocol. Two-photon laser ablation of single microglia CX3CR1-GFP mice with cranial windows were anesthetized (1–2% isoflurane) and head-fixed. Targeted microglia were identified by soma morphology. A 900 nm laser (~60 mW) was focused 70 μm below the dura onto the soma center and delivered for 5 s in point-stimulation mode. Successful ablation was confirmed by loss of GFP signal and morphological changes. Denoise and deconvolution To improve the SNR of microglia imaging data under low excitation power, we trained a Content-Aware Image Restoration (CARE) neural network as previously described in the literature, using paired low-SNR and high-SNR images (Weigert et al., 2018). Training data were generated from time-lapse image sequences of microglia acquired at various cortical locations under identical imaging conditions. For each location, low-SNR inputs were single frames extracted from the video, while high-SNR ground truth images were generated by averaging 10 consecutive frames from the same sequence. These paired datasets were used to train the CARE model with a U-Net architecture. After training, the network was applied to denoise time-lapse datasets acquired during microglial responses to targeted ablation. Denoised images were subsequently processed by 20 iterations of Richardson–Lucy deconvolution. Statistical analysis Analysis was performed using MATLAB with standard functions and custom scripts. Data normality was assessed; parametric tests were applied to normally distributed data, and nonparametric tests to others. For normal data, results are reported as mean ± SEM with bar graphs; for non-normal data, as median±IQR with box plots (Tukey whiskers ±1.5×IQR). Paired nonparametric data were tested with the Wilcoxon signed-rank test; unpaired nonparametric comparisons used the Wilcoxon rank-sum test. Statistical significance thresholds were: *p< 0.05, **p< 0.01, ***p< 0.001. Experiments were not blinded. Sample sizes were chosen based on common practice in the field. This important study substantially advances the imaging toolbox available to neuroscientists by presenting a tunable Bessel (tBessel-TPFM) platform that enables high-speed volumetric two-photon imaging. The evidence supporting the novel methodology is convincing, with rigorous benchmarking and demonstrations of a wide range of neuroimaging applications covering vascular dynamics, neurovascular coupling, optogenetic perturbation, and microglial responses. The work will be of broad interest to neuroscientists and imaging system tool developers. Summary: This manuscript presents a tunable Bessel-beam two-photon fluorescence microscopy (tBessel-TPFM) platform that enables high-speed volumetric imaging with stable axial focus. The work is technically strong and broadly significant, as it substantially improves the flexibility and practicality of Bessel-beam-based two-photon microscopy. The demonstrations are generally strong and bridge a wide range of neuroimaging applications, namely vascular dynamics, neurovascular coupling, optogenetic perturbation, and microglial responses. These convincingly show that the approach enables biological measurements that are difficult or impractical with existing methods. The evidence supporting the technical and biological claims is generally strong. The optical design is carefully motivated, clearly described, and validated through a combination of simulations and experimental characterization. The biological applications are diverse and well chosen to highlight the strengths of the proposed method, and the data are of high quality, with appropriate controls and comparative measurements where relevant. Strengths: (1) The optical innovation addresses a well-recognized limitation of existing Bessel-TPFM implementations, namely axial focus drift during tuning, and does so using a relatively simple, light-efficient, and cost-effective design. (2) The manuscript provides convincing experimental evidence for this being a versatile platform to map flow dynamics across diverse vessel sizes and orientations in both healthy and pathological states. (3) Biological demonstrations are comprehensive and span multiple domains such as hemodynamics, neurovascular coupling, and neuroimmune responses. (4) Quantitative analyses of blood flow across vessel sizes and orientations, including kilohertz line scanning, are particularly compelling and clearly beyond the reach of standard Gaussian TPFM. (5) Particular advantages are that higher blood slow speeds become measurable up to 23mm/sec (20x more than conventional frame scanning), and that simultaneous (Bessel-)imaging and (Gaussian-)perturbation are possible because of the stable axial focus. Weaknesses: (1) At present, the paper does not properly position the new Bessel-beam method against previous work, and fails to compare it to alternative fast volumetric imaging methods without Bessel beams. (2) The cost-effectiveness of the proposed method is not well described or supported by evidence; it would be useful to include more detail or remove this claim. (3) Some biological conclusions, e.g., regarding novel features of microglial dynamics (i.e., the observed two-wave responses and coordinated extension-retraction), are based on relatively limited sample size and would benefit from clearer discussion of variability across animals and fields of view. (4) The use of neural network-based denoising for microglial imaging is reasonable but introduces potential concerns about trustworthiness; additional clarification of validation or failure modes would strengthen confidence in these results. To conclude, most of the authors' claims are well supported by the data. The central conclusion, namely that tBessel-TPFM provides tunable volumetric imaging enabling experiments not feasible with existing two-photon approaches, is justified. Some biological interpretations would benefit from a more cautious framing, but they do not undermine the main technical and methodological contributions of the study. This is a strong and technically rigorous manuscript that makes a substantial methodological advance with clear relevance to neuroscience and intravital imaging. Minor clarifications and a slightly more measured discussion of certain biological findings are recommended. Summary: The authors describe a tunable Bessel beam two-photon microscope (tBessel-TPFM) designed to overcome a common limitation of Bessel-based volumetric imaging: axial shifts of the effective focus during Bessel beam parameter tuning. Their optical design allows independent control of axial beam length and resolution while keeping the axial center fixed. This is extensively validated through simulations and experiments. Strengths: A major strength of the work is the breadth of validation combined with the level of technical detail provided. The authors carefully characterize the optical performance of the system and clearly explain the design choices and underlying derivations, which will make it easier for others to understand and implement. The authors demonstrate the utility of the method across several in vivo applications, including neurovascular imaging, blood flow measurements, optogenetic stimulation, and microglial dynamics. Weaknesses: In the in vivo demonstrations, the authors employ different Bessel beam configurations across experiments, but the beam parameters are not dynamically tuned during live imaging. A video example showing continuous or interactive tuning of the Bessel beam within a single in vivo imaging sequence would further highlight the practical advantages of this platform and strengthen the case for its potential applications. In addition, while excitation powers are reported, the manuscript does not place these values in the broader context of known photodamage thresholds for two-photon microscopy, which would be helpful to the readers. Denoising/image restoration are applied in one of the in vivo examples, but it is unclear why this step was used specifically for this dataset and whether it was necessary to achieve adequate SNR or primarily included as an additional demonstration. Summary: The manuscript presents an elegant and cost-effective approach for generating a tunable Bessel beam on a conventional two-photon microscope. The authors assemble a compact optical module comprising three axicons and a series of lenses that permits rapid adjustment of both lateral resolution and axial extent without modifying the focal plane. This flexibility enables the system to be readily adapted to a variety of biological preparations. As a proof of concept, the authors employ the device to record blood flow velocities in cortical microcapillaries, arterioles, and venules, thereby directly visualizing vasodilatation and vasoconstriction dynamics and permitting quantitative analysis of neurovascular coupling across cortical layers in awake mice. The authors demonstrate that the tunability of the Bessel beam can be exploited to match the numerical aperture to the vessel type: a high NA configuration, albeit slower scan, is optimal for resolving flow in capillaries, whereas a low NA setting provides faster acquisition suitable for arterioles and venules. By implementing a one-dimensional line scan with the Bessel beam, they achieve an imaging speed that is twentyfold faster than conventional frame-by-frame scanning, which proves sufficient to capture hemodynamic transients before and after an induced ischemic stroke. In addition to pure observation, the authors integrate a co-propagating Gaussian line to the system, allowing simultaneous imaging and photostimulation within the same focal plane. This capability addresses a common limitation of other Bessel beam implementations, in which the observation and perturbation planes often become misaligned when the Bessel beam is altered. The manuscript also emphasizes the advantage of Bessel beam excitation for calcium imaging after a perturbation, because it captures neuronal activity in planes both above and below the nominal focal plane, signals that would be missed with a standard Gaussian focus. Finally, the authors apply the technique to investigate the neuroimmune response following targeted microglial ablation; they report that adjacent microglia extend processes toward the injury site while retracting processes in the opposite direction. Overall, the work offers a technically straightforward yet powerful extension to existing two-photon platforms, providing high-speed, volumetric imaging and stimulation capabilities that are well-suited to a broad range of neurovascular and neuroimmune studies. The experimental validation is quite thorough, and the presented data convincingly illustrates the benefits of the approach. Strengths: The authors present a truly clever and inexpensive optical module that can be integrated into almost any two-photon microscope, providing a tunable Bessel beam with a minimal modification of the existing system. The experimental data and accompanying quantitative analysis convincingly demonstrate that the system can reveal physiological events, such as capillary flow, calcium transients across multiple axial planes, and microglial process dynamics, that are difficult or impossible to capture with a conventional Gaussian beam. The breadth of experiments chosen for the manuscript illustrates the practical utility of the device and supports the authors' conclusions that it extends the functional repertoire of standard two-photon microscopy. Weaknesses: The manuscript would benefit from a more detailed contextualisation of the claimed speed advantage. Although the authors mention other techniques in the introduction, they do not provide any direct comparison with other state-of-the-art high-speed two-photon approaches such as light beads microscopy (Demas et al., Nat. Methods 2021), temporal multiplexing schemes (Weisenburger et al., Cell 2019), or random access microscopy (Villette et al., Cell 2019). A brief comparison of imaging speed, spatial resolution, and instrumental complexity would enable readers to assess the relative merits of the present method. A second limitation that warrants discussion is the inherent trade off between volumetric coverage and image specificity. Because the Bessel beam excites fluorescence throughout an extended axial range, the detector inevitably integrates signal from a three dimensional volume into a two dimensional image. In densely labelled tissue, this can lead to significant signal crosstalk, reducing contrast and complicating quantitative interpretation. A brief analysis of how labeling density affects the fidelity of flow or calcium measurements, or suggestions for mitigating crosstalk (e.g., computational deconvolution, adaptive excitation shaping, or combinatorial sparse labeling), would broaden the applicability of the technique. Public Reviews: Reviewer #1 (Public review): This manuscript presents a tunable Bessel-beam two-photon fluorescence microscopy (tBessel-TPFM) platform that enables high-speed volumetric imaging with stable axial focus. The work is technically strong and broadly significant, as it substantially improves the flexibility and practicality of Bessel-beam-based two-photon microscopy. The demonstrations are generally strong and bridge a wide range of neuroimaging applications, namely vascular dynamics, neurovascular coupling, optogenetic perturbation, and microglial responses. These convincingly show that the approach enables biological measurements that are difficult or impractical with existing methods. The evidence supporting the technical and biological claims is generally strong. The optical design is carefully motivated, clearly described, and validated through a combination of simulations and experimental characterization. The biological applications are diverse and well chosen to highlight the strengths of the proposed method, and the data are of high quality, with appropriate controls and comparative measurements where relevant. Strengths: (1) The optical innovation addresses a well-recognized limitation of existing Bessel-TPFM implementations, namely axial focus drift during tuning, and does so using a relatively simple, light-efficient, and cost-effective design. (2) The manuscript provides convincing experimental evidence for this being a versatile platform to map flow dynamics across diverse vessel sizes and orientations in both healthy and pathological states. (3) Biological demonstrations are comprehensive and span multiple domains such as hemodynamics, neurovascular coupling, and neuroimmune responses. (4) Quantitative analyses of blood flow across vessel sizes and orientations, including kilohertz line scanning, are particularly compelling and clearly beyond the reach of standard Gaussian TPFM. (5) Particular advantages are that higher blood slow speeds become measurable up to 23mm/sec (20x more than conventional frame scanning), and that simultaneous (Bessel-)imaging and (Gaussian-)perturbation are possible because of the stable axial focus. We thank the reviewer for this thoughtful and encouraging evaluation of our work. We are particularly grateful for the recognition of both the technical rigor and the broad applicability of the tBessel-TPFM platform, as well as the assessment that our approach enables biological measurements that are difficult or impractical with existing methods. We appreciate the reviewer’s detailed summary of the strengths of the manuscript, including the identification of axial focus drift as a major limitation in prior Bessel-TPFM implementations, and the value of our center-stable, light-efficient, and accessible solution. We thank the reviewer for the encouraging comment that our biological demonstrations to be compelling and well supported by quantitative analysis. Weaknesses: (1) At present, the paper does not properly position the new Bessel-beam method against previous work, and fails to compare it to alternative fast volumetric imaging methods without Bessel beams. We thank the reviewer for this important point. We agree that a more explicit comparison with existing fast volumetric imaging methods helps clarify the unique advantages of our system. Alternative fast volumetric imaging methods without Bessel beams include remote focusing (Sofroniew et al., 2016), acousto-optic deflectors (AOD) (Villette et al., 2019), piezoelectric objective stages (Göbel and Helmchen, 2007), tunable acoustic gradient lenses (TAG lens) (Huang et al., 2019), electrically tunable lenses (ETLs) (Grewe et al., 2011; Yang et al., 2018), and light beads microscopy (Demas et al., 2021). These methods have each enabled important forms of rapid volumetric imaging, but they differ in their speed, resolution, axial range, and optical complexity. For example, remote focusing can provide rapid axial refocusing while preserving high-resolution imaging but has limited defocus range and requires a carefully aligned relay system and aberration control to maintain image quality. AOD-based approaches enable fast random-access sampling, but introduce optical and calibration complexity associated with dispersion, and suffer light loss with limited diffractive efficiency. Piezoelectric objective scanning is comparatively simple and broadly accessible, but its mechanical inertia limits volume rate and can introduce artifacts during rapid or large axial motion. TAG lenses and ETLs provide compact non-mechanical axial scanning, but pose challenges on aberration control and synchronization. Light-beads microscopy achieves high volumetric throughput by near-simultaneously sampling multiple axial positions, but faces intrinsic compromise among axial coverage, number of sampling planes, and lateral sampling density, which limit lateral resolution when imaging over large depth ranges. Previous Bessel-beam TPFM approaches address some of these limitations by converting volumetric imaging into two-dimensional scanning with an axially extended focus. However, many existing implementations either rely on a fixed Bessel beam profile, which limits the ability to adapt spatial resolution and axial coverage to different biological applications, or use spatial light modulators, which provide tunability but introduce higher cost, increased optical complexity, reduced light efficiency, and sequential rather than simultaneous multi-wavelength operation. Other axicon or lens based tunable Bessel approaches have also been reported, but these designs generally introduce axial displacement of the Bessel focus during tuning. In contrast, our tBessel-TPFM design provides full tunability comparable with SLM based methods, maintaining a stable axial beam center, at the same time low cost, easy to implement, intrinsically high light efficiency and support simultaneous multi-color imaging. Therefore, tBessel-TPFM provides a unique solution for applications where axial projection is acceptable and where high-speed volumetric monitoring, tunable axial coverage, motion robustness, optical simplicity, and compatibility with simultaneous perturbation are valuable. (2) The cost-effectiveness of the proposed method is not well described or supported by evidence; it would be useful to include more detail or remove this claim. We thank the reviewer for requesting clarification and supporting evidence regarding the cost-effectiveness of our method. We now provide a detailed cost breakdown of the tBessel module. Briefly, the module consists of three axicons, three lenses, and one iris that together enable independent control of the NA and ΔNA of the generated Bessel beam. Based on the specified components, the three axicons (AX252B and AX255B, Thorlabs) cost $635 each, the three lenses (AC254-125-B×2 and AC254-150-B, Thorlabs) cost $110 each, and the iris (SM2D25D, Thorlabs) costs $105, resulting in a total system cost of approximately $2,340. For comparison, spatial light modulator (SLM)-based implementations that offer comparable tunability typically require an SLM module costing on the order of $20,000 USD, in addition to more complex optical alignment and reduced optical efficiency. (3) Some biological conclusions, e.g., regarding novel features of microglial dynamics (i.e., the observed two-wave responses and coordinated extension-retraction), are based on relatively limited sample size and would benefit from clearer discussion of variability across animals and fields of view. We thank the reviewer for this important comment regarding the limited sample size of the microglial dynamics study. We agree that a more comprehensive assessment across animals would be required to establish the generality of these biological findings. In the current study, our intent is not to draw broad biological conclusions, but rather to report observations enabled by the tBessel-TPFM platform. As noted in the manuscript, we have deliberately used descriptive language (e.g., “two distinct waves of process extension were observed” “process dynamics revealed…” and “advancing processes displayed…”) to avoid over claim of the biological findings beyond the data presented. (4) The use of neural network-based denoising for microglial imaging is reasonable but introduces potential concerns about trustworthiness; additional clarification of validation or failure modes would strengthen confidence in these results. We thank the reviewer for raising this important point regarding the reliability of neural network-based denoising. We agree that additional validation and discussion of potential failure modes are essential to build confidence in these results. To assess the fidelity of the CARE-denoised data, we performed several additional analyses (Author response image 1). First, we compared normalized raw and denoised images averaged over 10 frames. The difference between the two images was spatially uniform and primarily reflected residual noise present in the raw data, rather than structured discrepancies (Author response image 1a). As expected, brighter features like microglial somata exhibited smaller differences due to their intrinsically higher signal-to-noise ratio, whereas weaker processes showed larger noise-related differences. Second, we extended this comparison across the full time-lapse sequence by applying consistent color mapping to both raw and denoised videos and computing frame-by-frame difference maps. These analyses show that the observed differences are consistent with noise suppression, without introducing coherent structural features or altering the apparent microglial dynamics (Author response image 1b). Validation of CARE-based denoising for microglial imaging. (a) Comparison of 10-frame averaged normalized raw (left), CARE-denoised (middle), and their pixel-wise difference (right) images. The second row shows a zoomed-in view of the boxed region. (b) Color-coded time-lapse projections over a 10-min imaging session for the raw (left) and CARE-denoised (middle) data, along with their pixel-wise difference (right). To conclude, most of the authors' claims are well supported by the data. The central conclusion, namely that tBessel-TPFM provides tunable volumetric imaging enabling experiments not feasible with existing two-photon approaches, is justified. Some biological interpretations would benefit from a more cautious framing, but they do not undermine the main technical and methodological contributions of the study. This is a strong and technically rigorous manuscript that makes a substantial methodological advance with clear relevance to neuroscience and intravital imaging. Minor clarifications and a slightly more measured discussion of certain biological findings are recommended. We thank the reviewer for this thoughtful and encouraging summary of our work. We greatly appreciate the recognition that tBessel-TPFM provides a meaningful methodological advance and enables volumetric imaging experiments that are difficult or impractical with existing two-photon approaches. Reviewer #2 (Public review): The authors describe a tunable Bessel beam two-photon microscope (tBessel-TPFM) designed to overcome a common limitation of Bessel-based volumetric imaging: axial shifts of the effective focus during Bessel beam parameter tuning. Their optical design allows independent control of axial beam length and resolution while keeping the axial center fixed. This is extensively validated through simulations and experiments. Strengths: A major strength of the work is the breadth of validation combined with the level of technical detail provided. The authors carefully characterize the optical performance of the system and clearly explain the design choices and underlying derivations, which will make it easier for others to understand and implement. The authors demonstrate the utility of the method across several in vivo applications, including neurovascular imaging, blood flow measurements, optogenetic stimulation, and microglial dynamics. We thank the reviewer for their thoughtful and encouraging comments. We greatly appreciate the recognition of the technical rigor, breadth of validation, and clarity of explanation presented in our work. Weaknesses: In the in vivo demonstrations, the authors employ different Bessel beam configurations across experiments, but the beam parameters are not dynamically tuned during live imaging. A video example showing continuous or interactive tuning of the Bessel beam within a single in vivo imaging sequence would further highlight the practical advantages of this platform and strengthen the case for its potential applications. We thank the reviewer for their suggestion. While we agree that continuous or interactive tuning of the Bessel beam during imaging would further highlight the practical flexibility of the platform, and changing the Bessel beam parameters during imaging session is feasible in our tBessel-TPFM implementation, for the in vivo applications presented in this manuscript, dynamic tuning during the actual recording is generally not required. In practice, the Bessel beam parameters are selected before data acquisition based on the biological target, desired axial coverage, spatial resolution, and acceptable level of projection overlap. In addition, while excitation powers are reported, the manuscript does not place these values in the broader context of known photodamage thresholds for two-photon microscopy, which would be helpful to the readers. We thank the reviewer for bringing up this important point. It is known that multiphoton imaging relies on relatively high illumination power, which causes brain heating and thus photodamage. Previous studies have reported that continuous illumination with a 920-nm laser beam at 0.8 NA over 1000s results in a peak temperature increase of ~1.73 °C/100 mW in the brain, with power above 300 mW observed to cause cellular damage. Power levels below 250 mW were considered to be safe for long-term imaging. (Podgorski and Ranganathan, 2016) In our experiments, the measured post-objective powers range from 20 mW to 149 mW, which are well below the established safe threshold. Denoising/image restoration are applied in one of the in vivo examples, but it is unclear why this step was used specifically for this dataset and whether it was necessary to achieve adequate SNR or primarily included as an additional demonstration. We thank the reviewer for requesting clarification on the usage of the CARE denoising model. The CARE-based denoising was applied only in Figure 5, the microglial imaging example, and was primarily included as an additional demonstration of how neural network–based image restoration can be used to enhance low-SNR volumetric datasets acquired with tBessel-TPFM. All other images and analyses in the manuscript were performed on raw data without any denoising. To assess the reliability of the CARE denoising method, we further compared raw and denoised data using 10-frame averages and color-mapped the full 10-minute time-lapse video, both showed minimal differences (Response Fig 1). These analyses confirm that the CARE denoising model did not introduce structural artifacts or affect the biological dynamics observations in our dataset. Reviewer #3 (Public review): The manuscript presents an elegant and cost-effective approach for generating a tunable Bessel beam on a conventional two-photon microscope. The authors assemble a compact optical module comprising three axicons and a series of lenses that permits rapid adjustment of both lateral resolution and axial extent without modifying the focal plane. This flexibility enables the system to be readily adapted to a variety of biological preparations. As a proof of concept, the authors employ the device to record blood flow velocities in cortical microcapillaries, arterioles, and venules, thereby directly visualizing vasodilatation and vasoconstriction dynamics and permitting quantitative analysis of neurovascular coupling across cortical layers in awake mice. The authors demonstrate that the tunability of the Bessel beam can be exploited to match the numerical aperture to the vessel type: a high NA configuration, albeit slower scan, is optimal for resolving flow in capillaries, whereas a low NA setting provides faster acquisition suitable for arterioles and venules. By implementing a one-dimensional line scan with the Bessel beam, they achieve an imaging speed that is twentyfold faster than conventional frame-by-frame scanning, which proves sufficient to capture hemodynamic transients before and after an induced ischemic stroke. In addition to pure observation, the authors integrate a co-propagating Gaussian line to the system, allowing simultaneous imaging and photostimulation within the same focal plane. This capability addresses a common limitation of other Bessel beam implementations, in which the observation and perturbation planes often become misaligned when the Bessel beam is altered. The manuscript also emphasizes the advantage of Bessel beam excitation for calcium imaging after a perturbation, because it captures neuronal activity in planes both above and below the nominal focal plane, signals that would be missed with a standard Gaussian focus. Finally, the authors apply the technique to investigate the neuroimmune response following targeted microglial ablation; they report that adjacent microglia extend processes toward the injury site while retracting processes in the opposite direction. Overall, the work offers a technically straightforward yet powerful extension to existing two-photon platforms, providing high-speed, volumetric imaging and stimulation capabilities that are well-suited to a broad range of neurovascular and neuroimmune studies. The experimental validation is quite thorough, and the presented data convincingly illustrates the benefits of the approach. Strengths: The authors present a truly clever and inexpensive optical module that can be integrated into almost any two-photon microscope, providing a tunable Bessel beam with a minimal modification of the existing system. The experimental data and accompanying quantitative analysis convincingly demonstrate that the system can reveal physiological events, such as capillary flow, calcium transients across multiple axial planes, and microglial process dynamics, that are difficult or impossible to capture with a conventional Gaussian beam. The breadth of experiments chosen for the manuscript illustrates the practical utility of the device and supports the authors' conclusions that it extends the functional repertoire of standard two-photon microscopy. We sincerely thank the reviewer for the thoughtful and encouraging feedback. We're glad that the technical design and broad applicability of the tBessel module came through clearly, and we appreciate the recognition of its ease of integration and ability to capture dynamic physiological processes. Weaknesses: The manuscript would benefit from a more detailed contextualisation of the claimed speed advantage. Although the authors mention other techniques in the introduction, they do not provide any direct comparison with other state-of-the-art high-speed two-photon approaches such as light beads microscopy (Demas et al., Nat. Methods 2021), temporal multiplexing schemes (Weisenburger et al., Cell 2019), or random access microscopy (Villette et al., Cell 2019). A brief comparison of imaging speed, spatial resolution, and instrumental complexity would enable readers to assess the relative merits of the present method. We thank the reviewer for this important suggestion. We agree that a more explicit comparison with other high-speed two-photon imaging methods helps clarify the speed advantages of our system. Several existing approaches, including light-beads microscopy (LBM), temporal multiplexing, and AOD-based random-access microscopy, have demonstrated impressive high-speed volumetric imaging capabilities. Light-beads microscopy (Demas et al., 2021) reported imaging over a large volume of 5.4 × 6 × 0.5 mm3 at 2 Hz. However, this large-volume acquisition used 5-μm lateral pixel sampling, corresponding to an effective lateral resolution of approximately 10 μm. In a more comparable mesoscopic volume, LBM imaged 0.6 × 0.6 × 0.5 mm3 at 9.6 Hz with 1-μm lateral pixel sampling. In addition, the LBM module uses off-axis reflective concave mirrors, which require careful alignment, and the axial sampling range is not readily tunable. Temporal multiplexing approaches (Weisenburger et al., 2019), reported imaging over approximately 1 × 1 × 0.6 mm3 at 17 Hz. However, this volume rate was achieved with relatively coarse spatial resolution of approximately 5 μm, together with a more complex optical design involving multiplexed excitation, detection, and synchronization. AOD-based random-access microscopy (Nadella et al., 2016; Villette et al., 2019) provides very fast point or region sampling, and reported 250 × 250 μm2 imaging with 512 × 512 pixels and a 50-ns pixel dwell time, corresponding to ~0.5-μm pixel sampling and ~76 frames/s for two-dimensional imaging. However, volumetric imaging requires additional axial sampling, which lowers the effective 3D acquisition rate. In addition, AOD-based systems rely on diffractive beam steering, which introduces light loss due to finite diffraction efficiency and increases optical and calibration complexity. In comparison, tBessel-TPFM imaged a 0.4 × 0.4 × 0.12 mm3 volume at 58 Hz with 0.2-μm lateral pixel sampling. Our largest demonstrated imaging volume reached 2.5 × 2.5 × 0.45 mm3 while maintaining diffraction-limited lateral resolution. Therefore, compared with these high-speed volumetric approaches, tBessel-TPFM provides a distinct balance of volume rate and spatial sampling, and easier implementation simplicity. A second limitation that warrants discussion is the inherent trade off between volumetric coverage and image specificity. Because the Bessel beam excites fluorescence throughout an extended axial range, the detector inevitably integrates signal from a three dimensional volume into a two dimensional image. In densely labelled tissue, this can lead to significant signal crosstalk, reducing contrast and complicating quantitative interpretation. A brief analysis of how labeling density affects the fidelity of flow or calcium measurements, or suggestions for mitigating crosstalk (e.g., computational deconvolution, adaptive excitation shaping, or combinatorial sparse labeling), would broaden the applicability of the technique. We thank the reviewer for highlighting this important trade-off between volumetric coverage and image specificity in Bessel beam imaging. As Bessel beams project fluorescence from multiple features along the z-axis onto the same x–y plane, longer beams expand depth coverage at the same acquisition speed but can confound signals from axially spaced structures (Line 119-121 in manuscript). For densely labeled samples, the probability of having structures overlap in their x-y locations is high, and thus a shorter beam should be used. In sparsely labeled samples, structures have a lower probability of overlapping, and thus longer foci can be used (Line 166-168 in manuscript). Additionally, at the same NA, longer Bessel beam have more energy in the side rings surrounding the central peak, which may lead to higher background signal (Line 121-123 in manuscript) (Lu et al., 2017). These reasons necessitate to have not only NA tuning, but also independent length tuning (ΔNA tuning) to optimize imaging Bessel length to provide a balance between structural overlap that obscures signal localization, and the volumetric speedup, in any given sample based on labeling density and imaging goals, which are realized in our tBessel design. Reference: Demas, J., Manley, J., Tejera, F., Barber, K., Kim, H., Traub, F.M., Chen, B., Vaziri, A., 2021. High-speed, cortex-wide volumetric recording of neuroactivity at cellular resolution using light beads microscopy. Nat Methods 18, 1103–1111. https://doi.org/10.1038/s41592-021-01239-8 Göbel, W., Helmchen, F., 2007. In Vivo Calcium Imaging of Neural Network Function. Physiology 22, 358–365. https://doi.org/10.1152/physiol.00032.2007 Grewe, B.F., Voigt, F.F., van ’t Hoff, M., Helmchen, F., 2011. Fast two-layer two-photon imaging of neuronal cell populations using an electrically tunable lens. Biomed Opt Express 2, 2035–2046. https://doi.org/10.1364/BOE.2.002035 Huang, C., Tai, C.-Y., Yang, K.-P., Chang, W.-K., Hsu, K.-J., Hsiao, C.-C., Wu, S.-C., Lin, Y.-Y., Chiang, A.-S., Chu, S.-W., 2019. All-Optical Volumetric Physiology for Connectomics in Dense Neuronal Structures. iScience 22, 133–146. https://doi.org/10.1016/j.isci.2019.11.011 Lu, R., Sun, W., Liang, Y., Kerlin, A., Bierfeld, J., Seelig, J.D., Wilson, D.E., Scholl, B., Mohar, B., Tanimoto, M., Koyama, M., Fitzpatrick, D., Orger, M.B., Ji, N., 2017. Video-rate volumetric functional imaging of the brain at synaptic resolution. Nat Neurosci 20, 620–628. https://doi.org/10.1038/nn.4516 Nadella, K.M.N.S., Roš, H., Baragli, C., Griffiths, V.A., Konstantinou, G., Koimtzis, T., Evans, G.J., Kirkby, P.A., Silver, R.A., 2016. Random-access scanning microscopy for 3D imaging in awake behaving animals. Nat Methods 13, 1001–1004. https://doi.org/10.1038/nmeth.4033 Podgorski, K., Ranganathan, G., 2016. Brain heating induced by near-infrared lasers during multiphoton microscopy. Journal of Neurophysiology 116, 1012–1023. https://doi.org/10.1152/jn.00275.2016 Sofroniew, N.J., Flickinger, D., King, J., Svoboda, K., 2016. A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging [WWW Document]. eLife. https://doi.org/10.7554/eLife.14472 Villette, V., Chavarha, M., Dimov, I.K., Bradley, J., Pradhan, L., Mathieu, B., Evans, S.W., Chamberland, S., Shi, D., Yang, R., Kim, B.B., Ayon, A., Jalil, A., St-Pierre, F., Schnitzer, M.J., Bi, G., Toth, K., Ding, J., Dieudonné, S., Lin, M.Z., 2019. Ultrafast Two-Photon Imaging of a High-Gain Voltage Indicator in Awake Behaving Mice. Cell 179, 1590-1608.e23. https://doi.org/10.1016/j.cell.2019.11.004 Weisenburger, S., Tejera, F., Demas, J., Chen, B., Manley, J., Sparks, F.T., Traub, F.M., Daigle, T., Zeng, H., Losonczy, A., Vaziri, A., 2019. Volumetric Ca2+ Imaging in the Mouse Brain Using Hybrid Multiplexed Sculpted Light Microscopy. Cell 177, 1050-1066.e14. https://doi.org/10.1016/j.cell.2019.03.011 Yang, W., Carrillo-Reid, L., Bando, Y., Peterka, D.S., Yuste, R., 2018. Simultaneous two-photon imaging and two-photon optogenetics of cortical circuits in three dimensions. eLife 7, e32671. https://doi.org/10.7554/eLife.32671